|
 |
 |
 |
 |
 |
Plan Review Details - Permit 17030643
Plan Review Stops For Permit 17030643 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-04-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-14 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-14 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-03-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-03-23 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-03-23 |
Time |
16:39 |
Sent To |
|
|
Notes |
2017-03-23 16:46:23 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. ADDRESS MECHANICAL COMMENTS (SMOKE CONTROL); FBC | | 107. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-04-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-14 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-04-10 |
Time |
16:12 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-03-22 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-03-22 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-03-22 |
Time |
16:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2017-03-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-03-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-03-21 |
Time |
12:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-04-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-14 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-07 |
Time |
10:32 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-03-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-03-23 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-03-15 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2017-03-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-03-23 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-03-23 |
Time |
16:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-04-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-04-11 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-04-11 |
Time |
16:29 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-03-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-21 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-03-21 |
Time |
16:27 |
Sent To |
|
|
Notes |
2017-03-21 16:37:05 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17030643 | | 3/21/17 | | | | 1) M-1: THE PLAN IS INDICATING AN ALTERATION TO AN | | EXISTING SMOKE CONTROL SYSTEM HOWEVER IT DOES NOT | | APPEAR THAT THE CORRIDORS ARE ENCLOSED WITH PROPERLY | | CONSTRUCTED SMOKE BARRIERS IN ACCORDANCE WITH SECTIONS | | 709 AND 909.5 FBC-14 BUILDING. PLEASE INDICATE THE | | MINIMUM PRESSURE DIFFERENCE REQUIRED ACROSS THE SMOKE | | BARRIER AND CLARIFY IF A RATIONAL ANALYSIS WAS USED TO | | ESTABLISH THE REQUIRED PRESSURES, AND TO ALSO SIZE THE | | DUCTS AND DIFFUSERS PROVIDING THE AIR- SEE SECTIONS | | 909.4 AND 909.6. | | | | 2) M-1: THE PLAN SHOWS SOME INCONSISTENCIES IN FLEX | | DUCT SIZING FOR THE DIFFUSERS SUPPLYING 250 AND 225 | | CFMS. IN SOME ROOMS AND SPACES AN 8" DUCT IS USED, AND | | IN OTHERS A 10" DUCT. | | | | 3) THE ENERGY FORM C402 MUST BE SIGNED AND DATED BY THE | | OWNER/AGENT. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-03-17 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-17 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-17 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |