Plan Review Details - Permit 17011146
Plan Review Stops For Permit 17011146 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2017-02-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-02-08 |
Time |
06:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-02-08 |
Time |
06:01 |
Sent To |
|
|
Notes |
2017-02-07 17:25:05 | | | ADVISORY: 2014 FBC-B 305.1.1 LIBRARY AND READING ROOMS | | THAT ARE FOR RELIGIOUS EDUCATIONAL ROOMS AND RELIGIOUS | | AUDITORIUMS, WHICH ARE ACCESSORY TO PLACES OF RELIGIOUS | | WORSHIP IN ACCORDANCE WITH SECTION 303.1.4 AND HAVE | | OCCUPANT LOADS OF LESS THAN 100, SHALL BE CLASSIFIED AS | | GROUP A-3 OCCUPANCIES. | | IF THE LIBRARY AND READING ROOM ARE TO BE USED FOR | | OTHER THAN RELIGIOUS TEACHING AND INSTRUCTION THEN THE | | ROOM WILL NEED TO BE RECLASSIFIED AS EDUCATIONAL AND A | | CHANGE OF OCCUPANCY. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-02-06 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2017-02-06 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2017-02-06 |
Time |
14:36 |
Sent To |
|
|
Notes |
2017-02-06 14:58:39 | ELECTRICAL REVIEW NOTES | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | PROJECT NAME: | | JOB ADDRESS: 515 PALM STREET | | DESCRIPTION: ADDITION ON EXISTING SPACE | | MASTER PERMIT: 17011146 | | | | BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS. | | ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF | | SUBMITTED CORRECTIONS. | | | | 1. THOUGH YOU ALLEGE NOT TO BE DOING ANY ELECTRICAL | | WORK, ON SHEET A1 YOU MENTION THE REMOVAL OF ALL | | ELECTRIC IN A WALL THAT IS TO BE DEMOLISHED. | | 2. THE EXISTING LIGHTING SHALL BE COMPLIANT WITH CODE | | REQUIREMENTS. A LIGHT DENSITY ALLOWANCE CHART AS | | PROVIDED IN FBC-EC 405.5.2. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2017-02-02 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-02-02 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-02-02 |
Time |
12:05 |
Sent To |
|
|
Notes |
2017-02-02 14:43:39 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: PARENTHESIS | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) FIRE INSPECTOR SHALL VERIFY FIRE ALARM AND FIRE | | SPRINKLER FUNCTION ON FIRE INSPECTION. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-02-08 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-02-08 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-01-30 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2017-02-07 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-02-07 |
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-02-06 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-02-06 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-06 |
Time |
13:47 |
Sent To |
|
|
Notes |
2017-02-06 13:54:52 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17011146 | | 2/6/17 | | | | 1) PLEASE PROVIDE A SCOPE OF WORK FOR MECHANICAL WITH | | CORRESPONDING DRAWINGS, DETAILS, AND SPECIFICATIONS. | | PLEASE INCLUDE: | | | | A) MINIMUM VENTILATION CALCULATIONS- TABLE 403.3 | | | | B) AC COOLING AND HEATING CALCULATIONS- C403.2.1 FBC-14 | | ENERGY CONSERVATION CODE | | | | C) ENERGY COMPLIANCE SUBMITTAL DOCUMENTS- C101.4.3 | | | | D) DUCTWORK LAYOUT PLANS AND DETAILS- SECTION 601.1 | | | | E) MECHANICAL EQUIPMENT SCHEDULES. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
|