Plan Review Details - Permit 17020652
Plan Review Stops For Permit 17020652
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2019-03-19 Cont ID  
Sent By jgomez Date 2019-03-19 Time 15:19 Rev Time 0.00
Received By jgomez Date 2019-03-19 Time 15:02 Sent To  
Notes
2019-03-19 15:09:44RESIDENTIAL (R3) ALTERATION, FIFTH BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014)
  
 1- APPLICATION WAS ABANDONED AND INVALID. SEC. 105.3.2
 CITY AMENDMENTS.
  
 LAST BUILDING REVIEW WAS DONE ON 11/01/2017.
 6/22/2018 ABANDON APPLICATION EMAIL SENT, PERMIT PACKET
 IN CAROLINA'S DRAWER "1". CC
  
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2017-11-01 Cont ID  
Sent By jgomez Date 2017-11-01 Time 09:33 Rev Time 0.00
Received By jgomez Date 2017-10-31 Time 18:36 Sent To I
Notes
2017-10-31 19:03:20RESIDENTIAL (R3) ALTERATION, FOURTH BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014)
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO.
 CONTRACTOR TO BRING REQUIRED INFORMATION PRIOR TO
 INSPECTIONS TO AVOID CONFLICTS/DELAYS. CONTRACTOR TO
 ADVICE IF PROVISO OPTION IS PREFERRED AT HIS TIME.
 CONTRACTOR TO BRING PLANS TO PALM BEACH COUNTY FOR
 IMPACT FEES ASSESSMENT BEFORE ISSUING PERMIT.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) WINDOW MULLIONS. NOA 14-1105.01 SUBMITTED EXPIRED ON
 MAY 26, 2016. NEED TO PROVIDE CURRENT NOA. AND, SPECIFY
 MULLION SIZE.
  
 B) EXTERIOR SWING DOORS. PROVIDE FLORIDA PRODUCT
 APPROVAL COVER PAGE THAT CORRESPONDS TO JELD WEN
 DRAWING NO S-2104 SUBMITTED.
  
 2- ENGINEER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 3- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY
 PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A
 PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM
 BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES
 ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2017-07-13 Cont ID  
Sent By jgomez Date 2017-07-13 Time 14:30 Rev Time 0.00
Received By jgomez Date 2017-07-13 Time 07:43 Sent To  
Notes
2017-07-12 18:55:12RESIDENTIAL (R3) ALTERATION, THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014)
  
 1- NEW COMMENT: ENGINEER OF RECORD CHANGED THE SCOPE OF
 WORK SHOWN ON SHEET S-1. ALTERATION LEVEL WAS CHANGED
 FROM ALTERATION LEVEL 3 TO ALTERATION LEVEL 2. THIS IS
 100% INCORRECT. THE SCOPE OF WORK IS CLEARLY ALTERATION
 LEVEL 3 AS STATED ON PREVIOUS SUBMITTAL. REVISE AS
 REQUIRED. SEC. 505 FBC-EXISTING BUILDING, 5TH EDITION
 (2014). ALSO, THE SCOPE OF WORK WAS REVISED TO STATE
 THAT " NO MECHANICAL ON THIS PROJECT". THIS IS
 INCORRECT ALSO. MECHANICAL WORK IS REQUIRED BECAUSE
 NEED TO PROVIDE HEATING. AND, PROPOSED PLAN SHOWS A NEW
 AHU CLOSET AND CONDENSER UNIT OUTSIDE. REVISE AS
 REQUIRED.
  
 2- NEW COMMENT BASED ON THE NEW COMMENT ABOVE, PLANS
 NEED TO PROVIDE INFORMATION SHOWING COMPLIANCE WITH THE
 HEATING REQUIREMENTS OF SEC. R303.9 FBC-RESIDENTIAL,
 5TH EDITION (2014).
  
 3- ORIGINAL COMMENT: VALUATION DECLARED IN THE PERMIT
 APPLICATION IS TOO LOW BASED ON ALL THE SCOPE OF WORK.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. CONTRACTOR TO
 REVISE THE VALUE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. SINCE
 IT WAS NOT ADDRESSED AFTER THE 3RD REVIEW, THEN THE
 VALUE WAS ESTIMATED TO BE $60,000 +/-. THE PERMIT FEE
 BALANCE IS $1488.24.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) SINGLE HUNG WINDOWS THAT MEET THE DESIGN PRESSURES
 CALCULATED BY THE ENGINEER OF RECORD ON SHEET S-2.
 DESIGN PRESSURES SHOWN ON NEW SINGLE HUNG WINDOWS NOA
 14-0908.09 SUBMITTED DON'T MEET THE ENGINEER'S
 CALCULATED DESIGN PRESSURES.
 NOTE; ENGINEER OF RECORD TO CLARIFY WHY HE APPROVED
 THIS SINGLE HUNG PRODUCT APPROVAL IF IT DOESN'T MEET
 THE DESIGN PRESSURES HE CALCULATED.
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING). ALL DOORS, WINDOWS, WINDOW
 MULLIONS PRODUCT APPROVALS SUBMITTED AS REQUIRED BY
 SEC. 107.3.4.1 CITY AMENDMENTS.
 RESPONSE: REPEAT COMMENT.
  
 6- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY
 PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A
 PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM
 BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES
 ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 *****ENGINEER OF RECORD TO PROVIDE RESPONSE LETTER
 ADDRESSING EACH COMMENT.
 NOTE: PLANS MAY BE SENT TO THE BOARD OF ENGINEER'S FOR
 REVIEW IF PLANS KEEP FAILING THE PLAN REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2017-05-23 Cont ID  
Sent By jgomez Date 2017-05-23 Time 16:12 Rev Time 0.00
Received By jgomez Date 2017-05-23 Time 12:48 Sent To HIST
Notes
2017-05-23 12:53:43RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014)
  
 1- ORIGINAL COMMENT: SPECIFY CARBON MONOXIDE ALARMS AS
 REQUIRED BY SEC. R315 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 2- ORIGINAL COMMENT: VALUATION DECLARED IN THE PERMIT
 APPLICATION IS TOO LOW BASED ON ALL THE SCOPE OF WORK.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. CONTRACTOR TO
 REVISE THE VALUE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL.
 DECLARED VALUE IS EXTREMELY LOW FOR THE SCOPE OF WORK.
 PROVIDE COPIES OF ALL SIGNED CONTRACTS, INCLUDING
 DESIGN PROFESSIONAL FEES FOR BUILDING OFFICIAL REVIEW.
 VALUES MAY BE ADJUSTED ACCORDINGLY.
  
 3- ORIGINAL COMMENT: PROVIDE COMPLETE AND CORRECT
 ENERGY CALCULATIONS. SEC. R103.1 FBC-ENERGY
 CONSERVATION. REVISE THE FOLLOWING INFORMATION: "SINGLE
 FAMILY" IS NOT A CONSTRUCTION TYPE. REVISE AS REQUIRED.
 PROVIDE THE ACTUAL ORIENTATION OF THE BUILDING. CLIMATE
 ZONE FOR PALM BEACH COUNTY IS 1 NOT 2. REVISE AS
 REQUIRED. OWNER OR LEGALLY AGENT TO CERTIFY FORM
 SUBMITTED. PROVIDE THE DESIGNER INFORMATION. ACCORDING
 TO CITY RECORDS, THIS HOUSE DIDN'T HAVE A/C. PROVIDE
 THE FLOOR, WALLS AND CEILING R-VALUES. PROVIDE CORRECT
 FLOOR AREA. PROVIDE CEILING AREA. PROVIDE WALLS AREA.
 WINDOWS ON WALL #3 AND #4 DON'T MATCH PLANS. REVISE AS
 REQUIRED. PERSON WHO PREPARED THE CALCULATIONS TO
 PROVIDE THE DOORS AND WINDOWS MANUFACTURER'S
 SPECIFICATIONS SHOWING THE U-FACTOR AND SHGC FACTOR
 USED ON THE CALCULATIONS. THIS HOUSE DOESN'T HAVE SLAB
 ON GRADE. SEE PLANS AND REVISE AS REQUIRED. PROVIDE
 COMPLETE INFORMATION FOR HEATING, COOLING, WATER
 HEATER, ETC.
 RESPONSE: THERE WAS NOT RESPONSE TO THIS ITEM BUT I
 FOUND THAT THIS HOUSE IS CONSIDERED A CONTRIBUTING
 HISTORIC BUILDING. THEREFORE, THE ENERGY CALCULATIONS
 ARE NOT REQUIRED. IF CONTRACTOR WANTS TO SUBMIT ENERGY
 CALCULATIONS, THEN THE ABOVE REVISIONS ARE REQUIRED.
  
