Plan Review Stops For Permit 17020652 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2019-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-03-19 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-03-19 |
Time |
15:02 |
Sent To |
|
|
Notes |
2019-03-19 15:09:44 | RESIDENTIAL (R3) ALTERATION, FIFTH BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014) | | | | 1- APPLICATION WAS ABANDONED AND INVALID. SEC. 105.3.2 | | CITY AMENDMENTS. | | | | LAST BUILDING REVIEW WAS DONE ON 11/01/2017. | | 6/22/2018 ABANDON APPLICATION EMAIL SENT, PERMIT PACKET | | IN CAROLINA'S DRAWER "1". CC | | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2017-11-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-01 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-31 |
Time |
18:36 |
Sent To |
I |
|
Notes |
2017-10-31 19:03:20 | RESIDENTIAL (R3) ALTERATION, FOURTH BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014) | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. | | CONTRACTOR TO BRING REQUIRED INFORMATION PRIOR TO | | INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO | | ADVICE IF PROVISO OPTION IS PREFERRED AT HIS TIME. | | CONTRACTOR TO BRING PLANS TO PALM BEACH COUNTY FOR | | IMPACT FEES ASSESSMENT BEFORE ISSUING PERMIT. | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) WINDOW MULLIONS. NOA 14-1105.01 SUBMITTED EXPIRED ON | | MAY 26, 2016. NEED TO PROVIDE CURRENT NOA. AND, SPECIFY | | MULLION SIZE. | | | | B) EXTERIOR SWING DOORS. PROVIDE FLORIDA PRODUCT | | APPROVAL COVER PAGE THAT CORRESPONDS TO JELD WEN | | DRAWING NO S-2104 SUBMITTED. | | | | 2- ENGINEER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | | | 3- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY | | PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A | | PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM | | BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES | | ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF | | PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2017-07-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-13 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-07-13 |
Time |
07:43 |
Sent To |
|
|
Notes |
2017-07-12 18:55:12 | RESIDENTIAL (R3) ALTERATION, THIRD BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014) | | | | 1- NEW COMMENT: ENGINEER OF RECORD CHANGED THE SCOPE OF | | WORK SHOWN ON SHEET S-1. ALTERATION LEVEL WAS CHANGED | | FROM ALTERATION LEVEL 3 TO ALTERATION LEVEL 2. THIS IS | | 100% INCORRECT. THE SCOPE OF WORK IS CLEARLY ALTERATION | | LEVEL 3 AS STATED ON PREVIOUS SUBMITTAL. REVISE AS | | REQUIRED. SEC. 505 FBC-EXISTING BUILDING, 5TH EDITION | | (2014). ALSO, THE SCOPE OF WORK WAS REVISED TO STATE | | THAT " NO MECHANICAL ON THIS PROJECT". THIS IS | | INCORRECT ALSO. MECHANICAL WORK IS REQUIRED BECAUSE | | NEED TO PROVIDE HEATING. AND, PROPOSED PLAN SHOWS A NEW | | AHU CLOSET AND CONDENSER UNIT OUTSIDE. REVISE AS | | REQUIRED. | | | | 2- NEW COMMENT BASED ON THE NEW COMMENT ABOVE, PLANS | | NEED TO PROVIDE INFORMATION SHOWING COMPLIANCE WITH THE | | HEATING REQUIREMENTS OF SEC. R303.9 FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | | | 3- ORIGINAL COMMENT: VALUATION DECLARED IN THE PERMIT | | APPLICATION IS TOO LOW BASED ON ALL THE SCOPE OF WORK. | | VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S | | OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS | | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. CONTRACTOR TO | | REVISE THE VALUE. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. SINCE | | IT WAS NOT ADDRESSED AFTER THE 3RD REVIEW, THEN THE | | VALUE WAS ESTIMATED TO BE $60,000 +/-. THE PERMIT FEE | | BALANCE IS $1488.24. | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) SINGLE HUNG WINDOWS THAT MEET THE DESIGN PRESSURES | | CALCULATED BY THE ENGINEER OF RECORD ON SHEET S-2. | | DESIGN PRESSURES SHOWN ON NEW SINGLE HUNG WINDOWS NOA | | 14-0908.09 SUBMITTED DON'T MEET THE ENGINEER'S | | CALCULATED DESIGN PRESSURES. | | NOTE; ENGINEER OF RECORD TO CLARIFY WHY HE APPROVED | | THIS SINGLE HUNG PRODUCT APPROVAL IF IT DOESN'T MEET | | THE DESIGN PRESSURES HE CALCULATED. | | | | 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING). ALL DOORS, WINDOWS, WINDOW | | MULLIONS PRODUCT APPROVALS SUBMITTED AS REQUIRED BY | | SEC. 107.3.4.1 CITY AMENDMENTS. | | RESPONSE: REPEAT COMMENT. | | | | 6- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY | | PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A | | PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM | | BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES | | ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF | | PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | *****ENGINEER OF RECORD TO PROVIDE RESPONSE LETTER | | ADDRESSING EACH COMMENT. | | NOTE: PLANS MAY BE SENT TO THE BOARD OF ENGINEER'S FOR | | REVIEW IF PLANS KEEP FAILING THE PLAN REVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-05-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-05-23 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-05-23 |
Time |
12:48 |
Sent To |
HIST |
|
Notes |
2017-05-23 12:53:43 | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014) | | | | 1- ORIGINAL COMMENT: SPECIFY CARBON MONOXIDE ALARMS AS | | REQUIRED BY SEC. R315 FBC-RESIDENTIAL. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | 2- ORIGINAL COMMENT: VALUATION DECLARED IN THE PERMIT | | APPLICATION IS TOO LOW BASED ON ALL THE SCOPE OF WORK. | | VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S | | OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS | | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. CONTRACTOR TO | | REVISE THE VALUE. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | DECLARED VALUE IS EXTREMELY LOW FOR THE SCOPE OF WORK. | | PROVIDE COPIES OF ALL SIGNED CONTRACTS, INCLUDING | | DESIGN PROFESSIONAL FEES FOR BUILDING OFFICIAL REVIEW. | | VALUES MAY BE ADJUSTED ACCORDINGLY. | | | | 3- ORIGINAL COMMENT: PROVIDE COMPLETE AND CORRECT | | ENERGY CALCULATIONS. SEC. R103.1 FBC-ENERGY | | CONSERVATION. REVISE THE FOLLOWING INFORMATION: "SINGLE | | FAMILY" IS NOT A CONSTRUCTION TYPE. REVISE AS REQUIRED. | | PROVIDE THE ACTUAL ORIENTATION OF THE BUILDING. CLIMATE | | ZONE FOR PALM BEACH COUNTY IS 1 NOT 2. REVISE AS | | REQUIRED. OWNER OR LEGALLY AGENT TO CERTIFY FORM | | SUBMITTED. PROVIDE THE DESIGNER INFORMATION. ACCORDING | | TO CITY RECORDS, THIS HOUSE DIDN'T HAVE A/C. PROVIDE | | THE FLOOR, WALLS AND CEILING R-VALUES. PROVIDE CORRECT | | FLOOR AREA. PROVIDE CEILING AREA. PROVIDE WALLS AREA. | | WINDOWS ON WALL #3 AND #4 DON'T MATCH PLANS. REVISE AS | | REQUIRED. PERSON WHO PREPARED THE CALCULATIONS TO | | PROVIDE THE DOORS AND WINDOWS MANUFACTURER'S | | SPECIFICATIONS SHOWING THE U-FACTOR AND SHGC FACTOR | | USED ON THE CALCULATIONS. THIS HOUSE DOESN'T HAVE SLAB | | ON GRADE. SEE PLANS AND REVISE AS REQUIRED. PROVIDE | | COMPLETE INFORMATION FOR HEATING, COOLING, WATER | | HEATER, ETC. | | RESPONSE: THERE WAS NOT RESPONSE TO THIS ITEM BUT I | | FOUND THAT THIS HOUSE IS CONSIDERED A CONTRIBUTING | | HISTORIC BUILDING. THEREFORE, THE ENERGY CALCULATIONS | | ARE NOT REQUIRED. IF CONTRACTOR WANTS TO SUBMIT ENERGY | | CALCULATIONS, THEN THE ABOVE REVISIONS ARE REQUIRED. | | | | 4- ORIGINAL COMMENT: ENGINEER OF RECORD TO SPECIFY HOW | | THE NEW "S" CLAY TILE IS GOING TO BE INSTALLED AS | | REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. IF | | SPECIFYING SCREWS, THEN SPECIFY SIZE AND NUMBER OF | | SCREWS. IF SPECIFYING ADHESIVE, THEN PROVIDE PRODUCT | | APPROVAL. | | RESPONSE: SCOPE OF WORK WAS REVISED. EXTERIOR | | ELEVATIONS NOS CALL FOR "EXISTING ROOFING NO WORK". | | ACCORDING TO ROOFING PERMIT #15040718 THE ROOFING | | MATERIAL OF THE FRONT PORCH IS SHINGLES NOT CONCRETE | | TILE. THIS IS A CONTRIBUTING HISTORIC HOUSE. COORDINATE | | WITH THE HISTORIC PLAN REVIEWER. NOTE: EXTERIOR | | ELEVATIONS ELEVATIONS NEED TO SHOW THE CORRECT ROOFING | | MATERIAL SHINGLES OR CONCRETE TILE SPECIALLY FOR A | | CONTRIBUTING HISTORIC BUILDING. PUBLIC RECORDS NEED TO | | SHOW CORRECT INFORMATION. | | | | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) ORIGINAL COMMENT: NEW "S" CLAY TILE AS SPECIFIED ON | | PLANS. | | RESPONSE: NO PRODUCT APPROVAL WAS SUBMITTED AT THIS | | TIME. THIS NEEDS TO BE COORDINATED WITH THE HISTORIC | | REVIEWER AND ITEM #4 ABOVE. | | | | B) ORIGINAL COMMENT: CLAY TILE ADHESIVE (IF SPECIFIED | | BY THE ENGINEER OF RECORD). SEE ROOF TILE PRODUCT | | APPROVAL FOR LISTED ADHESIVES. | | RESPONSE: COORDINATE WITH ITEM #5(A) ABOVE. | | | | C) ORIGINAL COMMENT: HURRICANE SHUTTERS. AND, PROVIDE | | COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | D) ORIGINAL COMMENT: ALL SIMPSON STRUCTURAL CONNECTORS | | SPECIFIED ON ALL DETAILS. PROVIDE ONLY THE FLORIDA | | PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING THE | | SPECIFIED CONNECTOR OR ENGINEER OF RECORD TO LIST THE | | FLORIDA PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED | | CONNECTOR. | | RESPONSE: REPEAT COMMENT. ENGINEER TO SPECIFY THE | | FLORIDA PRODUCT APPROVAL NEXT TO ALL SPECIFIED | | CONNECTORS ON ALL DETAILS SUBMITTED NOT JUST ON THE | | TYPICAL WALL SECTION. | | | | 6- ORIGINAL COMMENT: ENGINEER OF RECORD TO REVIEW AND | | APPROVE IN WRITING (NOT SIGNING AND SEALING) ALL | | PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | 7- ORIGINAL COMMENT: CLARIFY WHY SUBMITTING NOA | | 14-0908.17 FOR FIXED WINDOWS. PLANS DON'T SHOW ANY | | FIXED WINDOW. IN ADDITION THE WINDOWS DON'T MEET THE | | CALCULATED DESIGN PRESSURES SHOWN ON SHEET S-2. SEC. | | 107.2.1 CITY AMENDMENTS. | | RESPONSE: REPEAT COMMENT. NOW SUBMITTING NOA 14-0908.18 | | FOR FIXED WINDOWS, BUT THERE ARE NO FIXED WINDOWS | | SPECIFIED ON PLANS. | | | | 8- NEW WINDOW SCHEDULE SHOWN ON SHEET S-1: ENGINEER OF | | RECORD SPECIFIES WINDOWS WITH IMPACT GLASS. PRODUCT | | APPROVAL SUBMITTED IS FOR NON-IMPACT GLASS. REVISE AS | | REQUIRED TO MATCH. IT'S NOT CLEAR WHAT TYPE OF WINDOWS | | ARE GOING TO BE INSTALLED. COORDINATE WITH OWNER AND | | CONTRACTOR. SEC. 107.2.1 CITY AMENDMENTS. | | | | 9- SINCE WINDOW PRODUCT APPROVAL SUBMITTED IS FOR | | NON-IMPACT SINGLE HUNG WINDOWS, THEN NEED TO SPECIFY | | SAFETY GLASS FOR THE BATHROOM WINDOW AS REQUIRED BY | | SEC. R308.4.5 FBC-RESIDENTIAL. | | | | 10- ORIGINAL COMMENT: ACCORDING TO CITY RECORDS AND | | PALM BEACH COUNTY PROPERTY APPRAISER THE PROPOSED | | UTILITY ROOM WAS A PORCH. AFTER PLANS ARE REVISED, | | BRING THEM TO PALM BEACH COUNTY (2300 N. JOG RD) FOR | | IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED PLANS | | AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT | | FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | IMPORTANT TO EXPEDITE REVIEW PROCESS: | | *****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | *****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-03-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-22 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-22 |
Time |
14:54 |
Sent To |
|
|
Notes |
2017-03-22 15:46:57 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014) | | | | 1- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY | | PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A | | PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM | | BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES | | ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF | | PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | | | 2- WINDOWS ON PROPOSED BEDROOM #1 DON'T SEEM TO COMPLY | | WITH THE EGRESS REQUIREMENTS. PROVIDE MANUFACTURER'S | | SPECIFICATIONS SHOWING THAT THE SPECIFIED SIZE | | (24"X63") COMPLIES WITH ALL THE EGRESS REQUIREMENTS | | (INCLUDING THE CLEAR WIDTH). SEC. R310 FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | (THIS ITEM REQUESTED BASED ON THE DEMOLITION PLAN | | PROVIDED). | | | | 3- SPECIFY CARBON MONOXIDE ALARMS AS REQUIRED BY SEC. | | R315 FBC-RESIDENTIAL. | | | | 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW BASED ON ALL THE SCOPE OF WORK. VALUATION TO | | INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND | | PROFIT AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED BY | | SEC. 109.3 CITY AMENDMENTS. CONTRACTOR TO REVISE THE | | VALUE. | | | | 5- PROVIDE DOORS AND WINDOWS MANUFACTURER'S | | SPECIFICATIONS SHOWING COMPLIANCE WITH THE DOORS AND | | WINDOWS U-FACTOR AND SHGC FACTOR SPECIFIED ON THE | | ENERGY CALCULATIONS SUBMITTED AS REQUIRED BY SEC. | | R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | 6- PROVIDE COMPLETE AND CORRECT ENERGY CALCULATIONS. | | SEC. R103.1 FBC-ENERGY CONSERVATION. REVISE THE | | FOLLOWING INFORMATION: "SINGLE FAMILY" IS NOT A | | CONSTRUCTION TYPE. REVISE AS REQUIRED. PROVIDE THE | | ACTUAL ORIENTATION OF THE BUILDING. CLIMATE ZONE FOR | | PALM BEACH COUNTY IS 1 NOT 2. REVISE AS REQUIRED. OWNER | | OR LEGALLY AGENT TO CERTIFY FORM SUBMITTED. PROVIDE THE | | DESIGNER INFORMATION. ACCORDING TO CITY RECORDS, THIS | | HOUSE DIDN'T HAVE A/C. PROVIDE THE FLOOR, WALLS AND | | CEILING R-VALUES. PROVIDE CORRECT FLOOR AREA. PROVIDE | | CEILING AREA. PROVIDE WALLS AREA. WINDOWS ON WALL #3 | | AND #4 DON'T MATCH PLANS. REVISE AS REQUIRED. PERSON | | WHO PREPARED THE CALCULATIONS TO PROVIDE THE DOORS AND | | WINDOWS MANUFACTURER'S SPECIFICATIONS SHOWING THE | | U-FACTOR AND SHGC FACTOR USED ON THE CALCULATIONS. THIS | | HOUSE DOESN'T HAVE SLAB ON GRADE. SEE PLANS AND REVISE | | AS REQUIRED. PROVIDE COMPLETE INFORMATION FOR HEATING, | | COOLING, WATER HEATER, ETC. | | | | 7- ENGINEER OF RECORD TO SPECIFY HOW THE NEW "S" CLAY | | TILE IS GOING TO BE INSTALLED AS REQUIRED BY SEC. | | 107.2.1.2 CITY AMENDMENTS. IF SPECIFYING SCREWS, THEN | | SPECIFY SIZE AND NUMBER OF SCREWS. IF SPECIFYING | | ADHESIVE, THEN PROVIDE PRODUCT APPROVAL. | | | | 8- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A) NEW "S" CLAY TILE AS SPECIFIED ON PLANS. | | | | B) CLAY TILE ADHESIVE (IF SPECIFIED BY THE ENGINEER OF | | RECORD). SEE ROOF TILE PRODUCT APPROVAL FOR LISTED | | ADHESIVES. | | | | C) HURRICANE SHUTTERS. AND, PROVIDE COMPLETE | | INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | | | D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ALL | | DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL | | COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR | | ENGINEER OF RECORD TO LIST THE FLORIDA PRODUCT APPROVAL | | NUMBER NEXT TO EACH SPECIFIED CONNECTOR. | | | | 9- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 10- CLARIFY WHY SUBMITTING NOA 14-0908.17 FOR FIXED | | WINDOWS. PLANS DON'T SHOW ANY FIXED WINDOW. IN ADDITION | | THE WINDOWS DON'T MEET THE CALCULATED DESIGN PRESSURES | | SHOWN ON SHEET S-2. SEC. 107.2.1 CITY AMENDMENTS. | | | | 11- DESIGN LOADS INFORMATION ON SHEET S-1: | | A) OCCUPANCY USE/TYPE INFORMATION IS NOT CLEAR. WHAT IS | | "0800- MULTI FAMILY DETACHED (SFD)RESIDENCE"???. THERE | | IS NOT SUCH A THING. REVISE AS REQUIRED. PROVIDE | | CORRECT INFORMATION. SEC. 107.2.1 CITY AMENDMENTS. | | | | B) THE ULTIMATE WIND LOAD INFORMATION IS NOT CLEAR. | | THERE IS ONE AREA THAT CALLS FOR 170 MPH ULTIMATE, | | WHILE AT THE BOTTOM OF DESIGN CRITERIA CALLS FOR 175 | | MPH. REVISE AS REQUIRED. PROVIDE CLEAR INFORMATION. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | C) DESIGN CRITERIA AT THE BOTTOM REFERENCES THE FBC-10. | | NEED TO REFERENCE THE CURRENT 2014 BUILDING CODE AS | | REQUIRED BY CHAPTER 553 F.S. | | | | 12- WINDOWS ON THE NEW WEST ELEVATION ARE LABELED AS | | INTERIOR ZONE WINDOWS. THIS IS INCORRECT. THEY ARE END | | ZONE WINDOWS. SAME THING APPLIES TO THE FIRST WINDOW OF | | BEDROOM #2 ON NEW SOUTH ELEVATION. REVISE AS REQUIRED. | | FIGURE R301.2(7) FBC-RESIDENTIAL. | | NOTE: REVISE PROPOSED FLOOR PLAN ALSO. LABEL THE | | WINDOWS CORRECTLY. | | | | *****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | *****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-03-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-20 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-20 |
Time |
07:43 |
Sent To |
|
|
Notes |
2017-03-20 09:15:59 | | | NOTE: | | PLAN REVIEW FEES ARE NOT PAID. REVIEW WILL BE PERFORMED | | WHEN THE FEES ARE PAID. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2017-10-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-27 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-10-27 |
Time |
08:39 |
Sent To |
|
|
Notes |
2017-10-27 08:39:17 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ELECTRICAL RISER DIAGRAM SHOWS A 1/0 WIRE FOR THE | | 200 AMP PANEL. 1/0 WIRE IS NOT RATED FOR A 200 AMP | | SERVICE. PROVIDE CORRECTION. NEC 310.15(B)(7) AND | | (B)(15); FBC RE TABLE E3601.3 | | 2. ELECTRICAL RISER DIAGRAM SHOWS A # 6 GROUNDING | | ELECTRODE CONDUCTOR (GEC). BASED ON COMMENT # 1 AND THE | | INCREASED WIRE SIZE THAT WILL BE REQUIRED FOR THE | | SERVICE, THIS WIRE IS TOO SMALL. PROVIDE CORRECTION. | | NEC 250.66; FBC RE TABLE E3601.3 | | 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. NEC 250.94; FBC RE3609.3 | | 4. ELECTRICAL RISER DIAGRAM DOES NOT MATCH WHAT IS | | DRAWN ON PLAN. PLAN SHOWS A METER CAN, DISCONNECT, AND | | INTERIOR PANEL. RISER SHOWS A METER CAN AND MAIN | | BREAKER PANEL. CLARIFY AND/OR CORRECT. FBC 107.2.1; NEC | | 215.5 | | 5. LOAD CALCULATION PROVIDED IS NOT CORRECT. LOAD | | CALCULATION IS MISSING SEVERAL ITEMS AND NOT PREPARED | | PROPERLY. SEE FBC RESIDENTIAL OR THE NEC FOR EXAMPLE. | | PROVIDE CORRECTED LOAD CALCULATION WITH ALL LOADS | | INCLUDED. NEC 220; FBC RE3602.3 | | 6. PANEL SCHEDULE CALLS FOR A 30 AMP BREAKER FOR WATER | | HEATER. BASED ON THE LOAD OF THIS UNIT STATED, THIS | | BREAKER IS TOO SMALL. PROVIDE ACCURATE OCP FOR THE | | TANKLESS WATER HEATER. NEC 110.3, 210.20, 240.4; FBC RE | | 3705.5 | | 7. PANEL SCHEDULE SHOWS A WINDOW UNIT AC. PLAN SHOWS AN | | A/C UNIT WITH AHU. CLARIFY AND/OR CORRECT. PROVIDE ALL | | CIRCUITS AND LOADS IN PANEL SCHEDULE. FBC 107.2.1; NEC | | 220; FBC RE 3602.3 | | 8. PANEL SCHEDULE SHOWS ONLY ONE LIGHTING CIRCUIT. | | BASED ON SQUARE FOOTAGE OF HOME, A MINIMUM OF 2 | | LIGHTING CIRCUITS WOULD BE REQUIRED. ADDITIONALLY, THE | | 2 SMALL APPLIANCE CIRCUITS REQUIRED ARE NOT SHOWN. SHOW | | ALL REQUIRED BRANCH CIRCUITS IN PANEL SCHEDULE AND LOAD | | CALCULATION. FBC 107.2.1; NEC 220; FBC RE 3602.3 | | 9. SHEET E-1 STATES THAT THIS IS A DEMO PLAN, BUT NEW | | WORK INSTALLED IS SHOWN. REMOVE CONFLICTING STATEMENT. | | FBC 107.2.1 | | 10. ELECTRICAL NOTE 3 STATES THAT RECEPTACLES SHALL BE | | TAMPER RESISTANT PER NEC 406.11. THIS CODE SECTION DOES | | NOT APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE4002.14 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-07-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-07-18 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-07-18 |
Time |
17:54 |
Sent To |
|
|
Notes |
2017-07-18 17:58:22 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | RISER DIAGRAM SHOWS BARN PANEL? | | | | 100A PANEL SCHEDULE IS WHICH BUILDING? | | | | 100A PANEL SCHEDULE HAS SEVERAL LOADS EITHER UNDERSIZED | | ON BREAKER OR TOO LARGE OF A BREAKER. | | | | LOAD CALCULATION REQUIRED FOR 200A SERVICE. | | | | OUTLET SPACING ON FLOOR PLAN SHOWN DOES NOT MEET CODE. | | | | IF BARN WORK IS GOING ON WE NEED A FLOOR PLAN FOR | | BARN.. | 2017-07-13 14:41:51 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-07-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-03-06 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-03-06 |
Time |
15:26 |
Sent To |
|
|
Notes |
2017-03-06 16:09:54 | CHANGED PASS TO FAIL DUE TO RESUBMITTAL JLEAHY SEE | | COMMENTS FOR RESUBMITTAL | | | | IF BARN WORK IS GOING TO BE COMPLETED UNDER THIS PERMIT | | SUBMIT A BARN PLAN FOR REVIEW JLEAHY | 2017-03-06 16:06:51 | NEEDS LOAD CALCULATION FOR THE 200A MAIN | | OUTLET SPACING NOT TO CODE. | | BARN NOT SHOWN ON DRAWINGS |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2017-10-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-10-26 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-10-18 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2017-07-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-07-11 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-07-11 |
Time |
09:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2017-05-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-05-26 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-05-26 |
Time |
10:21 |
Sent To |
|
|
Notes |
2017-05-26 10:22:36 | FHM SPOKE TO NICK 5/26...SCHEDULED MEETING FOR 5/30 TO | | REVIEW PLANS AND CONCERNS. PERMIT ON HISTORIC DESK TO | | USE FOR MEETING. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2019-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-03-19 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-03-12 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2017-11-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-01 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-03 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-07-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-07-18 |
Time |
18:00 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-06-29 |
Time |
13:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-05-30 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-05-30 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-05-04 |
Time |
10:24 |
Sent To |
|
|
Notes |
2017-05-11 10:24:29 | RESUB ROUTED TO GJOHNSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-03-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-23 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-21 |
Time |
13:40 |
Sent To |
|
|
Notes |
2017-03-21 13:40:39 | FEES PAID, GIVEN TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-03-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-20 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-14 |
Time |
11:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
F |
Date |
2017-11-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-01 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-01 |
Time |
13:24 |
Sent To |
|
|
Notes |
2017-11-01 13:25:14 | 1- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY | | PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A | | PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM | | BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES | | ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF | | PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2017-07-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-13 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-07-13 |
Time |
14:42 |
Sent To |
|
|
Notes |
2017-07-13 14:43:01 | 1- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY | | PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A | | PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM | | BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES | | ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF | | PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2017-05-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-05-23 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-05-23 |
Time |
16:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-03-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-22 |
Time |
19:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-22 |
Time |
19:17 |
Sent To |
|
|
Notes |
2017-03-22 19:17:39 | 1- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY | | PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A | | PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM | | BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES | | ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF | | PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE | | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2019-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-11-01 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-11-01 |
Time |
09:29 |
Sent To |
|
|
Notes |
2017-11-01 09:30:59 | 03/19/19 CHANGED STATUS FROM "N" TO "F". APPLICATION | | WAS ABANDONED AND INVALID. SEC. 105.3.2 CITY | | AMENDMENTS. | | | | | | | | | | NO INFORMATION SUBMITTED. PROVIDE COMPLETE MECHANICAL | | PLAN AND EQUIPMENT SIZING CALCULATIONS UNDER A SEPARATE | | PERMIT. JG. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-07-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-07-13 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-07-13 |
Time |
14:53 |
Sent To |
|
|
Notes |
2017-07-13 14:54:46 | RESIDENTIAL (R3) ALTERATION, THIRD MECHANICAL REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- ORIGINAL COMMENT: PROVIDE EQUIPMENT SIZING | | CALCULATIONS AND A/C PLAN. SEC. R403.6 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-05-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-05-23 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-05-23 |
Time |
16:18 |
Sent To |
|
|
Notes |
2017-05-23 16:19:58 | RESIDENTIAL (R3) ALTERATION, SECOND MECHANICAL REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- ORIGINAL COMMENT: PROVIDE EQUIPMENT SIZING | | CALCULATIONS AND A/C PLAN. SEC. R403.6 FBC-ENERGY | | CONSERVATION, 5TH EDITION (2014). | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-03-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-23 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-23 |
Time |
07:13 |
Sent To |
|
|
Notes |
2017-03-23 07:41:38 | RESIDENTIAL (R3) ALTERATION, MECHANICAL REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PROVIDE EQUIPMENT SIZING CALCULATIONS AND A/C PLAN. | | SEC. R403.6 FBC-ENERGY CONSERVATION, 5TH EDITION | | (2014). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2017-10-17 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-10-17 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-10-17 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-07-18 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-18 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-18 |
Time |
09:55 |
Sent To |
|
|
Notes |
2017-07-18 14:43:44 | PROVISO | | | | 1. PROVIDE SANITARY RISER DIAGRAM THAT MATCHES FLOOR | | PLAN RISER SHOWS A TUB THE FLOOR PLAN SHOWS A TUB. | 2017-07-13 14:43:28 | NEW DRAWINGS SUBMITTED. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-05-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-05-12 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-05-12 |
Time |
12:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-03-02 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-02 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-02 |
Time |
13:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-10-26 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-10-26 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-10-26 |
Time |
09:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-07-11 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-07-11 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-07-11 |
Time |
09:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-05-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-05-30 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-05-30 |
Time |
11:18 |
Sent To |
|
|
Notes |
|
|