Plan Review Details - Permit 17020285
Plan Review Stops For Permit 17020285 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2017-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-02 |
Time |
18:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-02 |
Time |
18:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-14 |
Time |
09:15 |
Sent To |
|
|
Notes |
2017-02-14 10:15:53 | E-MAIL FROM CONTRACTOR. WAITING FOR ENGINEERING. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-02-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-13 |
Time |
18:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-13 |
Time |
15:57 |
Sent To |
|
|
Notes |
2017-02-13 15:59:08 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014) | | | | 1- NEW FLAT ROOF FLORIDA PRODUCT APPROVAL FL1654-R19 | | SUBMITTED: | | SELECTED ASSEMBLY W52 DOESN'T MEET THE DESIGN PRESSURES | | FOR ALL ROOF ZONES. PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS (2 COPIES) AS REQUIRED BY NOTE #11 TO MEET | | THE DESIGN PRESSURES REQUIRED BY SEC. R301.1 | | FBC-RESIDENTIAL FOR THE CORNER AREAS. | | | | NOTE: THERE ARE TWO DIFFERENT TYPES OF ROOF PROPOSED | | FOR THIS PROJECT. THERE IS ONE INSULATED ROOF SYSTEM | | (W-52) AND ONE NON-INSULATED ROOF SYSTEM (W-106). THE | | INSULATED ROOF SYSTEM NEEDS THE RAS 117 CALCULATIONS TO | | MEET THE DESIGN PRESSURES FOR ROOF ZONE #3. ACCORDING | | TO TABLE R301.2(2) -RESIDENTIAL THE CORNER PRESSURES | | FOR CORNER AREA FOR A ONE STORY BUILDING IS -95.7PSF. | | THE NON-INSULATED ROOF SYSTEM (W-106) IS OK BECAUSE THE | | DESIGN PRESSURES ARE HIGH ENOUGH TO COVER ALL ROOF | | ZONES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-02-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-09 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-09 |
Time |
09:44 |
Sent To |
|
|
Notes |
2017-02-09 11:01:45 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014) | | | | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL16717-R3 | | SUBMITTED: | | SELECTED ASSEMBLIES W43 AND W-88 DON'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED AND SEALED | | RAS 117 CALCULATIONS (2 COPIES) AS REQUIRED BY NOTE #11 | | TO MEET THE DESIGN PRESSURES REQUIRED BY SEC. R301.1 | | FBC-RESIDENTIAL FOR PERIMETER AND CORNER AREAS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-03-02 |
Time |
18:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-03-02 |
Time |
12:54 |
Sent To |
|
|
Notes |
2017-03-02 12:55:06 | JGOMEZ'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-02-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-14 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-14 |
Time |
09:15 |
Sent To |
|
|
Notes |
2017-02-14 09:15:51 | E-MAIL RESPONSE FROM CONTRACTOR. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-02-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-13 |
Time |
18:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-13 |
Time |
15:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-02-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-09 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-07 |
Time |
14:45 |
Sent To |
|
|
Notes |
2017-02-07 14:45:48 | JGOMEZ |
|
|
|