 4- ORIGINAL COMMENT: ENGINEER OF RECORD TO SPECIFY HOW
 THE NEW "S" CLAY TILE IS GOING TO BE INSTALLED AS
 REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. IF
 SPECIFYING SCREWS, THEN SPECIFY SIZE AND NUMBER OF
 SCREWS. IF SPECIFYING ADHESIVE, THEN PROVIDE PRODUCT
 APPROVAL.
 RESPONSE: SCOPE OF WORK WAS REVISED. EXTERIOR
 ELEVATIONS NOS CALL FOR "EXISTING ROOFING NO WORK".
 ACCORDING TO ROOFING PERMIT #15040718 THE ROOFING
 MATERIAL OF THE FRONT PORCH IS SHINGLES NOT CONCRETE
 TILE. THIS IS A CONTRIBUTING HISTORIC HOUSE. COORDINATE
 WITH THE HISTORIC PLAN REVIEWER. NOTE: EXTERIOR
 ELEVATIONS ELEVATIONS NEED TO SHOW THE CORRECT ROOFING
 MATERIAL SHINGLES OR CONCRETE TILE SPECIALLY FOR A
 CONTRIBUTING HISTORIC BUILDING. PUBLIC RECORDS NEED TO
 SHOW CORRECT INFORMATION.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) ORIGINAL COMMENT: NEW "S" CLAY TILE AS SPECIFIED ON
 PLANS.
 RESPONSE: NO PRODUCT APPROVAL WAS SUBMITTED AT THIS
 TIME. THIS NEEDS TO BE COORDINATED WITH THE HISTORIC
 REVIEWER AND ITEM #4 ABOVE.
  
 B) ORIGINAL COMMENT: CLAY TILE ADHESIVE (IF SPECIFIED
 BY THE ENGINEER OF RECORD). SEE ROOF TILE PRODUCT
 APPROVAL FOR LISTED ADHESIVES.
 RESPONSE: COORDINATE WITH ITEM #5(A) ABOVE.
  
 C) ORIGINAL COMMENT: HURRICANE SHUTTERS. AND, PROVIDE
 COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 D) ORIGINAL COMMENT: ALL SIMPSON STRUCTURAL CONNECTORS
 SPECIFIED ON ALL DETAILS. PROVIDE ONLY THE FLORIDA
 PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING THE
 SPECIFIED CONNECTOR OR ENGINEER OF RECORD TO LIST THE
 FLORIDA PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED
 CONNECTOR.
 RESPONSE: REPEAT COMMENT. ENGINEER TO SPECIFY THE
 FLORIDA PRODUCT APPROVAL NEXT TO ALL SPECIFIED
 CONNECTORS ON ALL DETAILS SUBMITTED NOT JUST ON THE
 TYPICAL WALL SECTION.
  
 6- ORIGINAL COMMENT: ENGINEER OF RECORD TO REVIEW AND
 APPROVE IN WRITING (NOT SIGNING AND SEALING) ALL
 PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 7- ORIGINAL COMMENT: CLARIFY WHY SUBMITTING NOA
 14-0908.17 FOR FIXED WINDOWS. PLANS DON'T SHOW ANY
 FIXED WINDOW. IN ADDITION THE WINDOWS DON'T MEET THE
 CALCULATED DESIGN PRESSURES SHOWN ON SHEET S-2. SEC.
 107.2.1 CITY AMENDMENTS.
 RESPONSE: REPEAT COMMENT. NOW SUBMITTING NOA 14-0908.18
 FOR FIXED WINDOWS, BUT THERE ARE NO FIXED WINDOWS
 SPECIFIED ON PLANS.
  
 8- NEW WINDOW SCHEDULE SHOWN ON SHEET S-1: ENGINEER OF
 RECORD SPECIFIES WINDOWS WITH IMPACT GLASS. PRODUCT
 APPROVAL SUBMITTED IS FOR NON-IMPACT GLASS. REVISE AS
 REQUIRED TO MATCH. IT'S NOT CLEAR WHAT TYPE OF WINDOWS
 ARE GOING TO BE INSTALLED. COORDINATE WITH OWNER AND
 CONTRACTOR. SEC. 107.2.1 CITY AMENDMENTS.
  
 9- SINCE WINDOW PRODUCT APPROVAL SUBMITTED IS FOR
 NON-IMPACT SINGLE HUNG WINDOWS, THEN NEED TO SPECIFY
 SAFETY GLASS FOR THE BATHROOM WINDOW AS REQUIRED BY
 SEC. R308.4.5 FBC-RESIDENTIAL.
  
 10- ORIGINAL COMMENT: ACCORDING TO CITY RECORDS AND
 PALM BEACH COUNTY PROPERTY APPRAISER THE PROPOSED
 UTILITY ROOM WAS A PORCH. AFTER PLANS ARE REVISED,
 BRING THEM TO PALM BEACH COUNTY (2300 N. JOG RD) FOR
 IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT
 FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
  
 IMPORTANT TO EXPEDITE REVIEW PROCESS:
 *****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-03-23 Cont ID  
Sent By jgomez Date 2017-03-22 Time 18:46 Rev Time 0.00
Received By jgomez Date 2017-03-22 Time 14:54 Sent To  
Notes
2017-03-22 15:46:57RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 1- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY
 PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A
 PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM
 BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES
 ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- WINDOWS ON PROPOSED BEDROOM #1 DON'T SEEM TO COMPLY
 WITH THE EGRESS REQUIREMENTS. PROVIDE MANUFACTURER'S
 SPECIFICATIONS SHOWING THAT THE SPECIFIED SIZE
 (24"X63") COMPLIES WITH ALL THE EGRESS REQUIREMENTS
 (INCLUDING THE CLEAR WIDTH). SEC. R310 FBC-RESIDENTIAL,
 5TH EDITION (2014).
 (THIS ITEM REQUESTED BASED ON THE DEMOLITION PLAN
 PROVIDED).
  
 3- SPECIFY CARBON MONOXIDE ALARMS AS REQUIRED BY SEC.
 R315 FBC-RESIDENTIAL.
  
 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW BASED ON ALL THE SCOPE OF WORK. VALUATION TO
 INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND
 PROFIT AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED BY
 SEC. 109.3 CITY AMENDMENTS. CONTRACTOR TO REVISE THE
 VALUE.
  
 5- PROVIDE DOORS AND WINDOWS MANUFACTURER'S
 SPECIFICATIONS SHOWING COMPLIANCE WITH THE DOORS AND
 WINDOWS U-FACTOR AND SHGC FACTOR SPECIFIED ON THE
 ENERGY CALCULATIONS SUBMITTED AS REQUIRED BY SEC.
 R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 6- PROVIDE COMPLETE AND CORRECT ENERGY CALCULATIONS.
 SEC. R103.1 FBC-ENERGY CONSERVATION. REVISE THE
 FOLLOWING INFORMATION: "SINGLE FAMILY" IS NOT A
 CONSTRUCTION TYPE. REVISE AS REQUIRED. PROVIDE THE
 ACTUAL ORIENTATION OF THE BUILDING. CLIMATE ZONE FOR
 PALM BEACH COUNTY IS 1 NOT 2. REVISE AS REQUIRED. OWNER
 OR LEGALLY AGENT TO CERTIFY FORM SUBMITTED. PROVIDE THE
 DESIGNER INFORMATION. ACCORDING TO CITY RECORDS, THIS
 HOUSE DIDN'T HAVE A/C. PROVIDE THE FLOOR, WALLS AND
 CEILING R-VALUES. PROVIDE CORRECT FLOOR AREA. PROVIDE
 CEILING AREA. PROVIDE WALLS AREA. WINDOWS ON WALL #3
 AND #4 DON'T MATCH PLANS. REVISE AS REQUIRED. PERSON
 WHO PREPARED THE CALCULATIONS TO PROVIDE THE DOORS AND
 WINDOWS MANUFACTURER'S SPECIFICATIONS SHOWING THE
 U-FACTOR AND SHGC FACTOR USED ON THE CALCULATIONS. THIS
 HOUSE DOESN'T HAVE SLAB ON GRADE. SEE PLANS AND REVISE
 AS REQUIRED. PROVIDE COMPLETE INFORMATION FOR HEATING,
 COOLING, WATER HEATER, ETC.
  
