Plan Review Details - Permit 17030200
Plan Review Stops For Permit 17030200
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-02 Cont ID  
Sent By shill Date 2017-06-02 Time 12:02 Rev Time 0.00
Received By shill Date 2017-06-02 Time 11:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-14 Cont ID  
Sent By shill Date 2017-03-15 Time 10:14 Rev Time 0.00
Received By shill Date 2017-03-14 Time 08:49 Sent To  
Notes
2017-03-14 10:14:46****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC 107, OUR PERMITTING PROCEDURES REQUIRE THAT EACH
 STRUCTURE REQUIRES A SEPARATE PERMIT (INCLUDING
 MONUMENT SIGNS), ALL SIGNS ATTACHED TO A BUILDING MAY
 BE ON ONE PERMIT.
  
 THE ILLUMINATED CHANNEL LETTER SIGN HAS NOT BEEN
 REVIEWED. SUBMIT THIS SIGN UNDER A SEPARATE
 APPLICATION. THIS PERMIT APPLICATION IS FOR NON
 ILLUMINATED SIGNS.
  
 DUE TO THE NUMBER OF SIGNS, THE METAL MONUMENT SIGNS
 (FOR EXAMPLE, TYPE 7) MAY ALL BE INCLUDED IN THIS
 PERMIT BUT SHOULD BE DESCRIBED IN THE PERMIT
 APPLICATION.
  
 A BLOCK OR CONCRETE MONUMENT IS SHOWN AS EXISTING,
 PROVIDE PERMIT NUMBER. IF A SEPARATE PERMIT HAS NOT
 BEEN APPLIED FOR, PLEASE DO SO AT THIS TIME. IF THERE
 ARE MULTIPLE MONUMENT SIGNS OF THIS TYPE, YOU MAY
 INCLUDE THEM ALL IN ONE PERMIT.
  
 2. SCOPE NOT CLEAR, FBC 107. THE APPLICATION LISTS THE
 TYPE OF SIGNS AN QUANTITY, BUT IT IS NOT CONSISTENT
 WITH THE PLANS SUBMITTED. REMOVE PAGES FOR SIGNS NOT TO
 BE INCLUDED IN THIS PERMIT. (FOR INSTANCE, TYPE 20,
 TYPE 7, OTHERS)
  
 3. PLANS (WITH THE EXCEPTION OF CHANNEL LETTER PLANS)
 ARE ALL CERTIFIED RATHER THAN SIGNED AND SEALED.
 CONFRIM WITH FBPE THAT THIS IS AN ACCEPTABLE METHOD TO
 COMPLY WITH FAC 61G15-23.003.
  
 4. ALL PLANS PREPARED BY THE ENGINEER INCLUDE AN IMAGE
 OF A SIGNATURE. FBPE HAS INFORMED ME THAT A SIGNATURE
 IS NOT PERMITTED ON DIGITAL PLANS. PAPER PLANS ARE TO
 BE SIGNED (AND AN IMAGE OF A SIGNATURE IS PROHIBITED),
 DIGITAL PLANS ARE NOT TO INCLUDE AN IMAGE OF A
 SIGNATURE AS SIGNATURES ARE TO BE ORIGINAL. SEE FS471,
 FAC61G15-23.
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2017-03-17 Cont ID  
Sent By shill Date 2017-03-17 Time 17:13 Rev Time 0.00
Received By shill Date 2017-03-17 Time 17:13 Sent To  
Notes
2017-03-17 17:15:21****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 SEE ALSO BUILDING COMMENTS AND THE PERMIT APPLICATION.
  
 THE APPLICATION IS FOR NON ILLUMINATED DIRECTIONAL
 SIGNS. THE CHANNEL LETTER SIGN INCLUDED IN THIS PACKAGE
 REQUIRES A SEPARATE PERMIT. COORDINATE WITH THE
 LIBRARIANS TO HAVE THE AFFECTED PAGES REMOVED AND
 SUBMIT UNDER A SEPARATE APPLICATION. ELECTRICAL WILL
 REVIEW AT THAT TIME.
  
 NO ELECTRICAL REVIEW HAS BEEN DONE AT THIS TIME.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-06-29 Cont ID  
Sent By lmarchan Date 2017-06-29 Time 09:57 Rev Time 0.00
Received By lmarchan Date 2017-05-30 Time 09:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-22 Cont ID  
Sent By cpuell Date 2017-03-22 Time 15:18 Rev Time 0.00
Received By cpuell Date 2017-03-08 Time 08:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2017-06-02 Cont ID  
Sent By shill Date 2017-06-02 Time 12:02 Rev Time 0.00
Received By shill Date 2017-06-02 Time 12:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2017-03-17 Cont ID  
Sent By shill Date 2017-03-17 Time 17:04 Rev Time 0.00
Received By shill Date 2017-03-17 Time 17:12 Sent To  
Notes
2017-03-17 17:12:22****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. DISREGARD SIGNATURE REVIEWS #1 AND #2; OUR SYSTEM
 WAS EXPERIENCING GLITCHES AT THE TIME THE REVIEWS WERE
 ENTERED AND ARE NOW LOCKED AND CANNOT BE UPDATED OR
 EDITED. THEREFORE A 3RD REVIEW WAS OPENED.
  
 2. THE MAJORITY OF THE PAGES ARE "CERTIFIED" RATHER
 THAN SIGNED AND SEALED. FOR EXAMPLES, SEE THE CHANNEL
 LETTER SIGN PLANS; THEY HAVE A TYPICAL COMPLIANT
 DIGITAL SIGNATURE AND SEAL. OTHER PAGES ARE "CERTIFIED"
 AND DO NOT INCLUDE A SIGNATURE. IT IS NOT CLEAR IF THIS
 METHOD COMPLIES WITH FS471. OBTAIN VERIFICATION FROM
 FBPE OR THE ISSUER OF THE DIGITAL SIGNATURE/SEAL THAT
 THIS IS ACCEPTABLE IN LIEU OF A DIGITAL SEAL WITH
 SIGNATURE.
  
 IF APPLICANT DOES NOT UNDERSTAND THIS COMMENT, PLEASE
 SEE ANY SHEET OTHER THAN THE CHANNEL LETTER PAGES. THE
 CHANNEL LETTER PAGES ARE SIGNED AND SEALED, THE OTHER
 PAGES ARE CERTIFIED.
  
 3. A CERTIFIED PAGE WAS SENT TO FBPE TO VERIFY THAT
 THIS WAS ACCEPTABLE IN LIEU OF A DIGITAL SIGNATURE AND
 SEAL. I HAVE NOT RECEIVED A RESPONSE REGARDING THIS
 ISSUE, BUT WAS INFORMED THAT AN IMAGE OF A SIGNATURE IS
 NOT ACCEPTABLE. EITHER REMOVE FROM ALL PAGES OR HAVE
 FBPE EMAIL A STATEMENT THAT THIS IS ACCEPTABLE TO THEM.
 SEE FS471, FAC61G15-23.002, 003.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2017-05-11 Cont ID  
Sent By shill Date 2017-03-13 Time 15:33 Rev Time 0.00
Received By shill Date 2017-03-15 Time 08:57 Sent To  
Notes
2017-05-11 15:33:29SEE REVIEW #3
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2017-05-11 Cont ID  
Sent By shill Date 2017-03-14 Time 15:32 Rev Time 0.00
Received By shill Date 2017-03-14 Time 10:16 Sent To  
Notes
2017-03-14 10:16:43SEE REVIEW #3
  

Review Stop Z ZONING
Rev No 2 Status P Date 2017-06-28 Cont ID  
Sent By ajones Date 2017-06-28 Time 11:28 Rev Time 0.00
Received By ajones Date 2017-06-28 Time 11:28 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-03-20 Cont ID  
Sent By ajones Date 2017-03-20 Time 17:16 Rev Time 0.00
Received By ajones Date 2017-03-20 Time 17:16 Sent To  
Notes
2017-03-20 17:19:563/20/21- FAILED, A SITE PLAN NEEDS TO BE PROVIDED
 SHOWING ME IF THE LIGHT POLE ADVERTISING BANNERS ARE
 WITHIN 300 FEET OF THE PERIMETER OF THE SITE. IF THEY
 ARE A MINOR AMENDMENT WILL BE REQUIRED.
  
 ANGELLA VANN
 561-822-1441
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved