Plan Review Details - Permit 17020796
Plan Review Stops For Permit 17020796 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-11-13 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-11-13 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2018-05-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-12 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-12 |
Time |
10:33 |
Sent To |
|
|
Notes |
2018-05-12 10:34:50 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | PLEASE ADVISE; DO YOU HAVE PARCEL ID NUMBERS AND | | ADDRESSES ASSIGNED FROM PROPERTY APPRAISER? | | | | WHEN WILL THE REPLAT BE FINALIZED? IF FILED, PROVIDE | | BOOK/PAGE. | | | | PLEASE PROVIDE THIS INFORMATION VIA EMAIL, SUBJECT LINE | | TO REFERENCE THIS PERMIT NUMBER 17020796. | | | | |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2017-04-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-24 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-24 |
Time |
17:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
F |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
scwelter |
Date |
2022-08-15 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
scwelter |
Date |
2022-08-15 |
Time |
16:23 |
Sent To |
|
|
Notes |
2022-08-15 16:23:37 | SUBJECT TO PUBLIC ART REQUIREMENT. CONTACT | | [email protected] FOR AN ART ASSESSMENT APPLICATION. | | MUST CONTRIBUTE TO THE PUBLIC ART ACCOUNT. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-10-16 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-10-16 |
Time |
08:06 |
Sent To |
|
|
Notes |
2018-10-16 08:05:17 | PROVISO: DERFERED SUBMITTALS | | 1. ROOFING (SUBMIT WITH SUB-PERMIT) | | 2. GUARDS AND HANDRAILS | | 3. STEEL PAN STAIRS | | 4. TRASH CHUTE | | 5. FENESTRATION | | 6. FLOORING SUBMITTAL WITH REPORTS FOR ICC, STC AND | | FLAME SPREAD/SMOKE DEVELOPED INDEX. | | 7. ART IN PUBLIC PLACES (AIPP) | | 8. SHORING/RE-SHORING | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-09-07 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-09-07 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-09-05 |
Time |
11:34 |
Sent To |
|
|
Notes |
2018-09-07 14:27:42 | ****CORRECTIONS**** | | W.P.B. PERMIT: 17020796 | | 3RD REVIEW: SEPTEMBER 6, 2018 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER I | | [email protected] | | 561-805-6718 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. OK | | | | 2. COMMENT FROM FIRST REVIEW: A1.2.01 EXIT DISCHARGE | | NOT CLEAR; REVISE PLAN TO SHOW COMPLIANCE WITH FBC B | | 1027. | | | | ON THE ELECTRICAL PAGES, I WAS NOT ABLE TO LOCATE VOICE | | EVAC. SHEET E2.1.01 SHOWS A FIRE ALARM CONTROL PANEL, | | DETAILS ON E3.1.02, BUT I WAS UNABLE TO LOCATE THE | | LABEL "EVAC" ON THE FLOOR PLANS (PER ELECTRICAL LEGEND) | | AND E3.1.02 WAS NOT CLEAR. PLEASE DIRECT WHERE THIS | | INFORMATION CAN BE FOUND OR CLARIFY INTENT. NOTE THAT | | FBC B 1005.3.1 REQUIRES .3" PER OCCUPANT, BUT .2" WAS | | USED PER EXCEPTION. | | | | 2- 3RD REVIEW | | MOST OF THIS IS WAS ADDRESSED IN COMMENT RESPONSE, BUT | | NOT THE VOICE EVAC PORTION. THE FACP ON SHEET E-3.1.02 | | DOESN'T SHOW AS A VOICE EVAC SYSTEM. | | | | (SEE NEW COMMENTS FROM LIFE SAFETY SHEETS PROVIDED AT | | BOTTOM STARTING COMMENT #35) | | | | 3-6. OK | | | | 7-11. OK | | | | 12. 2ND REVIEW, NOT ADDRESSED. ENGINEER OF RECORD IS TO | | REVIEW THE SOILS, EITHER WITH A SHOP DRAWING REVIEW | | STAMP OR BY INCORPORATING A REFERENCE INTO THE PLAN. | | THE SOILS REPORT WAS PROVIDED FOR THE FOUNDATION PERMIT | | APPLICATION (17010911). AFTER THE FOUNDATION PERMIT IS | | ISSUED, THE SOILS WILL BE PUBLIC RECORD AND IS NOT | | NEEDED FOR THIS PERMIT. IF YOU RESUBMIT PRIOR TO | | ISSUANCE OF FOUNDATION PERMIT, PLEASE INCLUDE IN YOUR | | RESUBMITTAL. | | | | 12- 3RD REVIEW THE NOTES ADDED WILL REFER TO SOILS | | REPORT FOR BEARING CAPACITY, BUT STRUCTURAL SHEETS | | S-2.00, S-2.00A AND S-2.00B SHOW THE TOP OF FOOTERS AT | | 12" BELOW GRADE. THE GEO TECHNICAL REPORT STATES THAT | | TOP OF FOOTERS SHOULD BE PLACED 18" BELOW GRADE. PLEASE | | REVIEW AND REVISE AS APPLICABLE. | | | | 13-37. OK (26-28 MOVED TO PROVISO) | | | | 38. (MOVED TO PROVISO) | | | | 39-40. OK | | | | 41. (MOVED TO PROVISO) | | | | 42. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | THIS IS COMPLETE. | | | | B. SEPARATE PERMITS REQUIRED. SUB PERMITS FOR | | MECHANICAL, ELECTRICAL, PLUMBING ARE REQUIRED. SEPARATE | | PERMITS (APPLICATION, FEES, PLANS, REVIEWS) REQUIRED | | FOR ALL OTHER ITEMS SUCH AS PARKING, SIGNAGE, ETC. | | | | C. COMPLIANCE WITH FBC B 1006, MEANS OF EGRESS | | ILLUMINATION, INCLUDING EXIT DISCHARGE, REQUIRED. | | | | D. VOICE EVAC REQUIRED (NOTE 35, SHEET E3.1.02). | | | | E. ADVISORY ONLY; THE LANDSCAPE PLANS APPEAR TO | | CONFLICT WITH THE EXIT DISCHARGE. LANDSCAPE PERMIT | | REQUIRES A SEPARATE SUBMITTAL; PERMIT APPLICATION, | | FEES, AND PLANS AND ARE NOT REVIEWED BY BUILDING. | | | | F. PRODUCT APPROVALS FOR ALL COMPONENTS AND CLADDING | | ARE TO BE SUBMITTED, REVIEWED BY DESIGNER OF RECORD, | | REVIEWED AND ISSUED PRIOR TO INSTALLATION. | | | | G. SHORING/RESHORE ENGINEERING ARE REQUIRED TO BE | | SUBMITTED, REVIEWED, AND ISSUED PRIOR TO INSTALLATION. | | FAILURE TO DO SO WILL RESULT IN A STOP WORK ORDER. | | | | H. AN ENGINEERED CONSTRUCTION GUARD RAIL DETAIL IS | | REQUIRED PRIOR TO INSTALLATION. THIS MAY BE SUBMITTED | | AS A SUBMITTAL ALONG WITH THE SHORING/RESHORE, BUT MAY | | BE PROVIDED IN THE FIELD TO KEN CONRAD, SUBJECT TO HIS | | APPROVAL. | | | | I. RECORDED REPLAT REQUIRED PRIOR TO C.O.; PROVIDE | | BOOK/PAGE VIA EMAIL. | | | | J. BUILT IN BENCHES TO COMPLY WITH FBC A 903. | | | | K. DRESSING, FITTING AND LOCKER ROOMS TO COMPLY WITH | | FBC A 222, REVISE PLAN TO SHOW COMPLIANCE. | | | | L. SPA RECEPTION/ RETAIL DESK, ANY OTHER CHECK OUT | | AREAS, SEE FBC A 904 NOTE ON PLAN AND PROVIDE A DETAIL | | 2ND REVIEW: RESPONSE TO 26, 27, 28 REFERS TO D SHEETS; | | THESE PAGES ARE NOT SIGNED AND SEALED AND IT IS NOT | | CLEAR WHO IS TAKING RESPONSIBILITY FOR THE PAGES. | | PLEASE REMOVE THE SHEETS AS IT APPEARS MOST OF THE | | INFORMATION IS NOT REQUIRED. ITEMS 26, 27, AND 28 CAN | | BE A PROVISO ITEM. | | | | M. FBC B 603.1, A4.4.02 DETAIL 12 SHOWS POLYSTYRENE | | OUTRIGGER AT METAL ROOFS AND POSSIBLY OTHER LOCATIONS, | | OTHER DETAILS. PLEASE PROVIDE MORE INFORMATION VIA | | EMAIL REGARDING HEIGHT OF LOCATIONS PROPOSED (OVER | | 30'?), OVER EXITS. A4.4.03 SHOWS EXTERIOR FOAM; PROVIDE | | INFORMATION VIA EMAIL. ARE THESE PRODUCTS | | NONCOMBUSTIBLE? | | | | N. ADVISORY ONLY; SHEET D0.0.00 SHOWS A PLATFORM BED. | | IT IS NOT CLEAR IF THIS BED COMPLIES WITH FBC A | | 806.4(II), OPEN-FRAME TYPE BEDS REQUIRED. THIS WILL BE | | A PROVISO ITEM. | | | | ADDITIONAL COMMENTS: | | | | 43. [FBC 1011.1]SHEET A-1.2.01 EXIT SIGNS. EXIT SIGNS | | ARE ONLY LOCATED AT THE EGRESS DOORS AND NO | | INTERMEDIATE SIGNS ARE PROVIDED WHEN THE EGRESS DOOR | | ISN'T VISABLE. FLOORS 2-4 DO A GOOD JOB OF THIS, BUT | | FIRST FLOOR NEEDS REVIEW OF EXIT SIGN PLACEMENT. | | | | 44. [FBC 1011.2]FLOOR-LEVEL EXIT SIGNS IN GROUP R-1. | | WHERE EXIT SIGNS ARE REQUIRED IN GROUP R-1 OCCUPANCIES | | BY SECTION 1011.1, ADDITIONAL LOW-LEVEL EXIT SIGNS | | SHALL BE PROVIDED IN ALL AREAS SERVING GUESTROOMS IN | | GROUP R-1 OCCUPANCIES AND SHALL COMPLY WITH SECTION | | 1011.5. | | | | 45. [FBC 701]GENERAL COMMENT-CHECK THAT LIFE SAFETY | | SHEET FOR 1ST FLOOR SHOWS DESIGNATED LINES TO CORESPOND | | WITH FIRE RATED WALLS AND THAT FLOORS PLAN WALL TYPES | | MATCH THE REQ?D FIRE RATINGS. MAINLY ON SHEET A-1.2.01 | | THE CORRIDORS DON?T SHOW THE 1 HOUR RATED DASHED LINES | | (SEE BELOW FOR EXAMPLES ON THE FLOOR PLANS) | | | | 46. [FBC 701]SHEET A-1.4.01B WALLS IN WOMENS LOUNGE AND | | SPA THAT DEFINE COORIDOR ARE LABLED TYPE C4 WHICH IS | | NON-RATED, BUT LIFE SAFETY STATES ALL CORRIDORS ARE TO | | BE 1 HR WHICH WOULD BE TYPE C1 ACCORDING TO SHEET | | A-6.6.02. | | | | 47. [FBC 701]SHEET A-1.4.01A MECH RM 116 SHOWS C1 ON | | CORRIDOR WALL, BUT THE REST OF ROOM IS 2 HR. | | SAME FOR RM 1112C. ALSO, MECH ROOM 1103A BACK WALL IS | | NOT LABELED WITH WALL TYPE. | | | | 48. [FBC 701]SHEET A-1.4.01A WHY ARE FIRE RATED WALLS | | IN RM 1107 & 1108 CALLED OUT FOR THE BATHROOM | | PARTITIONS? ARE THEY SUPPOSED TO BE C4 FOR SOUND ONLY? | | ALSO, FOR RESTROOMS 1149 & 1150 NO WALL TYPES ARE | | SHOWN. | | IN GENERAL PLEASE LOOK AT RESTROOMS AND PROVIDE | | INTENDED WALL TYPES. | | | | 49. WHAT IS THE RATING, ASSEMBLY AND GLASS TYPE FOR | | WALLS/WINDOWS ATDINING BOOTHS THAT LOOK INTO CORRIDOR | | 1122? | | | | 50. [NO CODE REF]CHECK SHEET A-1.3.01 1ST FLOOR PLAN. | | THE PERIMETER HAS A LIGHTER OFF-SET LAYER THAT SHOWS | | ITEMS ON A LAYER THAT I THINK SHOULD BE TURNED OFF. | | | | 51. [FBC ACCESSIBILITY 233.3.1]MINIMUM NUMBER: NEW | | CONSTRUCTION. | | IN FACILITIES WITH RESIDENTIAL DWELLING UNITS, AT LEAST | | 5 PERCENT, BUT NO FEWER THAN ONE UNIT, OF THE TOTAL | | NUMBER OF RESIDENTIAL DWELLING UNITS SHALL PROVIDE | | MOBILITY FEATURES COMPLYING WITH 809.2 THROUGH 809.4 | | AND SHALL BE ON AN ACCESSIBLE ROUTE AS REQUIRED BY 206. | | I SEE 5 ROOMS PROVIDED, BUT 5% OF 150 ROOMS WOULD BE 8 | | ROOMS NEEDED TO COMPLY WITH REQUIRED AMOUNT. | | | | 52. [FBC ACCESSIBILITY 233.3.1.2]RESIDENTIAL DWELLING | | UNITS WITH COMMUNICATION FEATURES. | | IN FACILITIES WITH RESIDENTIAL DWELLING UNITS, AT LEAST | | 2 PERCENT, BUT NO FEWER THAN ONE UNIT, OF THE TOTAL | | NUMBER OF RESIDENTIAL DWELLING UNITS SHALL PROVIDE | | COMMUNICATION FEATURES COMPLYING WITH 809.5. | | I SEE 11 ROOMS PROVIDED WHICH EXCEEDS THE RE'D 2% (3 | | ROOMS). THIS EXCEEDS CODE AND I ONLY MENTION BECAUSE I | | WONDER IF SOME OF THESE WERE INTENED TO PROVIDE | | MOBILITY FEATURES INSTEAD OF COMMUNICATION FEATURES. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-05-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-12 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-30 |
Time |
18:54 |
Sent To |
|
|
Notes |
2018-05-07 06:24:09 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | BANYAN CAY FOUR STORY HOTEL | | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | TRUSSES, TYPE IIA | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | AR7073 | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | UNTERWEGER, PE63860 | | MEP - TLC ENGINEERING | | MECHANICAL - JORGE E. REYES, PE54904 | | ELECTRICAL - RALPH BAEZA, PE42641 | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | 1. OK | | | | 2. COMMENT FROM FIRST REVIEW: A1.2.01 EXIT DISCHARGE | | NOT CLEAR; REVISE PLAN TO SHOW COMPLIANCE WITH FBC B | | 1027. | | | | 2ND REVIEW, RESPONSE LETTER STATES THAT FBC B 1027 | | REFERENCES "EXTERIOR EXIT STARIWAYS AND RAMPS" AND | | GIVES SOME EXPLANATION ABOUT ALL STAIRS BEING INTERIOR | | STAIRS. | | | | THE FBC 2014 BUILDING, SECTION 1027, IS TITLED "EXIT | | DISCHARGE". SECTION 1022 IS INTERIOR STAIRS AND RAMPS. | | SEE PREVIOUS COMMENT; REFERENCE WAS TO FBC B 1027, NOT | | FBC B 1022, AND SPECIFICALLY REFERENCES "EXIT | | DISCHARGE". IT IS NOT CLEAR WHY RESPONSE LETTER | | EXPLAINS SOMETHING UNRELATED. | | | | SEE FBC 1027.5, EXIT DISCHARGE SHALL PROVIDE A DIRECT | | AND UNOBSTRUCTED ACCESS TO A PUBLIC WAY, SEE ALSO | | EXCEPTIONS. ALSO SEE COMMENT #3. SHEET A1.2.00 APPEARS | | TO SHOW COMPLIANCE EXCEPT AS NOTED IN OTHER COMMENTS, | | BUT INFORMATION REGARDING ACCESSIBILITY AND SLOPES NOT | | PROVIDED. | | | | COMPLIANCE WITH REQUIREMENTS FOR EXIT DISCHARGE | | ILLUMINATION NOT CLEAR; THIS PERMIT WILL BE ISSUED WITH | | PROVISO, COMPLIANCE WITH FBC B 1006 REQUIRED. | | | | FIRST FLOOR LIFE SAFETY PLAN A1.2.01 IS NOT CLEAR ON | | NUMBER OF OCCUPANTS IN EACH ROOM AS A SUMMARY WAS | | PROVIDED. IT APPEARS THAT EXIT CAPACITY IS ADEQUATE FOR | | EACH AREA, BUT COMPLIANCE WITH REQUIREMENT FOR EXIT | | DISCHARGE IS NOT CLEAR. | | | | FOR INSTANCE: THE PATH AT THE LEFT OF THE SITE LIFE | | SAFETY PLAN INDICATES "146 OCCUPANTS". FIRST FLOOR | | SHOWS 146 OCCUPANTS EXITING FROM THE STAIR AND EXIT | | CORRIDOR. BUT NO OCCUPANT LOAD WAS PROVIDED FOR MEETING | | ROOM #1, BALLROOM #1, ETC. WHICH ALSO TRAVEL ALONG THE | | SAME PATH IN THE EXIT DISCHARGE. A SUMMARY FOR EACH | | OCCUPANCY WAS PROVIDED, BUT AS THE OCCUPANCIES ARE IN | | DIFFERENT AREAS OF THE BUILDING, THE NUMBER USING THE | | GRAPHICALLY DEPICTED EXIT DISCHARGE IS NOT CLEAR. | | | | THE CIVIL PAGES INCLUDE ELEMENTS IN THE EXIT DISCHARGE | | WHICH ARE NOT SHOWN ON THE LIFE SAFETY SHEETS (APPEARS | | TO BE FENCES, GATES). PLEASE CORRELATE. FOR INSTANCE, | | CIVIL PAGE 2 OF 9 MASTER PLAN) WHICH SHOWS GATES IN THE | | MEANS OF EGRESS, AND THE SITE LIFE SAFETY PLAN A1.2.00. | | PLEASE CORRELATE AND NOTE THAT ALL GATES WILL INCLUDE | | PANIC HARDWARE (PER FBC B 1008.2. NO INFORMATION WAS | | PROVIDED REGARDING THE WIDTH OF THESE ELEMENTS. | | | | THE ELECTRICAL SITE PLAN E1.1.01 APPEARS TO CONFLICT | | WITH THE EXIT DISCHARGE (GENERATOR, OTHER ITEMS); | | PLEASE CORRELATE. IF THEY DO NOT CONLICT PROVIDE ENOUGH | | DIMENSIONS ON THE PLAN TO SHOW THAT THE GENERATOR IS | | NOT INTERFEREING WITH THE HATCHED EXIT DISCHARGE SHOWN | | ON OTHER SHEETS. | | | | ADVISORY ONLY; THE LANDSCAPE PLANS APPEAR TO CONFLICT | | WITH THE EXIT DISCHARGE. LANDSCAPE PERMIT REQUIRES A | | SEPARATE SUBMITTAL; PERMIT APPLICATION, FEES, AND PLANS | | AND ARE NOT REVIEWED BY BUILDING. | | | | ON THE ELECTRICAL PAGES, I WAS NOT ABLE TO LOCATE VOICE | | EVAC. SHEET E2.1.01 SHOWS A FIRE ALARM CONTROL PANEL, | | DETAILS ON E3.1.02, BUT I WAS UNABLE TO LOCATE THE | | LABEL "EVAC" ON THE FLOOR PLANS (PER ELECTRICAL LEGEND) | | AND E3.1.02 WAS NOT CLEAR. PLEASE DIRECT WHERE THIS | | INFORMATION CAN BE FOUND OR CLARIFY INTENT. NOTE THAT | | FBC B 1005.3.1 REQUIRES .3" PER OCCUPANT, BUT .2" WAS | | USED PER EXCEPTION. | | | | 3. COMMENT FROM FIRST REVIEW: ACCESSIBLE MEANS OF | | EGRESS SELECTED NOT CLEAR; SEE FBC 1007, FBC A 207.1. | | REVISE PLAN TO STATE WHICH METHOD IS SELECTED AND | | CONFIRM COMPLIANCE WITH METHOD SELECTED; REVISE PLAN IF | | NECESSARY TO SHOW COMPLIANCE. | | | | 2ND REVIEW, RESPONSE LETTER GIVES INFORMATION REGARDING | | STAIRS. THIS DOES NOT ADDRESS THE COMMENT. | | | | FBC B 1007 REFERS TO FBC A 207.1. | | FBC A 207.1 MEANS OF EGRESS SHALL COMPLY WITH SECTION | | 1003.2.13 OF THE INTERNATIONAL BUILDING CODE 2000 AND | | 2001 SUPPLEMENT OR SECTION 1007 OF THE INTERNATIONAL | | BUILDING CODE 2003 EDITION. COMPLIANCE WITH ONE OF | | THESE TWO METHODS OF COMPLIANCE IS NOT CLEAR; | | PARTICULARLY THE EXIT DISCHARGE (SEE ALSO IBC 2003 | | 1007.2). | | | | THIS ITEM HAS NOT BEEN REVIEWED. | | | | AS THE FINISHED FLOOR AFFECTS THE ACCESSIBLE ROUTE, | | EXIT DISCHARGE, AND ACCESSIBLE EXIT DISCHARGE, | | COMPLIANCE SHOULD BE DEMONSTRATED PRIOR TO ISSUANCE OF | | A FOUNDATION PERMIT - RESOLUTION TO COMMENTS #2 AND #3 | | NEED TO BE RESOLVED PRIOR TO FOUNDATION PERMIT | | ISSUANCE. | | | | APPLICANT MAY SEND AN EMAIL EXPLAINING COMPLIANCE AND | | HOW THIS WILL BE ADDRESSED UPON RESUBMITTAL TO GET THIS | | ISSUE RESOLVED PRIOR TO REVIEW OF FOUNDATION PERMIT. | | | | 4-6. OK | | | | 7. COMMENT FROM FIRST REVIEW: A1.4.01B, FITNESS ROOM TO | | COMPLY WITH FBC A 1004, REVISE TO SHOW COMPLIANCE. | | | | IF DETAILS SUCH AS SPECIFIC TYPES OF MACHINES PROPOSED | | IS NOT AVAILABLE AT THIS TIME, REVISE THE PLAN TO SHOW | | GENERAL COMPLIANCE. INCLUDE NOTES REGARDING COMPLIANCE. | | THIS PERMIT WILL BE ISSUED WITH PROVISO, ISSUED AT | | CONTRACTOR'S RISK, PROVIDE A DETAILED PLAN AT | | INSPECTION. SUBJECT TO FIELD INSPECTOR'S DISCRETION, | | FITNESS CENTER PLAN MAY BE REQUIRED TO BE SUBMITTED FOR | | PLAN REVIEW. | | | | 2ND REVIEW, CLEAR FLOOR SPACE WAS ADDED BUT IS ALMOST | | ILLEGIBLE. PLEASE DARKEN THESE LINES, AT LEAST TO THE | | GREY VALUE OF THE EQUIPENT. IT'S ABOUT .25 DARKNESS OF | | THE EQUIPMENT WHICH IS ABOUT .5 COMPARED TO THE | | BLACKLINES. | | | | I WAS UNABLE TO LOCATE NOTES REGARDING COMPLIANCE; | | PLEASE ADD NOTE OR PROVIDE ALL INFORMATION FOR REVIEW. | | | | 8. OK | | | | 9. ADVISORY; ENGINEER ADDED A NOTE RE: FRT FOR ALL | | WOOD. SEE SHEET S2.02A-R, PORTE COCHERE ROOF FRAMING | | NOTES, HEAVY TIMBER FRAMING PROPOSED. PLEASE NOTE THAT | | THIS IS ALSO REQUIRED TO BE FRT; PLAN HAS BEEN REDLINED | | IN THIS AND OTHER LOCATIONS. | | | | 10-11. OK | | | | 12. COMMENT FROM FIRST REVIEW: SOIL BEARING VALUES. THE | | TEST BY UNIVERSAL ENGINEERING SCIENCES REFERENCES THE | | TEST IS PRELIMINARY GEOTECHNICAL ENGINEERING REPORT | | BANYAN CAY- HOTEL PLEASE NOTE THE BORING SAMPLES TAKEN | | CH-1 AND CH-2 ARE SHOWN FOR THE CLUBHOUSE, THIS SOILS | | REPORT HAS NO BORINGS SHOWN IN THE REPORT FOR THE | | HOTEL. NOTE FOR THE TENNIS CLUB CENTER UP TO 6 FEET OF | | MUCK WAS ENCOUNTERED WITHIN THE BUILDING FOOTPRINT. | | PLEASE COMPLY WITH: 2014 FBC-B 1803.3 BASIS OF | | INVESTIGATION. | | SOIL CLASSIFICATION SHALL BE BASED ON OBSERVATION AND | | ANY NECESSARY TESTS OF THE MATERIALS DISCLOSED BY | | BORINGS, TEST PITS OR OTHER SUBSURFACE EXPLORATION MADE | | IN APPROPRIATE LOCATIONS. ADDITIONAL STUDIES SHALL BE | | MADE AS NECESSARY TO EVALUATE SLOPE STABILITY, SOIL | | STRENGTH, POSITION AND ADEQUACY OF LOAD-BEARING SOILS, | | THE EFFECT OF MOISTURE VARIATION ON SOIL-BEARING | | CAPACITY, COMPRESSIBILITY, LIQUEFACTION AND | | EXPANSIVENESS. | | | | 2ND REVIEW, NOT ADDRESSED. ENGINEER OF RECORD IS TO | | REVIEW THE SOILS, EITHER WITH A SHOP DRAWING REVIEW | | STAMP OR BY INCORPORATING A REFERENCE INTO THE PLAN. | | THE SOILS REPORT WAS PROVIDED FOR THE FOUNDATION PERMIT | | APPLICATION (17010911). AFTER THE FOUNDATION PERMIT IS | | ISSUED, THE SOILS WILL BE PUBLIC RECORD AND IS NOT | | NEEDED FOR THIS PERMIT. IF YOU RESUBMIT PRIOR TO | | ISSUANCE OF FOUNDATION PERMIT, PLEASE INCLUDE IN YOUR | | RESUBMITTAL. | | | | 13-15. OK | | | | | | 16. SEE FBC A 209.2.1, 209.4, LABEL ALL PASSENGER | | LOADING ZONES ON THE PLAN, REVISE PLAN TO SHOW | | COMPLIANCE WITH REQUIREMENTS. | | | | 2ND REVIEW, PLEASE SUBMIT REQUEST FOR AN ALTERNATE | | DESIGN TO BE ACCEPTED VIA EMAIL. THE LETTER SHOULD | | INCLUDE A PLAN SHOWING WHAT IS PROPOSED ALONG WITH THE | | HOTEL SOP FOR THE LOADING ZONE ALONG WITH RATIONALE. | | | | 17-24. OK | | | | 25. COMMENT FROM FIRST REVIEW: SHEET A5.1.04 IS BLANK, | | FBC 107 PROVIDE INFORMATION INCLUDING PANIC HARDWARE | | FBC B 1008.1.10. | | | | 2ND REVIEW: A5.1.04 HAS BEEN UPDATED, BUT REFERS TO | | HARDWARE SETS. HARDWARE SETS ARE DESCRIBED ON SHEET | | A5.1.05. A SEARCH OF THE WORD "PANIC" AND "FIRE" | | YIELDED NO RESULTS. | | | | TO EXPEDITE PLAN REVIEW: IF AN ADDITIONAL COLUMN WITH | | "PANIC BAR" OR "FIRE EXIT HARDWARE" IS ADDED, AND A | | MARK TO INDICATE WHICH DOORS WILL HAVE PANIC BARS, IN | | PLAN REVIEW A SPOT CHECK WILL BE DONE, AND A PROVISO | | ADDED (ALL DOORS AND GATES IN THE MEANS OF EGRESS FOR | | ASSEMBLY OCCUPANCY, ELECTRICAL ROOMS, STAIRS, AND OTHER | | LOCATIONS REQUIRED ARE TO HAVE PANIC BARS OR FIRE EXIT | | HARDWARE IN ACCORDANCE WITH FBC B 1008.1.10). | | | | 26. BUILT IN BENCHES TO COMPLY WITH FBC A 903. | | 27. DRESSING, FITTING AND LOCKER ROOMS TO COMPLY WITH | | FBC A 222, REVISE PLAN TO SHOW COMPLIANCE. | | 28. SPA RECEPTION/ RETAIL DESK, ANY OTHER CHECK OUT | | AREAS, SEE FBC A 904 NOTE ON PLAN AND PROVIDE A DETAIL | | 2ND REVIEW: RESPONSE TO 26, 27, 28 REFERS TO D SHEETS; | | THESE PAGES ARE NOT SIGNED AND SEALED AND IT IS NOT | | CLEAR WHO IS TAKING RESPONSIBILITY FOR THE PAGES. | | PLEASE REMOVE THE SHEETS AS IT APPEARS MOST OF THE | | INFORMATION IS NOT REQUIRED. ITEMS 26, 27, AND 28 CAN | | BE A PROVISO ITEM. | | | | 29. OK | | | | 30. ARCHITECT'S TITLE BLOCK LACKS THE ARCHITECT | | BUSINESS NUMBER, REVISE TO INCLUDE, FS481, FAC 61G16. | | | | 2ND REVIEW, AR7073 IS THE ARCHITECT'S LICENSE NUMBER AS | | AN INDIVIDUAL. THE FIRM, ADACHE GROUP ARCHITECTS, IS | | REQUIRED TO HAVE A ARCHITECT BUSINESS NUMBER. PER DBPR | | WEBSITE, THIS IS AA26002281. PLEASE ADD THIS NUMBER TO | | ALL SHEETS, BUT ONLY UPLOAD PAGES WHICH CHANGE DUE TO | | COMMENTS TO AVOID A LENGTHY 3RD REVIEW CYCLE. | | | | 31. SEE SIGNATURE REVIEW. | | | | 32. 2ND REVIEW; THE CERTIFICATE OF AUTHORIZATION IS | | LACKING (FMEP), FS471, FAC61G15-23. PLEASE ADD TO ALL | | SHEETS, BUT ONLY UPLOAD PAGES WHICH CHANGE DUE TO | | COMMENTS. | | | | 33. OK | | | | 34. SEE SIGNATURE REVIEW. | | | | 35. SEE IMPACT FEE REVIEW. | | | | NEW COMMENTS | | | | 37. 05.31.2017 BCR FOOD SERVICE SPECIFICATIONS AND | | 11.25.2016 BCR FOOD SERVICE PROPOSED LAYOUT WERE | | UPLOADED INTO THE "DRAWINGS" FOLDER RATHER THAN | | "SUPPORTING DOCUMENTS"; PLEASE MOVE (OR REMOVE) FROM | | DRAWINGS FOLDER AND ENSURE THAT ALL REQUIRED | | INFORMATION IS IN THE SUPPORTING DOCUMENTS FOLDER. | | | | 38. FBC B 603.1, A4.4.02 DETAIL 12 SHOWS POLYSTYRENE | | OUTRIGGER AT METAL ROOFS AND POSSIBLY OTHER LOCATIONS, | | OTHER DETAILS. PLEASE PROVIDE MORE INFORMATION VIA | | EMAIL REGARDING HEIGHT OF LOCATIONS PROPOSED (OVER | | 30'?), OVER EXITS. A4.4.03 SHOWS EXTERIOR FOAM; PROVIDE | | INFORMATION VIA EMAIL. ARE THESE PRODUCTS | | NONCOMBUSTIBLE? | | | | 39. ADVISORY ONLY, NEW SHEET A4.5.03 DETAIL 8 SHOWS A 1 | | HOUR GLASS WALL AND REFERS TO WATER CURTAIN WALL. NOTE | | THAT THE GLASS DETAIL SHOWS HORIZONTAL MULL BARS. | | PLEASE NOTE THAT, IF THIS OPTION IS ELECTED VIA A | | REVISION, EITHER THE HORIZONTAL MULL BARS ARE TO BE | | REMOVED OR DOR IS REQUIRED TO REVIEW SPRINKLER HEAD | | SPEC SHEETS TO CONFIRM THAT HORIZONTAL MULLIONS ARE | | PERMITTED. IF THIS OPTION IS ELECTED VIA A REVISION, | | PLANS ARE TO BE REVISED AND THE WINDOW SPRINKLER SPEC | | SHEET IS TO BE SUBMITTED. | | | | 40. FBC 107, NEW SHEET 3-A4.5.04 SHOWS "CONTENTIOUS | | WOOD BLOCKING", CLARIFY OR REVISE (DO YOU MEAN | | CONTINUOUS?). | | | | 41. ADVISORY ONLY; SHEET D0.0.00 SHOWS A PLATFORM BED. | | IT IS NOT CLEAR IF THIS BED COMPLIES WITH FBC A | | 806.4(II), OPEN-FRAME TYPE BEDS REQUIRED. THIS WILL BE | | A PROVISO ITEM. | | | | 42. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | THIS IS COMPLETE. | | | | B. SEPARATE PERMITS REQUIRED. SUB PERMITS FOR | | MECHANICAL, ELECTRICAL, PLUMBING ARE REQUIRED. SEPARATE | | PERMITS (APPLICATION, FEES, PLANS, REVIEWS) REQUIRED | | FOR ALL OTHER ITEMS SUCH AS PARKING, SIGNAGE, ETC. | | | | C. COMPLIANCE WITH FBC B 1006, MEANS OF EGRESS | | ILLUMINATION, INCLUDING EXIT DISCHARGE, REQUIRED. | | | | D. VOICE EVAC REQUIRED (NOTE 35, SHEET E3.1.02). | | | | E. ADVISORY ONLY; THE LANDSCAPE PLANS APPEAR TO | | CONFLICT WITH THE EXIT DISCHARGE. LANDSCAPE PERMIT | | REQUIRES A SEPARATE SUBMITTAL; PERMIT APPLICATION, | | FEES, AND PLANS AND ARE NOT REVIEWED BY BUILDING. | | | | F. PRODUCT APPROVALS FOR ALL COMPONENTS AND CLADDING | | ARE TO BE SUBMITTED, REVIEWED BY DESIGNER OF RECORD, | | REVIEWED AND ISSUED PRIOR TO INSTALLATION. | | | | G. SHORING/RESHORE ENGINEERING ARE REQUIRED TO BE | | SUBMITTED, REVIEWED, AND ISSUED PRIOR TO INSTALLATION. | | FAILURE TO DO SO WILL RESULT IN A STOP WORK ORDER. | | | | H. AN ENGINEERED CONSTRUCTION GUARD RAIL DETAIL IS | | REQUIRED PRIOR TO INSTALLATION. THIS MAY BE SUBMITTED | | AS A SUBMITTAL ALONG WITH THE SHORING/RESHORE, BUT MAY | | BE PROVIDED IN THE FIELD TO KEN CONRAD, SUBJECT TO HIS | | APPROVAL. | | | | I. RECORDED REPLAT REQUIRED PRIOR TO C.O.; PROVIDE | | BOOK/PAGE VIA EMAIL. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-04-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-24 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-17 |
Time |
07:24 |
Sent To |
|
|
Notes |
2017-04-24 17:36:11 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | W. P. B. PERMIT: 17020796 (BANYAN CAY HOTEL) | | ADD: 3200 N. CONGRESS AVE. (ADDRESS TO BE ASSIGNED) | | CONT: HEDRICK BROTHERS | | TEL: 561-689-8880 | | E-MAIL: [email protected] | | | | 1. REVISE SITE PLAN TO SHOW DISTANCE TO PROPERTY LINE | | OR ASSUMED PROPERTY LINE BETWEEN BUIDINGS LOCATED ON | | THE SAME LOT, DISTANCE OF PROPOSED HOTEL TO PROPERTY | | LINE AND/OR ASSUMED PROPERTY LINE, DISTANCE OF ADJACENT | | STRUCTURES TO ASSUMED PROPERTY LINE (IF APPLICABLE), | | FBC B TABLE 602, 705.3. | | | | 2. A1.2.01 EXIT DISCHARGE NOT CLEAR; REVISE PLAN TO | | SHOW COMPLIANCE WITH FBC B 1027. | | | | 3. ACCESSIBLE MEANS OF EGRESS SELECTED NOT CLEAR; SEE | | FBC 1007, FBC A 207.1. REVISE PLAN TO STATE WHICH | | METHOD IS SELECTED AND CONFIRM COMPLIANCE WITH METHOD | | SELECTED; REVISE PLAN IF NECESSARY TO SHOW COMPLIANCE. | | | | 4. A1.2.01 1ST FLOOR SQUARE FOOT AREA IS 31,750, | | PROJECT DATA SHOWS 41,956. OTHER FLOORS ALSO | | INCONSISTENT. REVISE TO CLARIFY DISCREPANCY, FBC 107. | | | | 5. SOME AREAS WERE NOT INCLUDED ON THE OCCUPANT LOAD | | CHART; FOR INSTANCE, HOUSEKEEPING. ALTHOUGH OCCUPANT | | LOADS FOR THESE AREA WILL BE LOW, THEY SHOULD BE | | INCLUDED FOR AN ACCURATE TOTAL. THIS INFORMATION IS | | REQUIRED FOR CO. | | | | 6. A1.2.01, CLARIFY FIRE RATED WALL AT RETAIL/COFFEE. | | THIS, AND SOME OTHER FIRE RATED WALLS ARE NOT CLEAR AS | | TO PURPOSE OR CONTINUITY, FBC 107. IF YOU WISH, PLEASE | | CONTACT ME TO DISCUSS PRIOR TO RESUBMITTAL. FOR | | INSTANCE, 2 HOUR BETWEEN MENS ROOM 1149 AND SALE & | | ADMIN 1142, 1 HR BETWEEN BOARD RM #1 AND MEETING ROOM | | #2. | | | | ALL FIRE RATED WALLS, PARTITIONS, BARRIERS SHOWN ON THE | | PLAN WILL BE ENFORCED AS SUCH AT TIME OF INSPECTION. | | | | 7. A1.4.01B, FITNESS ROOM TO COMPLY WITH FBC A 1004, | | REVISE TO SHOW COMPLIANCE. | | | | IF DETAILS SUCH AS SPECIFIC TYPES OF MACHINES PROPOSED | | IS NOT AVAILABLE AT THIS TIME, REVISE THE PLAN TO SHOW | | GENERAL COMPLIANCE. INCLUDE NOTES REGARDING COMPLIANCE. | | THIS PERMIT WILL BE ISSUED WITH PROVISO, ISSUED AT | | CONTRACTOR'S RISK, PROVIDE A DETAILED PLAN AT | | INSPECTION. SUBJECT TO FIELD INSPECTOR'S DISCRETION, | | FITNESS CENTER PLAN MAY BE REQUIRED TO BE SUBMITTED FOR | | PLAN REVIEW. | | | | 8. A1.4.02A WALL BETWEEN CORRIDOR AND AREA "OPEN TO | | BELOW" LACKS A WALL TAG, FBC 107. | | | | 9. S2.04B, A4.2.01, OTHER PAGES, PLAN SPECS LUMBER IN | | SEVERAL LOCATIONS (T&G SHEATHING, PLYWOOD, PRESSURE | | TREATED PLYWOOD, WOOD TRUSS). FBC 603.1, REVISE PLAN TO | | SPEC FRT OR REVISE PLAN INCLUDE EXCEPTION. | | | | 10. S2.04BT SPECS LIGHT GAUGE METAL TRUSSES, S2.04 | | NOTES SPECS WOOD TRUSSES FOR MANSARD. REVISE PLAN TO | | CLARIFY; CHECK ALL FOR CONSISTENCY, FBC 107. SEE ALSO | | A4.2.01. | | | | 11. THRESHOLD BLDG., REQUIRED STATEMENT: | | FS553.79(7)(D), W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS | | FOR THE BUILDING WHICH ARE REQUIRED TO BE SIGNED AND | | SEALED BY THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A | | STATEMENT THAT, TO THE BEST OF THE ARCHITECT'S OR | | ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS | | COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND | | THE APPLICABLE FIRESAFETY STANDARDS AS DETERMINED BY | | THE LOCAL AUTHORITY IN ACCORDANCE WITH THIS CHAPTER AND | | CHAPTER 633. | | | | SEE ALSO THRESHOLD REVIEW FOR ADDITIONAL REQUIREMENTS | | (SI AGREEMENT, RESUMES, ETC.). | | | | 12. SOIL BEARING VALUES. THE TEST BY UNIVERSAL | | ENGINEERING SCIENCES REFERENCES THE TEST IS PRELIMINARY | | GEOTECHNICAL ENGINEERING REPORT BANYAN CAY- HOTEL | | PLEASE NOTE THE BORING SAMPLES TAKEN CH-1 AND CH-2 ARE | | SHOWN FOR THE CLUBHOUSE, THIS SOILS REPORT HAS NO | | BORINGS SHOWN IN THE REPORT FOR THE HOTEL. NOTE FOR THE | | TENNIS CLUB CENTER UP TO 6 FEET OF MUCK WAS ENCOUNTERED | | WITHIN THE BUILDING FOOTPRINT. PLEASE COMPLY WITH: 2014 | | FBC-B 1803.3 BASIS OF INVESTIGATION. | | SOIL CLASSIFICATION SHALL BE BASED ON OBSERVATION AND | | ANY NECESSARY TESTS OF THE MATERIALS DISCLOSED BY | | BORINGS, TEST PITS OR OTHER SUBSURFACE EXPLORATION MADE | | IN APPROPRIATE LOCATIONS. ADDITIONAL STUDIES SHALL BE | | MADE AS NECESSARY TO EVALUATE SLOPE STABILITY, SOIL | | STRENGTH, POSITION AND ADEQUACY OF LOAD-BEARING SOILS, | | THE EFFECT OF MOISTURE VARIATION ON SOIL-BEARING | | CAPACITY, COMPRESSIBILITY, LIQUEFACTION AND | | EXPANSIVENESS. | | | | 13. SHEET 019-S-4.10, PRESSURES MAY BE LOW; PROVIDE | | CALCULATIONS FBC B 1609. REVISE PLAN TO INCLUDE PITCH | | AND MEAN ROOF HEIGHT. WILL DESIGN PRESSURES SPECIFIED | | APPLY TO ALL ROOF AREAS, REGARDLESS OF PITCH? ROOF PLAN | | APPEARS TO INCLUDE ROOF AREAS OVER THE 4TH LEVEL, BUT | | OTHER ROOF AREAS ARE NOT INCLUDED - FOR EXAMPLE, THE | | PORTE COCHERE. REVISE PLAN TO INCLUDE ALL ROOF AREAS. | | | | 14. SOME SECTION DETAIL MARKERS APPEAR TO BE LABELED | | INCORRECTLY AND DETAILS DO NOT CORRELATE WITH FLOOR | | PLANS; FOR INSTANCE, SEE SHEET S2.00A. DETAIL MARKERS | | REFERENCE PAGES S3.40, S3.41, UNABLE TO LOCATE; S4.08 | | AND OTHER PAGES ALSO HAVE THIS ERROR. SEE SHEETS S3.42 | | AND OTHER PAGES, UNABLE TO LOCATE THE SHEARWALL | | LOCATIONS ON THE PLAN, REVISE OR DIRECT. | | | | 15. A1.8.01 AND OTHER PAGES PROVIDE A LEGEND FOR THE | | FLOOR PLAN NOTE (THE BOX IN THE MIDDLE OF EACH FLOOR | | PLAN). IT IS NOT CLEAR WHAT "P-1" MENAS. SOME AREAS | | HAVE A "?"; CLARIFY. | | | | 16. SEE FBC A 209.2.1, 209.4, LABEL ALL PASSENGER | | LOADING ZONES ON THE PLAN, REVISE PLAN TO SHOW | | COMPLIANCE WITH REQUIREMENTS. | | | | 17. FBC A 806, REVISE PLAN TO SHOW COMPLIANCE. SOME ADA | | ROOMS HAVE ACCESSIBILITY CLEAR FLOOR SPACE (4-1.5.02), | | OTHERS DO NOT (3-1.5.02). | | | | 18. FBC 107, NO DETAILS FOR TUB, SHOWER, LAV, TOILETS, | | URINALS PROVIDED. SEE PLUMBING REVIEW; ALL ARE | | APPLICABLE FOR BUILDING REVIEW. | | | | 19. FBC A 806, PROVIDE A DETAIL TO SHOW COMPLIANCE, | | ACCESSIBLE ROUTE TO GUEST ROOM BALCONY. THIS SHOULD | | CORRELATE WITH THE SLIDING GLASS DOOR PRODUCT APPROVAL. | | THE DETAIL ON A5.2.01 DOES NOT INCLUDE DIMENSIONS TO | | SHOW COMPLIANCE WITH FBC A 303. ALSO PROVIDE THE | | SLIDING GLASS DOOR PRODUCT APPROVAL. | | | | 20. 4-A1.5.05, REVISE PLAN TO CLARIFY WHAT "ELEV #5" | | AND "ELEV #3" ARE. | | | | 21. A1.2.02, THE RATED WALL REQUIRED BY FBC B 708.1 IS | | NOT CONTINUOUS FOR SOME ROOMS (ROOMS NOT NUMBERED, SEE | | LINES C8 THROUGH C10). | | | | 22. COMPLIANCE WITH FBC 1509.6.4 (ROOFTOP EQUIPMENT) | | NOT CLEAR, REVISE PLAN TO CLARIFY. | | | | 23. ADVISE AS TO WHERE THE DOOR MARKERS FOR THE UNITS | | CAN BE FOUND, FBC 107. LOCATION OF "BARN" DOORS IN THE | | UNITS IS NOT CLEAR. | | | | 24. REVISE PLAN TO INCLUDE ASSEMBLIES FOR THE FIRE | | RATED ELEMENTS REQUIRED BY FBC B TABLE 601. | | | | 25. SHEET A5.1.04 IS BLANK, FBC 107 PROVIDE INFORMATION | | INCLUDING PANIC HARDWARE FBC B 1008.1.10. | | | | 26. BUILT IN BENCHES TO COMPLY WITH FBC A 903. | | | | 27. DRESSING, FITTING AND LOCKER ROOMS TO COMPLY WITH | | FBC A 222, REVISE PLAN TO SHOW COMPLIANCE. | | | | 28. SPA RECEPTION/ RETAIL DESK, ANY OTHER CHECK OUT | | AREAS, SEE FBC A 904 NOTE ON PLAN AND PROVIDE A DETAIL. | | | | 29. CIVIL SHEETS USE NGVD29 VERTICAL DATUM. A0.0.02 | | PROPOSES A FINISHED FLOOR OF 22'0' NAVD88. THERE IS A | | CONFLICT OF APPROXIMATELY 18"; REVISE TO BE CONSISTENT. | | NGVD29 IS RECOMMENDED AT THIS TIME. | | | | 30. ARCHITECT'S TITLE BLOCK LACKS THE ARCHITECT | | BUSINESS NUMBER, REVISE TO INCLUDE, FS481, FAC 61G16. | | | | 31. CIVIL, STRUCTURAL, AND ARCHITECTURAL (AND OTHER) | | SHEETS ARE NOT DIGITALLY SIGNED. A SHEETS APPEAR TO BE | | DIGITALLY SIGNED BUT LACK THE CERTIFICATE. PRIOR TO | | RESUBMITTAL, PLEASE DIGITALLY SIGN EACH SHEET. IF | | UNSURE AS TO ACCEPTABLE (PER FS471/FS481) FORMAT, | | PLEASE SEND TEST PAGES TO ME VIA EMAIL FOR PRELIMINARY | | REVIEW. FAILURE TO PROVIDE INDIVIDUALLY SIGNED PAGES | | WILL RESULT IN A SEPARATE SIGNATURE REVIEW AFTER ALL | | REVIEWS HAVE PASSED. THIS REVIEW MAY TAKE UP TO A WEEK | | TO COMPLETE. INDIVIDUALLY SIGNED PAGES IS STRONGLY | | ENCOURAGED IN ORDER TO TIMELY PROCESS THIS PERMIT. | | PLEASE FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS | | OPTIONS. | | | | 32. IT IS NOT CLEAR WHICH OF THE ENGINEERING COMPANIES | | IN THE COMPANY BLOCK IS TO SERVE AS THE TITLE BLOCK FOR | | THE VARIOUS ENGINEERS (FMEP). ALSO, THE CERTIFICATE OF | | AUTHORIZATION IS LACKING, FS471, FAC61G15-23. | | | | 33. OK | | | | 34. SEE SIGNATURE REVIEW. | | | | 35. SEE IMPACT FEE REVIEW. | | | | 36. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | THIS IS COMPLETE. | | | | B. SEPARATE PERMITS REQUIRED. SUB PERMITS FOR | | MECHANICAL, ELECTRICAL, PLUMBING ARE REQUIRED. SEPARATE | | PERMITS (APPLICATION, FEES, PLANS, REVIEWS) REQUIRED | | FOR ALL OTHER ITEMS SUCH AS PARKING, SIGNAGE, ETC. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-16 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-16 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2018-08-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-24 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-24 |
Time |
12:29 |
Sent To |
|
|
Notes |
2018-08-24 12:29:00 | REVIEWED PER PREVIOUS COMMENTS ONLY. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. REVISION SHOWS MAIN #1 AS 1200 AMPS. THE FEEDERS TO | | THIS MAIN ARE SHOWN AS 3 SETS OF 400KCMIL COPPER, WHICH | | HAS AN AMPACITY OF 1005 AMPS. PROVIDE CORRECTION. NEC | | 240.4(C) | | 2. NOTE 12 ON RISER DIAGRAM SHOWS THE GENERATOR AS A | | 120/208 VOLT, 3 PHASE GENERATOR. HOWEVER, THIS | | GENERATOR IS SHOWN FEEDING 277/480 VOLT, 3 PHASE LOADS. | | PROVIDE CORRECTION. WPB FBC 107.2.1 | | 3. EXPANDED VIEW OF MAIN ELECTRICAL ROOM, IN THE | | EMERGENCY AREA, PLAN DOES NOT SHOW THE REQUIRED 4 FEET | | OF CLEARANCE BETWEEN PANELS AND ATS. PROVIDE | | CORRECTION. NEC 110.26(A)(1) | | | | ALL OTHER COMMENTS HAVE BEEN ADDRESSED SATISFACTORILY. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-04-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-04-30 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-04-27 |
Time |
09:29 |
Sent To |
|
|
Notes |
2018-04-30 16:39:04 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NEED A RISER DIAGRAM SHOWING ALL OF THE FIREPUMP AND | | CONTROLER, PLEASE INDICATE THE SIZES HP RATING, WIRE | | SIZES, OVERCURRENT PROTECTION, ECT, ECT | | | | ARC FLASH MITIGATION REQUIRED ON MAINS PER 240.87 | | | | FAULT CURRENT CALCLULATION PER 110.10 FOR THE SERVICE | | AND DOWNSTREAM PANELS. | | | | RISER SHOWS PANEL ISHB DIFFERENT THAN THE OTHER PANEL ? | | IS THIS A SPECIAL PANEL? |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-04-11 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-04-11 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-04-11 |
Time |
09:18 |
Sent To |
|
|
Notes |
2017-04-11 09:18:36 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 | | COMMENTS: | | | | 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE | | PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE | | PERMITS AND DATA CUT SHEET SUBMITTALS FOR ALL SITE | | LIGHTING AND ASSOCIATED EQUIPMENT, GENERATOR, ALL LOW | | VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED TO FIRE | | ALARM, ACCESS CONTROLS, CCTV, PHONE AND DATA, SIGNAGE, | | WIRELESS SYSTEMS, ELEVATORS, KITCHEN HOOD SYSTEMS, ETC. | | A NOTE WILL SUFFICE. | | 2. SHEET E0.0.02- PLEASE ADD A GENERAL NOTE TO SHEET TO | | INDICATE THE REQUIREMENTS OF NEC 300.5D3 AND TABLE | | 300.5 FOR MINIMUM COVER REQUIREMENTS FOR CONDUITS AND | | THE PLACEMENT OF A WARNING RIBBON FOR THE SERVICE | | LATERAL CONDUCTORS SHOWN FOR THIS PROJECT. A NOTE WILL | | SUFFICE | | 3. SHEET E0.0.02- ADD A NOTE TO MAINTAIN ALL ELECTRICAL | | EQUIPMENT ABOVE THE BASELINE FLOOD ELEVATION PER STATE | | AND CITY REGULATORY AGENCIES. | | 4. SHEET E0.0.02- PLEASE CORRECT ALL CODES APPLICABLE | | REFERENCES TO REFLECT ABOVE STATED. DELETE BROWARD AND | | INTERNATIONAL CODES. ADD WPB AMENDMENTS. | | 5. NOTE THAT PLANS ARE NOT DIGITALLY SIGNED AND SEALED. | | FBC 107.3.5 | | 6. E1.3.01B- PLEASE PROVIDE EM LIGHTING FOR MAIN | | ELECTRICAL ROOM AND ELECTRICAL ROOMS. FBC 107.3.5 | | 7. ALL BALCONIES MUST HAVE A RECEPTACLE OUTLET, SEE ALL | | UNITS. NEC 210.52E3. | | 8. PROVIDE A NOTE TO COMPLY WITH NEC 210.5- | | IDENTIFICATION FOR BRANCH CIRCUITS- A- GROUNDED | | CONDUCTOR PER NEC 200.6 AND UNGROUNDED CONDUCTORS PER | | NEC 210.5C1,2,3- APPLICATION, MEANS OF IDENTIFICATION | | AND POSTING OF IDENTIFICATION MEANS. | | 9. PROVIDE A NOTE ON UNIT SHEETS TO INDICATE TAMPER | | RESISTANT RECEPTACLE REQUIRED PER NEC 406.13 | | 10. SHOW A MASTER SWITCH FOR ALL UNITS AT THE ENTRY PER | | FBC EC405.2.3 LIGHTING AND SWITCHED RECEPTACLE. SHOW | | COMPLIANCE. | | 11. SHEET E-2.2.00- PROVIDE A NOTE INDICATING GFCI | | PROTECTION REQUIRED WITHIN 6FT OF EVERY SINK PER NEC | | 210.8B5, AND FOOD PREPARATION ADJACENT AREAS. | | 12. RISER DIAGRAM AND PANEL SCHEDULES SHEETS. PLEASE | | PROVIDE AVAILABLE FAULT CURRENT AVAILABLE AT THE FPL | | SERVICE. ATTACH TO DOCUMENTS LETTER FROM FLORIDA POWER | | & LIGHT INDICATING AIC. SHOW AIC CALCULATION BASED ON | | INFORMATION PROVIDED BY UTILITY FOR APPROVAL. NEC | | 110.24 FBC 107.3.5 | | 13. AIC RATINGS REQUIRED TO BE SHOWN ON ALL | | PANELBOARDS. FBC 107.3.5 | | 14. PROVIDE ACTUAL VOLTAGE DROP CALCULATIONS NOT ONLY | | FOR FEEDERS BUT ALSO THE BRANCH CIRCUIT FBC EC 505.7 | | 15. MAIN ELECTRICAL ROOMS MUST COMPLY WITH NEC | | 110.26C3, REQUIRES PERSONNEL DOORS TO BE EQUIPPED WITH | | PANIC HARDWARE AND OPEN IN THE DIRECTION OF EGRESS. A | | NOTE WILL SUFFICE. | | 16. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM | | TO INDICATE NEC 110.16. ARC FLASH WARNING SIGNS AND NEC | | 110.24- AVAILABLE FAULT CURRENT- FIELD MARKINGS; SEE | | VERBIAGE IN CODE. | | 17. PLEASE CLARIFY FIRE PUMP SHOWN ON RISER DIAGRAM FOR | | A COMPLETE REVIEW. COULD NOT LOCATE WHERE IT IS | | LOCATED, AND LOCATION OF ATS/FP CONTROLLER. FBC 107.3.5 | | 18. PROVIDE INFORMATION ON DRAWINGS AND DATA SHEETS FOR | | LIGHTING CONTROL PANELS. CLARIFY COMPLIANCE WITH FBC | | ENERGY CONSERVATION. | | 19. CLARIFY AS NO ELEVATOR MACHINE ROOMS ARE SHOWN TO | | COMPLY WITH NEC 620.23 A,B AND C. | | 20. ADDRESS FIRE AND MECHANICAL COMMENTS RELATED TO | | ELECTRICAL.ADDITIONAL EXIT LIGHTS AND EM. PHOTOMETRICS | | FOR MINIMUM EGRESS LIGHTING LEVELS TO BE | | MAINTAINED.SHOW ADDITIONAL ELECTRICAL DEMAND FOR DUCT | | DETECTORS AND DAMPERS MISSING AND ROOFTOP ELECTRICAL | | RECEPTACLES FOR SERVICE OF EQUIPMENT IN AREA. NEC | | 210.63, FBC 107.3.5 | | 21. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL | | FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS | | REGARDING THIS PROJECT. | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2018-09-12 |
