Plan Review Details - Permit 17030682
Plan Review Stops For Permit 17030682 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-04-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-04-13 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-04-13 |
Time |
09:33 |
Sent To |
|
|
Notes |
2017-04-13 09:34:04 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC 107.2.1.3 THE ENGINEER NEEDS TO SPECIFY THE | | FOLLOWING INFORMATION ON THE DRAWINGS: | | A) THE SIZE AND THICKNESS OF THE LEXAN PANELS | | B) THE TYPE OF MATERIAL (IE. STAINLESS STEEL, ETC.) AND | | LENGTH OF THE 5/16" DIA. SELF DRILLING SCREWS | | C) THE REQUIRED WINDLOAD PRESSURES FOR THE OPENINGS | | | | 2) THIS WORK IS BEYOND THE SCOPE OF A ROOFING | | CONTRACTOR. A SEPARATE SUB-PERMIT FROM AN APPROPRIATELY | | LICENSED CONTRACTOR IS REQUIRED. FS 489 | | | | 3) THE INSTALLATION OF THIS SYSTEM WILL ONLY BE | | ACCEPTED FOR THE UNITS WITH AN OPEN COVERED BALCONY. AN | | APPROVED WINDOW ASSEMBLY WITH A CURRENT FLORIDA OR | | MIAMI-DADE PRODUCT APPROVAL IS REQUIRED FOR THE UNITS | | THAT HAVE ENCLOSED BALCONIES. FS553.842 & FAC 61G-3.001 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-03-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-03-21 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-03-21 |
Time |
17:32 |
Sent To |
|
|
Notes |
2017-03-21 17:32:17 | DENIED BY BUILDING | | | | 1) NEED ADDITIONAL INFORMATION TO CLEARLY DETERMINE THE | | SCOPE OF WORK AND THAT IT WILL BE CODE COMPLIANT. FBC | | 107.2.1 | | 2) THE INSTALLATION OF SCREENS AND FRAMES IS NOT | | INCLUDED IN THE WORK OF A ROOFING CONTRACTOR. FS 489 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-04-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-04-13 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-04-03 |
Time |
15:32 |
Sent To |
|
|
Notes |
2017-04-04 15:33:01 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-03-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-03-21 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-03-16 |
Time |
13:53 |
Sent To |
|
|
Notes |
2017-03-17 13:53:37 | REVISION ROUTED TO RMCDOUGAL |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |