Plan Review Stops For Permit 17020950 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-04 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-03 |
Time |
15:37 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-24 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-24 |
Time |
13:19 |
Sent To |
|
|
Notes |
2017-10-24 16:59:09 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROPERTY IS LOCATED IN A FLOOD ZONE. ELEVATION | | CERTIFICATE REQUIRED. | | 2. THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | AREA (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS | | SITE IS A5 WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE) | | REQUIRES AN ADDITIONAL 12 INCHES OF FREEBOARD REQUIRING | | THE DESIGN FLOOD ELEVATION (DFE) TO BE 8. 0 FEET. | | PLEASE NOTE THIS INFORMATION ON YOUR PLANS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-01-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-01-22 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-01-22 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-12-11 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-12-11 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-12-11 |
Time |
08:47 |
Sent To |
|
|
Notes |
2017-12-11 09:14:36 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | 2ND ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS | | BELOW. | | | | COMMENTS CORRECTED HAVE BEEN NOTED, REMAINING COMMENTS | | ARE NOT ADDRESSED SATISFACTORILY. SEE ADDITIONAL | | COMMENTARY IN PARENTHESES. | | | | 1. PROVIDE PANEL SCHEDULE FOR EACH PANEL, INDICATING | | THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, AND AFCI | | OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY WITH | | CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE3706.2, | | RE3902 (THERE IS NO PANEL SCHEDULE FOR THE FUTURE | | PANEL. ANY FUTURE PANEL WOULD LIKELY OVERLOAD THE | | SERVICE, SINCE THE PROVIDED LOAD CALCULATION IS AT 182 | | AMPS ON A 200 AMP SERVICE. PROVIDE PANEL SCHEDULE WITH | | LOAD, OR REMOVE FROM PLAN. NEC 220; FBC 107.2.1) | | 2. CORRECTED. | | 3. RISER DIAGRAM SHOWS TWO 100 AMP SUB-PANELS, BUT ONLY | | ONE IS SHOWN ON POWER PLAN. PROVIDE LOCATION OF ALL | | SUB-PANELS. FBC 107.2.1 (PLAN NOW SHOWS AN ATS ADJACENT | | TO METER AND A 200 AMP PANEL INSIDE THE GARAGE, BUT | | THIS PANEL IS NOT LABELED. IS THE ATS ALSO A PANEL, OR | | JUST AN ATS WITH MAIN BREAKER AS SHOWN? WHERE IS PANEL | | A AND PANEL B? RISER SHOWS ITEMS BEING FED FROM PANEL B | | THAT ARE LOCATED IN THE PANEL SCHEDULE FOR PANEL A. | | PLAN IS REQUIRED TO BE ACCURATE. PROVIDE CORRECTIONS. | | FBC 107.2.1) | | 4. CORRECTED. | | 5. CORRECTED. | | 6.CORRECTED. | | 7.CORRECTED. | | 8. CORRECTED. | | 9. CORRECTED. | | 10. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED | | TO BEAR THE NAME AND BE SIGNED AND SEALED BY THE PERSON | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FBC | | 107.2.1, FS 471, 481 (A LETTER STATING THAT SOMEONE | | DESIGNED THE PLAN IS NOT SUFFICIENT. THE PLAN MUST BE | | SIGNED BY THE PERSON RESPONSIBLE FOR THE DESIGN, WITH | | THAT PERSON'S INFORMATION SHOWN ON PLAN.) | | 11. NEW COMMENT: RISER SHOWS THE FEED TO PANEL B AS TWO | | 2/0 AND ONE 1/0 COPPER WIRE. THIS CONDUIT REQUIRES AN | | EQUIPMENT GROUNDING CONDUCTOR. PROVIDE CORRECTIONS. NEC | | 310.15, 250.120, 122 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-05 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-10-05 |
Time |
13:02 |
Sent To |
|
|
Notes |
2017-10-05 13:02:33 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE PANEL SCHEDULE FOR EACH PANEL, INDICATING | | THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, AND AFCI | | OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY WITH | | CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE3706.2, | | RE3902 | | 2. RISER DIAGRAM SHOWS TWO 100 AMP SUB-PANELS FED WITH | | #8 WIRE. #8 WIRE IS NOT RATED FOR 100 AMPS. PROVIDE | | CORRECTION. NEC 310.15(B)(16); FBC RE TABLE E3705.1 | | 3. RISER DIAGRAM SHOWS TWO 100 AMP SUB-PANELS, BUT ONLY | | ONE IS SHOWN ON POWER PLAN. PROVIDE LOCATION OF ALL | | SUB-PANELS. FBC 107.2.1 | | 4. GARAGE DOOR OPENER OUTLET REQUIRES GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8; FBC RE3902.2 | | 5. PLAN SHOWS 2 DISHWASHERS, BUT I ONLY SEE ONE | | INCLUDED IN THE LOAD CALCULATION. PROVIDE ACCURATE LOAD | | CALCULATION. NEC 220; FBC RE3902.3 | | 6. KITCHEN ISLAND RECEPTACLES REQUIRE GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8; FBC RE 3902.6 | | 7. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC R315.1 | | 8. LIGHTING IN CLOSETS IS SHOWN AS STANDARD RECESS | | LIGHTS. PER CODE: "LIGHTING WITH OPEN OR PARTIALLY | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS". PROVIDE | | CORRECTION. ALSO, CORRECT NOTE THAT STATES LIGHTING IN | | CLOSETS TO COMPLY WITH SECTION 4108, THIS SECTION DOES | | NOT EXIST IN THE NEC . NEC 410.16; FBC RE4003.12; FBC | | 107.2.1 | | 9. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | FBC CE R404.1 | | 10. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED | | TO BEAR THE NAME AND BE SIGNED AND SEALED BY THE PERSON | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FBC | | 107.2.1, FS 471, 481 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2018-01-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-01-05 |
Time |
04:32 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-01-05 |
Time |
04:32 |
Sent To |
|
|
Notes |
2018-01-05 04:32:34 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A GAS PERMIT IS REQUIRED FOR A CONTRACTOR TO | | PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS THAT | | REFLECT THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB | | AMEND. TO FBC SEC.107.2.1. | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | FBC-R, SEC. G2404.3. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2017-10-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-11 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-10-11 |
Time |
07:16 |
Sent To |
|
|
Notes |
2017-10-11 07:17:34 | GAS PLAN REVIEW | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | 107.2.1. | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | FBC-R, SEC. G2404.3. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-01-22 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-01-18 |
Time |
13:38 |
Sent To |
|
|
Notes |
2018-01-19 13:38:15 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-01-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-01-05 |
Time |
04:32 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-12-07 |
Time |
10:18 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-11-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-11-02 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-09-29 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-04 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-03 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-24 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-24 |
Time |
13:20 |
Sent To |
|
|
Notes |
2017-10-24 13:21:14 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-12-20 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-12-20 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-12-19 |
Time |
10:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-11-02 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-11-02 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-11-02 |
Time |
13:04 |
Sent To |
|
|
Notes |
2017-11-02 14:24:40 | PLAN DENIED | | PROVIDE DUCT SIZE ON A/C # 2 TWO SUPPLY LINES COMING | | OFF SUPPLY PLENUM. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
P |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-04 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-03 |
Time |
15:37 |
Sent To |
|
|
Notes |
2018-01-04 09:56:58 | PROPERLY COMPLETED EC REQUIRED PRIOR TO CO |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2017-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-24 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-24 |
Time |
16:51 |
Sent To |
|
|
Notes |
2017-10-24 17:03:36 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS | | A5 WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. THE CITY | | OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES AN | | ADDITIONAL 12 INCHES OF FREEBOARD REQUIRING THE DESIGN | | FLOOD ELEVATION (DFE) TO BE 8. 0 FEET. PLEASE NOTE THIS | | INFORMATION ON YOUR PLANS. | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | REQUIRED AT TIME OF PERMIT APPLICATION. | | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS | | SITE ARE REQUIRED TO BE AT OR ABOVE 8.0 FEET NGVD. | | | | AN UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | RECOMMENDED. | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | | 1612.1 GENERAL. | | WITHIN FLOOD HAZARD AREAS AS ESTABLISHED IN SECTION | | 1612.3, ALL NEW CONSTRUCTION OF BUILDINGS, STRUCTURES | | AND PORTIONS OF BUILDINGS AND STRUCTURES, INCLUDING | | SUBSTANTIAL IMPROVEMENT AND RESTORATION OF SUBSTANTIAL | | DAMAGE TO BUILDINGS AND STRUCTURES, SHALL BE DESIGNED | | AND CONSTRUCTED TO RESIST THE EFFECTS OF FLOOD HAZARDS | | AND FLOOD LOADS. FOR BUILDINGS THAT ARE LOCATED IN MORE | | THAN ONE FLOOD HAZARD AREA, THE PROVISIONS ASSOCIATED | | WITH THE MOST RESTRICTIVE FLOOD HAZARD AREA SHALL | | APPLY. | | | | 1612.4 DESIGN AND CONSTRUCTION. | | THE DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES | | LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH | | HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF | | ASCE 7 AND WITH ASCE 24. | | | | FBC 107.3.5.3 RESIDENTIAL (ONE AND TWO-FAMILY) & | | R322.2.1 ELEVATION REQUIREMENTS. BUILDINGS AND | | STRUCTURES IN FLOOD HAZARD AREAS NOT DESIGNATED AS | | COASTAL A ZONES SHALL HAVE THE LOWEST FLOORS ELEVATED | | TO OR ABOVE THE DESIGN FLOOD ELEVATION. PROVIDE FLOOD | | DESIGN INFORMATION ON THE PROPOSED SURVEY AND PROVIDE | | FLOOD ELEVATION CERTIFICATE. | | | | G1001.4 ENCLOSURES BELOW DESIGN FLOOD ELEVATION. | | FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD ELEVATION | | SHALL BE AT OR ABOVE GRADE ON ALL SIDES AND CONFORM TO | | THE FOLLOWING: | | | | 1. IN FLOOD HAZARD AREAS NOT SUBJECT TO HIGH-VELOCITY | | WAVE ACTION, ENCLOSED AREAS SHALL HAVE FLOOD OPENINGS | | TO ALLOW FOR THE AUTOMATIC INFLOW AND OUTFLOW OF | | FLOODWATERS. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-01-22 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-01-22 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-01-22 |
Time |
08:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-01-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-01-05 |
Time |
04:29 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-12-29 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-12-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-11 |
Time |
07:11 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-10-11 |
Time |
07:01 |
Sent To |
|
|
Notes |
2017-10-11 07:16:01 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. THE LAUNDRY SINK AND WASHING MACHINE SHALL CONNECT | | TO THE BUILDING DRAIN DOWN STREAM OF THE BATHROOM | | GROUP. PER FBC RES P3108.1 | | | | 2. A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH | | WASTE OR SOIL STACK. PER FBC RES P3005.2.6 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2017-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-24 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-24 |
Time |
13:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-12-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2017-12-21 |
Time |
15:19 |
Sent To |
|
|
Notes |
2017-12-22 12:19:28 | LANDSCAPE PERMIT REQUIRED | | | | PAUL GREILICH, SENIOR PLANNER | | 561-822-1443 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
PG |
Date |
2017-11-01 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2017-11-01 |
Time |
14:27 |
Sent To |
|
|
Notes |
2017-11-01 14:34:02 | 1.) LANDSCAPE PERMIT REQUIRED | | 2.) LABEL OVERAL HEIGHT OF PROPOSED RESIDENCE | | | | PAUL GREILICH, SENIOR PLANNER | | 561-822-1443 | | [email protected] |
|
|