|
|
Cont ID |
|
Sent By |
RRossano |
Date |
2018-09-12 |
Time |
|
Rev Time |
1.00 |
Received By |
rrossano |
Date |
2018-09-12 |
Time |
|
Sent To |
I |
|
Notes |
2018-09-12 12:24:37 | UNDER REVIEW IN ENGINEERING. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2018-05-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-07 |
Time |
06:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-07 |
Time |
06:19 |
Sent To |
|
|
Notes |
2018-05-07 06:19:37 | APPROVAL BY ENGINEERING REQUIRED | | ENGINEERING REVIEW WILL BE DONE VIA A FORMAL | | ENGINEERING SUBMITTAL | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2017-05-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-05-11 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-05-11 |
Time |
13:37 |
Sent To |
|
|
Notes |
2017-05-11 13:38:02 | APPROVAL BY ENGINEERING REQUIRED | | ENGINEERING REVIEW WILL BE DONE VIA A FORMAL | | ENGINEERING SUBMITTAL | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-10-16 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-10-16 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2018-08-08 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-08-08 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-08-08 |
Time |
10:15 |
Sent To |
|
|
Notes |
2018-08-08 10:18:23 | SEE COMMENTS FROM FIRE REVIEW ON 5/17/18. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-05-17 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-05-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-04-25 |
Time |
16:34 |
Sent To |
|
|
Notes |
2018-05-17 13:37:25 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | THE PREVIOUS COMMENTS OF FIRE PREVENTION APPEARED TO | | HAVE BEEN ADDRESSED. | | | | THIS APPROVAL DOES NOT SUPERSEDE THE RESPONSIBILITY TO | | MEET THE REQUIREMENTS OF ANYLLIFE SAFETY CODE AS THE | | CONSTRUCTION PROOJECT PROGESSES AND DETAILED FIRE | | INSPECTIONS FIND COMFLICTS. | | | | DEFICIENCIES FOUND IN CONFLICT WITH THE CODE SHALL | | REQUIRE CORRECTIONS OR MODICIFCATIONS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-03-24 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-03-24 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-03-22 |
Time |
16:16 |
Sent To |
|
|
Notes |
2017-03-23 11:31:25 | 3200 NORTH CONGRESS AVENUE - HOTEL | | PERMIT #17020796 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK INFORMATION. | | | | NO INFORMATION SUBMITTED FOR POOL, POOL DECK, WEDDING | | STAGE, CONCERT LAWN, EVENT TENT, PHASE II OR PARKING | | GARAGE. THESE AREAS HAVE NOT BEEN REVIEWED OR APPROVED | | AT THIS TIME. | | | | PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN | | TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE | | PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE | | PROVIDED AS REQUIRED BY THE AUTHORITY HAVING | | JURISDICTION. | | TEMPORARY CONSTRUCTION TRAILERS OR MODULAR BUILDINGS | | WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE | | FOLLOWING: | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | PER TABLE 4.2.1: | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | PER NFPA 241 SECTION 8.7.2.3, WHERE UNDERGROUND WATER | | MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL BE | | INSTALLED, COMPLETED, AND IN SERVICE PRIOR TO | | CONSTRUCTION WORK. | | | | PER SECTION 18.3.4.1 (NFPA 1), FIRE HYDRANTS SHALL BE | | PROVIDED WITH CLEARANCES OF 7'-6" TO THE FRONT AND | | SIDES AND 4'-0" TO THE BACKSIDE OF THE STEAMER CAP. | | | | PER SECTION 18.2.3.4.1.1 (NFPA 1), FIRE DEPARTMENT | | ACCESS ROADS SHALL HAVE A SURFACE DESIGNED TO | | ACCOMMODATE FIRE APPARATUS WEIGHING AT LEAST 36 TONS. | | ACCESS ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF NOT | | LESS THAN 20 FEET AND AN UNOBSTRUCTED VERTICAL | | CLEARANCE OF NOT LESS THAN 13 FEET 6 INCHES. | | | | PER SECTION 18.2.3.5.3 (NFPA 1), FIRE LANES SHALL BE | | MARKED WITH FREESTANDING SIGNS READING, "FIRE LANE - NO | | PARKING BY ORDER OF THE FIRE DEPARTMENT." SIGNS SHALL | | BE 12" X 18" WITH A WHITE BACKGROUND AND RED LETTERS | | AND SHALL BE A MAXIMUM OF SEVEN FEET IN HEIGHT TO THE | | BOTTOM OF THE SIGN. SIGNS SHALL BE WITHIN SIGHT OF THE | | TRAFFIC FLOW AND BE SPACED A MAXIMUM OF 60 FEET APART. | | | | SHEET A-0.0.02: APPLICABLE CODES SECTION INDICATES, | | "BROWARD COUNTY AMENDMENTS TO THE FLORIDA FIRE | | PREVENTION CODE." | | | | SHEET A-1.2.01: EGRESS PLAN DOES NOT SHOW ENOUGH DETAIL | | REGARDING ALL EXITS DISCHARGING TO A PUBLIC WAY. | | SEVERAL EXIT DISCHARGE APPEAR TO TERMINATE DIRECTLY | | OUTSIDE OF THE BUILDING AND DO NOT PROVIDE A MEANS OF | | EGRESS TO ACHIEVE A SAFE DISTANCE AWAY FROM THE | | BUILDING SUCH AS PRE-FUNCTION #1318, BALLROOM #2, AND | | SALE/ADMIN TO NAME A FEW. | | | | SHEET A-1.2.01: NEARLY HALF THE EXITS DISCHARGE ONTO | | THE POOL DECK IN LIEU OF A PUBLIC WAY. A LIFE SAFETY | | PLAN IS NEEDED FOR THE FIRST FLOOR AND POOL DECK IF THE | | DECK IS TO BE USED HOTEL OCCUPANT EGRESS. HOW WILL | | UNOBSTRUCTED EGRESS BE PROVIDED AND MAINTAINED ON THE | | POOL DECK LEADING TO A PUBLIC WAY? HOW DO THE | | ADDITIONAL LARGE ASSEMBLY SPACES (TIKI BAR, WEDDING | | STAGE, CONCERT LAWN, EVENT TENT AND PHASE II) AFFECT | | TOTAL EGRESS PLAN? | | | | SHEET A-1.2.01: NO FIRE PROTECTION RATING SHOWN AROUND | | FIRE PUMP ROOM. | | | | SHEET A-1.2.02: NO FIRE PROTECTION RATING SHOWN AROUND | | STAIR #3 (TYPICAL UPPER FLOORS) AND ELEVATOR SHAFT AT | | COLUMN INTERSECTION B/24. | | | | SHEET A-1.2.04 & SHEET M-1.3.04B: HOUSEKEEPING #4001 | | NEEDS A TWO-HOUR FIRE RESISTANCE RATING AND 90 MINUTE | | FIRE RATED DOOR. WHERE THE GREASE DUCT SYSTEM CONNECTED | | TO THE IN-LINE EXHAUST FAN IS IN AN ENCLOSURE, THE | | SPACE OR ROOM IN WHICH THE EXHAUST FAN IS LOCATED SHALL | | HAVE THE SAME FIRE RESISTANCE RATING AS THE ENCLOSURE | | (NFPA 96 SECTION 8.1.3.6) | | | | SHEET A-1.3.02: PLANS INDICATE GLAZING WITH A FIRE | | RATING IN SECOND FLOOR CORRIDOR LOOKING DOWN INTO THE | | FIRST FLOOR LOBBY; HOWEVER, NO WALL OR GLAZING DETAILS | | FOR THIS ASSEMBLY WAS LOCATED. | | | | SHEET A-5.1.01: INDIVIDUAL DOORS IN SCHEDULE DO NOT | | INDICATE THE USE OF PANIC OR FIRE EXIT HARDWARE. | | | | SHEET A-5.1.04: SHEET IS BLANK. | | | | SHEET FP-0.0.00: COULD NOT LOCATE ANY OF THE FOLLOWING | | INFORMATION: YEAR OF STANDARD DESIGNED (NFPA 13, 14, 20 | | ETC.0, HYDRANT FLOW TEST DATA, HAZARD AND DENSITY | | CLASSIFICATION OF EACH AREA, FIRE DEPARTMENT | | CONNECTION. | | | | SHEET FP-0.0.00: PLANS INDICATE, "100 PSI @ 500 GPM | | REQUIRED FOR CITY OF MIAMI." | | | | SHEET FP-1.3.01B: PER NFPA 24 SECTION 6.2.1, ALL | | CONNECTIONS TO PRIVATE FIRE SERVICE MAINS FOR FIRE | | PROTECTION SYSTEMS SHALL BE ARRANGED IN ACCORDANCE WITH | | ONE OF THE FOLLOWING SO THAT THEY CAN BE ISOLATED: | | (1)A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40 | | FEET FROM THE BUILDING. | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST | | INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED | | CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE | | BUILDING AS THE HEIGHT OF THE WALL FACING THE POST | | INDICATOR VALVE. | | (2) A WALL POST INDICATOR VALVE | | (3) AN INDICATING VALVE IN A PIT, INSTALLED IN | | ACCORDANCE WITH SECTION 6.4 | | (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING | | VALVE NOT LESS THAN 40 FEET FROM THE BUILDING. | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A | | BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE | | SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET | | BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF | | THE WALL FACING THE BACKFLOW PREVENTER. | | (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM | | ACCESSIBLE FROM THE EXTERIOR | | (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE | | ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE | | AUTHORITY HAVING JURISDICTION | | | | SHEET FP-1.3.01B: CONFIRM FIRE PUMP ROOM IS LARGE | | ENOUGH TO ACCOMMODATE THE FIRE PUMP, JOCKEY PUMP, | | CONTROL PANELS WITH TRANSFER SWITCH, DOMESTIC WATER | | BOOSTER PUMP AND ALL REQUIRED WORKING CLEARANCES. | | | | PLUMBING/FIRE PROTECTION: NEITHER THE FIRE PROTECTION | | DRAWINGS NOR THE PLUMBING DRAWINGS SHOW THE | | SPRINKLER/STANDPIPE SYSTEM DRAINS OR TIE INTO THE | | SANITARY OR SEWER SYSTEMS. | | | | SHEET M-1.3.04B: GREASE DUCT EXHAUST LOUVER IS LOCATED | | CLOSER THAN 10 FEET TO THE ADJACENT PERPENDICULAR | | CORRIDOR WALL. | | | | SHEET M-1.3.04B: HOUSEKEEPING #4001 NEEDS A TWO-HOUR | | FIRE RESISTANCE RATING AND 90 MINUTE FIRE RATED DOOR. | | WHERE THE DUCT SYSTEM CONNECTED TO THE IN-LINE EXHAUST | | FAN IS IN AN ENCLOSURE, THE SPACE OR ROOM IN WHICH THE | | EXHAUST FAN IS LOCATED SHALL HAVE THE SAME FIRE | | RESISTANCE RATING AS THE ENCLOSURE (NFPA 96 SECTION | | 8.1.3.6) | | | | ELECTRICAL: INSUFFICIENT EXIT SIGNAGE THROUGHOUT | | BUILDING, ESPECIALLY THE FIRST FLOOR. NO EMERGENCY | | LIGHTING INDICATED INSIDE OR OUTSIDE THE BUILDING | | EXCEPT INSIDE THE EXIT STAIRS. | | | | SHEET E-1.4.01A: NO FIRE ALARM NOTIFICATION PROVIDED IN | | THE FOLLOWING LOCATIONS: BUILDING EXTERIOR, MEETING | | #1113, RESTROOM #1111, PANTRY FREEZER #1118, RESTROOM | | #1108 (ONE TOILET). | | | | SHEET E-1.4.01B: NO FIRE ALARM NOTIFICATION PROVIDED IN | | THE FOLLOWING LOCATIONS: KITCHEN #1129 (LARGER FREEZERS | | AND DRY STORAGE), SAUNA #1206, SAUNA #1224 | | | | SHEET E-1.4.02: NO FIRE ALARM NOTIFICATION PROVIDED FOR | | THE LARGE OUTSIDE KING BALCONIES (TYPICAL UPPER | | FLOORS). | | | | DISCLAIMER: REVIEW AND APPROVAL BY THE AHJ SHALL NOT | | RELIEVE THE OWNER, CONTRACTOR, ETC. OF THE | | RESPONSIBILITY OF COMPLIANCE WITH CODE (NFPA 1, SECTION | | 1.14.4). FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT | | ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED | | WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, | | ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE | | TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT | | THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A | | CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR | | VIOLATIONS OF THIS CODE. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
5 |
Status |
P |
Date |
2018-11-30 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-11-30 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-11-30 |
Time |
14:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
F |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-11-14 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-11-07 |
Time |
14:51 |
Sent To |
|
|
Notes |