 7- ENGINEER OF RECORD TO SPECIFY HOW THE NEW "S" CLAY
 TILE IS GOING TO BE INSTALLED AS REQUIRED BY SEC.
 107.2.1.2 CITY AMENDMENTS. IF SPECIFYING SCREWS, THEN
 SPECIFY SIZE AND NUMBER OF SCREWS. IF SPECIFYING
 ADHESIVE, THEN PROVIDE PRODUCT APPROVAL.
  
 8- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) NEW "S" CLAY TILE AS SPECIFIED ON PLANS.
  
 B) CLAY TILE ADHESIVE (IF SPECIFIED BY THE ENGINEER OF
 RECORD). SEE ROOF TILE PRODUCT APPROVAL FOR LISTED
 ADHESIVES.
  
 C) HURRICANE SHUTTERS. AND, PROVIDE COMPLETE
 INSTALLATION SCHEDULE. SEE CITY SAMPLE.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON ALL
 DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR
 ENGINEER OF RECORD TO LIST THE FLORIDA PRODUCT APPROVAL
 NUMBER NEXT TO EACH SPECIFIED CONNECTOR.
  
 9- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 10- CLARIFY WHY SUBMITTING NOA 14-0908.17 FOR FIXED
 WINDOWS. PLANS DON'T SHOW ANY FIXED WINDOW. IN ADDITION
 THE WINDOWS DON'T MEET THE CALCULATED DESIGN PRESSURES
 SHOWN ON SHEET S-2. SEC. 107.2.1 CITY AMENDMENTS.
  
 11- DESIGN LOADS INFORMATION ON SHEET S-1:
 A) OCCUPANCY USE/TYPE INFORMATION IS NOT CLEAR. WHAT IS
 "0800- MULTI FAMILY DETACHED (SFD)RESIDENCE"???. THERE
 IS NOT SUCH A THING. REVISE AS REQUIRED. PROVIDE
 CORRECT INFORMATION. SEC. 107.2.1 CITY AMENDMENTS.
  
 B) THE ULTIMATE WIND LOAD INFORMATION IS NOT CLEAR.
 THERE IS ONE AREA THAT CALLS FOR 170 MPH ULTIMATE,
 WHILE AT THE BOTTOM OF DESIGN CRITERIA CALLS FOR 175
 MPH. REVISE AS REQUIRED. PROVIDE CLEAR INFORMATION.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 C) DESIGN CRITERIA AT THE BOTTOM REFERENCES THE FBC-10.
 NEED TO REFERENCE THE CURRENT 2014 BUILDING CODE AS
 REQUIRED BY CHAPTER 553 F.S.
  
 12- WINDOWS ON THE NEW WEST ELEVATION ARE LABELED AS
 INTERIOR ZONE WINDOWS. THIS IS INCORRECT. THEY ARE END
 ZONE WINDOWS. SAME THING APPLIES TO THE FIRST WINDOW OF
 BEDROOM #2 ON NEW SOUTH ELEVATION. REVISE AS REQUIRED.
 FIGURE R301.2(7) FBC-RESIDENTIAL.
 NOTE: REVISE PROPOSED FLOOR PLAN ALSO. LABEL THE
 WINDOWS CORRECTLY.
  
 *****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-20 Cont ID  
Sent By jgomez Date 2017-03-20 Time 09:09 Rev Time 0.00
Received By jgomez Date 2017-03-20 Time 07:43 Sent To  
Notes
2017-03-20 09:15:59 
 NOTE:
 PLAN REVIEW FEES ARE NOT PAID. REVIEW WILL BE PERFORMED
 WHEN THE FEES ARE PAID.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2017-10-27 Cont ID  
Sent By jpearson Date 2017-10-27 Time 08:39 Rev Time 0.00
Received By jpearson Date 2017-10-27 Time 08:39 Sent To  
Notes
2017-10-27 08:39:17CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL RISER DIAGRAM SHOWS A 1/0 WIRE FOR THE
 200 AMP PANEL. 1/0 WIRE IS NOT RATED FOR A 200 AMP
 SERVICE. PROVIDE CORRECTION. NEC 310.15(B)(7) AND
 (B)(15); FBC RE TABLE E3601.3
 2. ELECTRICAL RISER DIAGRAM SHOWS A # 6 GROUNDING
 ELECTRODE CONDUCTOR (GEC). BASED ON COMMENT # 1 AND THE
 INCREASED WIRE SIZE THAT WILL BE REQUIRED FOR THE
 SERVICE, THIS WIRE IS TOO SMALL. PROVIDE CORRECTION.
 NEC 250.66; FBC RE TABLE E3601.3
 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. NEC 250.94; FBC RE3609.3
 4. ELECTRICAL RISER DIAGRAM DOES NOT MATCH WHAT IS
 DRAWN ON PLAN. PLAN SHOWS A METER CAN, DISCONNECT, AND
 INTERIOR PANEL. RISER SHOWS A METER CAN AND MAIN
 BREAKER PANEL. CLARIFY AND/OR CORRECT. FBC 107.2.1; NEC
 215.5
 5. LOAD CALCULATION PROVIDED IS NOT CORRECT. LOAD
 CALCULATION IS MISSING SEVERAL ITEMS AND NOT PREPARED
 PROPERLY. SEE FBC RESIDENTIAL OR THE NEC FOR EXAMPLE.
 PROVIDE CORRECTED LOAD CALCULATION WITH ALL LOADS
 INCLUDED. NEC 220; FBC RE3602.3
 6. PANEL SCHEDULE CALLS FOR A 30 AMP BREAKER FOR WATER
 HEATER. BASED ON THE LOAD OF THIS UNIT STATED, THIS
 BREAKER IS TOO SMALL. PROVIDE ACCURATE OCP FOR THE
 TANKLESS WATER HEATER. NEC 110.3, 210.20, 240.4; FBC RE
 3705.5
 7. PANEL SCHEDULE SHOWS A WINDOW UNIT AC. PLAN SHOWS AN
 A/C UNIT WITH AHU. CLARIFY AND/OR CORRECT. PROVIDE ALL
 CIRCUITS AND LOADS IN PANEL SCHEDULE. FBC 107.2.1; NEC
 220; FBC RE 3602.3
 8. PANEL SCHEDULE SHOWS ONLY ONE LIGHTING CIRCUIT.
 BASED ON SQUARE FOOTAGE OF HOME, A MINIMUM OF 2
 LIGHTING CIRCUITS WOULD BE REQUIRED. ADDITIONALLY, THE
 2 SMALL APPLIANCE CIRCUITS REQUIRED ARE NOT SHOWN. SHOW
 ALL REQUIRED BRANCH CIRCUITS IN PANEL SCHEDULE AND LOAD
 CALCULATION. FBC 107.2.1; NEC 220; FBC RE 3602.3
 9. SHEET E-1 STATES THAT THIS IS A DEMO PLAN, BUT NEW
 WORK INSTALLED IS SHOWN. REMOVE CONFLICTING STATEMENT.
 FBC 107.2.1
 10. ELECTRICAL NOTE 3 STATES THAT RECEPTACLES SHALL BE
 TAMPER RESISTANT PER NEC 406.11. THIS CODE SECTION DOES
 NOT APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE
 CORRECTION. NEC 406.12; FBC RE4002.14
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-07-18 Cont ID  
Sent By jleahy Date 2017-07-18 Time 17:54 Rev Time 0.00
Received By jleahy Date 2017-07-18 Time 17:54 Sent To  
Notes
2017-07-18 17:58:22FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 RISER DIAGRAM SHOWS BARN PANEL?
  
 100A PANEL SCHEDULE IS WHICH BUILDING?
  
 100A PANEL SCHEDULE HAS SEVERAL LOADS EITHER UNDERSIZED
 ON BREAKER OR TOO LARGE OF A BREAKER.
  
 LOAD CALCULATION REQUIRED FOR 200A SERVICE.
  
 OUTLET SPACING ON FLOOR PLAN SHOWN DOES NOT MEET CODE.
  
 IF BARN WORK IS GOING ON WE NEED A FLOOR PLAN FOR
 BARN..
2017-07-13 14:41:51NEW DRAWINGS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-07-18 Cont ID  
Sent By jleahy Date 2017-03-06 Time 16:05 Rev Time 0.00
Received By jleahy Date 2017-03-06 Time 15:26 Sent To  
Notes
2017-03-06 16:09:54CHANGED PASS TO FAIL DUE TO RESUBMITTAL JLEAHY SEE
 COMMENTS FOR RESUBMITTAL
  
 IF BARN WORK IS GOING TO BE COMPLETED UNDER THIS PERMIT
 SUBMIT A BARN PLAN FOR REVIEW JLEAHY
2017-03-06 16:06:51NEEDS LOAD CALCULATION FOR THE 200A MAIN
 OUTLET SPACING NOT TO CODE.
 BARN NOT SHOWN ON DRAWINGS

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2017-10-26 Cont ID  
Sent By fmittner Date 2017-10-26 Time 09:53 Rev Time 0.00
Received By fmittner Date 2017-10-18 Time 15:13 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2017-07-11 Cont ID  
Sent By fmittner Date 2017-07-11 Time 09:04 Rev Time 0.00
Received By fmittner Date 2017-07-11 Time 09:04 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-05-30 Cont ID  
Sent By fmittner Date 2017-05-26 Time 10:21 Rev Time 0.00
Received By fmittner Date 2017-05-26 Time 10:21 Sent To  
Notes
2017-05-26 10:22:36FHM SPOKE TO NICK 5/26...SCHEDULED MEETING FOR 5/30 TO
 REVIEW PLANS AND CONCERNS. PERMIT ON HISTORIC DESK TO
 USE FOR MEETING.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2019-03-19 Cont ID  
Sent By jgomez Date 2019-03-19 Time 15:20 Rev Time 0.00
Received By jgomez Date 2019-03-12 Time 14:30 Sent To  
Notes
2019-03-13 14:31:02R30

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2017-11-01 Cont ID  
Sent By jgomez Date 2017-11-01 Time 12:42 Rev Time 0.00
Received By jgomez Date 2017-10-03 Time 14:48 Sent To  
Notes
2017-10-05 14:48:16R30

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-07-18 Cont ID  
Sent By jleahy Date 2017-07-18 Time 18:00 Rev Time 0.00
Received By jleahy Date 2017-06-29 Time 13:06 Sent To  
Notes
2017-06-30 13:06:29R25

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-05-30 Cont ID  
Sent By lmarchan Date 2017-05-30 Time 11:39 Rev Time 0.00
Received By lmarchan Date 2017-05-04 Time 10:24 Sent To  
Notes
2017-05-11 10:24:29RESUB ROUTED TO GJOHNSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-23 Cont ID  
Sent By jgomez Date 2017-03-23 Time 07:45 Rev Time 0.00
Received By jgomez Date 2017-03-21 Time 13:40 Sent To  
Notes
2017-03-21 13:40:39FEES PAID, GIVEN TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-20 Cont ID  
Sent By jgomez Date 2017-03-20 Time 09:16 Rev Time 0.00
Received By jgomez Date 2017-02-14 Time 11:48 Sent To  
Notes
2017-02-15 11:48:23R09

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status F Date 2017-11-01 Cont ID  
Sent By jgomez Date 2017-11-01 Time 13:24 Rev Time 0.00
Received By jgomez Date 2017-11-01 Time 13:24 Sent To  
Notes
2017-11-01 13:25:141- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY
 PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A
 PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM
 BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES
 ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2017-07-13 Cont ID  
Sent By jgomez Date 2017-07-13 Time 14:42 Rev Time 0.00
Received By jgomez Date 2017-07-13 Time 14:42 Sent To  
Notes
2017-07-13 14:43:011- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY
 PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A
 PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM
 BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES
 ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2017-05-23 Cont ID  
Sent By jgomez Date 2017-05-23 Time 16:13 Rev Time 0.00
Received By jgomez Date 2017-05-23 Time 16:13 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-03-22 Cont ID  
Sent By jgomez Date 2017-03-22 Time 19:17 Rev Time 0.00
Received By jgomez Date 2017-03-22 Time 19:17 Sent To  
Notes
2017-03-22 19:17:391- ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY
 PROPERTY APPRAISER THE PROPOSED UTILITY ROOM WAS A
 PORCH. AFTER PLANS ARE REVISED, BRING THEM TO PALM
 BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES
 ASSESSMENT. BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2019-03-19 Cont ID  
Sent By jgomez Date 2017-11-01 Time 09:29 Rev Time 0.00
Received By jgomez Date 2017-11-01 Time 09:29 Sent To  
Notes
2017-11-01 09:30:5903/19/19 CHANGED STATUS FROM "N" TO "F". APPLICATION
 WAS ABANDONED AND INVALID. SEC. 105.3.2 CITY
 AMENDMENTS.
  
  
  
  
 NO INFORMATION SUBMITTED. PROVIDE COMPLETE MECHANICAL
 PLAN AND EQUIPMENT SIZING CALCULATIONS UNDER A SEPARATE
 PERMIT. JG.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2017-07-13 Cont ID  
Sent By jgomez Date 2017-07-13 Time 14:53 Rev Time 0.00
Received By jgomez Date 2017-07-13 Time 14:53 Sent To  
Notes
2017-07-13 14:54:46RESIDENTIAL (R3) ALTERATION, THIRD MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- ORIGINAL COMMENT: PROVIDE EQUIPMENT SIZING
 CALCULATIONS AND A/C PLAN. SEC. R403.6 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-05-23 Cont ID  
Sent By jgomez Date 2017-05-23 Time 16:18 Rev Time 0.00
Received By jgomez Date 2017-05-23 Time 16:18 Sent To  
Notes
2017-05-23 16:19:58RESIDENTIAL (R3) ALTERATION, SECOND MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- ORIGINAL COMMENT: PROVIDE EQUIPMENT SIZING
 CALCULATIONS AND A/C PLAN. SEC. R403.6 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-03-23 Cont ID  
Sent By jgomez Date 2017-03-23 Time 07:21 Rev Time 0.00
Received By jgomez Date 2017-03-23 Time 07:13 Sent To  
Notes
2017-03-23 07:41:38RESIDENTIAL (R3) ALTERATION, MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- PROVIDE EQUIPMENT SIZING CALCULATIONS AND A/C PLAN.
 SEC. R403.6 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2017-10-17 Cont ID  
Sent By gjohnson Date 2017-10-17 Time 14:32 Rev Time 0.00
Received By gjohnson Date 2017-10-17 Time 14:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-07-18 Cont ID  
Sent By gjohnson Date 2017-07-18 Time 14:42 Rev Time 0.00
Received By gjohnson Date 2017-07-18 Time 09:55 Sent To  
Notes
2017-07-18 14:43:44PROVISO
  
 1. PROVIDE SANITARY RISER DIAGRAM THAT MATCHES FLOOR
 PLAN RISER SHOWS A TUB THE FLOOR PLAN SHOWS A TUB.
2017-07-13 14:43:28NEW DRAWINGS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-05-23 Cont ID  
Sent By gjohnson Date 2017-05-12 Time 12:24 Rev Time 0.00
Received By gjohnson Date 2017-05-12 Time 12:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-03-02 Cont ID  
Sent By gjohnson Date 2017-03-02 Time 16:45 Rev Time 0.00
Received By gjohnson Date 2017-03-02 Time 13:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2017-10-26 Cont ID  
Sent By fmittner Date 2017-10-26 Time 09:53 Rev Time 0.00
Received By fmittner Date 2017-10-26 Time 09:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-07-11 Cont ID  
Sent By fmittner Date 2017-07-11 Time 09:04 Rev Time 0.00
Received By fmittner Date 2017-07-11 Time 09:04 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-05-30 Cont ID  
Sent By fmittner Date 2017-05-30 Time 11:18 Rev Time 0.00
Received By fmittner Date 2017-05-30 Time 11:18 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved