Plan Review Details - Permit 17011047
Plan Review Stops For Permit 17011047
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-02-02 Cont ID  
Sent By rmcdouga Date 2017-02-02 Time 08:55 Rev Time 0.00
Received By rmcdouga Date 2017-02-02 Time 08:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-02-16 Cont ID  
Sent By rmcdouga Date 2017-02-16 Time 07:49 Rev Time 0.00
Received By rmcdouga Date 2017-02-16 Time 06:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-02-02 Cont ID  
Sent By rmcdouga Date 2017-02-02 Time 08:56 Rev Time 0.00
Received By rmcdouga Date 2017-02-02 Time 08:56 Sent To  
Notes
2017-02-02 09:10:59PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBCR-E3602.2 - SUBMIT ELECTRICAL LOAD CALCULATIONS
 FOR THE DWELLING TO SHOW THAT THE EXISTING SERVICE IS
 ADEQUATE FOR THE POOL HEATER AND OTHER POOL EQUIPMENT.
  
 2) FBCR-E4203.1.2 - PROVIDE AT LEAST ONE 125-VOLT, 15-
 OR 20-AMPERE RECEPTACLE A MINIMUM OF 6 FEET FROM BUT
 NOT MORE THAN 20 FEET FROM THE INSIDE WALL OF THE POOL.
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-02-02 Cont ID  
Sent By tklarge Date 2017-02-02 Time 06:53 Rev Time 0.00
Received By tklarge Date 2017-02-02 Time 06:53 Sent To  
Notes
2017-02-02 06:55:26THERE IS NO GAS ASSOCIATED WITH THIS PERMIT. THE HEATER
 IS A HEAT PUMP.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-02-16 Cont ID  
Sent By rmcdouga Date 2017-02-16 Time 07:49 Rev Time 0.00
Received By rmcdouga Date 2017-02-16 Time 06:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-02-16 Cont ID  
Sent By rmcdouga Date 2017-02-02 Time 06:55 Rev Time 0.00
Received By rmcdouga Date 2017-01-27 Time 15:48 Sent To  
Notes
2017-01-27 15:48:44ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-02-02 Cont ID  
Sent By tklarge Date 2017-02-02 Time 06:53 Rev Time 0.00
Received By tklarge Date 2017-02-02 Time 06:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-02-01 Cont ID  
Sent By njwira Date 2017-02-01 Time 11:05 Rev Time 0.00
Received By njwira Date 2017-01-30 Time 08:49 Sent To  
Notes
2017-02-01 11:06:032/1/17- PASSED
  
 FRONT SETBACK IS 25FT.
 POOL EQUIPMENT IS WITHIN REQUIRED SETBACKS
 POOL MEETS 5FT SIDE AND REAR SETBACKS.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  