2018-11-14 10:47:09 | 4TH REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | GAS COMMENTS: | | 1. SHT. P-3.0.07 THE GAS RISER DIAGRAM IS LABELED | | PRESSURE 2-4 FL SOUTH. PLEASE CLARIFY WPB AMEND TO FBC | | 107.2.1 | | 2. SHT. P-3.0.07 UNDER THE EQUIPMENT SCHEDULE #304 THE | | BTU LOAD IS ILLEGIBLE. PLEASE CLARIFY WPB AMEND TO FBC | | 107.2.1 | | 3. SHT. P-3.0.07 UNDER THE EQUIPMENT SCHEDULE # 2011, | | 2014 AND 1002 ARE NOT SHOWN ON THE RISER DIAGRAM. | | PLEASE CLARIFY WPB AMEND TO FBC 107.2.1 | | 4. BELOW THE EQUIPMENT SCHEDULE THERE IS A NOTE | | REFERENCING THE KITCHEN CONSULTANT?S DRAWINGS FOR | | EQUIPMENT LOCATION AND FINAL LOADS. FOR THE GAS RISER | | IT IS REQUIRED THAT THE CORRECT BTU LOAD BE INDICATED | | ON THE PLAN AND THEY SHALL MATCH THE KITCHEN | | CONSULTANTS DRAWINGS. PLEASE CLARIFY WPB AMEND TO FBC | | 107.2.1. | | 5. SHT. P-3.0.07 THE BTU LOAD ON THE RISER FOR THE | | BANQUET KITCHEN DETAIL #D DOES NOT MATCH THE TOTAL FROM | | WHEN I ADDED UP THE EQUIPMENT SCHEDULE. PLEASE CLARIFY | | WPB AMEND TO FBC 107.2.1. | | 6. SHT. P-3.0.07 THE BTU LOAD ON THE A BRANCH OFF THE | | MAIN DOES NOT MATCH THE BTU LOAD ON THE ENLARGED | | ISOMETRIC #A . PLEASE CLARIFY WPB AMEND TO FBC 107.2.1. | | 7. SHT. P-3.0.07 THE BTU LOAD ON THE C BRANCH OFF THE | | MAIN DOES NOT MATCH THE BTU LOAD ON THE ENLARGED | | ISOMETRIC #C . PLEASE CLARIFY WPB AMEND TO FBC 107.2.1. | | 8. SHT. P-3.0.07 WHEN I TOTALED UP THE BTU LOADS FROM | | THE EQUIPMENT SCHEDULE IT WAS 4,783,000 THE TOTAL GAS | | LOAD UNDER THE 1ST STAGE GAS LOAD CALCULATION WAS | | 4,624,000 PLEASE CLARIFY WPB AMEND TO FBC 107.2.1. | | | | PREVIOUS COMMENTS 2. SUBMIT CALCULATIONS FOR COMBUSTION | | AIR PER THE FBC-2014 | | FUEL GAS CODE SEC. 304. PLEASE PROVIDE COMBUSTION AIR | | CALC FOR | | THE KITCHEN APPLIANCES. | | RESPONSE: GAS WATER HEATER IS DIRECT VENT/INTAKE. | | PLEASE CONFIRM REQUIREMENT OF CALCULATION. | | PLEASE REFER TO KITCHEN CONSULTANT FOR KITCHEN | | EQUIPMENT INFORMATION. | | THIS RESPONSE DOES NOT COMPLY PLEASE PROVIDE COMBUSTION | | AIR CALCULATIONS FOR THE KITCHENS THEY SHALL BE | | INCLUDED IN THE GAS OR MECHANICAL PLANS. | | | | PREVIOUS COMMENT 4. SUBMIT MANUFACTURER?S SPECIFICATION | | SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | NFPA | | 58, AND FBC-2014 FUEL GAS SEC. 402.2 WE NEED THESE TO | | VERIFY BTU | | LOADS-IF THEY CAN NOT BE PROVIDED FOR PLAN REVIEW PLACE | | A | | NOTE ON THE PLAN TO BE ON JOBSITE FOR FIRST ROUGH | | INSPECTION. | | RESPONSE: PLEASE REFER TO KITCHEN EQUIPMENT CONSULTANT | | PLANS FOR REFERENCE. | | THE RESPONSE DOES NOT COMPLY THE KITCHEN CONSULTANTS | | PLANS ARE NOT INCLUDED IN SUBMITTAL AND WE REQUIRE THE | | SPECIFICATION FROM THE APPLIANCE MANUFACTURE NOT THE | | CONSULTANT. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2018-09-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-09-11 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-09-11 |
Time |
10:30 |
Sent To |
|
|
Notes |
2018-09-11 12:35:15 | 3ND REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: PREVIOUS COMMENTS | | | | PARTIALLY COMPLIED 1. 1. SUBMIT AN ISOMETRIC DRAWING | | THAT CLEARLY SHOWS ALL CUT SECTIONS OF PIPE AND | | CORRESPONDING LENGTHS PER FBC-2014 FUEL GAS, SECS. | | 402.4.1, 402.4.2. AND BTU LOAD OF EACH APPLIANCE. ALSO | | SHOW ALL VALVE DRIP LEGS AND REGULATORS REFER TO THE | | FBC-2014 FUEL GAS SECS. 401.8 THRU 402.6.1 AND TABLES | | 402.4(1) THRU 402.4(37). | | PLEASE PROVIDE THE LENGTH OF EACH CUT SECTION OF PIPE. | | PLEASE SHOW BTU LOAD FOR EACH GAS APPLIANCE.THE NUMBERS | | ON THE ENLARGE BANQUET KITCHEN ISO DO NOT ALL MATCH THE | | GAS EQUIPMENT SCHEDULE. | | | | 2. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. PLEASE PROVIDE | | COMBUSTION AIR CALC FOR THE KITCHEN APPLIANCES. | | | | 3. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | SEC. 502 THRU 505. IN YOUR RESPONSE YOU NOTE VENT | | DETAILS ON SHT P-3.0.08 I COULD NOT LOCATE ANY VENT | | DETAILS ON THAT SHT PLEASE CLARIFY. | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 WE NEED | | THESE TO VERIFY BTU LOADS-IF THEY CAN NOT BE PROVIDED | | FOR PLAN REVIEW PLACE A NOTE ON THE PLAN TO BE ON | | JOBSITE FOR FIRST ROUGH INSPECTION. | | | | 2ND REVIEW COMMENTS: NOT COMPLIED | | | | 1. SHT. P-3.0.08 ON THE GAS ISOMETRIC THE 2ND BRANCH | | UPSTREAM OF THE METER HAS IS LABELED AS MAIN KITCHEN | | SHT. P-1.5.07 WHICH LABELS IT AS THE BANQUET KITCHEN | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 4. WHAT IS THE 3/4" BRANCH WITH THE NOTE FIX TAG PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 5. WHAT IS THE 2" AT THE UPSTREAM END OF THE ISOMETRIC | | WITH THE TAG XXXMBH/L.F.=XX' PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | | | 6. ON THE ENLARGED ISOMETRIC DRAWING PLEASE SHOW THE | | PRESSURE REGULATORS AND THE VALVES ALSO SHOW THE LENGTH | | AND SIZE OF THE PIPING BETWEEN THE REGULATOR AND THE | | APPLIANCE. PER WPB AMEND TO FBC 107.2.1 | | | | 7. PLEASE LABEL THE ENDS OF THE PIPE WHERE THEY | | CONTINUES. PER WPB AMEND TO FBC 107.2.1 | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2018-05-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-05-07 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-05-07 |
Time |
08:31 |
Sent To |
|
|
Notes |
2018-05-07 09:28:26 | 2ND REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: PREVIOUS COMMENTS | | | | PARTIALLY COMPLIED 1. 1. SUBMIT AN ISOMETRIC DRAWING | | THAT CLEARLY SHOWS ALL CUT SECTIONS OF PIPE AND | | CORRESPONDING LENGTHS PER FBC-2014 FUEL GAS, SECS. | | 402.4.1, 402.4.2. AND BTU LOAD OF EACH APPLIANCE. ALSO | | SHOW ALL VALVE DRIP LEGS AND REGULATORS REFER TO THE | | FBC-2014 FUEL GAS SECS. 401.8 THRU 402.6.1 AND TABLES | | 402.4(1) THRU 402.4(37). | | PLEASE PROVIDE THE LENGTH OF EACH CUT SECTION OF PIPE. | | PLEASE SHOW BTU LOAD FOR EACH GAS APPLIANCE.THE NUMBERS | | ON THE ENLARGE BANQUET KITCHEN ISO DO NOT ALL MATCH THE | | GAS EQUIPMENT SCHEDULE. | | | | 2. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. PLEASE PROVIDE | | COMBUSTION AIR CALC FOR THE KITCHEN APPLIANCES. | | | | 3. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | SEC. 502 THRU 505. IN YOUR RESPONSE YOU NOTE VENT | | DETAILS ON SHT P-3.0.08 I COULD NOT LOCATE ANY VENT | | DETAILS ON THAT SHT PLEASE CLARIFY. | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 WE NEED | | THESE TO VERIFY BTU LOADS-IF THEY CAN NOT BE PROVIDED | | FOR PLAN REVIEW PLACE A NOTE ON THE PLAN TO BE ON | | JOBSITE FOR FIRST ROUGH INSPECTION. | | | | NEW COMMENTS: | | | | 1. SHT. P-3.0.08 ON THE GAS ISOMETRIC THE 2ND BRANCH | | UPSTREAM OF THE METER HAS IS LABELED AS MAIN KITCHEN | | SHT. P-1.5.07 WHICH LABELS IT AS THE BANQUET KITCHEN | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 2. PROVIDE AN ENLARGED ISOMETRIC FOR RMAIN KITCHEN. PER | | WPB AMEND TO FBC 107.2.1 | | | | 3. PLEASE LABEL THE BRANCHES ON THE MAIN ISOMETRIC | | DRAWING TO MATCH THE PIPING ON THE ENLARGED ISOMETRIC | | DRAWINGS. PER WPB AMEND TO FBC 107.2.1 | | | | 4. WHAT IS THE 3/4" BRANCH WITH THE NOTE FIX TAG PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 5. WHAT IS THE 2" AT THE UPSTREAM END OF THE ISOMETRIC | | WITH THE TAG XXXMBH/L.F.=XX' PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | | | 6. ON THE ENLARGED ISOMETRIC DRAWING PLEASE SHOW THE | | PRESSURE REGULATORS AND THE VALVES ALSO SHOW THE LENGTH | | AND SIZE OF THE PIPING BETWEEN THE REGULATOR AND THE | | APPLIANCE. PER WPB AMEND TO FBC 107.2.1 | | | | 7. SHT. A-1.4.01A IT IS SHOWING A VENT FREE GAS FIRE | | PLACE UNVENTED GAS APPLIANCES ARE PROHIBITED IN | | ASSEMBLY OCCUPANCY'S. PER FBC FG 621.4 | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-04-21 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-21 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-04-21 |
Time |
11:16 |
Sent To |
|
|
Notes |
2017-04-21 11:26:57 | | | | | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: | | | | 1. 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS | | ALL CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. AND BTU LOAD | | OF EACH APPLIANCE. ALSO SHOW ALL VALVE DRIP LEGS AND | | REGULATORS REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | 2. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | 3. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | SEC. 502 THRU 505. | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | 5. SHT. P-3.0.08 ON NOTE FOR THE SIZING TABLES IT | | REFERRANCES 2010 FBC WE ARE UNDER 2014 5TH EDITION | | CLARIFY. WPB AMEND TO FBC 107.2.1 | | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2018-12-12 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-12-12 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-12-06 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-11-14 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-10-11 |
Time |
09:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-10-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-10-01 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-08-06 |
Time |
12:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-06-07 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-06-07 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-04-17 |
Time |
08:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-05-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-05-04 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-03-17 |
Time |
15:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-11-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-11-06 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-11-06 |
Time |
10:27 |
Sent To |
|
|
Notes |
2018-11-06 10:27:34 | MU2017-15390 | | $166,344.24 PAID | | REVIEWED UNDER 18090472 (STRUCTURE REVISION) |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-04-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-17 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-17 |
Time |
15:57 |
Sent To |
|
|
Notes |
2017-04-17 16:00:12 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT PROVIDED. | | CONTACT 561-233-5025 FOR MORE INFORMATION | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-11-13 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-11-06 |
Time |
10:45 |
Sent To |
|
|
Notes |
2018-11-13 12:47:27 | MECHANICAL PROVISOS: | | | | 1) SEPARATE PERMITS ARE REQUIRED FOR THE KITCHEN | | EXHAUST HOODS, KITCHEN FIRE SUPPRESSION SYSTEMS, AND | | WALKIN COOLERS AND FREEZERS. | | | | 2) INCLUDED WITH THE KITCHEN EXHAUST HOOD DRAWINGS | | SHALL BE: A) INSTALLATION DETAILS FOR THE MAKEUP AIR | | AND EXHAUST FANS AND DUCTS INCLUDING HOW THE ALL | | COMPONENTS WILL BE SUPPORTED INSIDE THE ROOF STRUCTURE. | | B) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | INSTRUCTIONS FOR THE EXHAUST DUCT FIREWRAPPING. C) | | CLEARANCE DISTANCE MEASUREMENTS FOR THE GREASE EXHAUST | | TERMINATION TO VERIFY COMPLIANCE WITH REQUIRED | | CLEARANCES TO PARTS OF THE BUILDING- SECTION | | 506.3.13.3. D) VERIFICATION THAT THE TEMPORATURE OF THE | | MAKEUP AIR DOES NOT EXCEED 10 DEGREES OF THE AIR | | TEMPERATURE IN THE KITCHEN- SECTION 508.1.1. | | | | 3) DEFERRED SUBMITTALS: | | | | A) WIND LOAD ENGINEERING FOR INSTALLATION OF THE | | CHILLERS, PUMPS, AND OTHER ALL EXTERIOR MECHANICAL | | EQUIPMENT. | | B) MIAMI-DADE AND/OR FLORIDA PRODUCT APPROVALS FOR THE | | EXHAUST AND OUTDOOR AIR LOUVERS, INCLUDING | | MANUFACTURER'S SPECIFICATIONS. | | C) FIRE DAMPERS | | D) MOTORIZED DAMPERS. | | E) DUCT SMOKE DETECTORS. | | F) CHILLED WATER PIPING SPECIFICATIONS AND PIIPE | | INSULATIONS. | | G) FLAMEBAR DUCT INSTALLATION DETAILS. | | H) COMMISSSIONING REPORT AND ACKNOWLEDGEMENT LETTER | | FROM BUILDING OWNERSHIP. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2018-09-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-09-07 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-09-07 |
Time |
11:03 |
Sent To |
|
|
Notes |
2018-09-07 11:32:54 | 3RD REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | CODES | | PERMIT #17020796 | | 9/7/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE MATCH THE GUEST ROOM FC SYSTEM | | IDENTIFICATIONS ON THE AC AND ENERGY CALCULATIONS, AND | | THE SCHEDULE ON SHEET M-0.0.02. EACH DOCUMENT | | IDENTIFIES THEM DIFFERENTLY WHICH MAKES OT DIFFICULT TO | | REVIEW FOR COMPLIANCE. IT APPEARS THAT MANY OF THE | | SYSTEMS AS THEY ARE SHOWN IN THE CALCULATIONS ARE BEING | | GROUPED TOGETHER BUT THERE IS NO EXPALNATION OF HOW | | THEY ARE BEING GROUPED- PLEASE CLARIFY. | | | | 2) THE PREVIOUSLY REQUESTED COMBUSTION AIR CALCULATIONS | | FOR THE GAS-FIRED COOKING APPLIANCES WERE NOT PROVIDED. | | | | 3) SHEET M-1.3.01B: THE VENTILATION CA;LCULATION FOR | | THE WOMEN'S LOCKER ROOM IS INCORRECTLY LISTED AT 170 | | CFMS , HOWEVER 204 CFMS ARE REQUIRED. | | | | 4) M-1.3.01B & M-1.4.01: IT APPEARS THAT RECIRCULATION | | OF THE AIR FROM THE MANI/PEDI ROOM IS BEING | | RECIRCULATED TO OTHER ROOMS AND SPACES VIA THE RETURN | | TRANSFER FROM THE ROOM INTO THE PLENUM WHICH IS | | PROHIBITED PER TABLE 403.3 FOOTNOTE B. | | | | 5) M-1.3.01B & M-1.4.01: THE MANI/PEDI PLAN DOES NOT | | INDICATE THAT SOURCE CAPTURE SYSTEMS ARE TO BE | | INSTALLED AT EACH MANICURE TABLE AND PEDICURE CHAIR- | | TABLE 403.3 FOOTNOTE | | | | 6) M-1.3.01B: VENTILATION IS REQUIRED FOR THE FIRE PUMP | | ROOM- SECTIONS 4.12.6 & 11.3.2.1 NFPA 20. | | | | 7) M-1.3.01B: FIRE DAMPERS MISSING AT: A) 20X14 SUPPLY | | DUCT PENETRATING THE BOH CORRIDOR WALL. B) THE 30X14 | | SUPPLY AND RETURN DUCTS PENETRATING MECH RM 1205 WALLS- | | SECTION 607.5.2. | | | | 8) PROVIDE AN AC CONDENSATE PIPING PLAN AND RISER | | DRAWING- SECTION 307. | | | | 9) PROVIDE UL APPROVED FIRESTOPPING SYSTEMS FOR THE | | CHILLED WATER PIPING AND CONDENSATE PIPING. | | | | 10) REFER TO SECTION 3004.1 FBC-14 BUILDING AND | | INDICATE HOW THE ELEVATOR HOISTWAYS ARE BEING VENTED. | | | | 11) REFER TO SECTIONS C408.1 & C408.2 FBC-14 ENERGY | | CONSERVATION: COMMISSIONING OF THE MECHANICAL AND | | ELECTRICAL POWER AND LIGHTING SYSTEMS IS REQUIRED. | | | | C408.2 MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION | | REQUIREMENTS. | | PRIOR TO PASSING THE FINAL MECHANICAL INSPECTION, THE | | REGISTERED DESIGN PROFESSIONAL SHALL PROVIDE EVIDENCE | | OF MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION IN | | ACCORDANCE THE PROVISIONS OF THIS SECTION. | | | | CONSTRUCTION DOCUMENT NOTES SHALL CLEARLY INDICATE | | PROVISIONS FOR COMMISSIONING AND COMPLETION | | REQUIREMENTS IN ACCORDANCE WITH THIS SECTION AND ARE | | PERMITTED TO REFER TO SPECIFICATIONS FOR FURTHER | | REQUIREMENTS. COPIES OF ALL DOCUMENTATION SHALL BE | | GIVEN TO THE OWNER AND MADE AVAILABLE TO THE CODE | | OFFICIAL UPON REQUEST IN ACCORDANCE WITH SECTIONS | | C408.2.4 AND C408.2.5. | | | | | | ADVISORIES: | | | | 1) SEPARATE PERMITS ARE REQUIRED FOR THE KITCHEN | | EXHAUST HOODS, KITCHEN FIRE SUPPRESSION SYSTEMS, WALKIN | | COOLERS AND FREEZERS, FIRE ALARM, FIRE SPRINKLER. | | | | 2) INCLUDED WIH THE KITCHEN EXHAUST HOOD DRAWINGS SHALL | | BE: A) INSTALLATION DETAILS FOR THE MAKEUP AIR AND | | EXHAUST FANS AND DUCTS INCLUDING HOW THE ALL COMPONENTS | | WILL BE SUPPORTED INSIDE THE ROOF STRUCTURE. B) | | MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | INSTRUCTIONS FOR THE EXHAUST DUCT FIREWRAPPING. C) | | CLEARANCE DISTANCE MEASUREMENTS FOR THE GREASE EXHAUST | | TERMINATION TO VERIFY COMPLIANCE WITH REQUIRED | | CLEARANCES TO PARTS OF THE BUILDING- SECTION | | 506.3.13.3. D) VERIFICATION THAT THE TEMPORATURE OF THE | | MAKEUP AIR DOES NOT EXCEED 10 DEGREES OF THE AIR | | TEMPERATURE IN THE KITCHEN- SECTION 508.1.1. | | | | 3) DEFERRED SUBMITTALS: | | | | A) WIND LOAD ENGINEERING FOR INSTALLATION OF THE | | CHILLERS, PUMPS, AND OTHER ALL EXTERIOR MECHANICAL | | EQUIPMENT. | | B) MIAMI-DADE AND/OR FLORIDA PRODUCT APPROVALS FOR THE | | EXHAUST AND OUTDOOR AIR LOUVERS, INCLUDING | | MANUFACTURER'S SPECIFICATIONS. | | C) FIRE DAMPERS | | D) MOTORIZED DAMPERS. | | E) DUCT SMOKE DETECTORS. | | F) CHILLED WATER PIPING SPECIFICATIONS AND PIIPE | | INSULATIONS. | | G) FLAMEBAR DUCT INSTALLATION DETAILS. | | H) COMMISSSIONING REPORT AND ACKNOWLEDGEMENT LETTER | | FROM BUILDING OWNERSHIP. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-05-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-05-08 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-05-03 |
Time |
15:30 |
Sent To |
|
|
Notes |
2018-05-08 17:07:22 | 2ND REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | CODES | | PERMIT #17020796 | | 5/8/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | THIS FOLLOW-UP REVIEW IS BASED ON THE RESUBMITTED | | PLANS, DOCUMENTS, AND RESPONSE NARRATIVE BY THE | | ENGINEER OF RECORD. ALL 1ST REVIEW COMMENTS NOT | | COMPLETELY RESOLVED ARE LISTED BELOW IN THEIR ORIGINAL | | NUMERICAL ORDER. | | | | | | 1) THE FOLLOWING LIST OF NEW UPLOADED PLAN SHEETS NEED | | TO BE ELECTRONICALLY SIGNED AND SEALED: M-1.3.01C, | | M-1.3.03A, M4.0.00, M-5.0.01, M-5.0.02, M-5.0.03, | | M-5.0.05 | | | | 1A) THE REVISED ENERGY CALCULATIONS ARE INDICATING | | CAPACITIES FOR AHU 3 & 5, AND OA-1 THAT DON'T MATCH THE | | SCHEDULE ON SHEET M-0.0.02. B) THE FC TYPICAL-345 | | IDENTIFICATION AND THE NO. OF UNITS SHOWN IN THE ENERGY | | CALCULATIONS DOES NOT MATCH THE FC SCHEDULE- SHEET | | M-0.0.02. C) THE ENERGY CALCULATIONS DO NOT PROVIDE ANY | | HEATING COMPLIANCE DATA. | | | | 4) THE 19.8 BTUH FC SYSTEMS SELECTED FOR THE GUEST | | ROOMS ARE OVERSIZED PER THE SUBMITTED AC CALCULATIONS | | WHICH SHOW ALL THE SYSTEMS CALCULATED AT 1-TON OR LESS- | | SECTION C403.2.2 FBC-14 ENERGY CONSERVATION. | | | | 10) THE REQUESTED ENLARGED FOOD SERVICE DRAWINGS AND | | EQUIPMENT SCHEDULE NOT PROVIDED. PLEASE NOTE THE | | SUBMITTAL PACKAGE FROM CHENEY INCLUDES A WOOD-FIRED | | GRILL WHICH MUST BE UL 2162 LISTED AND LABELED PER | | SECTION 917.1. | | | | 11) THE REQUESTED COMBUSTION AIR CALCULATIONS FOR THE | | GAS-FIRED COOKING APPLIANCES AND WATER HEATERS WERE NOT | | PROVIDED. PLEASE SEE SECTION 304 FBC-14 FUEL GAS AND | | COMPLY. | | | | 14) THE REQUESTED FLEX DUCT SIZES WERE NOT PROVIDED. | | | | 16) THE REQUESTED DUCT SMOKE DETECTOR SYMBOLS TO BE | | PLACED ON THE PLAN WERE NOT PROVIDED. | | | | 17) THE REQUESTED EXHAUST VENTILATION AND AIR BALANCE | | CALCULATIONS FOR THE LOCKER ROOMS AND THE MANI-PEDI | | ROOM WERE NOT PROVIDED. | | | | A) THE NEW TOILET EXHAUST RISER FOR THE GUEST ROOMS ON | | SHEET M-3.0.002 INDICATES AN ERV WILL BE REQUIRED FOR | | THE SYSTEMS- SEE TABLE C403.2.6 FBC-14 ENERGY | | CONSERVATION AND REVISE THE PLANS. | | | | B) SPORTS LOCKER ROOMS ARE CALCULATED AT 0.50 CFMS PER | | SQ. FT. PER TABLE 403.3. ASHRAE 62.1-10 IS A STANDARD | | HOWEVER, PER FLORIDA STATURE 553, THE PLANS SHALL BE | | DESIGNED IN ACCORDANCE WITH THE FBC-14 MECHANICAL CODE. | | PLEASE REVISE THE CALCULATIONS AND EXHAUST SYSTEMS, AND | | INCLUDE AN AIR BALANCE CALCULATION THAT INCLUDES THE | | MAKEUP AIR. | | | | C) THE REQUESTED ENLARGED DRAWINGS FOR THE MANI-PEDI | | HVAC SYSTEM WAS NOT PROVIDED. PLEASE SEE TABLE 403.3 | | AND FOOTNOTES B AND H. RECIRCULATION OF AIR FROM THE | | SPACE IS PROHIBITED AND A SOURCE CAPTURE SYSTEM MUST BE | | INSTALLED AT EACH MANICURE AND PEDICURE STATION. REVISE | | THE DRAWINGS, AND EXHAUST AND AIR BALANCE CALCULATIONS. | | THE CURRENT PLAN APPEARS TO INDICATE | | | | MAKEUP AIR FOR EXHAUST BEING TRANSFERRED FROM THE | | CORRIDOR. THIS IS NOT PERMITTED BECAUSE THE CORRIDOR IS | | NOT BEING DIRECTLY SUPPLIED WITH OUTDOOR AIR AT A RATE | | HIGHER THAN THE RATE OF MAKEUP AIR TAKEN FROM THE | | CORRIDOR- SECTION 601.2(1). THIS RESTRICTION ALSO | | APPLIES TO THE TRANSFERS AT THE ADJACENT LOCKER ROOMS | | AND RESTROOMS. | | | | D) SHEETS M1.301A & M1-301B: THERE ARE TRANSFER DUCTS | | SHOWN INTO THE CORRIDORS FROM ROOMS 1112, 1112B, 1113, | | AND 1114. PLEASE CLARIFY IF THESE ARE TRANSFERS INTO AN | | ABOVE CEILING PLENUM, OR DIRECTLY INTO THE CORRIDORS. | | INDICATE WITH DOTTED LINES THE AREAS OF ABOVE-CEILING | | PLENUM SPACES AND IDENTIFY THEM USING KEYED NOTE #1. | | PLEASE NOTE THAT CORRIDORS CANNOT BE USED AS | | | | RETURN DUCTS PER SECTION 601.2, HOWEVER THE CEILINGS | | ABOVE ARE PERMITTED UNDER SECTION 601.2.1. | | | | 20) PROVIDE MIAMI-DADE NOA'S OR FLORIDA PRODUCT | | APPROVALS FOR THE EXHAUST AND O/A INTAKE LOUVERS. CAN | | BE A DEFERRED SUBMITTAL. PLEASE PROVIDE A LIST OF ALL | | DEFERRED SUBMITTALS ON THE PLANS OR IN THE DOCUMENTS. | | | | 25) ACKNOWLEDGED THAN WIND LOAD ENGINEERING FOR | | INSTALLATION OF THE CHILLER, PUMPS ETC. WILL BE A | | DEFERRED SUBMITTAL. | | | | 26) LABEL THE GRAVITY DAMPERS AT THE GUEST ROOM FAN | | COIL UNITS, AND PROVIDE A SUBMITTAL FOR THE FAN-COIL | | UNITS. CAN BE DEFERRED. | | | | 29) ACKNOWLEDGED THAT THE TOILET EXHAUST DUCTWORK WILL | | BE FLAMEBAR. PLEASE SUBMIT MANUFACTURER'S | | SPECIFICATIONS AND INSTALLATION DETAILS REVIEWED AND | | STAMPED BY THE EOR. CAN BE A DEFERRED SUBMITTAL. | | | | 32 & 33) ACKNOWLEDGED THAT THE DISCHARGE LOCATIONS FOR | | THE KITCHEN EXHAUST FANS WILL BE IN COMPLIANCE WITH THE | | CLEARANCES REQUIRED UNDER SECTIONS 506.13.1 & | | 506.3.13.3, AND THE PLANS AND DETAILS WILL BE REVIEWED | | UNDER SEPARATE PERMIT. A) SHEETS M1.3.01A & B, M1.3.02A | | & B, M1.3.03A & B, AND M1.3.04A & B: THE GREASE EXHAUST | | DUCTS FROM THE KITCHEN HOODS ARE NOT | | | | PERMITTED TO BE LOCATED IN THE SAME SHAFTS- SEE SECTION | | 506.3.11. PLEASE NOTE THAT THE REQUIRED SHAFT FOR HOOD | | 4 & 5 GREASE DUCTS IS NOT SHOWN ON THE SECOND FLOOR | | MECHANICAL PLAN SHEET M-1.3.02A. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-04-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-04-05 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-04-03 |
Time |
11:55 |
Sent To |
|
|
Notes |
2017-04-05 12:58:38 | 1ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | CODES | | PERMIT #17020796 | | 4/3/17 | | | | 1) THE UPLOADED DIGITAL MECHANICAL PLANS, ENERGY AND AC | | CALCULATIONS REQUIRE ELECTRONIC SEALS AND SIGNATURES BY | | THE ENGINEER OF RECORD IN ACCORDANCE WITH SECTION | | 471.025 FLORIDA STATUTES, AND SECTION 61G15-23.005 | | FLORIDA ADMINISTRATIVE CODE. | | | | 2) ADVISORY: SEPARATE PERMITS AND PLANS ARE REQUIRED | | FOR THE KITCHEN HOOD EXHAUST AND FIRE SUPPRESSION | | SYSTEMS, AND THE WALK-IN COOLERS AND FREEZERS. | | REGARDING THE KITCHEN HOODS PLEASE SEE SECTION 508.1.1 | | FBC-14 MECHANICAL- MAKEUP AIR TEMPERATURE. THE CURRENT | | PLAN IS NOT IN COMPLIANCE. | | | | 3) THE AC COOLING AND HEATING CALCULATIONS ARE | | INCORRECTLY SPECIFYING MIAMI AS THE LOCATION AND ORIGIN | | OF DESIGN DATA FOR THE PROJECT. | | | | 4) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | GUEST ROOMS AND ALL OTHER HABITABLE ROOMS SERVED BY THE | | FAN COIL UNITS- SECTION C403.2.1 FBC-14 ENERGY | | CONSERVATION. | | | | 5) REGARDING THE UPLOADED AC CALCULATIONS PLEASE NOTE | | THE TOTAL COOLING CAPACITIES FOR AHU?S 3 & 5 SHOWN IN | | THE SCHEDULE ON SHEET M-0.0.02- (68.6 & 63.3 MBH) DO | | NOT MATCH THE CALCULATED LOADS OF (169.3 & 127 MBH). | | | | 6) REFER TO TABLE C403.2.3(7) FBC-14 ENERGY | | CONSERVATION: IT APPEARS THE EFFICIENCY CRITERIA FOR | | THE CHILLER SHOWN ON THE ENERGYGAUGE COMPLIANCE | | SUBMITTAL IS INCORRECT FOR AN AIR-COOLED CHILLER. | | | | 7) SHEET M-0.0.0.1: PLEASE UPDATE THE SMACNA SECOND | | EDITION REFERENCE AND PROVIDE DUCT HANGER TABLES IN | | COMPLIANCE WITH THE 2005 THIRD EDITION. | | | | 8) SHEET M-0.0.03: PLEASE UPDATE THE ASHRAE 62.1-2004 | | REFERENCE AND PROVIDE VENTILATION RATES IN ACCORDANCE | | WITH THE CURRENT 2010 STANDARD IN EFFECT. PLEASE SEE | | TABLE 6-1 ASHRAE 62.1-2010, OR TABLE 403.3 FBC-14 | | MECHANICAL AND PROVIDE THE VENTILATION RATES FOR THE | | GUESTROOMS. | | | | 9) PROVIDE CONDENSATE DISPOSAL PLANS FOR THE AIR | | HANDLERS AND FAN COIL UNITS- SECTION 307. | | | | 10) PROVIDE ENLARGED KITCHEN AND FOOD SERVICE DRAWINGS. | | | | 11) INDICATE HOW COMBUSTION AIR IS BEING PROVIDED TO | | THE GAS-FIRE COOKING APPLIANCES AND WATER HEATERS AND | | PROVIDE CALCULATIONS- REFER TO SECTION 304 FBC-14 FUEL | | GAS. PROVIDE WATER HEATER VENTING DIAGRAMS THAT | | INDICATE THE TYPE AND SIZE OF THE VENTS, TOTAL VENT | | RUNS AND TERMINATION LOCATIONS. | | | | 12) M-1.3.01A: LABEL THE EXHAUST RISER LOCATIONS FOR | | KEF-4 & 5. | | | | 13) M-1.3.01A: MISSING FIRE DAMPERS- A) 8X8 DUCT | | PENETRATING THE UNISEX RESTROOM/BOARDROOM #1 WALL. B) | | 30X14 DUCT AT CORRIDOR 1110/BANQUET PANTRY WALL. | | | | 14) M-1.3.01A & B: PROVIDE THE FLEX DUCT SIZES ON THE | | PLAN. | | | | 15) M-1.3.01A & B: SHOW THE LOCATIONS OF ALL REQUIRED | | ACCESS PANELS FOR ALL FAN COIL UNITS AND VAV BOXES | | LOCATED ABOVE HARD CEILINGS- SECTION 306.1. | | | | 16) M-1.3.01A & B: PROVIDE DUCT SMOKE DETECTORS IN THE | | RETURN AIR SYSTEMS OF THE AHU'S- SECTION 606.2.1. | | | | 17) M-1.3.01A & B: PROVIDE EXHAUST VENTILATION | | CALCULATIONS FOR THE KITCHENS, THE TOILET AND | | BATHROOMS, THE LOCKER ROOMS, AND THE MANICURE/PEDICURE | | SPA- SEE TABLE 403.3. PROVIDE ENLARGED DRAWINGS OF THE | | EXHAUST SYSTEMS THAT INDICATE THE TYPES AND SIZES OF | | EXHAUST DUCTS, TOTAL EXHSAUST VENT RUNS, AND INLET AND | | OUTLET LOCATIONS- SEE TABLE 403.3 FOOTNOTE B AND H. | | | | 18) M-1.3.01A & B: PROVIDE AIR BALANCE CALCULATIONS. | | | | 19) M-1.3.01A & B: DEMAND CONTROLLED VENTILATION IS | | REQUIRED FOR THE DINING/LOUNGE, FITNESS, AND BALLROOMS | | 1 & 2- REFER TO SECTION C403.2.5.1 AND PROVIDE A MEANS | | OF COMPLIANCE ON THE PLAN. | | | | 20) M-1.3.01A & B: THE LOCATIONS AND REQUIRED CLEARANCE | | DISTANCES FOR O/A INTAKES AND EXHAUST OUTLETS SHALL BE | | IN COMPLIANCE WITH SECTIONS 401.4 AND 501.3.1. PLEASE | | PLACE NOTES OR SHOW CLEARANCE DISTANCE MEASUREMENTS ON | | THE PLAN TO VERIFY COMPLIANCE. | | | | 21) M-1.3.01A: CLARIFY HOW O/A IS BEING PROVIDED TO | | AHU-5. IT APPEARS THE INLET AT MECHANICAL 11120 IS | | LABELED MAKEUP AIR. | | | | 22) M-1.3.01B: MISSING FIRE DAMPERS FOR DUCTS | | PENETRATING A) CORRIDOR 1135/SECURITY-RECEIVING WALL. | | B) DUCT PENETRATING THE CORRIDOR 1157/F.O. ADMIN WALL. | | | | 23) M-1.3.01B: LABEL THE O/A INLET FOR AHU-3. | | | | 24) M-1.3.01C: PROVIDE AN ENLARGED DETAIL SHOWING THE | | UNDERGROUND CHILLED WATER PIPING RUNS FROM THE CHILLER | | AND PUMPS ETC. INTO THE BUILDING. INDICATE THE TYPE AND | | SIZE OF PIPING, TYPE AND THICKNESS OF INSULATION. | | | | 25) M-1.3.01C: WIND LOAD ENGINEERING IS REQUIRED FOR | | ANCHORING THE CHILLER, THE PUMPS, AIR SEPARATOR, | | EXPANSION TANK, AND THE CHILLED WATER PIPING- SEE | | SECTION 301.15 . PLEASE SEE SECTION 1609 FBC-14 | | BUILDING AND PROVIDE DETAILS AND DESIGN CRITERIA. | | | | 26) M-1.3.02A, 2B, 3A, 3B, 4A, 4B: LABEL THE O/A | | INTAKES FOR THE FC UNITS, AND PROVIDE AUTOMATIC SHUTOFF | | DAMPERS FOR THE O/A DUCTS- SECTION C403.2.4.4 FBC-14 | | ENERGY CONSERVATION. | | | | 27) M-1.5.02, 03, 04, 05: PROVIDE RETURN AIR FOR THE FC | | UNITS IN THE GUESTROOMS, AND PROVIDE AN ENLARGED DETAIL | | SHOWING HOW ACCESS WILL BE PROVIDED FOR MAINTENANCE AND | | REPLACEMENT OF THE UNITS- SECTION 306.1. | | | | 28) M-3.0.00: PROVIDE EITHER NOTES OR DETAILS ON THE | | RISER PLAN INDICATING THE TYPE OF O/A DUCTWORK, | | LOCATIONS OF FIRE DAMPERS ETC. | | | | 29) PLEASE PROVIDE TOILET EXHAUST RISER DRAWINGS | | INCLUDING THE TYPES AND SIZES OF EXHAUST DUCTS, | | VERTICAL RUN LENGTHS OF SUB-DUCTS, AND EXHAUST CFMS. | | | | 30) M-1.3.04A, 4B, 5A & 5B: PROVIDE WIND LOAD | | ENGINEERING FOR TIE-DOWN OF THE ROOFTOP DUCTWORK, THE | | TOILET EXHAUST OUTLETS, AND THE O/A INTAKE HOODS. | | PLEASE NOTE THAT FLORIDA PRODUCT APPROVALS AND/OR | | MIAMI-DADE NOA'S ARE REQUIRED FOR ANY MANUFACTURED | | EXTERIOR MECHANICAL EQUIPMENT SUPPORTS OR STANDS. | | | | 31) M-1.3.05A, 5B: IT APPEARS THAT FLAMEBAR DUCTWORK IS | | MISSPELLED AS BAMEBAR- PLEASE CORRECT. | | | | 32) M-1.3.04B: THE LOCATION OF THE EXHAUST OUTLETS FOR | | KEF- 1, 2 & 3 APPEAR TO BE NON-COMPLIANT WITH SECTION | | 506.13.3 WHICH REQUIRES A 10' HORIZONTAL CLEARANCE | | DISTANCE FROM THE OUTLETS TO PARTS OF THE SAME OR | | CONTIGUOUS BUILDING. PLEASE SEE THE EXCEPTION UNDER | | THIS SECTION FOR FURTHER INFORMATION. | | | | 33) M-1.3.05A: THE LOCATIONS OF THE EXHAUST OUTLETS FOR | | KEF-4 & 5 APPEAR TO BE NON-COMPLIANT WITH SECTIONS | | 506.3.13.1 & 506.3.13.3. PLEASE PROVIDE CLEARANCE | | DISTANCE MEASUREMENTS. PLEASE NOTE THAT ADDITIONAL | | COMMENTS REGARDING THE KITCHEN COOKING EXHAUST SYSTEMS | | MAY OCCUR AFTER COMPLETE PLANS AND SPECIFICATIONS ARE | | SUBMITTED FOR REVIEW UNDER SEPARATE PERMIT. | | | | 34) INDICATE HOW ACCESS IS BEING PROVIDED FOR | | SERVICEABLE MECHANICAL EQUIPMENT LOCATED ON THE | | BUILDING ROOFTOPS (I.E. EF-4-1, EF-5-1, KEF-4 & 5)- | | SECTION 306.5. ADDITIONALLY PLEASE NOTE THAT ACCESS | | SHALL NOT REQUIRE WALKING ON ROOFS WITH A SLOPE GREATER | | THAN 4 UNITS VERTICAL IN 12 HORIZONTAL. | | | | 35) PROVIDE FL. PRODUCT APPROVALS AND/OR MIAMI-DADE | | NOA'S FOR THE O/A INTAKE AND EXHAUST OUTLET LOUVERS. | | | | 36) PROVIDE APPROVED PRODUCT SUBMITTAL DOCUMENTS FOR | | THE FLAMEBAR DUCT, THE MOTORIZED DAMPERS, AND THE CO2 | | SENSORS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2018-11-30 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-11-14 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-11-30 |
Time |
14:29 |
Sent To |
|
|
Notes |
2018-11-14 08:45:11 | PLUMBING PROVISOO: | | | | 1. SHT. P-3.0.01 IN PROJECT DOX IS LABELED RISER | | DIAGRAM GRAVITY 2-4 FL NORTH THE PLAN SHEET IS THE | | RISER DIAGRAM 1ST FL SOUTH PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | 2. SHT. P- 3.0.03 IN PROJECT DOX IS LABELED RISER | | DIAGRAM GRAVITY 2-4 FL SOUTH THE PLAN SHEET IT PLUMBING | | RISER PRESSURE 1ST FL SOUTH PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | 3. SHT. P-3.0.04 IN PROJECT DOX IS LABELED RISER | | DIAGRAM PRESSURE 1ST FL NORTH THE PLAN SHEET IS THE | | SOUTH SIDE RISERS PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | 4. SHT P-1.3.01B LABEL THE SOIL STACKS IN THESE ROOMS | | TO MATCH SANITARY ISOMETRIC SOME ARE NOT LABELED SOME | | ARE LABELED AS WCO THE FOLLOWING ROOMS MAIN ELECTRICAL | | 1151, NEXT TO CORRIDOR 1138, IN FRONT OF LIQUOR ROOM | | 1129D, 1137, 1221 TOILET STALL, 223 TRIPLE SINK. . PER | | WPB AMEND TO FBC 107.2.1 | | 5. SHT. P-3.0.02A ON THE LEFT SIDE OF THE ISOMETRIC | | THERE IS A SOIL STACK LABELED S30 I COULD NOT FIND THAT | | RISER ON THE FLOOR PLAN PLEASE CLARIFY. PER WPB AMEND | | TO FBC 107.2.1 | | 6. SHTS. P-3.0.01 AND P-3.0.02 ARE THE SAME DRAWING | | JUST DIFFERENT VERSIONS BOTH ISOMETRICS HAVE SOIL | | STACKS THAT ARE NOT LABELED AND FIXTURES THAT ARE NOT | | LABELED THESE ISSUES SHALL BE CLEARED UP BEFORE A | | PLUMBING PERMIT CAN BE ISSUED. | | 7. SHTS. P-1.3.02A AND B THESE SHEETS WERE JUST | | UPLOADED TO SHOW THE CONDENSATE DRAIN IT APPEARS THAT | | THEY ARE SHOWING THE UNDERGROUND PIPING ON THE SECOND | | FLOOR IT SHOULD BE SHOWN ON THE 1ST FLOOR. PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | 8. SHT. P-3.0.08 THE CONDENSATE ISOMETRIC DRAWING NORTH | | SIDE IS LABELED AS THE NATURAL GAS RISER . PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2018-09-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-09-11 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-09-04 |
Time |
12:14 |
Sent To |
|
|
Notes |
2018-09-11 10:30:43 | FBC 2014 5TH EDITION | | | | 3RD REVIEW PLUMBING COMMENTS: | | | | 1. PREVIOUS COMMENT #12 PARTIALLY COMPLIED PLEASE | | CORRECT THE FOLLOWING. PER WPB AMEND TO FBC 107.2.1 | | A) SHT. P-1.3.01A I CAN NOT FIND THE SOIL STACK FOR S8, | | S3, S2. | | B) SHT. P-3.0.00 SOIL STACK N6, N7, N8 ARE NOT LABELED | | TO MATCH THE ENLARGED ISOMETRICS S# | | C) SOIL STACK N6 APPEARS TO BE LABELED WCO ON SHT. | | P-1.3.01A | | D) SHT. P-1.3.01A PLEASE LABEL THE SOIL STACKS BETWEEN | | GRID LINES 16 +14 TO MATCH THE ISOMETRICS. | | E) SHT. P-3.0.00 PLEASE LABEL ALL STACKS IN THE AREA OF | | SOIL STACKS N7 + N8 | | | | 2. SHT. P-3.0.01 AND SHT. P-3.0.02 THESE ISOMETRIC | | DRAWINGS SEEM TO BE INCOMPLETE PLEASE LABEL THE ALL | | FIXTURES , LABEL THE SANITARY STACKS DOWN, SOME OF THE | | SS DON'T SHOW ANY BRANCHES SUCH AS S5,7,8,9. THERE ARE | | PIPES SHOWN THAT DON'T CONNECT AND ARE NOT LABELED IT | | SEEMS THAT SOME OF THE FIXTURES WERE LABELED FCO PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 3. SHT. P3.0.02 THIS ISOMETRIC DRAWING IS TO CONGESTED | | TO DETERMINE CODE COMPLIANCE PLEASE EXPAND AND CLOUD | | AREAS AND LABEL TO COINCIDE WITH ENLARGED DRAWINGS. PER | | WPB AMEND TO FBC 107.2.1 | | | | 4. SHT. P-1.5.05 PLEASE LABEL ALL PLUMBING FIXTURES ON | | THE WATER AND SANITARY ISOMETRICS.. PER WPB AMEND TO | | FBC 107.2.1 | | | | 5. SHT. P 3.0.05 THE ISOMETRIC APPEARS TO BE INCOMPLETE | | PLEASE LABEL THE FIXTURE, BRANCHES AND NOTE WHERE | | PIPING CONTINUES. PER WPB AMEND TO FBC 107.2.1 | | | | 6. SHT. P-1.3.01B PLEASE LABEL THE SOIL STACKS TO MATCH | | THE ISOMETRICS AND LABEL THE GREASE, SANITARY LINES. | | PER WPB AMEND TO FBC 107.2.1 | | | | 7. PREVIOUS COMMENT #3 SHT. P-1.5.10 THE ENLARGED | | SANITARY ISOMETRIC IS MISSING PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-05-08 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-05-08 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-05-04 |
Time |
12:22 |
Sent To |
|
|
Notes |
2018-05-08 12:31:12 | 2ND REVIEW | | FBC 2014 5TH EDITION | | PERMIT# 17020796 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | | | !!!! IN ORDER TO TO EXPIDITE AN APPROVAL FOR THIS | | PERMIT I SUGEST A MEETING BE SCHDULED TO GO OVER THE | | PLAN PLEASE CONNTACT ME @ 561-805-6711 !!! | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED SEE | | NEW COMMENTS | | | | 10. PLEASE PROVIDE SLOPE OF PIPE ON RISER DIAGRAMS. PER | | FBC PL 704. | | | | 12. PLEASE LABEL THE STACKS ON THE RISER TO MATCH THE | | FLOOR PLAN, WATER AND SANITARY. PER WPB AMEND TO FBC | | 107.2.1 | | | | 17. SOME OF THE SOIL STACK ARE NOTE SIZED OR LABELED | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 24. SHT. P-3.0.03 AND P-3.0.01 SHOW BRANCH LINES FOR | | EACH UNIT AND SHOW FLOOR LEVEL. PER WPB AMEND TO FBC | | 107.2.1 | | | | NEW COMMENTS: | | | | 1. ALL THE ACCESSIBILITY SHALL COMPLY WITH FLORIDA | | BUILDING CODE ACCESSIBILITY 2014 5TH EDITION PLEASE | | NOTE ON THE PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | 2. SHT. P-3.0.05 THE 1" HOT WATER RECIRCULATION LINE | | DOES NOT SHOW UP ON THIS SHEET PLEASE CLARIFY. PER FBC | | PL 607.2 | | | | 3. SHT. P- 1.5.10 THE SANITARY PIPING DID NOT SHOW UP | | ON THIS SHEET PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | | | 4. SHT. P-3.0.00 AND P-3.0.02 PLEASE SHOW THE SIZE AND | | SLOPE ON THE ISOMETRIC WE NEED THIS TO CHECK SIZING THE | | TABLE THAT WAS PROVIDED DOES NOT SPECIFY THE SLOPE IT | | ONLY GIVES A MINIMUM THE SIZING TABLE FBC PL TABLE | | 710.1(1) USES SPECIFIC SLOPE TO SIZE THE PIPE. PER WPB | | AMEND TO FBC 107.2.1 | | | | 5. SHT. P-1.1.00 THE SOUTH GREASE INTERCEPTOR DID NOT | | SHOW UP ON THE SHEET IT IS ALSO MISSING THE GREASE AND | | SANITARY PIPING PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | | | 6. SHT. P-3.0.02 TWOWAY CLEANOUTS ARE REQUIRED BETWEEN | | EACH INTERCEPTOR PLEASE SHOW ON PLAN. PER WPB AMEND TO | | FBC 107.2.1 | | | | 7. ON THE SANITARY ISOMETRIC DRAWINGS GOING FROM THE | | FIRST FLOOR TO THE 2ND, 3RD, AND 4TH FLOOR SOME OF THE | | ID TAGS ARE NOT MATCHING UP SOME ARE MISSING AND ON THE | | DRAWING FOR THE UPPER FLOOR IT APPEARS THE BRANCHES ARE | | MISSING THESE ISOMETRIC DRAWING ARE TO CONFUSING TO | | DETERMINE CODE COMPLIANCE PLEASE CLARIFY. PER WPB AMEND | | TO FBC 107.2.1 | | | | 8. THE FLOOR PLANS ARE MISSING THE ID TAGS TO MATCH UP | | THE SANITARY STACKS TO THE ISOMETRIC DRAWINGS PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 9. IN YOUR RESPONSE TO COMMENT #21 YOU REFER TO DETAIL | | ON SHT. P-4.0.04 THIS SHEET IS MISSING FROM THIS | | SUBMITTAL PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 10. SHT. P- 1.4.07 PLEASE REMOVE THE GAS ISOMETRIC FROM | | THE WATER ISO IT SHOULD BE ON SHT. P-3.0.08 AND LABEL | | ALL FIXTURE SOME ARE MISSING LABELS. PER WPB AMEND TO | | FBC 107.2.1 | | | | 11. SHT. P-3.0.07 PLEASE LABEL ALL THE FIXTURES AND | | BRANCHES FOR THE UNITS ALSO SHOW THE SIZE ON ALL THE | | PIPING. PER WPB AMEND TO FBC 107.2.1 | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-04-21 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-21 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-04-19 |
Time |
09:42 |
Sent To |
|
|
Notes |
2017-04-21 11:15:07 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. SHT. A1.9.01 PLEASE SHOW CLEAR FLOOR SPACE FOR | | ACCESSIBLE URINAL COMPLYING WITH FBC ACC 605.3 | | 2. PLEASE SHOW COMPLIANCE FOR SEATS, CONTROLS, GRAB | | BARS, CLEAR FLOOR SPACE, SIZES PER FBC ACC 607 TUBS AND | | 608 SHOWERS. | | 3. PROVIDE ELEVATIONS AND CLEAR FLOOR SPACE FOR | | ACCESSIBLE GUEST BATHROOMS. PER FBC ACC 806.2.4 | | 4. SHT. A-1.5.02 DETAILS 3 AND 4 GUESTROOM DOUBLE 6 AND | | 7 SHOW THE SAME ROOM NUMBERS PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | 5. PLEASE PROVIDE ENLARGED FLOW PLANS FOR ACCESSIBLE, | | KING W/SHOWER RM # 3315 AND DOUBLE W/SHOWER RM# 3313 | | PLEASE INCLUDE DIMENSIONS FOR SHOWER. PER WPB AMEND TO | | FBC 107.2.1 | | 6. SHT. A-1.5.02 DETAIL 3 DOUBLE 6 THE LAVATORY TOP IS | | ENCROACHING INTO THE 60? CLEAR FLOOR SPACE OF TOILET. | | PER FBC PL 604.3.1 | | 7. SHT. P-4.0.01 FOR THE FIRE ASSEMBLY?S, PROVIDE | | MANUFACTURE AND STANDARD THEY MEET SUCH AS UL. PER WPB | | AMEND TO FBC 107.2.1 | | 8. PROVIDE TYP. WATER RISER FOR GUEST UNIT BATHROOMS. | | PER WPB AMEND TO FBC 107.3.5.1.3(13) | | 9. A CLEAN OUT IS REQUIRED AT THE BASE OF EACH SOIL OR | | WASTE STACK. PER FBC PL708.3.4 | | 10. PLEASE PROVIDE SLOPE OF PIPE ON RISER DIAGRAMS. PER | | FBC PL 704. | | 11. PROVIDE DFU LOAD ON STACKS AND BUILDING DRAIN. PER | | WPB AMEND TO FBC 107.2.1 | | 12. PLEASE LABEL THE STACKS ON THE RISER TO MATCH THE | | FLOOR PLAN, WATER AND SANITARY. PER WPB AMEND TO FBC | | 107.2.1 | | 13. SHT. P-4.0.00 DETAIL # 2 SHOWS DRAIN FROM SUMP PUMP | | DRAINING TO THE STORM DRAIN IT IS ALSO SHOWN DUMPING | | INTO SANITARY PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | 14. SHT. P-1.1.00 THE GREASE TRAP CALCULATION THAT WERE | | USED ARE FOR ESTABLISHMENTS WITH COMMERCIAL KITCHENS | | THIS APPLICATION SHALL BE FOR RESTAURANTS IT?S A | | DIFFERENT CALCULATION USING NUMBER OF SEATS AND HOURS | | OF OPERATION. PER FBC PL 1003.2 | | 15. LABEL ALL FIXTURES ON RISER DIAGRAMS. PER WPB | | AMEND TO FBC 107.2.1 | | 16. P-3.0.02 THE BRANCH DRAIN FOR THE FLOOR DRAIN AND | | LAVS IN MEN?S BATHROOM #1149 SHALL NOT ROLL UP OVER THE | | 8" BUILDING DRAIN YOU CAN ROLL THE BRANCH DRAIN FOR THE | | WHOLE GAIN BATHROOM UP TO CLEAR THE BUILDING DRAIN MAIN | | TRUNK LINE. PER FBC PL 901.2.1 | | 17. SOME OF THE SOIL STACK ARE NOTE SIZED OR LABELED | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | 18. PLEASE PROVIDE KITCHEN EQUIPMENT PLAN AND SCHEDULE | | FOR #1129, #1118 AND #1119. PER WPB AMEND TO FBC | | 107.2.1 | | 19. PROVIDE PLUMBING FLOOR PLAN WITH THE SOIL STACKS | | LABELED TO MATCH RISER DIAGRAM. FOR FIRST FLOOR. PER | | WPB AMEND TO FBC 107.2.1 | | 20. HORIZONTAL DRY VENTS ARE PROHIBITED BELOW FLOOD | | LEVEL RIM OF FIXTURES I FOUND A FEW IN THE KITCHEN, | | RETAIL COFFEE AND THE BAR ALSO IN THE COUPLE?S SUITE ON | | THE TUB DRAIN. PER FBC PL 905.3/ 905.4 | | 21. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS. PER FBC | | PL 1002.4 | | 22. SHT. P-1.3.01B AND P-1.4.01B SHOWS A SINGLE | | DRINKING FOUNTAIN IN FITNESS AREA, TWO DRINKING | | FOUNTAINS ARE REQUIRED. PER FBC ACC 211.2 | | 23. SHT. P-1.4.01B AND P-3.0.06 WATER PIPING FOR | | DRINKING FOUNTAIN IN FITNESS AREA IS NOT SHOWN PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | 24. SHT. P-3.0.03 AND P-3.0.01 SHOW BRANCH LINES FOR | | EACH UNIT AND SHOW FLOOR LEVEL. PER WPB AMEND TO FBC | | 107.2.1 | | 25. SHT. P-3.0.07 SHOWS UNITS 3309 AND 3314 PROVIDE | | RISER FOR 4TH FLOOR WITH THESE UNITS REMOVED. PER WPB | | AMEND TO FBC 107.2.1 | | 26. PROVIDE WATER RISERS FOR BOTH KITCHENS, BAR, RETAIL | | COFFEE AND SERVICE PER WPB AMEND TO FBC 107.2.1EA. | | 27. SHT. P-4.0.00 THE GAS WATER HEATER DETAIL DOES NOT | | MATCH THE RISER ON SHT. P3.0.07 PLEASE CLARIFY. | | PER WPB AMEND TO FBC 107.2.1 | | 28. SHT. P-4.0.00 THE GAS WATER HEATER DETAIL SHOWS A | | 110 DEG. AND 140 DEG. PIPE BUT THE RISER DOES NOT A MIN | | OF 110 DEG IS REQUIRED IN THE KITCHENS HOW WILL THIS BE | | ACCOMPLISHED PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | 29. SHT. P.3.0.02 THE RISER IS MISSING THE DRAIN FOR | | THE ACCESSIBLE SHOWERS IN THE MEN?S AND WOMEN?S LOCKER | | ROOM PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | 30. PROVIDE THE DIMENSION FOR ALL SHOWERS IN THE LOCKER | | ROOMS. PER WPB AMEND TO FBC 107.2.1 | | 31. ALL PLAN SHEETS SHALL BE DIGITALLY SIGNED BY THE | | DESIGN PROFESSIONAL RESPONSIBLE FOR DRAWING. PER FAC | | 61G1-16.005 | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2017-04-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-24 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-24 |
Time |
07:21 |
Sent To |
|
|
Notes |
2017-04-24 07:23:22 | ROOF INFORMATION NOT SUBMITTED | | PRIOR TO INSTALLATION, A ROOF PERMIT IS REQUIRED. | | PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD ARE TO | | BE SUBMITTED. ENGINEERING, IF APPLICABLE, AND ASSEMBLY | | PROPOSED IS TO BE PROVIDED FOR REVIEW. | | | | ROOF ASSEMBLY TO COMPLY WITH THE PRESSURES ON SHEET | | S4.10. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
P |
Date |
2018-12-13 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-12-12 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-12-12 |
Time |
16:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
F |
Date |
2018-12-12 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-12-12 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-12-12 |
Time |
14:27 |
Sent To |
|
|
Notes |
2018-12-12 15:06:12 | PLEASE UPLOAD THESE TWO SHEETS WITH DIGITAL SIGNATURE. | | 120 - S2.03 B-PT | | 121 - S2.03 B-R | | | | SHEETS S-3.00 THRU S3.06 WILL BE DELETED SINCE THEY | | WEREN'T RE-LOADED WITH DIGITAL SIGNATURE, AND THOSE | | DRAWINGS ARE NOT REFERENCES BY ANY OTHER STRUCTURAL | | DRAWING. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2018-12-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-12-04 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-12-04 |
Time |
17:09 |
Sent To |
|
|
Notes |
2018-12-04 17:16:44 | THE FOLLOWING SHEETS ARE NOT DIGITALLY SIGNED: | | | | S2.00 | | S2.00A | | S2.00B | | S2.01 | | S2.01A | | S2.01B | | S2.02 | | S2.02A PT | | S2.02A R | | S2.02B PT | | S2.02B R | | S2.03 | | S2.03A PT | | S2.03A R | | S2.06 | | S2.06A | | S2.06B | | S3.00 | | S3.01 | | S3.02 | | S3.03 | | S3.04 | | S3.05 | | S3.06 | | S3.09 | | S7.00 | | S7.01 | | S7.02 | | S7.03 | | S7.04 | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-11-14 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-11-14 |
Time |
11:03 |
Sent To |
|
|
Notes |
2018-11-14 11:03:54 | SIGNATURES WILL BE VERIFIED AFTER ALL REVIEWS HAVE | | PASSED | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2018-05-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-04 |
Time |
07:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-04 |
Time |
06:06 |
Sent To |
|
|
Notes |
2018-05-08 12:59:20 | 5/8/18 THESES PLUMBING SHEETS ARE MISSING THE DIGITAL | | SIGNATURE THE DIGITAL SIGNATURES ARE INVALID ON | | PLUMBING PAGES THEY SHALL COMPLY WITH FAC 61G15-23.003 | | P-1.3.00 | | P- 1.5.10 | | P-4.0.02 | | P-4.0.01 | | P-1.5.09 | | P-1.3.05B | | P-1.3.05A | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | 2018-05-04 07:00:38 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. THE MAJORITY OF A SHEETS ARE NOT DIGITALLY SIGNED | | AND SEALED. A0.0.01, BUT EVERY OTHER A SHEET CHECKED IS | | NOT SIGNED AND SEALED, FS481, FOR EXAMPLE: | | A1.1.05, A1.2.02, A1.4.02B, A1.5.05, A1.7.03B, TOO MANY | | TO LIST | | | | 2. SURVEY NOT SIGNED & SEALED; APPLICANT CAN PROVIDE A | | PAPER ORIGINAL IF SURVEYOR DOES NOT HAVE A DIGITAL | | SEAL. | | | | 3. S SHEETS CHECKED ARE DIGITALLY SIGNED AND SEALED - | | OK. NEW SHEETS SUBMITTED FOR A THIRD REVIEW CYCLE NEED | | VERIFICATION, IF APPLICABLE. | | | | 4. FP SHEETS ARE NOT DIGITALLY SIGNED AND SEALED, | | FS471. | | | | 5. M SHEETS CHECKED ARE DIGITALLY SIGNED AND SEALED - | | OK. NEW SHEETS SUBMITTED FOR A THIRD REVIEW CYCLE NEED | | VERIFICATION, IF APPLICABLE. | | | | 6. P SHEETS CHECKED ARE DIGITALLY SIGNED AND SEALED - | | OK. NEW SHEETS SUBMITTED FOR A THIRD REVIEW CYCLE NEED | | VERIFICATION, IF APPLICABLE. | | | | 7. ONE E SHEET IS DIGITALLY SIGNED AND SEALED | | (E0.0.01), THE REMAINDER CHECKED ARE NOT DIGITALLY | | SIGNED AND SEALED, FS471 (FOR EXAMPLE, E5.1.05, | | 5.1.0-8). | | | | 8. CIVIL SHEETS ARE NOT DIGITALLY SIGNED AND SEALED, | | FS471. | | | | 9. D SHEETS ARE NOT DIGITALLY SIGNED AND SEALED. | | | | 10. L SHEETS ARE LABELED "FOR REFERENCE ONLY"; A | | SEPARATE PERMIT WITH SEPARATE PLANS, APPLICATION, FEES | | IS REQUIRED. SIGNED AND SEALED PAGES ARE REQUIRED AT | | THAT TIME. | | | | 11. DUE TO THE DISCREPANCIES IN OTHER SHEETS, WHEN | | RESUBMITTING VERIFY ALL SHEETS, INCLUDING PAGES NOTED | | AS OK. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2017-05-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-05-11 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-05-11 |
Time |
13:40 |
Sent To |
|
|
Notes |
2017-05-11 13:41:35 | APPLICANT IS TO CONFIRM THAT ALL SHEETS ARE | | INDIVIDUALLY DIGITALLY SIGNED PRIOR TO RESUBMITTAL | | | | IF APPLICANT IS UNABLE TO DO SO, PLEASE CONTACT ME | | REGARDING OTHER OPTIONS. | | | | SAMANTHA HILL | | [email protected] | | 561-805-6724 | 2017-04-21 13:05:43 | 4/21/17 PLUMB SHEETS NOT DIGITALLY SIGNED/GPJ | 2017-04-17 11:23:49 | THRESHOLD INSPECTION PLAN OK | | ARCHITECTURAL, STRUCTURAL, CIVIL SHEETS NOT DIGITALLY | | SIGNED | | | | | | | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
4 |
Status |
P |
Date |
2018-11-27 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-10-16 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-10-16 |
Time |
14:20 |
Sent To |
|
|
Notes |
2018-11-27 12:41:00 | SI AGREEMENT APPROVED BY KC | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. THRESHOLD INSPECTION PLAN = OK. | | | | 2. THRESHOLD STATEMENT ON PLANS, ARCHITECT: OK | | THRESHOLD STATEMENT ON PLANS, ENGINEER: OK | | | | 3. SPECIAL INSPECTOR AGREEMENT - | | | | ANDREW PATRICK SULLIVAN, PE 54091, SI | | INSPECTOR: CHAD CASSETT, PE 80449 | | CONTRACTOR: DON PERRY | | OWNER: DOMINIC GATTO | | | | PENDING RECEIPT OF ADDITIONAL INSPECTOR AND RESUME | | | | | 2018-10-16 14:21:46 | [FBC AMENDED 109]PLANS WILL BE REVIEWED BY THE PBC | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
3 |
Status |
F |
Date |
2018-08-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-12 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-07 |
Time |
15:48 |
Sent To |
|
|
Notes |
2018-07-07 15:57:57 | SI AGREEMENT APPROVED BY KC | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. THRESHOLD INSPECTION PLAN = OK. | | | | 2. THRESHOLD STATEMENT ON PLANS, ARCHITECT: OK | | THRESHOLD STATEMENT ON PLANS, ENGINEER: OK | | | | 3. SPECIAL INSPECTOR AGREEMENT - | | | | ANDREW PATRICK SULLIVAN, PE 54091, SI | | INSPECTOR: CHAD CASSETT, PE 80449 | | CONTRACTOR: DON PERRY | | OWNER: DOMINIC GATTO | | | | PENDING RECEIPT OF ADDITIONAL INSPECTOR AND RESUME | | | | | | | | | | | | | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
2 |
Status |
F |
Date |
2018-05-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-07 |
Time |
06:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-07 |
Time |
06:10 |
Sent To |
|
|
Notes |
2018-05-07 06:18:47 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. THRESHOLD INSPECTION PLAN = OK. | | | | 2. THRESHOLD STATEMENT ON PLANS, ARCHITECT: OK | | THRESHOLD STATEMENT ON PLANS, ENGINEER: OK | | | | 3. SPECIAL INSPECTOR AGREEMENT - NEEDS; SEND VIA EMAIL | | WHEN AVAILABLE | | | | 4. RESUMES FOR INSPECTORS (SI, BN) - NEEDS; SEND VIA | | EMAIL WHEN AVAILABLE | | | | | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2017-04-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-24 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-24 |
Time |
11:35 |
Sent To |
|
|
Notes |
2017-04-17 07:24:57 | THRESHOLD INSPECTION PLAN OK | | SEE BUILDING REVIEW FOR OTHER COMMENTS | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2018-11-14 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2018-11-14 |
Time |
13:40 |
Sent To |
|
|
Notes |
2018-11-14 13:40:18 | NO COMMENTS, PLANS WILL BE STAMPED/PASSED WHEN APPROVED | | BY ALL OTHER TRADES. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-10-01 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2018-10-01 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2018-10-01 |
Time |
11:31 |
Sent To |
|
|
Notes |
2018-10-01 11:31:21 | NO COMMENTS, PLANS WILL BE STAMPED/PASSED WHEN APPROVED | | BY ALL OTHER TRADES. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-06-07 |
|
|
Cont ID |
|
Sent By |
JR |
Date |
2018-06-07 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2018-06-07 |
Time |
13:33 |
Sent To |
|
|
Notes |
2018-06-07 13:34:04 | NO COMMENTS, PLANS WILL BE STAMPED/PASSED WHEN APPROVED | | BY ALL OTHER TRADES. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-05-04 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-05-04 |
Time |
11:22 |
Sent To |
|
|
Notes |
2017-05-04 11:22:40 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 05.04.2017 | | PERMIT NO.: 17070911 | | ADDRESS: 3200 N CONGRESS AVENUE | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: | | SCOPE OF REVIEW: NEW HOTEL | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. AS THE SITE PLAN DOES NOT MATCH THAT WHICH WAS | | APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT - | | PLANNING DIVISION VIA MINOR AMENDMENT TO THE BANYAN CAY | | PLANNED DEVELOPMENT ON MAY 13, 2016, AN AMENDMENT TO | | THE PLANNED DEVELOPMENT WILL BE REQUIRED PRIOR TO | | ISSUANCE OF THE PERMIT. SUCH AMENDMENT APPLICATION HAS | | BEEN SUBMITTED BUT SHALL BE APPROVED PRIOR TO ISSUANCE | | OF THE PERMIT. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |