Plan Review Details - Permit 17010396
Plan Review Stops For Permit 17010396 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-01-27 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-01-27 |
Time |
10:16 |
Sent To |
|
|
Notes |
2017-01-27 11:08:08 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL, EXISTING | | BUILDING CODE | | | | THIS IS A REVIEW FOR RE-ISSUANCE OF EXPIRED PERMIT | | 05110768. THE PROJECT WAS COMPLETED BUT ALL REQUIRED | | INSPECTIONS WERE NOT APPROVED. SEE R REVIEW FOR ROOF | | COVERING REQUIREMENTS AND ELECTRIC REVIEW FOR | | ELECTRICAL REQUIREMNTS. THERE IS NO RECORD OF A | | REQUIRED INSULATION INSPECTION. YOU MUST SATISFY THE | | INSPECTOR BY CERTIFICATION TEST OR EXPOSING THE WORK | | SUFFICIENTLY TO VERIFY THE INSTALLATION. REF. FBC 110. | | PLEASE NOTE THE PLAN SHOW AN EXTERIOR HARDIPLANK | | SIDING, HOWEVER UNDER PERMIT 07070773, A CHANGE WAS | | MADE TO STUCCO AND THAT PERMIT RECEIVED THE REQUIRED | | INSPECTIONS. THIS IS NOTED ON THE PLAN FOR RECORD | | PURPOSES. PLEASE NOTE THE OWNER INDICATES THE STORM | | PANELS ON FILE FROM THE ORIGINAL PERMIT DOCUMENTS ARE | | NOT PROVIDED ON SITE. ACCORDINGLY, A LICENSED | | CONTRACTOR MUST BE ENGAGED BY THE OWNER AND A SEPARATE | | PERMIT MUST BE OBTAINED TO INSTALL NEW CODE COMPLIANT | | SHUTTERS FOR THE NEW WINDOW OPENINGS ON THE EXTERIOR | | WALLS SHOWN ON THE RECORD SET OF PLANS 05110768. REF | | FBC R301.2.1.2 PROTECTION OF OPENINGS AND FS 489.103. A | | FINAL INSPECTION WAS NEVER SCHEDULED AND IS REQUIRED | | HOWEVER, IT MAY NOT BE SCHEDULED UNTIL SUCH TIME AS THE | | HURRICANE PANEL, ELECTRICAL AND ROOFING PERRMITS ARE | | COMPLETED AND HAVE RECEIVED FINAL APPROVED INSPECTIONS. | | . | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-01-27 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-01-27 |
Time |
09:47 |
Sent To |
|
|
Notes |
2017-01-27 10:08:21 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL EXISTING | | BUILDING CODE | | | | PROVISIONALLY APPROVED. RECORDS ON FILE FOR PERMIT | | NUMBER 06091033 SHOW THE ROUGH INSPECTION PASSED BUT | | THE FINAL INSPECTION WAS NEVER SCHEDULED. THE WORK WAS | | COMPLETED. THE INSPECTOR MAY REQUIRE THE ADDITION OF | | SMOKE DETECTOR IF NOT EXISTING. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-01-27 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-01-12 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-01-27 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-01-27 |
Time |
10:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-01-27 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-01-27 |
Time |
10:08 |
Sent To |
|
|
Notes |
2017-01-27 10:16:12 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL EXISTING | | BUILDING | | | | THE ORIGINAL PERMIT DOCUMENTS FOR 05110768 DID NOT | | CONTAIN PRODUCT INFORMATION FOR THE ROOF COVERING. | | DISCUSSION WITH THE OWNER INDICATES THE ROOF COVERING | | INSTALLED FOR THE ADDITION IS IN POOR CONDITION. | | ACCORDINGLY, A LICENSED ROOFING CONTRACTOR IS REQUIRED | | TO SIGN ON THIS APPLICATION AS THE OWNER BUILDER IS | | SELLING THE PROPERTY, AND A ROOFING SUBMITTAL FOR A NEW | | ROOF IS REQUIRED TO BE PROVIDED FOR REVIEW AND | | COMPLIANCE WITH APPLICABLE CRITERIA. REFERENCE FS | | 489.103 AND FBC 107. | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
|