Plan Review Stops For Permit 17010899 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-04-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-04-11 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-04-11 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-23 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-23 |
Time |
14:00 |
Sent To |
|
|
Notes |
2017-02-23 14:10:29 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SELECT WHICH PRODUCT WILL BE INSTALLED FROM PRODUCT | | APPROVALS SUBMITTED. IF NON-IMPACT RATED DEVICES ARE | | SELECTED, PROVIDE SHUTTER SCHEDULE WITH PRODUCT | | APPROVALS. | | 2. PRODUCT APPROVALS TO BE REVIEWED AND APPROVED BY | | DESIGNER. | | 3. YOU MAY PROVIDE A DOOR AND WINDOW SCHEDULE WITH | | LOCATIONS ON PLANS FOR EACH DEVICE, ROUGH OPENINGS, | | DESIGN WIND LOADS AND PRODUCT APPROVAL NUMBER. | | 4. ROOFING PERMIT REQUIRED. | | 5. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM | | COMPONENTS. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | SUCH DRAWINGS AND SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING, | | WINDOW, AND DOOR SUBMITTALS. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-04-04 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-04-04 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-04-04 |
Time |
08:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-02-15 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-15 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-15 |
Time |
08:12 |
Sent To |
B |
|
Notes |
2017-02-15 08:21:59 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA RES BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 | | COMMENTS: | | | | 1. PROVIDE AIC CALCULATIONS FOR NEW SERVICE SHOWN. FBC | | 107.3.5 | | 2. GENERAL NOTE TO INDICATED REQUIRED SEPARATE PERMITS | | FOR LOW VOLTAGE SYSTEMS. FBC 107.3.5 | | 3. SHOW AN INTERSYSTEM BONDING TERMINAL AT THE SERVICE | | PER FBC RES E3609.3 | | 4. PLEASE ADDRESS WALL SPACE RECEPTACLE REQUIREMENTS | | PER FBC RES E3901.2.2, 1. ANY SPACE THAT IS 2FT OR MORE | | IN WIDTH. SEE BEDROOM WALLS ADJACENT TO NEW CLOSET. | | 5. SHOW A RECEPTACLE W/P GFCI PROTECTED AT THE HVAC AC | | LOCATION FOR SERVICE PER FBC RES E3901.12 HVAC OUTLET | | 6. PROVIDE A NOTE PER FBC ENERGY CONSERVATION CODE TO | | INDICATE; 75% OF LAMPS TO HIGH EFFICACY LAMPS. | | 7. PLEASE SHOW ON PANELBOARD 20A CIRCUITS REQUIRED FOR | | LAUNDRY ROOM 1500VA. FBC RES E3703.2 AND 4 | | 8. ARC FAULT REQUIMENTS SHALL APPLY TO ALL AREAS AS | | NOTED ON FBC RES E3902.12 | | 9. UPDATE ALL CODE REFERENCES TO NEC 2011 NOT 2005. SEE | | ABOVE CODES IN EFFECT. | | 10. PROVIDE A NOTE TO COMPLY WITH TAMPER RESISTANT | | RECEPTACLES PER FBC RES 4002.14 | | 11. FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | QUESTIONS OR CONCERNS. | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-04-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-12 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-24 |
Time |
13:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-23 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-01-25 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-04-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-12 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-04-12 |
Time |
15:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-02-14 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-02-14 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-02-14 |
Time |
14:49 |
Sent To |
|
|
Notes |
2017-02-14 15:26:43 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. THE RISER DIAGRAM SHOWS A SHOWER THE PLAN VIEWS | | SHOWS A TUB PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | | | 2. IS WATER HEATER EXISTING OR WILL IT BE NEW PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 3. THE BRANCH DRAIN FOR KITCHEN CAN NOT CONNECT TO | | CLEAN OUT IT SHALL CONNECT TO BUILDING DRAIN UPSTREAM | | OF CLEAN OUT. PER FBC RES P3005.2.11 | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
N |
Date |
2017-04-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-04-11 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-04-11 |
Time |
15:24 |
Sent To |
|
|
Notes |
2017-04-11 15:25:11 | ROOFING PREVIOUSLY COMPLETE. NOT PART OF THIS SOW. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-23 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-23 |
Time |
14:10 |
Sent To |
|
|
Notes |
2017-02-23 14:13:14 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING | | SUBMITTALS. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-03-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2017-03-28 |
Time |
14:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-02-09 |
|
|
Cont ID |
|
Sent By |
pgreilic |
Date |
2017-02-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2017-02-09 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|