Plan Review Details - Permit 17021061
Plan Review Stops For Permit 17021061 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-04-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-17 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-17 |
Time |
12:49 |
Sent To |
|
|
Notes |
2017-04-17 14:26:11 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- PROVIDE HURRICANE SHUTTERS COMPLETE INSTALLATION | | SCHEDULE. SEE CITY SAMPLE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-03-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-31 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-30 |
Time |
17:23 |
Sent To |
|
|
Notes |
2017-03-31 10:44:09 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) NEW ENTRY DOOR AS SHOWN ON PLANS. PROVIDE THE | | FLORIDA PRODUCT APPROVAL COVER PAGE FOR DRAWINGS | | SUBMITED. IF THERE IS NOT FLORIDA PRODUCT APPROVAL, | | THEN DOOR MANUFACTURER MAY SUBMITT COMPLETE ORIGINAL | | ENGINEERING PACKAGE FOR LOCAL PRODUCT APPROVAL BY | | BUILDING OFFICIAL. | | | | B) NEW SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | | C) HURRICANE SHUTTERS IF WINDOWS DON'T HAVE IMPACT | | GLAZING. AND PROVIDE COMPLETE INSTALLATION SCHEDULE. | | SEE CITY SAMPLE. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 3- PRODUCT APPROVALS INFORMATION SHOWN ON SHEET S-1 AND | | S-3 DON'T MATCH PRODUCT APPROVALS SUBMITTED. ENGINEER | | OF RECORD TO REVISE AS REQUIRED TO MATCH.. SEC. 107.2.1 | | CITY AMENDMENTS. | | | | 4- ENGINEER OF RECORD TO CLARIFY SCOPE OF WORK NOTE # 2 | | ON SHEET D-1. THERE IS NOT BATHROOM #4. REVISE AS | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-03-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-03-13 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-03-13 |
Time |
11:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-04-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-17 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-10 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-03-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-31 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-24 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2017-04-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-04-17 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-04-17 |
Time |
15:00 |
Sent To |
|
|
Notes |
2017-04-17 15:02:08 | PER CONVERSATION WITH VINCENT LAWSON (CONTRACTOR) | | CORRECT A/C PLAN AND EQUIPMENT SIZING CALCULATIONS TO | | BE SUBMITTED UNDER A SEPARATE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-03-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-31 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-31 |
Time |
07:54 |
Sent To |
|
|
Notes |
2017-03-31 11:41:39 | RESIDENTIAL (R3) ALTERATION, MECHANICAL REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS (2 | | COPIES) ALONG WITH THE MANUFACTURER AND MODEL NUMBER AS | | REQUIRED BY SEC. R403.6 FBC-ENERGY CONSERVATION, 5TH | | EDITION (2014). | | | | 2- ENGINEER OF RECORD TO SPECIFY ON THE A/C PLAN THE | | EQUIPMENT MANUFACTURER AND MODEL NUMBER SPECIFIED ON | | THE EQUIPMENT SIZING CALCULATIONS. SEC. 107.3.5.3(10) | | CITY AMENDMENTS. | | | | 3- ENGINEER OF RECORD TO SPECIFY THE CFM'S ON THE A/C | | PLAN. SEC. 107.3.5.3(10) CITY AMENDMENTS. | | | | 4- ENGINEER OF RECORD TO SHOW ON THE A/C PLAN | | COMPLIANCE WITH THE BALANCED RETURN AIR AS REQUIRED BY | | SEC. M1602.4 FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-04-17 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-17 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-04-17 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-03-14 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-14 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-14 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
|