Plan Review Stops For Permit 17040199 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-09-27 |
Time |
11:13 |
Sent To |
|
|
Notes |
2017-09-27 12:40:55 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17040199 | | ADD: 1515 N. FLAGLER DR. SUITE 100 & 700 | | CONT: LB DEVELOPMENT & ENGINEERING | | TEL: 954-881-5693 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 5TH REVIEW | | DATE: WED. SEPT. 27/ 2017 | | ACTION: BUILDING PROVISO | | | | 1A) SHEET A4.23 DETAIL 1 THE AMBULATORY ACCESSIBLE | | COMPARTMENT DOOR WILL NEED TO SHOW COMPLIANCE WITH 2014 | | FBC-ACCESSIBILITY CODE 604.8.2.2 DOORS. TOILET | | COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL | | COMPLY WITH 404, EXCEPT THAT IF THE APPROACH IS TO THE | | LATCH SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN | | THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION | | SHALL BE 42 INCHES MINIMUM. THE DOOR SHALL BE | | SELF-CLOSING. A DOOR PULL COMPLYING WITH 404.2.7 SHALL | | BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. | | | | 1B) 2014 ACCESSIBILITY CODE 404.2.3 CLEAR WIDTH. DOOR | | OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES | | MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS | | SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE | | STOP, WITH THE DOOR OPEN 90 DEGREES. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-08-09 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-08-09 |
Time |
09:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-07-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-07-19 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-07-18 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-06-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-08 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-08 |
Time |
10:10 |
Sent To |
|
|
Notes |
2017-06-08 10:48:04 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17040199 | | ADD: 1515 N. FLAGLER DR. SUITE 100 & 700 | | CONT: LB DEVELOPMENT & ENGINEERING | | TEL: 954-881-5693 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: THURS. JUNE 08/ 2017 | | ACTION: DENIED | | | | PLEASE READ!!!!!! THE RESUBMITTED NEW SET OF PLANS WAS | | NOT COLLATED WITH THE OLD PLAN SETS. THE NEW PLAN SETS | | WERE NOT COMPLETE SET OF PLANS!!!!! MISSING PLANS ONLY | | FOR ARCHITECTURE ARE: | | | | A0.04-A0.12 MISSING | | A0.14 MISSING | | A0.17-A4.21 MISSING | | A4.25-A5.51 MISSING | | | | A COMPLETE PLAN REVIEW CAN NOT BE COMPLETED UNTIL THE | | CONTRACTOR COLLATES THE PLANS! | | | | 1) SHEET A0.13 THE DOOR SCHEDULE SHOWS THE ENTRY DOOR # | | 18 WITH HARDWARE GROUP # 1 VANDAL ENTRANCE LOCK NOT | | PANIC HARDWARE, THIS IS ALLOWED, CODE COMPLIANT ON THE | | MAIN ENTRY DOOR BY EXCEPTION . 1008.1.9.3, ITEM 2. IF: | | 2. IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN OCCUPANT | | LOAD OF 300 OR LESS, GROUPS B, F, M AND S, AND IN | | PLACES OF RELIGIOUS WORSHIP, THE MAIN EXTERIOR DOOR OR | | DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED | | LOCKING DEVICES FROM THE EGRESS SIDE PROVIDED: | | 2.1. THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS | | LOCKED; | | 2.2. A READILY VISIBLE DURABLE SIGN IS POSTED ON THE | | EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: THIS | | DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE | | SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A | | CONTRASTING BACKGROUND; AND | | 2.3. THE USE OF THE KEY-OPERATED LOCKING DEVICE IS | | REVOKABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE. | | | | 2) SHEET A0.13 THE DOOR SCHEDULE SHOWS THE DOOR TO THE | | TRAINING ROOM, DOOR # 20 ALSO WITH A VANDAL ENTRY LOCK. | | THIS DOOR SHOULD HAVE PANIC HARDWARE IN ACCORDANCE WITH | | 1008.1.10. | | | | 3) THE DESIGNER OF RECORD INDICATES 1 HOUR FIRE RATED | | WALLS BETWEEN THE TENANT SPACE AND COMMON AREAS AS WELL | | AS THE TRAINING ROOM 707. PLEASE REVIEW THE MECHANICAL | | COMMENT # 5 MISSING FIRE DAMPERS IN FIRE RATED WALLS | | AND COMPLIANCE WITH 2014 FBC-B 714.1.1 DUCTS AND AIR | | TRANSFER OPENINGS. | | PENETRATIONS OF FIRE-RESISTANCE-RATED WALLS BY DUCTS | | THAT ARE NOT PROTECTED WITH DAMPERS SHALL COMPLY WITH | | SECTIONS 714.2 THROUGH 714.3.3. MISSING FIRE DAMPERS | | SEE M2.2.1. 10X8 O/A DUCT PENETRATING THE TRAINING/ | | CORRIDOR WALL, 16X12 O/A DUCT PENETRATING THE TRAINING | | ROOM/ CORRIDOR WALL, TRAINING ROOM/ VESTIBULE/ MENS | | RESTROOM AND THE 8X8 SUPPLY DUCT PENETRATING THE COPY | | ROOM/ ELEVATOR LOBBY WALL. | | | | 4) THE NEW OUTSIDE AIR DUCT WILL REQUIRE AN OUTSIDE AIR | | LOUVER ON THE EXTERIOR OF THE BUILDING. PLEASE PROVIDE | | COMPLIANCE WITH: 1609.6.4.4.1 COMPONENTS & CLADDING. | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE | | CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | WILL REQUIRE PRODUCT APPROVALS: | | (31(C) PANEL WALLS: WALL LOUVERS | | | | 5) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | 6) THE RESTROOM DETAIL 1/ A4.23 IN BOTH RESTROOMS SHOWS | | 6 OR MORE WATER CLOSETS AND OR COMBINATION OF WATER | | CLOSETS AND URINALS THEN COMPLIANCE WITH SECTION | | 213.3.1 OF THE 2014 ACCESSIBILITY CODE IS REQUIRED. | | ALSO SEE: | | 604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS. AMBULATORY | | ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH 604.8.2. | | 604.8.2.2 DOORS. TOILET COMPARTMENT DOORS, INCLUDING | | DOOR HARDWARE, SHALL COMPLY WITH 404, EXCEPT THAT IF | | THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT | | DOOR, CLEARANCE BETWEEN THE DOOR SIDE OF THE | | COMPARTMENT AND ANY OBSTRUCTION SHALL BE 42 INCHES | | (1065 MM) MINIMUM. THE DOOR SHALL BE SELF-CLOSING. A | | DOOR PULL COMPLYING WITH 404.2.7 SHALL BE PLACED ON | | BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET | | COMPARTMENT DOORS SHALL NOT SWING INTO THE MINIMUM | | REQUIRED COMPARTMENT AREA. | | | | 604.8.2.3 GRAB BARS. GRAB BARS SHALL COMPLY WITH 609. A | | SIDE-WALL GRAB BAR COMPLYING WITH 604.5.1 SHALL BE | | PROVIDED ON BOTH SIDES OF THE COMPARTMENT. | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-05-10 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-05-09 |
Time |
16:00 |
Sent To |
|
|
Notes |
2017-05-10 07:53:39 | 2014 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17040199 | | ADD: 1515 N. FLAGLER DR. SUITE 100 & 700 | | CONT: LB DEVELOPMENT & ENGINEERING | | TEL: 954-881-5693 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: WED. MAY 10/ 2017 | | ACTION: DENIED | | | | 1) SHEET A0.13 THE DOOR SCHEDULE SHOWS THE ENTRY DOOR # | | 18 WITH HARDWARE GROUP # 1 VANDAL ENTRANCE LOCK NOT | | PANIC HARDWARE, THIS IS ALLOWED, CODE COMPLIANT ON THE | | MAIN ENTRY DOOR BY EXCEPTION . 1008.1.9.3, ITEM 2. IF: | | 2. IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN OCCUPANT | | LOAD OF 300 OR LESS, GROUPS B, F, M AND S, AND IN | | PLACES OF RELIGIOUS WORSHIP, THE MAIN EXTERIOR DOOR OR | | DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED | | LOCKING DEVICES FROM THE EGRESS SIDE PROVIDED: | | 2.1. THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS | | LOCKED; | | 2.2. A READILY VISIBLE DURABLE SIGN IS POSTED ON THE | | EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: THIS | | DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE | | SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A | | CONTRASTING BACKGROUND; AND | | 2.3. THE USE OF THE KEY-OPERATED LOCKING DEVICE IS | | REVOKABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE. | | | | 2) SHEET A0.13 THE DOOR SCHEDULE SHOWS THE DOOR TO THE | | TRAINING ROOM, DOOR # 20 ALSO WITH A VANDAL ENTRY LOCK. | | THIS DOOR SHOULD HAVE PANIC HARDWARE IN ACCORDANCE WITH | | 1008.1.10. | | | | 3) THE DESIGNER OF RECORD INDICATES 1 HOUR FIRE RATED | | WALLS BETWEEN THE TENANT SPACE AND COMMON AREAS AS WELL | | AS THE TRAINING ROOM 707. PLEASE REVIEW THE MECHANICAL | | COMMENT # 5 MISSING FIRE DAMPERS IN FIRE RATED WALLS | | AND COMPLIANCE WITH 2014 FBC-B 714.1.1 DUCTS AND AIR | | TRANSFER OPENINGS. | | PENETRATIONS OF FIRE-RESISTANCE-RATED WALLS BY DUCTS | | THAT ARE NOT PROTECTED WITH DAMPERS SHALL COMPLY WITH | | SECTIONS 714.2 THROUGH 714.3.3. MISSING FIRE DAMPERS | | SEE M2.2.1. 10X8 O/A DUCT PENETRATING THE TRAINING/ | | CORRIDOR WALL, 16X12 O/A DUCT PENETRATING THE TRAINING | | ROOM/ CORRIDOR WALL, TRAINING ROOM/ VESTIBULE/ MENS | | RESTROOM AND THE 8X8 SUPPLY DUCT PENETRATING THE COPY | | ROOM/ ELEVATOR LOBBY WALL. | | | | 4) THE NEW OUTSIDE AIR DUCT WILL REQUIRE AN OUTSIDE AIR | | LOUVER ON THE EXTERIOR OF THE BUILDING. PLEASE PROVIDE | | COMPLIANCE WITH: 1609.6.4.4.1 COMPONENTS & CLADDING. | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE | | CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | WILL REQUIRE PRODUCT APPROVALS: | | (31(C) PANEL WALLS: WALL LOUVERS | | | | 5) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | 6) THE RESTROOM DETAIL 1/ A4.23 IN BOTH RESTROOMS SHOWS | | 6 OR MORE WATER CLOSETS AND OR COMBINATION OF WATER | | CLOSETS AND URINALS THEN COMPLIANCE WITH SECTION | | 213.3.1 OF THE 2014 ACCESSIBILITY CODE IS REQUIRED. | | ALSO SEE: | | 604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS. AMBULATORY | | ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH 604.8.2. | | 604.8.2.2 DOORS. TOILET COMPARTMENT DOORS, INCLUDING | | DOOR HARDWARE, SHALL COMPLY WITH 404, EXCEPT THAT IF | | THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT | | DOOR, CLEARANCE BETWEEN THE DOOR SIDE OF THE | | COMPARTMENT AND ANY OBSTRUCTION SHALL BE 42 INCHES | | (1065 MM) MINIMUM. THE DOOR SHALL BE SELF-CLOSING. A | | DOOR PULL COMPLYING WITH 404.2.7 SHALL BE PLACED ON | | BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET | | COMPARTMENT DOORS SHALL NOT SWING INTO THE MINIMUM | | REQUIRED COMPARTMENT AREA. | | | | 604.8.2.3 GRAB BARS. GRAB BARS SHALL COMPLY WITH 609. A | | SIDE-WALL GRAB BAR COMPLYING WITH 604.5.1 SHALL BE | | PROVIDED ON BOTH SIDES OF THE COMPARTMENT. | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2017-08-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-08-24 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-08-24 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-07-24 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-07-24 |
Time |
08:28 |
Sent To |
|
|
Notes |
2017-07-24 08:47:04 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | BASED ON REVISION PROVIDED, NEW ELECTRICAL REVIEW | | COMMENTS: | | | | 1. PANEL L1A SHOWS A 225 AMP MAIN BREAKER, WHICH | | EXCEEDS THE PERMITTED RATING PER CODE. PROVIDE | | CORRECTION. NEC TABLE 450.3(B) | | 2. PROVIDE PANEL SCHEDULE FOR BYPASS PANEL AND PANEL | | UPS. NEC 215.5, 408.4, 408.30; FBC 107.2.1 | | 3. PROVIDE SHORT CIRCUIT CALCULATIONS FOR SERVICES ON | | 1ST AND 7TH FLOOR TO CONFIRM AIC RATINGS OF PANELS IS | | SUFFICIENT, INCLUDE THE TRANSFORMER SECONDARY | | CALCULATION OF 75KVA TRANSFORMER FEEDING PANEL IT. | | PROVIDE NOTE THAT SERVICE EQUIPMENT SHALL BE MARKED PER | | NEC 110.24. NEC 110.9, 110.10, 110.24 | | 4. LOAD FOR PANEL H EXCEEDS THE OVERCURRENT PROTECTION | | AND AMPACITY OF WIRE STATED ON PLAN. PROVIDE | | CORRECTION. NEC 215.2, 215.3, 310.15(B)(16), 240.4 | | 5. PROVIDE LIGHTING CONTROL PANEL DETAIL, INCLUDE ALL | | CIRCUITS CONTROLLED BY PANEL. FBC 107.2.1, C405.2 | | 6. SHEET E3.2 AND E3.2.1, KEY NOTE #2, STATES THERE IS | | A DETAIL OF TIME CLOCK CONTACTOR C-1 ON SHEET E5.1. | | THIS DETAIL IS NOT ON ANY OF THE SHEETS. PROVIDE DETAIL | | OF ALL CONTACTOR CONTROL PANELS USED FOR RECEPTACLE | | CONTROL. REVIEWER NOTED SEVERAL CIRCUITS FROM PANELS | | NOT ON ANY OF THE CONTACTOR DETAILS PROVIDED. FBC | | 107.2.1, C405.7.1 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-06-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-06-26 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-06-26 |
Time |
14:22 |
Sent To |
|
|
Notes |
2017-06-26 14:26:24 | CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | REVISIONS NOT COLLATED BACK INTO THE SETS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-05-05 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-05-05 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-06-29 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-06-29 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-06-29 |
Time |
14:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-06-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-06-05 |
Time |
16:00 |
Sent To |
|
|
Notes |
2017-06-05 16:51:13 | 2ND REVIEW | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) COMPLIED | | | | | | 2) COMPLIED | | | | | | | | 3) DENIED - SHEET A 1.11 AND SHEETS A 5.11 & 5.12, WERE | | NOT ATTACHED TO THE RE-SUBMITTED PACKET. | | | | HOWEVER, ON REVIEW OF THE VOIDED SHEET A 5.11 THAT UL | | LISTING WAS FOUND. | | | | PLEASE ATTACHED ALL APPLICABLE SHEETS TO THE | | RESUBMITTAL. | | | | | | | | | | 4) DENIED - THE NOTE COMMENT REMIANS. THIS NOTE | | COMMENTS NEEDS TO BE REVIEWED AS THERE ARE NO FA | | DEVICES OF THE ELECTRICAL SHEETS. | | | | FA DEVICES SHALL BE INSTALLED PER NFPA 72 UNDER | | SEPARATE SHOP DRAWINGS. | | | | | | PLEASE CORRECT.. | | | | | | | | 5) DENIED - THE "NOT" SHALL BE PLACED AFTER THE SHALL. | | CARD READERS SHALL "NOT" DELAY OR INTERFERE WITH ANY | | EXIT DOOR AND SHALL COMPLY WITH NFPA 101, CHAPTER 7, | | MEANS OF EGRESS AND SHALL BE INSTALLED UNDER SEPARATE | | SHOP DRAWINGS. | | | | PLEASE CORRECT. | | | | | | | | 6) COMPLIED | | | | | | | | 7) COMPLIED | | | | | | | | 8) COMMENT REMAINS - WHEN RESUBMITTING, PLEASE PROVIDE | | PLAN SHEET REVISION CLOUDS OR NUMBERED NARRATIVE | | RESPONSES TO THE ABOVE. | | | | | | | | 9) COMMENT REMAINS - ADDITIONAL COMMENTS MAY BE | | PROVIDED ON THE RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-04-12 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-04-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-04-11 |
Time |
15:19 |
Sent To |
|
|
Notes |
2017-04-11 16:51:25 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) | | SHEET A 0.01 - THERE INCORRECT REFERENCES INDICATED FOR | | THE CURRENT EDITIONS OF THE FLORIDA FIRE PREVENTION | | CODE. | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | APPLICABLE CODES OR STANDARDS. | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 13, 2010 EDITION. | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 72, 2010 EDITION. | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | NFPA 241, 2009 EDITION. | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | OF NFPA 10, 2010 EDITION. | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL COMPLY WITH | | NFPA 110, 2013 EDITION. | | AIR CONDITION WORK SHALL COMPLY WITH NFPA 90 A & B, | | 2012 EDITION | | | | PLEASE CORRECT ALL THE APPLICABLE CODE EDITIONS. | | | | | | | | 2) | | SHEETS A 0.0. & 0.03 - NOTE # 7 MAKES REFERENCE TO AND | | INCORRECT NFPA 13 EDITION. | | | | PLEASE CORRECT AS NOTED ON # 1 ABOVE. | | | | | | | | | | 3) | | SHEET A 1.11 - THERE ARE INDICATIONS OF WALL TYPE | | REFERENCE OF A BOX AROUND, S1, TO WALLS CONTAINING FIRE | | RATED DOORS. ON SHEETS A 5.11 & 5.12 THERE ARE NO | | INDICATORS MATHCING THAT REFERENCE OR ANY OTHER LISTED | | WALL RATING. | | | | PLEASE PROVIDE THE APPLICABLE LISTED WALL RATING FOR | | THAT REFERENCE. | | | | | | | | | | 4) | | SHEET A 0.02 & 0.03 - NOTE # 4 INDICATES REFERNCES TO | | LIFE SAFETY DEVICES ON THE ELECTICAL SHEETS. THERE ARE | | NO INDICATORS OF ANY FIRE ALARM DEVICES ON ANY | | ELECTICAL SHEET. | | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE | | UNDER SEPARATE SHOP DRAWINGS AND BY CERTIFIED LIFE | | SAFETY CONTRACTORS. | | | | THE FIRE ALARM SYSTEM SHALL REMAIN ACTIVE THROUGHOUT | | THE CONSTRUCTION PERIOD. | | | | PLEASE PROVIDE AN APLLICABLE NOTE. | | | | | | | | 5) | | SHEET E - THE ELECTRICAL SHEETS INDICATE CARD READERS | | ON EXIT DOORS. THESE CARD READERS SHALL DELAY OR | | INTERFERE WITH ANY EXIT DOOR AND SHALL COMPLY WITH NFPA | | 101, CHAPTER 7, MEANS OF EGRESS AND SHALL BE INSTALLED | | UNDER SEPARATE SHOP DRAWINGS. | | | | PLEASE PROVIDE AN APPLICABLE NOTE. | | | | | | | | 6) | | SHEET A 0.01 - NOTE # 7 REFERENCES WORK ON THE FIRE | | SPRINKLER SYSTEMS. THE FIRE SPRINKLER SHALL REMAIN | | ACTIVE THROUGHOUT THE CONSTRUCTION PERIOD. ANY TIME | | THAT WORK ON THE FIRE SPRINKLER SYSTEM EXCEEDS 4 HOURS, | | A FIRE WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL | | FULL AND COMPLETE PROTECTION IS RETURNED. | | | | PLEASE PROVIDE AND APPLICABLE NOTE. | | | | | | 7) | | SHEET A 0.02 & 0.03 - FOR INFORMATIONAL PURPOSES, THERE | | IS A MISSPELLED WORD; "OCCUYPANCY", INDICATED IN THE | | TABLE HEADER. | | | | | | | | 8) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 9) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-09-27 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-09-27 |
Time |
|
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-09-19 |
Time |
17:56 |
Sent To |
|
|
Notes |
2017-09-19 17:56:21 | GJOHNSON'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-08-28 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-07-31 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-07-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-24 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-26 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-06-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-06-26 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-06-01 |
Time |
08:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-05-10 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-04-05 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-05-10 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-05-10 |
Time |
07:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-08-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-30 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-08-30 |
Time |
10:46 |
Sent To |
|
|
Notes |
2017-08-30 11:12:57 | MECHANICAL PROVISO; | | | | PROVIDE A COMMISSIONING REPORT FOR THE REPLACED | | SYSTEMS. | | | | CCOLE- 8/30/17 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-07-24 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-07-24 |
Time |
10:13 |
Sent To |
|
|
Notes |
2017-07-24 10:25:38 | 3RD REVIEW FBC-2014 MECHANICAL | | PERMIT #17040199 | | 7/24/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THIRD REQUEST FOR AC COOLING AND HEATING | | CALCULATONS- SECTION C403.2.1 FBC-14 ENERGY | | CONSERVATION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-06-12 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-06-12 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-06-12 |
Time |
16:14 |
Sent To |
|
|
Notes |
2017-06-12 16:25:22 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17040199 | | 6/12/17 | | | | 1) THE REQUESTED COOLING AND HEATING CALCULATIONS FOR | | THE HEAT PUMPS WERE NOT SUBMITTED- PLEASE COMPLY | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-04-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-04-11 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-04-11 |
Time |
09:11 |
Sent To |
|
|
Notes |
2017-04-11 09:14:16 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17040199 | | 4/11/17 | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | NEW HEAT PUMPS- SECTION C403.2.1 FBC-14 ENERGY | | CONSERVATION | | | | 2) PROVIDE EQUIPMENT SCHEDULES FOR EF-1 & 2. | | | | 3) PROVIDE EXHAUST VENTILATION CALCULATIONS FOR THE | | WOMEN'S AND MEN'S RESTROOMS. | | | | 4) M6.2: PLEASE CLARIFY HOW THE O/A UNITS WERE SIZED | | AND FOR WHAT AREAS THEY ARE SERVING. | | | | 5) M2.21: MISSING FIRE DAMPERS- A) 10X8 O/A DUCT | | PENETRATING THE TRAINING/CORRIDOR WALL. B) 16X12 O/A | | DUCT PENETRATING THE TRAINING/CORRIDOR WALL, AND THE | | TRAINING/VESTIBULE/MEN'S RESTROOM WALLS. C) 8X8 SUPPLY | | DUCT PENETRATING THE COPY ROOM/ELEVATOR LOBBY WALL. | | | | 6) SUBMIT AN APPROVED FL. PRODUCT APPROVAL AND/OR | | MIAMI-DADE NOA FOR THE LOUVERS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-09-22 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-09-22 |
Time |
11:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2017-08-30 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-08-30 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-08-29 |
Time |
08:18 |
Sent To |
|
|
Notes |
2017-08-30 09:51:25 | 1) PROVIDE A FIRESTOPPING DETAIL FOR PVC PIPE THROUGH | | FIRE RATED WALLS. THE PIPE FIRESTOPPING DETAILS ON | | SHEET A0.05 ARE ONLY FOR FERRROUS AND NON-FERROUS PIPE. | | 2014 FBC SEC. 714.3.1. | | 2) THE WALL FINISH AROUND THE MOP/SERVICE SINK SHALL | | COMPLY WITH THE 2015 FBC SEC.1210.2.2. | | 3) SHT. A4.23 - THE DOORS ON THE AMBULATORY ACCESSIBLE | | STALLS IN THE MEN'S AND WOMEN'S RESTROOMS SHALL NOT | | SWING INTO THE MINIMUM REQUIRED COMPARTMENT AREA. 2014 | | FBC-ACCESS. SEC. 604.8.2.2. | | 4) SHT.A4.23 - DETAIL #1 - ENLARGED TOILET ROOM - THE | | HANDICAPPED ACCESSIBLE TOILET STALLS SHOW THE WATER | | CLOSETS AT 1'-7" FROM THE ADJACENT WALL TO THE | | CENTERLINE OF THE WATER CLOSET. THE WATER CLOSETS SHALL | | BE LOCATED 16 INCHES MINIMUM TO 18 INCHES MAXIMUM TO | | THE SIDE WALL. | | 2014 FBC-ACCESS. SEC.604.2. | | 5) SHT. A4.23 - DETAIL #3 - NOTE ON THE PLAN THAT THE | | SHOWER CONTROLS SHALL BE LOCATED 15 INCHES MAXIMUM FRON | | THE CENTERLINE OF THE SEAT TOWARD THE SHOWER | | OPENING.2014 FBC-ACCESS SEC.608.5.1. | | 6) A FIXED SHOWER HEAD LOCATED 48 INCHES MAXIMUM ABOVE | | THE SHOWER FINISH FLOOR SHALL BE PERMITTED INSTEAD OF A | | HAND-HELD SPRAY UNIT PER 2014 FBC-ACCESS SEC.608.6. | | SHOW COMPLIANCE ON THE PLANS OR SUPPLY A SHOWER SPRAY | | UNIT IN COMPLIANCE WITH 2014 FBC-ACCESS. SEC. 608.6. | | 7) SHT. P0.1 - WATER HEATER DETAIL - DELETE THE | | REFERENCE TO THE RELIEF LINE BEING PIPED TO THE | | EXTERIOR AND CHANGE THE CODE TO 2014 FBC, NOT 2010. | | 8) SHT. P5.1 - SANITARY RISER - WHERE DOES THE VENT FOR | | THE THE DRINKING FOUNTAIN/SK-1 / MOP SINK TERMINATE? | | WHERE IS THE VENT THROUGH THE ROOF? THIS ALSO OCCURS ON | | THE VENT FOR THE GANG TOILETS. CLARIFY. | | 9) SUBMIT AN EXPANDED SANITARY AND WATER RISER FOR | | REVIEW. A COMPREHENSIVE REVIEW CANNOT BE DONE AS THE | | DRAWING IS TOO CCOMPRESSED. WPB AMEND. TO FBC SEC. | | 107.2.1. | | 10) SHT.P5.1 - THE SANITARY RISER SHOWS 6 LAVATORIES IN | | A ROW IN THE MEN'S RESTROOM AND THE FLOOR PLAN ON P | | 2.2.1 SHOWS 5 LAVATORIES. CLARIFY. 11) | | 11) THE SANITARY RISER FOR THE MEN''S & WOMEN'S | | RESTROOM DOES NOT COMPLY WITH 2014 FBC-PLUMBING | | SEC.914.1, 914.2 FOR A CIRCUIT VENT. CLARIFY. | | 12) SIZE THE TYPICAL VENT STACK FFOR THE LAVATORIES ON | | THE SANITARY RISER.COMPLY WITH 2014 FBC-PLUMBING | | SEC.906.1 & TABLE 906.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2017-07-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-24 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-24 |
Time |
10:32 |
Sent To |
|
|
Notes |
2017-07-24 12:41:25 | 3RD REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | | | 3RD REQUEST PREVIOUS COMMENT NOT COMPLIED 2. PER FBC | | ACC 213.3.1 AT LEAST ONE OF THE TOILET COMPARTMENTS IN | | EACH BATHROOM SHALL BE AN AMBULATORY STALL PER FBC | | 604.8.2 ( YOU ARE MISSING THE GRAB BARS) | | 213.3.1 TOILET COMPARTMENTS. | | WHERE TOILET COMPARTMENTS ARE PROVIDED, AT LEAST ONE | | TOILET COMPARTMENT SHALL COMPLY WITH 604.8.1. IN | | ADDITION TO THE COMPARTMENT REQUIRED TO COMPLY WITH | | 604.8.1, AT LEAST ONE COMPARTMENT SHALL COMPLY WITH | | 604.8.2 WHERE SIX OR MORE TOILET COMPARTMENTS ARE | | PROVIDED, OR WHERE THE COMBINATION OF URINALS AND WATER | | CLOSETS TOTALS SIX OR MORE FIXTURES. | | THIS CODE REQUIREMENT IS FOR THE FIXTURES PROVIDED NOT | | FIXTURES REQUIRED. | | | | NEW COMMENT | | 1. SHT.4.23 DETAIL #1 THE DIMENSION FOR THE DEPTH OF | | THE TRANSFER SHOWER IS AN EXACT MEASUREMENT NOT A MIN | | PLEASE CLARIFY. PER FBC ACC 608.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-06-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-06-23 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-23 |
Time |
12:52 |
Sent To |
|
|
Notes |
2017-06-23 12:56:44 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | | | PREVIOUS COMMENT NOT COMPLIED 2. PER FBC ACC 213.3.1 AT | | LEAST ONE OF THE TOILET COMPARTMENTS IN EACH BATHROOM | | SHALL BE AN AMBULATORY STALL PER FBC 604.8.2 | | 213.3.1 TOILET COMPARTMENTS. | | WHERE TOILET COMPARTMENTS ARE PROVIDED, AT LEAST ONE | | TOILET COMPARTMENT SHALL COMPLY WITH 604.8.1. IN | | ADDITION TO THE COMPARTMENT REQUIRED TO COMPLY WITH | | 604.8.1, AT LEAST ONE COMPARTMENT SHALL COMPLY WITH | | 604.8.2 WHERE SIX OR MORE TOILET COMPARTMENTS ARE | | PROVIDED, OR WHERE THE COMBINATION OF URINALS AND WATER | | CLOSETS TOTALS SIX OR MORE FIXTURES. | | THIS CODE REQUIREMENT IS FOR THE FIXTURES PROVIDED NOT | | FIXTURES REQUIRED. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-05-04 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-05-03 |
Time |
16:41 |
Sent To |
|
|
Notes |
2017-05-04 11:25:35 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. A MIN OF ONE URINAL SHALL BE ACCESSIBLE PER FBC ACC | | 213.3.3 PLEASE SHOW ACCESSIBILITY PER FBC ACC 605.2 AND | | 605.3 | | | | 2. PER FBC ACC 213.3.1 AT LEAST ONE OF THE TOILET | | COMPARTMENTS IN EACH BATHROOM SHALL BE AN AMBULATORY | | STALL PER FBC 604.8.2 | | | | 3. PLEASE PROVIDE ELEVATION DIMENSIONS FOR THE SHOWER | | CONTROLS AND THE SEAT. PER FBC ACC 608.5.1 AND 610.3 | | AND 610.3.2 | | | | 4. SHT. P5.1 ON THE SANITARY RISER THE CIRCUIT VENT | | SHALL BE CONNECTED BETWEEN THE TWO HWC PER FBC PL 914.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|