Plan Review Details - Permit 17040081
Plan Review Stops For Permit 17040081 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-04-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-13 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2017-04-13 15:15:37 | PROVISO - SUBMIT ORIGINAL ENGINEERING | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-04-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-13 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-13 |
Time |
12:43 |
Sent To |
|
|
Notes |
2017-04-13 12:54:46 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. SCOPE NOT CLEAR. SEE PREVIOUS LIST; WORST CASE | | DESIGN PRESSURES ARE FOR ZONES 6 AND 7. THEY WERE NOT | | INCLUDED IN THE ENGINEERING. A ROOF PLAN WAS SUBMITTED | | WITH PORTIONS HIGHLIGHTED. ZONES 2 AND 3 ARE NOT | | HIGHLIGHTED FOR TWO LARGE PORTIONS OF ROOF AREA. DOES | | THIS MEAN YOU PROPOSE TO REROOF ONLY A PORTION OF THE | | ROOF, AND LEAVING THE EDGES AND CORNERS? DOESN'T THIS | | PROJECT INCLUDE AN ADDITION? FOR THE ADDITION AREA, | | ONLY ZONE 1 WAS HIGHLIGHTED. | | | | REVISE THE ROOF PLAN TO INCLUDE A LEGEND AS THE | | HIGHLIGHTING IS NOT CLEAR AS TO WHAT IT REPRESENTS. AS | | A PORTION IS OVER THE ADDITION, ALL ZONES (1, 2, 3) ARE | | REQUIRED. AS THE REROOF PORTION IS OVER 25% OF THE | | ROOF, A COMPLETE REROOF (ZONES 1, 2, 3) IS REQUIRED, | | FBC EB 708.1.1. | | | | 2. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | FS471. | | | | (RAS117 CALCULATIONS CHECKED AND ARE OK) | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-04-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-05 |
Time |
06:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-05 |
Time |
06:46 |
Sent To |
|
|
Notes |
2017-04-05 06:51:10 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. THE ASSEMBLY PROPOSED HAS A DP OF -52.5 (GENERAL | | LIMITATION #9, CANNOT BE INCREASED). SEE PAGE S0.2, | | WORST CASE APPEARS TO BE -128.8, SEE SHEET S0.2, FBC | | 1609. (NOT ENTIRELY CLEAR AS "ULTIMATE" AND "ALLOWABLE" | | PRESSURES FOR ZONES 6 AND 7 ARE THE SAME) | | | | 2. PRODUCT APPROVALS AND ASSEMBLY PROPOSED ARE TO BE | | REVIEWED BY DESIGNER OF RECORD PRIOR TO SUBMITTAL, FBC | | 107. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-04-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-13 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-10 |
Time |
13:32 |
Sent To |
|
|
Notes |
2017-04-11 13:32:23 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-04-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-06 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-04 |
Time |
15:29 |
Sent To |
|
|
Notes |
|
|
|