Plan Review Details - Permit 17030438
Plan Review Stops For Permit 17030438
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-05-12 Cont ID  
Sent By jwitmer Date 2017-05-12 Time 16:36 Rev Time 0.00
Received By jwitmer Date 2017-05-12 Time 14:58 Sent To  
Notes
2017-05-12 16:36:06BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17030438
 ADD: 1 HARVARD CIRCLE
 CONT: FISHER CONTRACTING
 TEL: 561-691-4716
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. MAY 12/ 2017
 ACTION: BUILDING PROVISO
  
 1) DEFERRED SUBMITTAL; 2014 FBC-B 1609.6.4.4.1
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS ,SWING AND ROLL UP TYPE GARAGE
 DOORS.
 (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP
 INSULATION INCLUDED.
  
 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR
 TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL
 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 2) DEFERRED SUBMITTAL. EXTERIOR DOOR PRODUCT SUBMITTALS
 WILL BE IN CONFORMANCE WITH THE ENERGY REQUIREMENTS.
 THEY SHALL BE REVIEWED BY THE DESIGNER OF RECORD,
 STAMPED APPROVED AND SUBMITTED TO THE AHJ PRIOR TO
 INSTALLATION. PLEASE PROVIDE REPORTS FOR ALL DOORS
 SHOWING THEY WILL MEET THE ENERGY REQUIREMENTS OF R2.85
 FOR BOTH THE SWING DOORS AND ROLLUP DOOR. TOTAL
 BUILDING PERFORMANCE COMPLIANCE OPTION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-23 Cont ID  
Sent By jwitmer Date 2017-03-23 Time 16:46 Rev Time  
Received By jwitmer Date 2017-03-23 Time 15:30 Sent To  
Notes
2017-03-23 16:25:02BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17030438
 ADD: 1 HARVARD CIRCLE
 CONT: FISHER CONTRACTING
 TEL: 561-691-4716
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. MARCH 23/ 2017
 ACTION: DENIED
  
 1) PLEASE PROVIDE A SOILS REPORT SINCE THIS IS A
 QUESTIONABLE SOILS AREA. 2014 FBC-B 1803.5.3.
 QUESTIONABLE SOILS.
  
 2) SHEET S0.0 THE WIND DESIGN INDICATES THIS IS A B
 EXPOSURE TO THE NORTHEAST AND THE SURFACE ROUGHNESS IS
 CONSIDERED A C EXPOSURE. FBC-B 1609.4.2 EXPOSURE
 CATEGORIES. THIS SURFACE ROUGHNESS SHALL ALSO APPLY TO
 ANY BUILDING LOCATED WITHIN SURFACE ROUGHNESS B TYPE
 TERRAIN WHERE THE BUILDING IS WITHIN 100 FEET
 HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF SURFACE
 ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE THAN
 600 FEET.
  
 3) WITH THE WIND DESIGN CLASSIFICATION FROM B TO C
 EXPOSURE WILL INCREASE THE PRESSURES FOR ROOF ZONES
 1,-3 AND WALL ZONES 4 & 5. 2014 FBC-B TABLE 1609.7.2.
 HEIGHT AND EXPOSURE.
  
 4) PLEASE SHOW COMPLIANCE WITH 2014 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS,
 ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS ,SWING AND ROLL UP TYPE GARAGE
 DOORS.
 (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP
 INSULATION INCLUDED.
  
 5) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
 6) PLEASE PROVIDE REPORTS FOR ALL DOORS SHOWING THEY
 WILL MEET THE ENERGY REQUIREMENTS OF R2.85 FOR BOTH THE
 SWING DOORS AND ROLLUP DOOR. TOTAL BUILDING PERFORMANCE
 COMPLIANCE OPTION.
  
 7) BOTH THE ARCHITECTURAL AND STRUCTURAL SHEETS SHOW
 THE USE OF BAR JOIST AND METAL DECKING. THE CONTRACTOR
 IS REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION.
 2014 FBC-B 2204.1 WELDING
 2014 FBC-B 2204.2 BOLTING.
  
 8) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY.
 THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-04-25 Cont ID  
Sent By jleahy Date 2017-04-25 Time 07:43 Rev Time 0.00
Received By jleahy Date 2017-04-25 Time 07:43 Sent To  
Notes
2017-04-25 07:44:54BEFORE FINAL INSPECTION
  
 SHOW SIZE OF MAIN ON LINE SIDE OF TRANSFORMER, FUSE OR
 BREAKER?
 FAULT CURRENT AT THIS MAIN.
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 BN1165, BU1753, PX163
 561-805-6713
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-03-29 Cont ID  
Sent By jleahy Date 2017-03-29 Time 07:04 Rev Time 0.00
Received By jleahy Date 2017-03-29 Time 07:04 Sent To  
Notes
2017-03-29 07:14:38CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION
  
  
 NEED TO SHOW LOCATION OF THE METER, IS METER CT OR
 VOLTAGE.
 FAULT CURRENT CALCULATION AND SIGNAGE NEC 110.24(A)(B)
 NO GROUNDING SHOWN FOR THE SERVICE.
 ENERGY CALCULATION FBC EC C405.5.2
  
  
 JAKE LEAHY
 ELECTRICAL INSPECTOR II
 561-805-6713
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2017-05-23 Cont ID  
Sent By Mgonzale Date 2017-05-23 Time   Rev Time 1.00
Received By mgonzale Date 2017-05-23 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2017-04-20 Cont ID  
Sent By Mgonzale Date 2017-04-20 Time   Rev Time  
Received By mgonzale Date 2017-04-20 Time   Sent To Z
Notes
2017-04-20 15:10:13ADDRESS PLANNING COMMENTS.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-05-18 Cont ID  
Sent By pleduc Date 2017-05-18 Time   Rev Time 0.00
Received By pleduc Date 2017-05-17 Time 14:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-03-15 Cont ID  
Sent By pleduc Date 2017-03-15 Time   Rev Time 0.00
Received By pleduc Date 2017-03-14 Time 12:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-05-24 Cont ID  
Sent By lmarchan Date 2017-05-24 Time 15:51 Rev Time 0.00
Received By lmarchan Date 2017-04-20 Time 12:10 Sent To  
Notes
2017-04-21 12:10:49C23

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-04-21 Cont ID  
Sent By lmarchan Date 2017-04-21 Time 12:10 Rev Time 0.00
Received By lmarchan Date 2017-03-10 Time 17:12 Sent To  
Notes
2017-03-10 17:13:58C23

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2017-05-12 Cont ID  
Sent By jwitmer Date 2017-05-12 Time 15:00 Rev Time 0.00
Received By jwitmer Date 2017-05-12 Time 14:58 Sent To  
Notes
2017-05-12 15:00:17PALM BEACH COUNTY IMPACT FEES
 MU--2017-011358-0000
 RECEIPT NO. 2017-0502-92
 FEES; $35.62

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-03-23 Cont ID  
Sent By jwitmer Date 2017-03-23 Time 16:25 Rev Time  
Received By jwitmer Date 2017-03-23 Time 15:30 Sent To  
Notes
2017-03-23 15:44:23IMPACT FEES
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-04-27 Cont ID  
Sent By ccole Date 2017-04-26 Time 10:23 Rev Time 0.00
Received By ccole Date 2017-04-26 Time 10:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-03-24 Cont ID  
Sent By ccole Date 2017-03-24 Time 09:11 Rev Time 0.00
Received By ccole Date 2017-03-24 Time 08:41 Sent To  
Notes
2017-03-24 09:19:301ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17030438
 3/24/17
  
 1) SHEET M0.1: PROVIDE THE DEPTH OF EMBEDMENT FOR THE
 CU WEDGE ANCHOR BOLTS.
  
 2) M0.1: THE DRYBULB AND WETBULB TEMPERATURES IN THE
 HVAC DESIGN CONDITIONS TABLE ARE INCORRECT FOR WEST
 PALM BEACH PER ACCA MANUAL N. FROM WHICH STANDARD WERE
 THESE TEMPERATURES DERIVED?
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-05-22 Cont ID  
Sent By gjohnson Date 2017-05-22 Time 17:07 Rev Time 0.00
Received By gjohnson Date 2017-05-22 Time 13:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-04-07 Cont ID  
Sent By gjohnson Date 2017-04-07 Time 17:18 Rev Time 0.00
Received By gjohnson Date 2017-04-07 Time 17:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2017-05-17 Cont ID  
Sent By jroach Date 2017-05-17 Time 12:02 Rev Time 0.00
Received By jroach Date 2017-05-17 Time 11:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2017-05-04 Cont ID  
Sent By jroach Date 2017-05-04 Time 11:02 Rev Time 0.00
Received By jroach Date 2017-05-04 Time 11:02 Sent To  
Notes
2017-05-04 11:03:07ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 05.04.2017
 PERMIT NO.: 17030438
 ADDRESS: 1 HARVARD CIRCLE
 CONTRACTOR/CONTACT: JEFF FISHER
 TELEPHONE NO.: 561.691.4716
 SCOPE OF REVIEW: NEW STORAGE BUILDING
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A MINOR
 AMENDMENT TO THE VILLAGE COMMERCE CENTER COMMERCIAL
 PLANNED DEVELOPMENT (CPD) SHALL BE APPROVED. SUCH
 APPLICATION HAS ALREADY BEEN SUBMITTED (BY RYAN
 JOHNSTON OF JOHNSTON GROUP DEVELOPMENT & DESIGN). ONCE
 THE MINOR AMENDMENT IS APPROVED, ALL BUILDING PERMIT
 PLANS SHALL MATCH THOSE THAT WERE APPROVED.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2017-04-04 Cont ID  
Sent By jroach Date 2017-04-04 Time 13:17 Rev Time 0.00
Received By jroach Date 2017-04-04 Time 13:13 Sent To  
Notes
2017-04-04 13:17:30ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 04.04.2017
 PERMIT NO.: 17030438
 ADDRESS: 1 HARVARD CIRCLE
 CONTRACTOR/CONTACT: JEFF FISHER
 TELEPHONE NO.: 561.691.4716
 SCOPE OF REVIEW: NEW STORAGE BUILDING
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A MINOR
 AMENDMENT TO THE VILLAGE COMMERCE CENTER COMMERCIAL
 PLANNED DEVELOPMENT (CPD) SHALL BE APPROVED. SUCH
 APPLICATION HAS ALREADY BEEN SUBMITTED (BY RYAN
 JOHNSTON OF JOHNSTON GROUP DEVELOPMENT & DESIGN). ONCE
 THE MINOR AMENDMENT IS APPROVED, ALL BUILDING PERMIT
 PLANS SHALL MATCH THOSE THAT WERE APPROVED.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved