Plan Review Stops For Permit 17010155 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2017-01-18 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-18 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2017-01-18 |
Time |
14:41 |
Sent To |
|
|
Notes |
2017-01-18 15:10:45 | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | 1] ELECTRICAL REVIEW UNDER 16120490 | | | | 2] CONDENSER UNIT REQUIRESA SERVICE GFCI RECEPTACLE | | OUTLET WITHIN 25' OF EQUIPMENT PER FBC-R SEC E3901.11 | | (PROVISO COMMENT) | | | | 3] PROVIDE A DISCONNECT WITHIN SIGHT OF THE CONDENSER | | UNIT PER FBC-R SEC E4101.5 (PROVISO COMMENT) |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-03-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-03-09 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-03-09 |
Time |
09:36 |
Sent To |
|
|
Notes |
2017-03-09 09:36:19 | RESUB ROUTED TO HMOSER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-03-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-03-07 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-03-01 |
Time |
10:45 |
Sent To |
|
|
Notes |
2017-03-02 10:45:44 | RESUB ROUTED TO JVALIDO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-02-15 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-02-15 |
Time |
07:47 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-02-07 |
Time |
11:24 |
Sent To |
|
|
Notes |
2017-02-08 11:24:18 | RESUB ROUTED TO JVALIDO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-01-18 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-18 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2017-01-06 |
Time |
16:33 |
Sent To |
|
|
Notes |
2017-01-06 16:33:18 | ROUTED TO MECHANICAL INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-03-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-03-09 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-03-09 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-03-06 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2017-03-06 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2017-03-06 |
Time |
16:18 |
Sent To |
|
|
Notes |
2017-03-06 17:24:46 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | (1) TOTAL CFM OF SUPPLY OUTLETS ON PLANS IS MORE THAN | | MANUFACTURER SPECIFICATIONS PER 39500 BTUH. (I WILL | | PROVIDE DATA FROM MANUFACTURE ON EMAIL) | | | | FLORIDA ENERGY CODE FBC 2014 | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-02-14 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2017-02-14 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2017-02-14 |
Time |
16:50 |
Sent To |
|
|
Notes |
2017-02-14 17:02:26 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | (1) PROVIDE BALANCED RETURN FROM ALL BEDROOMS. | | (2) PROVIDE ORIGINAL ENGINEER OR ARCHITECT SIGNATURE | | AND SEAL. | | (3) TOTAL CFM FOR ALL SUPPLY GRILLS ARE MORE THAN TOTAL | | CFM AHU CAN SUPPLY. CONFIRM CORRECT CFM AND MAKE | | CORRECTIONS. | | (4) VENTILATION, A/C, HEAT IN OFFICE ????? | | | | FLORIDA ENERGY CODE FBC 2014 | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-01-10 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2017-01-10 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2017-01-10 |
Time |
16:18 |
Sent To |
E |
|
Notes |
2017-01-10 17:21:57 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | (1) PROVIDE INFORMATION ON PLANS. ENGINEER OR ARCHITECT | | STAMP AND SIGNATURE. (AS PER 107.1 GENERAL) SEE BELOW | | | | 107.1 GENERAL. | | IF THE DESIGN PROFESSIONAL IS AN ARCHITECT, INTERIOR | | DESIGNER, LANDSCAPE ARCHITECT, OR ENGINEER LEGALLY | | REGISTERED UNDER THE LAWS OF THIS STATE REGULATING THE | | PRACTICE OF ARCHITECTURE OR INTERIOR DESIGN AS | | PROVIDED FOR IN CHAPTER 481, FLORIDA STATUTES, PART I, | | OR LANDSCAPE ARCHITECTURE AS PROVIDED FOR IN | | CHAPTER 481, FLORIDA STATUTES, PART II, OR ENGINEERING | | AS PROVIDED FOR IN CHAPTER 471, FLORIDA | | STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | OFFICIAL SEAL TO SAID DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA, AS REQUIRED BY FLORIDA STATUTE. | | | | (2) PROVIDE EQUIPMENT SCHEDULE ON PLANS. ( BRAND, AHU | | MODEL #, CONDENSER MODEL #, TOTAL BTUH, KW HEATER, | | SEER) | | (3) PROVIDE BALANCE RETURN FROM ALL HABITABLE ROOMS (AS | | PER M1602.4 BALANCED RETURN AIR) | | (4) PROVIDE EXHAUST IN ALL BATHROOMS. (MINIMUN 50 CFM) | | (5) KITCHEN EXHAUST ????? | | (6) PROVIDE CONDENSER TIE DOWN DETAIL. (AS PER | | MANUFACTURER, IF APPLICABLE) | | | | FLORIDA ENERGY CODE FBC 2014 | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | | | | | | | |
|
|