Plan Review Stops For Permit 17030213 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-06-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-06-07 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-06-07 |
Time |
06:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-05-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-05-30 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-05-30 |
Time |
18:28 |
Sent To |
|
|
Notes |
2017-06-07 06:47:37 | IMAGE OF SIGNATURE NOT AN ISSUE PER FBPE | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-04-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-04 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-04 |
Time |
10:00 |
Sent To |
|
|
Notes |
2017-04-04 12:54:33 | 4/4/17 ****PENDING RESPONSE FROM FBPE**** AN EMAIL WAS | | SENT TO FBPE REGARDING THE IMAGE OF THE ENGINEER'S | | SIGNATURE ON THE DIGITAL PLAN PAGES. PER FBPE IN | | PREVIOUS CONVERSATIONS, THIS IS NOT PERMITTED PER | | FAC61G15-23. THEREFORE I SENT AN INQUIRY FOR | | CLARIFICATION. | | | | 5/30/17: THE RESPONSE FROM FBPE VIA TELEPHONE: NO, AN | | IMAGE OF A SIGNATURE IS NOT CURRENTLY PERMITTED PER | | FAC61G15-23. HOWEVER, FBPE IS IN THE PROCESS OF | | AMENDING THIS SECTION SO THAT THE IMAGE IS ALLOWED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-04-17 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-04-17 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-04-17 |
Time |
08:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-06-08 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-06-08 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-06-08 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2017-04-05 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-04-05 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-04-05 |
Time |
13:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-06-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-06-27 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-06-06 |
Time |
16:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-05-16 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-05-16 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-03-31 |
Time |
16:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-06-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-06-27 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-06-27 |
Time |
10:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2017-05-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-05-16 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-05-16 |
Time |
09:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-06-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-06-20 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-06-20 |
Time |
09:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-06-13 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-06-13 |
Time |
04:43 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-06-13 |
Time |
03:57 |
Sent To |
|
|
Notes |
2017-06-13 04:41:02 | 1) SUBMIT A COMPLETE WATER AND SANITARY RISER DIAGRAM | | FOR THE COMBINED UNIT "F".WPB AMEND. TO FBC SEC. | | 107.3.5.1.3. | | 2) SUBMIT A FLOOR PLAN SHOWING THE LOCATION OF "UNIT | | F". I LOOKED AT ALL THE FLOOR PLANS SUBMITTED ON THE | | ARCHITECTURAL SHEETS FOR THIS REVISION AND COULD NOT | | FIND ONE THAT SHOWED THE LOCATION OF THIS UNIT.IT IS | | VERY CONFUSING. WPB AMEND. TO FBC SEC. 107.2.1.WHAT | | UNITS/AREAS WERE COMBINED TO FORM UNIT F? INDICATE ON | | THE ENLARGED PLANS FOR UNIT F. WPB AMEND. TO FBC SEC. | | 107.2.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-05-04 |
Time |
05:44 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-04-28 |
Time |
11:07 |
Sent To |
|
|
Notes |
2017-04-28 11:08:20 | 1) SUBMIT AN EXPLANATION AS TO THE EXACT CHANGES THAT | | WERE DONE TO THE PLUMBING SHEETS ON THE SUMMARY OF | | ITEMS DOCUMENT THAT WAS SUBMITTED.WPB AMEND. TO FBC | | SEC. 107.2.1 | | 2) .SUBMIT REVISED SANITARY AND WATER RISER DIAGRAMS | | FOR ALL CHANGES MADE TO THE PLUMBING SYSTEMS UNDER THIS | | REVISION. WPB AMEND. TO FBC SEC. 107.3.5.1.3. | | 3) SUBMIT AN EXPLANATION AS TO THE EXACT CHANGES THAT | | WERE DONE TO THE DRAINAGE SYSTEM ON SHT.# C103. | | 4) THE SUBMITTED NARRRATIVE FOR THIS REVISION PROVIDES | | NO CLEAR EXPLANATION AS TO THE CHANGES THAT HAVE BEEN | | DONE TO EACH SHEET. PROVIDE A NARRATIVE THAT CLEALY | | DESCRIBES THE CHANGES THAT HAVE BEEN MADE TO EACH PLAN | | AND THOSE CHANGES SHALL BE CLEARLY IDENTIFIED ON THE | | PLANS.WPB AMEND. TO FBC SEC. 107.2.1. | | 5) PLACE INFORMATION ON THE ARCHITECTURAL PLANS THAT | | THIS IS PHASE ONE OF THE PROJECT. WPB AMEND. TO FBC | | SEC. 107.2.1. | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE SOLIDS | | INTERCEPTOR. WPB AMEND. TO FBC SEC. 107.2.1. | | 7) SHT. P413 - THE SINK AT THE OUTDOOR KITCHEN SHALL | | DISCHARGE INDIRECTLY TO THE GI-2 INTERCEPTOR PER 2010 | | FBC SEC.802.1.8. | | 8) SHT. P413 - KITCHEN EQUIPMENT (ICE, COFFEE, STEAMER, | | BEVERAGE DISPENSER) SHALL BE EQUIPPED WITH BACKFLOW | | PREVENTERS PER 2010 FBC-PLUMBING SECS.608.16.1, | | 608.16.10. | | | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2017-06-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-06-07 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-06-07 |
Time |
08:57 |
Sent To |
|
|
Notes |
2017-06-07 08:59:20 | SAMANTHA HILL | | 561-805-6724 | | [email protected] | | | | ALL SHEETS, ALL TRADES HAVE BEEN VERIFIED AND COMPLY | | WITH FS471 / FS481. | | | | AFTER ALL PLAN REVIEWS ARE COMPLETE: | | | | IF ALL REVIEWS PASS, CONTACT ME TO CHANGE "FAIL" STATUS | | TO "PASS". | | | | IF ANY REVIEWS FAIL PLAN REVIEW, A NEW SIGNATURE REVIEW | | IS REQUIRED IN THE NEXT REVIEW CYCLE FOR NEW SHEETS. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2017-05-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-05-25 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-17 |
Time |
08:14 |
Sent To |
|
|
Notes |
2017-05-25 14:44:50 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | A SHEETS OK | | E SHEETS OK PER V.PEREZ | | FP201A, FP201B, POSSIBLY OTHER SHEETS - SHEETS HAVE AN | | ERROR; THE SIGNATURE IS CORRUPTED (AARON LEE JOHNSON, | | PE), CHECK ALL | | P101B, P102A, POSSIBLY OTHER SHEETS - SHEETS HAVE AN | | ERROR; SIGNATURE IS CORRUPTED (AARON LEE JOHNSON, PE), | | CHECK ALL | | M203A, POSSIBLY OTHER SHEETS - SHEETS HAVE AN ERROR; | | SIGNATURE CORRUPTED | | T SHEETS (DENNIS O DAVIS, PE) OK | | | | | | | | | 2017-04-17 08:15:14 | ELEC SHEETS OK |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-06-15 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2017-06-15 |
Time |
12:05 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2017-06-15 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-05-16 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2017-05-16 |
Time |
14:05 |
Rev Time |
2.00 |
Received By |
eschneid |
Date |
2017-05-16 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|