Plan Review Stops For Permit 17021172
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-04-10 Cont ID  
Sent By rmcdouga Date 2017-04-10 Time 11:25 Rev Time 0.00
Received By rmcdouga Date 2017-04-10 Time 10:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-03-09 Cont ID  
Sent By rmcdouga Date 2017-03-09 Time 09:09 Rev Time 0.00
Received By rmcdouga Date 2017-03-09 Time 09:09 Sent To E
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-04-03 Cont ID  
Sent By vperez Date 2017-04-03 Time 12:02 Rev Time 0.00
Received By vperez Date 2017-04-03 Time 12:02 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-03-09 Cont ID  
Sent By vperez Date 2017-03-09 Time 11:36 Rev Time 0.00
Received By vperez Date 2017-03-09 Time 11:36 Sent To  
Notes
2017-03-09 11:38:51INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1. PLEASE PROVIDE A REVISED LOAD CALCULATION REFLECTING
 NEW 80AMP BREAKER FROM EXISTING PANEL. FBC 107.3.5
 2. ADDRESS ZONING COMMENTS FOR AN ELECTRICAL APPROVAL.
 3. PROVIDE A GENERAL NOTE TO PLAND TO COMPLY WITH FBC
 RES 4302.5 OVERHEAD CONDUCTOR CLEARANCES.
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-03-08 Cont ID  
Sent By tklarge Date 2017-03-08 Time 10:19 Rev Time 0.00
Received By tklarge Date 2017-03-08 Time 10:18 Sent To  
Notes
2017-03-08 10:19:25NO GAS POOL HEATER ON THIS POOL. ONLY HEAT PUMP.

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2017-03-06 Cont ID  
Sent By njwira Date 2017-03-06 Time 16:56 Rev Time 0.00
Received By njwira Date 2017-03-06 Time 16:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-04-10 Cont ID  
Sent By rmcdouga Date 2017-04-10 Time 11:25 Rev Time 0.00
Received By rmcdouga Date 2017-03-15 Time 13:08 Sent To  
Notes
2017-03-16 13:08:20RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-09 Cont ID  
Sent By vperez Date 2017-03-09 Time 11:43 Rev Time 0.00
Received By vperez Date 2017-03-09 Time 11:43 Sent To  
Notes
2017-02-28 10:59:53ROUTED TO HISTORIC VIA ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-04-06 Cont ID  
Sent By tklarge Date 2017-04-06 Time 08:28 Rev Time 0.00
Received By tklarge Date 2017-04-06 Time 08:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-03-08 Cont ID  
Sent By tklarge Date 2017-03-08 Time 10:18 Rev Time 0.00
Received By tklarge Date 2017-03-08 Time 10:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-03-30 Cont ID  
Sent By njwira Date 2017-03-30 Time 17:03 Rev Time 0.00
Received By njwira Date 2017-03-20 Time 15:02 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-03-06 Cont ID  
Sent By njwira Date 2017-03-06 Time 16:56 Rev Time 0.00
Received By njwira Date 2017-03-01 Time 15:35 Sent To  
Notes
2017-03-06 16:58:223/6/17- FAILED
  
 SF14-C2
  
 FAILED
 POOL EQUIPMENT PROJECTS MORE THAN 4FT. INTO A REQUIRED
 SETBACK
 TREE ALTERATION PERMIT REQUIRED TO MOVE TREES
  
 PASSED
 SIDE SETBACK IS 6.67FT. MEETING 5FT. REQUIREMENT
 REAR SETBACK IS 6.65FT. MEETING 5FT. REQUIREMENT
  
  
 PLEASE CONTACT
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING
 DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST.
 WEST PALM BEACH, FL 33402
 OFFICE HOURS: M-F 8AM - 5PM
 (561)822-1442
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved