Plan Review Details - Permit 17011004
Plan Review Stops For Permit 17011004
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-04-12 Cont ID  
Sent By jgomez Date 2017-04-12 Time 15:30 Rev Time 0.00
Received By jgomez Date 2017-04-12 Time 11:19 Sent To E
Notes
2017-04-12 11:25:35BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR EXTERIOR
 DOOR AS SHOWN ON PLANS.
 2- ENGINEER OF RECORD TO APPROVE IN WRITING ABOVE
 PRODUCT APPROVAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-02-01 Cont ID  
Sent By jgomez Date 2017-02-01 Time 11:37 Rev Time 0.00
Received By jgomez Date 2017-02-01 Time 10:51 Sent To  
Notes
2017-02-01 11:38:28RESIDENTIAL (R3) REVISION, BUILDING REVIEW COMMENTS.
 CODE; FBC 5TH EDITION (2014).
  
 1- PLANS SUBMITTED WERE REVISED. OWES $217.00 FOR
 REVISION FEES.
 NOTE: REVISION FEES APPLY EVERYTIME PLANS ARE REVISED
 TO ADDRESS COMMENTS.
  
 2- ORIGINAL APPROVED PLANS WERE SIGNED AND SEALED BY
 THE PROFESSIONAL ENGINEER ERIC F. TRILLAS. THIS IS THE
 ENGINEER OF RECORD FOR THIS PROJECT. PLANS NEED THE
 SEAL, SIGNATURE AND TITLE BLOCK OF THE ENGINEER OF
 RECORD AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE.
  
 3- NONE OF THE REVISED WINDOWS ON BEDROOM #2 COMPLY
 WITH THE EGRESS REQUIREMENTS OF SEC. R310
 FBC-RESIDENTIAL. APPROVED PLANS SPECIFIED BEDROOM
 WINDOW "P" AS 38" X 63" SINGLE HUNG WINDOW. PLANS WERE
 APPROVED BECAUSE THIS WINDOW WAS THE ONLY ONE THAT MET
 THE EGRESS REQUIREMENTS. REVISED PLANS DON'T SHOW ANY
 WINDOW THAT MEETS THE EGRESS REQUIREMENTS FOR BEDROOM
 #2. REVISE AS REQUIRED TO COMPLY WITH SEC. R310
 FBC-RESIDENTIAL.
 NOTE: ORIGINALLY THIS ROOM WAS A "DEN ROOM" AND THE
 ENTRY DOOR WAS LOCATED IN THIS ROOM. ENTRY DOOR WAS
 RELOCATED, THEREFORE THE NEW BEDROOM NEEDS TO COMPLY
 WITH THE EGRESS REQUIREMENTS.
  
 4- SHEET S3: ALL THE WINDOWS AND DOORS THAT ARE LOCATED
 WITHIN 4'-0" FROM THE CORNERS ARE CONSIDERED TO BE IN
 THE END ZONE. SOME WINDOWS ARE INCORRECTLY MARKED AS
 "A" FOR INTERIOR ZONE. REVISE INFORMATION ON EXTERIOR
 ELEVATIONS TO IDENTIFY ALL THE WINDOWS AND DOORS THAT
 ARE IN THE END ZONE. FIGURE R301.2(7) FBC-RESIDENTIAL.
  
 5- BUILDING REVIEW WAS APPROVED ON 04/07/16 WITH THE
 FOLLOWING PROVISO:
 BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR WINDOWS,
 WINDOW MULLIONS AND EXTERIOR DOOR.
  
 ONLY THE SINGLE HUNG PRODUCT APPROVAL WAS SUBMITTED UP
 TO THIS TIME. NEED PRODUCT APPROVAL (2 COPIES) FOR THE
 WINDOW MULLIONS AND EXTERIOR DOOR.
  
 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS,
 INCLUDING SINGLE HUNG WINDOWS AS REQUIRED BY SEC.
 107.3.4.1 CITY AMENDMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
2017-01-26 17:21:39JGOMEZ

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-04-13 Cont ID  
Sent By vperez Date 2017-04-13 Time 10:31 Rev Time 0.00
Received By vperez Date 2017-04-13 Time 10:31 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2017-04-05 Cont ID  
Sent By fmittner Date 2017-04-05 Time 13:43 Rev Time 0.00
Received By fmittner Date 2017-04-05 Time 13:43 Sent To B
Notes
2017-03-23 08:37:55ROUTED TO FREDERIKE MITTNER

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-01-30 Cont ID  
Sent By jgomez Date 2017-02-01 Time 11:38 Rev Time 0.00
Received By fmittner Date 2017-01-30 Time 14:17 Sent To  
Notes
2017-01-30 14:18:16CLEAR GLASS ON FRONT/SIDE WINDOWS.
2017-01-30 10:29:10ROUTED TO FREDERIKE MITTNER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-04-13 Cont ID  
Sent By gjohnson Date 2017-04-13 Time 11:14 Rev Time 0.00
Received By gjohnson Date 2017-03-21 Time 14:39 Sent To  
Notes
2017-03-22 14:39:23REVISION RESUB ROUTED TO FMITTNER VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-02-01 Cont ID  
Sent By jgomez Date 2017-02-01 Time 11:37 Rev Time 0.00
Received By jgomez Date 2017-01-26 Time 17:21 Sent To HIST
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-04-13 Cont ID  
Sent By jgomez Date 2017-04-12 Time 16:30 Rev Time 0.00
Received By gjohnson Date 2017-04-13 Time 11:14 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved