Plan Review Stops For Permit 17010898 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-01-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-23 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-23 |
Time |
16:38 |
Sent To |
M |
|
Notes |
2018-01-23 16:39:02 | ROOFING PERMIT 17100750 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-12-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-22 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-22 |
Time |
13:34 |
Sent To |
|
|
Notes |
2017-12-22 14:59:34 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOF MSYSTEM. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-08-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-08-21 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-08-21 |
Time |
16:12 |
Sent To |
P |
|
Notes |
2017-08-21 16:33:14 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. MECHANICAL PLAN REQUIRED. PROVIDE ENERGY SUBMITTAL. | | 2. ROOFING PERMIT REQUIRED. PROVIDE PRODUCT APPROVALS | | FOR NEW ROOFING SYSTEM. | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | _ OR _ | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | SUBMITTALS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-23 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-23 |
Time |
14:37 |
Sent To |
|
|
Notes |
2017-02-23 14:43:21 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SELECT WHICH PRODUCT WILL BE INSTALLED FROM PRODUCT | | APPROVALS SUBMITTED. IF NON-IMPACT DEVICES ARE | | SELECTED, PROVIDE SHUTTER SCHEDULE WITH PRODUCT | | APPROVALS. | | 2. PRODUCT APPROVALS TO BE REVIEWED AND APPROVED BY | | DESIGNER. | | 3. YOU MAY PROVIDE A DOOR AND WINDOW SCHEDULE WITH | | LOCATIONS ON PLANS FOR EACH DEVICE, ROUGH OPENINGS, | | DESIGN WIND LOADS AND PRODUCT APPROVAL NUMBER. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | SUCH DRAWINGS AND SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW, AND | | DOOR SUBMITTALS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-12-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-12-07 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-12-07 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-08-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-08-14 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-08-14 |
Time |
17:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-02-02 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-02-02 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2017-02-02 |
Time |
10:56 |
Sent To |
|
|
Notes |
2017-02-02 14:41:47 | 1ST REVIEW | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | 1] CORRECT ELECTRICAL NOTE TO THE CURRENT APPPLICABLE | | CODE NEC 2011 ( FBC-R 2014 ) | | | | 2] AFCI PROTECTION ISN'T LIMITED TO THE BEDROOMS BUT IN | | ACCORDANCE NEC 210.12(B) ( FBC-R E3902.13 ) SEE | | PROVISIONS. | | | | 3] PROVIDE A GFCI SERVICE RECEPTACLE OUTLET WITHIN 25' | | OF THE C/U. NEC 210.63 ( FBC-R E3901.11 ) | | | | 4] ADD A NOTE THAT 75% OF LUMINAIRES SHALL BE HIGH | | EFFICIENT PER FBC-E R404.1. | | | | 5] THE MAIN DISCONNECT SHALL BE FUSIBLE FOR | | OVER-CURRENT PROTECTION PER NEC 230.90 ( FBC-R E3606.3 | | ). | | | | 6] WASHER ( LAUNDRY) CIRCUIT SHALL BE INCLUDED IN LOAD | | CALCS IN ACCORDANCE WITH NEC 220.52(B) ( FBC-R E3704.2 | | ). | | | | 7] SHOW DRYER BREAKER & WIRE SIZE ON PANEL SCHEDULE. | | FBC 107 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-12-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-22 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-01 |
Time |
12:42 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-08-22 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-08-08 |
Time |
11:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-23 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-01-25 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
N |
Date |
2018-01-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-01-24 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-01-24 |
Time |
08:17 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-12-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-12-22 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-12-22 |
Time |
12:28 |
Sent To |
|
|
Notes |
2017-12-22 12:33:04 | 3RD REVIEW FBC-2014 RESIDENTIAL. | | PERMIT #17010898 | | 8/17/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | SOME OF THE 1ST REVIEW COMMENTS STILL EXIST. I HAVE | | REPRINTED THEM BELOW WITH ADDITIONAL COMMENTS AND | | CLARIFICATIONS. | | | | 1) PROVIDE A SCOPE OF WORK FOR MECHANICAL ALTERATIONS | | WITH CORRESPONDING DRAWINGS AND DETAILS ON THE PLAN. | | | | NEW COMMENT: THE REVISED PLAN IS INDICATING A REPLACED | | AIR HANDLER. PLEASE PROVIDE ON THE PLAN AN AC EQUIPMENT | | SCHEDULE THAT INCLUDES THE AIR HANDLER AND THE | | CONDENSER, AND SUBMIT AN AHRI CERTIFICATE FOR THE | | SYSTEM- SECTION R101.4.7 FBC-14 ENERGY CONSERVATION. | | | | NEW COMMENT: THE LOCATION OF THE AIR HANDLER APPEARS TO | | HAVE CHANGED. PLEASE SHOW ALL ALTERATIONS TO THE | | EXISTING SUPPLY AND RETURN SYSTEM, AND INDICATE THE | | REQUIRED CLEARANCES FOR THE AIR HANDLER IN THE CLOSET | | AS REQUIRED BY SECTION M1305.1.1. | | | | NEW COMMENT: THE LOCATION OF THE CONDENSER APPEARS TO | | HAVE CHANGED. PLEASE PROVIDE STRUCTURAL DETAILS FOR | | INSTALLATION OF THE PAD AND MOUNTING OF THE CONDENSER | | TO THE PAD- SECTION M1305.1.4.1 & M1307.2 FBC-14 | | RESIDENTIAL. | | | | 2) SUBMIT DOCUMENTATION OF ENERGY CONSERVATION | | COMPLIANCE AS REQUIRED BY SECTIONS R101.4.3, R101.5.1 | | FBC-14 ENERGY CONSERVATION CODE. | | | | 3) SUBMIT TWO COPIES OF WPB BUILDING DEPARTMENT AC | | CHANGE OUT FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-08-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-08-17 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-08-17 |
Time |
16:27 |
Sent To |
|
|
Notes |
2017-08-17 16:51:34 | 2ND REVIEW FBC-2014 RESIDENTIAL. | | PERMIT #17010898 | | 8/17/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | SOME OF THE 1ST REVIEW COMMENTS STILL EXIST. I HAVE | | REPRINTED THEM BELOW WITH ADDITIONAL COMMENTS AND | | CLARIFICATIONS. | | | | 1) PROVIDE A SCOPE OF WORK FOR MECHANICAL ALTERATIONS | | WITH CORRESPONDING DRAWINGS AND DETAILS ON THE PLAN. | | | | NEW COMMENT: THE REVISED PLAN IS INDICATING A REPLACED | | AIR HANDLER. PLEASE PROVIDE ON THE PLAN AN AC EQUIPMENT | | SCHEDULE THAT INCLUDES THE AIR HANDLER AND THE | | CONDENSER, AND SUBMIT AN AHRI CERTIFICATE FOR THE | | SYSTEM- SECTION R101.4.7 FBC-14 ENERGY CONSERVATION. | | | | NEW COMMENT: THE LOCATION OF THE AIR HANDLER APPEARS TO | | HAVE CHANGED. PLEASE SHOW ALL ALTERATIONS TO THE | | EXISTING SUPPLY AND RETURN SYSTEM, AND INDICATE THE | | REQUIRED CLEARANCES FOR THE AIR HANDLER IN THE CLOSET | | AS REQUIRED BY SECTION M1305.1.1. | | | | NEW COMMENT: THE LOCATION OF THE CONDENSER APPEARS TO | | HAVE CHANGED. PLEASE PROVIDE STRUCTURAL DETAILS FOR | | INSTALLATION OF THE PAD AND MOUNTING OF THE CONDENSER | | TO THE PAD- SECTION M1305.1.4.1 & M1307.2 FBC-14 | | RESIDENTIAL. | | | | 2) SUBMIT DOCUMENTATION OF ENERGY CONSERVATION | | COMPLIANCE AS REQUIRED BY SECTIONS R101.4.3, R101.5.1 | | FBC-14 ENERGY CONSERVATION CODE. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-02-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-02-09 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-09 |
Time |
07:24 |
Sent To |
B |
|
Notes |
2017-02-09 07:43:44 | 1ST REVIEW FBC-2014 RESIDENTIAL. | | PERMIT #17010898 | | 2/9/17 | | | | 1) PROVIDE A SCOPE OF WORK FOR MECHANICAL ALTERATIONS | | WITH CORRESPONDING DRAWINGS AND DETAILS ON THE PLAN. | | CLARIFY IF THE EXISTING AC SYSTEM WILL BE REPLACED OR | | ALTERED AS PART OF THE RENOVATION. | | | | 2) INDICATE HOW THE BATHROOMS WILL BE VENTILATED USING | | EITHER OPERABLE OPENINGS TO THE OUTDOORS PER SECTION | | R303.3, OR MECHANICALLY PER M1507.4. | | | | 3) PROVIDE EXHAUST VENTILATION FOR THE KITCHEN- SEE | | SECTIONS M1503- M1507 FOR COMPLIANCE METHODS. | | | | 4) THE PLAN INDICATES A FIREPLACE THAT APPEARS TO BE A | | NEW INSTALLATION. PLEASE PROVIDE AN EQUIPMENT SCHEDULE | | ON THE PLAN THAT LISTS THE MAKE AND MODEL OF THE UNIT, | | AND TYPE- GAS-FIRED, WOOD BURNING, ELECTRIC ETC. A) | | SUBMIT MANUIFACTURER'S SPECIFICATIONS FOR THE UNIT AND | | THE VENT SYSTEM. B) PROVIDE A VENTING DIAGRAM THAT | | INDICATES THE TYPE AND SIZE OF VENT MATERIAL, LENGTH OF | | VENT | | | | RUN AND LOCATION OF VENT TERMIANTION CAP. | | | | 5) SUBMIT DOCUMENTATION OF ENERGY CONSERVATION | | COMPLIANCE AS REQUIRED BY SECTIONS R101.4.3, R101.5.1 | | FBC-14 ENERGY CONSERVATION CODE. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-12-19 |
Time |
19:00 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-12-19 |
Time |
14:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-08-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-08-22 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-08-22 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-02-02 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-02-02 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-02-02 |
Time |
15:27 |
Sent To |
|
|
Notes |
2017-02-02 17:02:08 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. IT IS UNCLEAR WHICH BATHROOM IS BEING REPLACED THE | | BATH ON THE RISER NEXT TO THE WASHER SHOWS A TUB BUT | | THE FLOW PLAN SHOWS A TUB NEXT TO WASHER PLEASE CLARIFY | | WHAT WORK IS BEING DONE IN EACH BATHROOM. PER WPB AMEND | | TO FBC 107.2.1 | | | | 2. IS THE WATER HEATER EXISTING TO REMAIN OR WILL IT BE | | REPLACED. PER WPB AMEND TO FBC 107.2.1 | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|