Plan Review Details - Permit 17010361
Plan Review Stops For Permit 17010361
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-03-10 Cont ID  
Sent By cthroop Date 2017-03-10 Time 15:13 Rev Time 0.00
Received By cthroop Date 2017-03-10 Time 15:09 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-02-01 Cont ID  
Sent By cthroop Date 2017-02-01 Time 14:37 Rev Time 0.00
Received By cthroop Date 2017-02-01 Time 14:37 Sent To  
Notes
2017-02-01 14:53:26BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE COPY OF EXISTING FLOOR PLAN. IDENTIFY EACH
 ROOM.
 2. PROVIDE COPY OF PROPOSED FLOOR PLAN, SHOW LOCATION
 OF PROPOSED NEW BATH.
 3. NEW WOOD FRAMED WALL INSULATION SHALL BE A MINIMUM
 OF R-13 PER TABLE R402.1.1
 4. PROVIDE PRODUCT APPROVALS FOR NEW WINDOW.
 5. PROVIDE MANUFACTURER'S SPECIFICATIONS FOR PROPOSED
 DUROCK. DEMONSTRATE DUROCK IS AN APPROVED SUBSTRATE FOR
 THE APPLICATION OF PORTLAND CEMENT BASED WALL VENEER.
 (STUCCO)
 6. PARTIAL FLOOR PLAN IDENTIFIES EXISTING DOOR AS 3" X
 6". PLEASE CLARIFY.
 7. PROVIDE ATTACHMENT DETAIL AND FASTENER SCHEDULE FOR
 NEW WOOD WALL TO EXISTING 8" CMU WALL.
  
 FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION
 PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL
 FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING
 DIMENSIONS; AND ALL EXTERIOR ELEVATIONS:
  
 TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS
 BY COMPONENT
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW
 SUBMITTALS.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-03-20 Cont ID  
Sent By vperez Date 2017-03-20 Time 09:31 Rev Time 0.00
Received By vperez Date 2017-03-20 Time 09:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-20 Cont ID  
Sent By vperez Date 2017-03-20 Time 09:31 Rev Time 0.00
Received By vperez Date 2017-03-20 Time 09:31 Sent To  
Notes
2017-03-09 10:00:53RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-02-01 Cont ID  
Sent By cthroop Date 2017-02-01 Time 14:37 Rev Time 0.00
Received By cthroop Date 2017-01-11 Time 10:03 Sent To  
Notes
2017-01-12 10:03:16BLDG MISC 1

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2017-03-20 Cont ID  
Sent By hmoser Date 2017-03-20 Time 09:08 Rev Time 0.00
Received By hmoser Date 2017-03-20 Time 08:40 Sent To E
Notes
2017-03-20 09:09:53NO MECHANICAL REQUIRED AT THIS TIME.HM.

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-03-16 Cont ID  
Sent By gjohnson Date 2017-03-16 Time 10:36 Rev Time 0.00
Received By gjohnson Date 2017-03-16 Time 10:36 Sent To  
Notes
***NONE***