Plan Review Stops For Permit 17020058 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-05-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-05-12 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-05-12 |
Time |
07:25 |
Sent To |
|
|
Notes |
2017-05-12 07:40:39 | ****PROVISO**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17020058 | | ADD: 550 OKEECHOBEE BLVD. SUITE # CU-2 | | CONT: BRANCH CONSTRUCTION | | TEL: 561-833-6206 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | SHEET 02-A SHOWS THE BREAKROOM DOOR # 06 DOES NOT | | COMPLY WITH 2014 ACCESS. CODE 404.2.4 MANEUVERING | | CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS AND | | GATES SHALL COMPLY WITH 404.2.4. MANEUVERING CLEARANCES | | SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE | | REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. | | | | 3RD REVIEW - APPLICANT HAS PROPOSED A RESOLUTION VIA | | EMAIL. THIS PERMIT IS ISSUED WITH PROVISO - REVISE | | SHEET 03-A AND OTHER AFFECTED SHEETS, BREAK ROOM 05 | | DOOR TO COMPLY WITH FBC A 404.2.4 PRIOR TO FINAL | | INSPECTION. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-04-25 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-04-25 |
Time |
15:09 |
Sent To |
|
|
Notes |
2017-04-25 15:33:37 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17020058 | | ADD: 550 OKEECHOBEE BLVD. SUITE # CU-2 | | CONT: BRANCH CONSTRUCTION | | TEL: 561-833-6206 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1-4) OK | | | | 5) SHEET 02-A SHOWS THE BREAKROOM DOOR # 06 DOES NOT | | COMPLY WITH 2014 ACCESS. CODE 404.2.4 MANEUVERING | | CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS AND | | GATES SHALL COMPLY WITH 404.2.4. MANEUVERING CLEARANCES | | SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE | | REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. | | | | 2ND REVIEW, THE BREAK ROOM DOOR LACKS THE REQUIRED 18" | | MANEUVERING CLEARANCE, PULL SIDE. | | | | 6-7) OK | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-02-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-02-03 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-02-03 |
Time |
14:36 |
Sent To |
|
|
Notes |
2017-02-03 16:13:32 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 17020058 | | ADD: 550 OKEECHOBEE BLVD. SUITE # CU-2 | | CONT: BRANCH CONSTRUCTION | | TEL: 561-833-6206 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: FRI. FEB. 03/ 2017 | | ACTION: DENIED | | | | 1) SHEET 01-A THE COVERSHEET LIST THIS BUILDING AS A | | BUILDING TYPE III-B. PLEASE NOTE THIS IS A 20 STORY | | HIGH RISE BUILDING. PLEASE CORRECT TO A MINIMUM | | BUILDING TYPE I-A CONSTRUCTION, SEE 2014 FBC-B TABLE | | 503. | | | | 2) SHEET 01-A THE COVERSHEET ALSO LIST THE OCCUPANCY | | TYPE AS A-2 ASSEMBLY AND B OCCUPANCY. THE OCCUPANCY | | TYPE PER SECTION 304.1 IS A B/ BUSINESS OCCUPANCY. | | | | 3) SHEET 01-A THE COVERSHEET ALSO LIST THE BUILDING | | FIRE PROTECTION AS UNPROTECTED / SPRINKLERED NEW | | SYSTEM. PLEASE PROVIDE THE MEANING OF UNPROTECTED. IN | | THE 2014 FBC-B TABLE 601 THE BUILDING ELEMENT TABLE | | REQUIRES ALL STRUCTURAL ELEMENTS TO BE FIRE RATED IN | | HOURS. | | | | 4) SHEET 01-A THE COVERSHEET ALSO LIST THE OCCUPANT | | LOAD AS 10 IN THE UPPER RIGHT HAND CORNER OF THE SHEET, | | BUT IN THE LOWER RIGHT CORNER OF THE SHEET THE HEADING | | OF BUILDING DATA AND A/C CALCULATIONS BOTH INDICATE THE | | SQUARE FOOTAGE OF THE TENANT SPACE AS 1,182 SQUARE | | FEET. 1,182/100= 12 OCCUPANTS TABLE 1004.1.2. | | | | 5) SHEET 02-A SHOWS THE BREAKROOM DOOR # 06 DOES NOT | | COMPLY WITH 2014 ACCESS. CODE 404.2.4 MANEUVERING | | CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS AND | | GATES SHALL COMPLY WITH 404.2.4. MANEUVERING CLEARANCES | | SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE | | REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. | | | | 6) SHEET 02/A DOES NOT SHOW COMPLIANCE FOR THE BREAK | | ROOM SINK, COMPLIANCE WITH 2014 ACCESS. CODE | | 606.3 HEIGHT. | | 606.2 CLEAR FLOOR SPACE. | | 606.4 FAUCETS. | | 606.5 EXPOSED PIPES AND SURFACES. | | | | 7) SHEET 02/A THE RECEPTION DESK DOES NOT INDICATE | | COMPLIANCE WITH 2014 FBC-ACCESS. CODE 902.3 HEIGHT. THE | | TOPS WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 | | INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-05-11 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-05-11 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-05-11 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-02-06 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2017-02-06 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2017-02-06 |
Time |
13:47 |
Sent To |
|
|
Notes |
2017-02-06 14:20:14 | TODAY I SPOKE W/DONNIE OF BRANCH CONSTRUCTION AND | | DISCUSSED THE MISSING SOW WINDOW AND SIGN OUTLETS. WE | | AGREED TO HAVE THE PLANS RED LINED AND THEY WILL BE | | ADDED IN THE FIELD. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-04-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-04-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-04-28 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-02-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-02-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-02-08 |
Time |
12:05 |
Sent To |
|
|
Notes |
2017-02-09 10:12:04 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) SHEET O2 A - THE RESTROOM DOOR OPENS INTO THE EXIT | | CORRIDOR. | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | EXISTING BUILDING. | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | WIDTH OF THE STAIR LANDING WHEN THE DOOR LEAF IS FULLY | | OPEN. | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | 2) SHEET O2 A - THERE IS A PIECE OF FURNITURE LOCATED | | IN FRONT OF A SET OF DOUBLE DOORS THAT ARE INDICATED AS | | OPEN. THOUGH THE OTHER SET OF DOORS ARE INDICATED AS | | THE EXIT DOORS, PLEASE INDICATE IF THESE WILL BE LOCKED | | AND CLEARLY MARKED AS NOT EXIT DOORS. | | | | PLEASE REVIEW, CLARIFY AAAAAND CORRECT. | | | | | | | | | | 3) SHEET O3 A - THERE IS AN EXIT SIGN IN THE CORRIDOR | | LEADING INTO TREATMENT ROOM 7; HOWEVER, THERE IS NO | | EXIT SIGN INDICATED ON SHEET E 1. | | | | HOWEVER, PER NFPA 101, CHAPTER 7, MEANS OF EGRESS - | | 7.5.2 IMPEDIMENTS TO EGRESS. SEE ALSO 7.1.9 AND | | 7.2.1.5. | | 7.5.2.1* ACCESS TO AN EXIT SHALL NOT BE THROUGH | | KITCHENS, STOREROOMS OTHER THAN AS PROVIDED IN CHAPTERS | | 36 AND 37, RESTROOMS, WORKROOMS, CLOSETS, BEDROOMS OR | | SIMILAR SPACES, OR OTHER ROOMS OR SPACES SUBJECT TO | | LOCKING, UNLESS PASSAGE THROUGH SUCH ROOMS OR SPACES IS | | PERMITTED FOR THE OCCUPANCY BY CHAPTER18, 19, 22, OR | | 23. | | | | TREATMENT ROOM 7 DOOR CAN NOT BE MARKED AS AN EXIT. | | | | PLEASE CORRECT SHEET O3 A AND ENSURE AN EXIT SIGN IS | | NOT PALCED ABOVE THAT DOOR. | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-05-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-05-12 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-05-12 |
Time |
07:25 |
Sent To |
|
|
Notes |
2017-05-12 07:42:00 | ACCEPTED RESUBMITTAL VIA EMAIL PER AGREEMENT W/OWNER | | PROVISO; REVISION REQUIRED | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-05-11 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-05-11 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-04-20 |
Time |
11:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-02-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-02-15 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-02-02 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2017-02-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-02-03 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-02-03 |
Time |
14:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-04-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-04-25 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-04-25 |
Time |
12:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-02-06 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-02-06 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-06 |
Time |
12:34 |
Sent To |
|
|
Notes |
2017-02-06 12:55:06 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17020058 | | 2/6/17 | | | | 1) PROVIDE A DUCT SMOKE DETECTOR IN THE RETURN AIR | | SYSTEM OF THE NEW HEAT PUMP- SECTION 606.2.1. | | | | 2) PROVIDE AN AUTOMATIC SHUTOFF DAMPER FOR THE O/A | | INTAKE DUCT- SECTION C403.2.4.4 FBC-14 ENERGY | | CONSERVATION. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-04-27 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-27 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-04-27 |
Time |
11:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-02-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-02-15 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-02-15 |
Time |
15:32 |
Sent To |
|
|
Notes |
2017-02-15 15:54:59 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. THE TOILET PAPER DISPENSER SHOW 0'-8' OFF THE FRONT | | OF TOILET IT SHALL BE 7 "- 9" MAXIMUM IN FRONT OF THE | | WATER CLOSET MEASURED TO THE CENTERLINE OF THE | | DISPENSER. PER 604.7 | | | | 2. GRAB BARS SHALL BE MEASURED FROM FINISHED FLOOR TO | | TOP OF THE GRIPPING SURFACE. PER FBC ACC 609.4 | | | | 3. SHOW CLEARANCE AROUND A WATER CLOSET SHALL BE 60 | | INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE | | WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM | | THE REAR WALL. PER FBC ACC 604.3.1 | | | | 4. SHOW CLEAR FLOOR SPACE FOR LAV 30" X 48". PER FBC | | ACC 606.2 | | | | 5. SHT P-2 THE DETAIL FOR THE WATER HEATER SHOWS T+P | | DRAIN AND PAN DRAIN TERMINATING ABOVE A MOP SINK THERE | | IS NO MOP SINK SHOWN ON PLAN PLEASE CLARIFY. PER WPB | | AMEND TO FBC 107.2.1 | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-05-08 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2017-05-08 |
Time |
16:25 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2017-05-08 |
Time |
15:50 |
Sent To |
|
|
Notes |
2017-05-08 16:26:57 | COUNTS AS 1,185 SF FEET OF OFFICE PER THE ARCHITECTS | | PLAN SUBMITTED AS PART OF THE MINOR PD AMENDMENT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-02-06 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2017-02-06 |
Time |
16:22 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2017-02-06 |
Time |
16:22 |
Sent To |
|
|
Notes |
2017-02-06 16:40:56 | FAILED | | | | 1) THE COMMERCIAL UNITS ON THE GROUND FLOOR OF THE | | CITYPLACE SOUTH TOWER WERE APPROVED FOR RETAIL | | COMMERCIAL USES, NOT OFFICE. PRIOR TO ZONING APPROVAL | | OF ANY PERMITS FOR OFFICE BUILD-OUT, THE SQUARE FOOTAGE | | WOULD FIRST NEED TO BE CONVERTED FROM RETAIL TO OFFICE | | ON THE CITYPLACE DRI USE CHART, BY THE APPROVAL OF A | | MINOR PLANNED DEVELOPMENT AMENDMENT. THE MINOR PLANNED | | DEVELOPMENT AMENDMENT APPLICATION IS AVAILABLE FOR THE | | CITY'S PLANNING DIVISION. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] |
|
|