Plan Review Details - Permit 16120880
Plan Review Stops For Permit 16120880 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-02-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2018-02-22 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2018-02-21 |
Time |
11:01 |
Sent To |
|
|
Notes |
2018-02-22 11:07:34 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16120880 | | ADD: 1989 LACE LEAF COURT / TENNIS CENTER BUILDING | | CONT: MEP CONSTRUCTION GROUP | | TEL: 201-563-1098 STEPHEN KATZ | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION. | | | | 4TH REVIEW | | DATE: THURS. FEB. 22/ 2018 | | ACTION: BUILDING PROVISO | | | | 1) BUILDING PROVISO: THE ORGANICS FOUND AT BORINGS B-1, | | THROUGH B-3 FROM 6 FEET TO 12 FEET BELOW GRADE AND IN | | STRUCTURAL AREAS SHOULD BE REMOVED AND REPLACED WITH | | GOOD QUALITY FILL ACCORDING TO THE SPECIFICATIONS AND | | PROCEDURES OUTLINED IN THE SITE PREPARATION SECTION OF | | THIS REPORT. THE REMOVAL OF ORGANIC SOILS FROM THE SITE | | SHOULD BE PERFORMED UNDER THE FULL-TIME OBSERVATION OF | | A SOILS ENGINEER REPRESENTATIVE TO DOCUMENT AND ENSURE | | THAT ORGANIC SOIL AND OTHER UNSUITABLE MATERIALS HAVE | | BEEN COMPLETELY REMOVED AND PROPERLY REPLACED WITH | | COMPACTED, SUITABLE STRUCTURAL FILL MATERIAL. | | | | 2) BUILDING PROVISO, DEFERRED SUBMITAL: CONTRACTOR TO | | FURNISH THE DE-WATERING PLAN AND BE REVIEWED BY THE | | DESIGN PROFESSIONAL OF RECORD AND THEIR SHOP DRAWING | | STAMP OF APPROVAL ON THE DOCUMENT BEFORE BEING | | FORWARDED TO THE BUILDING DEPARTMENT. THE DE-MUCKING | | AND DE-WATERING PLAN/ REPORT WILL NEED TO BE PROVIDING | | A METHOD OF DEWATERING & CALCULATIONS FOR THE | | APPROPRIATE SYSTEM AND ARE THE SOLE RESPONSIBILITY OF | | THE CONTRACTOR. DEPENDING ON THE TIME OF YEAR THE WATER | | TABLE WOULD BE 2 FT. TO 4 FT. BELOW GRADE AND ORGANIC | | MATERIALS WERE FOUND IN BORING # 3 TO A DEPTH OF 12 | | FEET BELOW GRADE. THE SUBMITTED SOILS REPORT REQUEST | | THAT THE GROUND WATER SHOULD BE CONTROLLED TO A DEPTH | | OF AT LEAST 2 FEET BELOW THE BOTTOM OF THE EXCAVATION | | DURING THE ENTIRE DEMUCKING OPERATION. 1803.5.4 | | GROUND-WATER TABLE. | | | | 3) BUILDING PROVISO DEFERED SUBMITTAL: THE CONTRACTOR | | MEP CONSTRUCTION GROUP HAS SUBMITTED A REQUEST FOR | | DEFERRED SUBMITTALS PER 2014 FLORIDA BUILDING CODE W | | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2 DEFERRED | | SUBMITTALS; | | 1) WOOD TRUSSES- SHOP DRAWINGS AND ENGINEERING SHEETS | | OF TRUSSES | | 2) ALUMINUM LOUVERS | | 3) EXTERIOR WINDOWS AND DOORS | | 4) ROOFING ASSEMBLIES | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL | | 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | JAMES A. WITMER BN, PX, CBO / SENIOR COMMERCIAL | | COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 / FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2017-06-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-06-07 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-07 |
Time |
09:01 |
Sent To |
|
|
Notes |
2017-06-07 12:31:14 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16120880 | | ADD: 3200 N. CONGRESS / TENNIS CENTER BUILDING | | CONT: HEDRICK BROTHERS | | TEL: 561-308-2954 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 3RD REVIEW | | DATE: WED. JUNE 07/ 2017 | | ACTION: DENIED | | | | 1) 3RD REQUEST. SEMI-COMPLIED. PLEASE NOTE THE PERMIT | | APPLICATION STILL INDICATES 3200 N. CONGRESS. IT IS THE | | CONTRACTORS RESPONSIBILITY TO UPDATE THE ADDRESS ON THE | | PERMIT APPLICATION. PLEASE ALSO NOTE THE PERMIT SET OF | | PLANS NOW INDICATE THE ADDRESS OF 1998 LACELEAF COURT. | | THIS APPEARS TO BE A TYPO, IN CONTACTING MR. ORIO, HE | | CONFIRMED THE ADDRESS SHOULD READ 1989 LACELEAF COURT. | | CITY MUNI CODE SEC.78-6 (1-7). THE SUBMITTED ADDRESS | | WILL BE REASSIGNED BY CONTACT: | | MICHAEL ORIO GIS SUPPORT SPECIALIST/ INFORMATION | | TECHNOLOGY | | TEL: 561-494-1040 | | E-MAIL: [email protected] | | | | 2) BUILDING PROVISO: THIS PROJECT QUALIFIES FOR ART IN | | PUBLIC PLACES. | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | PROJECT CONSTRUCTION COST. | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | PROJECTS. | | FOR CONTACT INFORMATION PLEASE CONTACT: | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | 822-1515 E-MAIL: [email protected] | | | | 3) 3RD REQUEST. THIS IS A CONTRACTOR ISSUE TO RIGHT | | BACK A WRITTEN RESPONSE!!!! THE RESPONSE LETTER WILL | | STAND IF NO WRITTEN RESPONSE FROM HEDRICK BROTHERS IN | | THE NEXT SET OF COMMENTS. | | | | THIS PROJECT THE TENNIS CENTER BUILDING IS EVALUATED AT | | $783420.00 DOLLARS. UNDER THE MAIN BUILDING PERMIT THE | | VALUES FOR THE, GROUNDWATER-DEWATERING, EXCAVATING, | | DE-MUCKING AND BACKFILL FOR THE BUILDING, MECHANICAL, | | ELECTRICAL, PLUMBING & ROOFING SUB-PERMITS ARE | | INCLUDED. PLEASE NOTE THIS REVIEW IS FOR THE BUILDING | | ONLY, NOT FOR ANY SITE AMENITIES OR PARKING LOTS. | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, EXHAUST | | HOODS, ANSUL SYSTEMS OR ALTERNATIVE AUTOMATIC | | FIRE-EXTINGUISHING SYSTEMS , WALK IN COOLERS & | | FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL | | TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED | | SUB-PERMITS, AWNING, CANOPY, FENCE, LANDSCAPE , | | IRRIGATION, AUGER CAST PILE AND OR FOUNDATION OR | | STRUCTURE ONLY PERMIT WILL BE SEPARATE REVIEWS AND | | ASSOCIATED FEES WITH EACH PERMIT. | | | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | PRIME OR MASTER PERMIT. | | | | | | | | | | 4) SEMI-COMPLIED. THIS REVIEW THE PLANS ARE SIGNED AND | | SEALED BUT IN THIS GENERATION OF PLANS THE PLANS DO NOT | | PROVIDE NAME OF THE LICENSE HOLDER. 61G1-16.004 TITLE | | BLOCK. ARCHITECT. (6) THE PRINTED NAME AND THE | | LICENSE/REGISTRATION NUMBER OF THE PERSON SEALING THE | | DOCUMENT. | | | | 5-7) COMPLIED. | | | | 8) 3RD REQUEST. RESPONSE INDICATES THE SURVEY IS TO BE | | SUBMITTED UNDER SEPARATE COVER. PLEASE REFER TO; | | 4X FEE NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) WITH | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | 1ST ROUND OF COMMENTS. IN THE ARCHITECTURAL SET OF | | PLANS THERE IS AN OVERALL MASTER SITE PLAN FOR THE | | DEVELOPMENT AND A SITE PLAN. THE CIVIL PLANS SHEET 4 OF | | 9 SHOWS THE LOCATION OF THE PROPOSED TENNIS PAVILION, | | BUT THERE IS NO SURVEY IN THIS REVIEW CYCLE GIVING THE | | LOCATION OF PROPERTY LINES AND THE DISTANCE FROM THE | | BUILDING TO SUCH PROPERTY LINES. | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS: | | . 107.3.5.1.1 COMMERCIAL BUILDINGS: BUILDINGS-SURVEY. | | CANNOT VERIFY: | | 2014 FBC-B TABLE 602 FIRE-RESISTANCE RATING | | REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE | | SEPARATION DISTANCE | | 2014 FBC-B TABLE 705.8. MAXIMUM AREA OF EXTERIOR WALL | | OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE | | OF OPENING PROTECTION | | | | 9) SHEET S-0.00 FOUNDATION NOTES 310000: | | | | 9A) 3RD REQUEST. THIS COMMENT IS A CONTRACTOR | | RESPONSIBILITY!!!RESPONSE INDICATES THAT THE REVISED | | GEOTECHNICAL REPORT THAT ADDRESSES THE EXTENT OF THE | | ONSITE SOILS ENGINEER TO BE SUBMITTED UNDER SEPARATE | | COVER IN RESPONSE TO THIS COMMENT. | | 4X FEE NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) WITH | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | 1ST ROUND OF COMMENTS. NOTES INDICATE THAT ALL SOILS | | BEARING ARE TO BE INSPECTED & APPROVED BY A | | GEOTECHNICAL ENGINEER. IN UNIVERSAL ENGINEERING | | GEOTECHNICAL ENGINEERING REPORT SUBMITTED THE SOILS | | ENGINEER FOUND IN (3) SOILS SAMPLES ORGANIC SOILS | | CONTENTS RANGING FROM 10.6 TO 67.6 PERCENT AND FROM A | | DEPTH OF 6 FEET TO 12 FEET BELOW GRADE. WE HAVE NO | | DOCUMENTATION FROM THE CONTRACTOR OR SOILS ENGINEER | | THERE WILL BE AN ONSITE SOILS ENGINEER DURING THE | | REMOVAL OF THE ORGANIC SOILS, AND REPLACED WITH A GOOD | | QUALITY FILL ACCORDING TO THE SPECIFICATIONS AND | | PROCEDURES OUTLINED IN THE SITE PREPARATION SECTION OF | | THE SUBMITTED SOILS REPORT. | | BASED ON THE SOILS ENGINEERS RECOMMENDATION FOR | | DEWATERING OF THE BUILDING SITE , OVER EXCAVATION, | | PLACEMENT OF FILL THERE SHALL BE QUALIFIED PERSONNEL | | AND EQUIPMENT TO MONITOR THE DEVELOPMENT OF THE SITE | | BUILDING PAD AS DESCRIBED IN SECTION 4.5 OF THIS | | REPORT. FBC-B 1803.4 QUALIFIED REPRESENTATIVE & | | 1803.5.8 COMPACTED FILL MATERIALS. | | | | 9B) BUILDING PROVISO, DEFERRED SUBMITAL: CONTRACTOR TO | | FURNISH THE DE-WATERING PLAN AND BE REVIEWED BY THE | | DESIGN PROFESSIONAL OF RECORD AND THEIR SHOP DRAWING | | STAMP OF APPROVAL ON THE DOCUMENT BEFORE BEING | | FORWARDED TO THE BUILDING DEPARTMENT. | | THE SECOND ISSUE WITH THE PREPARING FOR DE-MUCKING IS A | | DE-WATERING PLAN. TO DATE NO PLAN/ REPORT HAS BEEN | | SUBMITTED PROVIDING A METHOD OF DEWATERING & | | CALCULATIONS FOR THE APPROPRIATE SYSTEM AND ARE THE | | SOLE RESPONSIBILITY OF THE CONTRACTOR. DEPENDING ON THE | | TIME OF YEAR THE WATER TABLE WOULD BE 2 FT. TO 4 FT. | | BELOW GRADE AND ORGANIC MATERIALS WERE FOUND IN BORING | | # 3 TO A DEPTH OF 12 FEET BELOW GRADE. THE SUBMITTED | | SOILS REPORT REQUEST THAT THE GROUND WATER SHOULD BE | | CONTROLLED TO A DEPTH OF AT LEAST 2 FEET BELOW THE | | BOTTOM OF THE EXCAVATION DURING THE ENTIRE DEMUCKING | | OPERATION. 1803.5.4 GROUND-WATER TABLE. | | | | 10) COMPLIED. | | | | 11) BUILDING PROVISO DEFERED SUBMITTAL: THE CONTRACTOR | | HEDRICK BROTHER HAS SUBMITTED A REQUEST FOR DEFERRED | | SUBMITTALS PER 2014 FLORIDA BUILDING CODE W 2014 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, ADMINISTRATION 107.3.4.2 DEFERRED | | SUBMITTALS; | | 1) WOOD TRUSSES- SHOP DRAWINGS AND ENGINEERING SHEETS | | OF TRUSSES | | 2) ALUMINUM LOUVERS | | 3) EXTERIOR WINDOWS AND DOORS | | 4) ROOFING ASSEMBLIES | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL | | 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 12)COMPLIED. SHEET A-3. 2014 FBC-ACCESSIBILITY CODE | | 404.2.6. | | | | 13)COMPLIED. 2014 FBC-ENERGY CODE COMMERCIAL BUILDINGS | | | | 14) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-04-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-04-11 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-04-10 |
Time |
15:39 |
Sent To |
|
|
Notes |
2017-04-11 11:28:28 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16120880 | | ADD: 3200 N. CONGRESS / TENNIS CENTER BUILDING | | CONT: HEDRICK BROTHERS | | TEL: 561-308-2954 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2ND REVIEW | | DATE: TUES. APRIL 11/ 2017 | | ACTION: DENIED | | | | 1) 2ND REQUEST. A TRUE SITE ADDRESS WILL BE REQUIRED | | BEFORE THE PERMIT CAN BE ISSUED. THIS SITE HAS BEEN OR | | IS THE PROCESS OF BEING REPLATED WITH NEW STREET NAMES; | | THE PERMIT APPLICATION USED THE STREET NAME OF N. | | CONGRESS WHEREAS SHEET A-1.101 SHOWS THE STREET | | DIRECTLY IN FRONT OF THE BUILDING NAMED RESORT COURT. . | | CITY MUNI CODE SEC.78-6 (1-7). THE SUBMITTED ADDRESS | | WILL BE REASSIGNED BY CONTACT: | | MICHAEL ORIO GIS SUPPORT SPECIALIST/ INFORMATION | | TECHNOLOGY | | TEL: 561-494-1040 | | E-MAIL: [email protected] | | | | 2) BUILDING PROVISO: THIS PROJECT QUALIFIES FOR ART IN | | PUBLIC PLACES. THE CITY OF WEST PALM BEACH ART IN | | PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES TO ANY | | REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH THE | | PERMIT APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE | | TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | GREATER THAN $750,000 WILL NEED TO COMPLY WITH THIS | | ORDINANCE. | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | PROJECT CONSTRUCTION COST. | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | PROJECTS. | | FOR CONTACT INFORMATION PLEASE CONTACT: | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | 822-1515 E-MAIL: [email protected] | | | | 3) 2ND REQUEST. THIS PROJECT THE TENNIS CENTER BUILDING | | IS EVALUATED AT $783420.00 DOLLARS. UNDER THE MAIN | | BUILDING PERMIT THE VALUES FOR THE, | | GROUNDWATER-DEWATERING, EXCAVATING, DE-MUCKING AND | | BACKFILL FOR THE BUILDING, MECHANICAL, ELECTRICAL, | | PLUMBING & ROOFING SUB-PERMITS ARE INCLUDED. PLEASE | | NOTE THIS REVIEW IS FOR THE BUILDING ONLY, NOT FOR ANY | | SITE AMENITIES OR PARKING LOTS. | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, EXHAUST | | HOODS, ANSUL SYSTEMS OR ALTERNATIVE AUTOMATIC | | FIRE-EXTINGUISHING SYSTEMS , WALK IN COOLERS & | | FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL | | TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED | | SUB-PERMITS, AWNING, CANOPY, FENCE, LANDSCAPE , | | IRRIGATION, AUGER CAST PILE AND OR FOUNDATION OR | | STRUCTURE ONLY PERMIT WILL BE SEPARATE REVIEWS AND | | ASSOCIATED FEES WITH EACH PERMIT. | | | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | PRIME OR MASTER PERMIT. | | | | | | | | | | 4) SEMI-COMPLIED. ONE SET OF PLANS IS SIGNED AND | | SEALED. THE 2ND SET OF PLANS ARE SIGNED BUT THE SEAL ON | | THE PLANS IS NOT EMBOSSED ENOUGH TO BE LEGIBLE. THE | | SEAL IS NOT A COLORED SEAL. | | 1ST ROUND OF COMMENTS. ALL SHEETS SIGNED BY THE | | ARCHITECT DANIELE E. ADACHE THE DESIGNER HAS USED AN | | INK STAMP FOR THE REQUIRED WRITTEN SIGNATURE. FL ADMIN | | CODE 61G16.003 ARCHITECTS. PLANS ARE TO BE SIGNED WITH | | A FULL SIGNATURE FROM THE ARCHITECT OF RECORD PER | | 481.221 WITH A MINIMUM OF FIRST AND LAST NAME AS SHOWN | | ON THE ARCHITECTS' LICENSE, FAC 61G1-16.003 | | | | 5) 2ND REQUEST. PLANS THAT STILL SHOW THE FINISH FLOOR | | IN NAVD: | | A-0.0.02 UNDER THE HEADING PROJECT COMPONENTS/ BUILD. | | HEIGHT, | | A-1.3.01 IS GIVEN BOTH NGVD AND NAVD. THE FLOOR PLAN IS | | NGVD, THE HEADING BUILDING HEIGHT IN NAVD | | 1ST ROUND OF COMMENTS. DISCREPANCY IN PLANS. SHEET | | 1-1.1.02 VERSES A-1.3.0.1. SHEET A-1.1.02 INDICATES THE | | FINISH FLOOR ELEVATION AS 18.00 FT. NGVD WHEREAS SHEET | | A-1.3.0.1 THE FINISH FLOOR HEIGHT IS EXPRESSED AS 22.00 | | FT. NAVD88. THE CITY OF WEST PALM BEACH IS STILL | | WORKING OFF OF THE FIRM MAPS DATED MARCH 1/ 1979. | | PLEASE UPDATE PLANS TO NGVD. 107.2.1.3 ADDITIONAL | | INFORMATION IS REQUIRED. DISCREPANCY IN PLANS. | | | | 6-7) COMPLIED. | | | | 8) 2ND REQUEST. RESPONSE INDICATES THE SURVEY IS TO BE | | SUBMITTED UNDER SEPARATE COVER. PLEASE REFER TO; | | 4X FEE NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) WITH | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | 1ST ROUND OF COMMENTS. IN THE ARCHITECTURAL SET OF | | PLANS THERE IS AN OVERALL MASTER SITE PLAN FOR THE | | DEVELOPMENT AND A SITE PLAN. THE CIVIL PLANS SHEET 4 OF | | 9 SHOWS THE LOCATION OF THE PROPOSED TENNIS PAVILION, | | BUT THERE IS NO SURVEY IN THIS REVIEW CYCLE GIVING THE | | LOCATION OF PROPERTY LINES AND THE DISTANCE FROM THE | | BUILDING TO SUCH PROPERTY LINES. | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS: | | . 107.3.5.1.1 COMMERCIAL BUILDINGS: BUILDINGS-SURVEY. | | CANNOT VERIFY: | | 2014 FBC-B TABLE 602 FIRE-RESISTANCE RATING | | REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE | | SEPARATION DISTANCE | | 2014 FBC-B TABLE 705.8. MAXIMUM AREA OF EXTERIOR WALL | | OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE | | OF OPENING PROTECTION | | | | 9) SHEET S-0.00 FOUNDATION NOTES 310000: | | | | 9A) 2ND REQUEST. RESPONSE INDICATES THAT THE REVISED | | GEOTECHNICAL REPORT THAT ADDRESSES THE EXTENT OF THE | | ONSITE SOILS ENGINEER TO BE SUBMITTED UNDER SEPARATE | | COVER IN RESPONSE TO THIS COMMENT. | | 4X FEE NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) WITH | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | 1ST ROUND OF COMMENTS. NOTES INDICATE THAT ALL SOILS | | BEARING ARE TO BE INSPECTED & APPROVED BY A | | GEOTECHNICAL ENGINEER. IN UNIVERSAL ENGINEERING | | GEOTECHNICAL ENGINEERING REPORT SUBMITTED THE SOILS | | ENGINEER FOUND IN (3) SOILS SAMPLES ORGANIC SOILS | | CONTENTS RANGING FROM 10.6 TO 67.6 PERCENT AND FROM A | | DEPTH OF 6 FEET TO 12 FEET BELOW GRADE. WE HAVE NO | | DOCUMENTATION FROM THE CONTRACTOR OR SOILS ENGINEER | | THERE WILL BE A ONSITE | | SOILS ENGINEER DURING THE REMOVAL OF THE ORGANIC SOILS, | | AND REPLACED WITH A GOOD QUALITY FILL ACCORDING TO THE | | SPECIFICATIONS AND PROCEDURES OUTLINED IN THE SITE | | PREPARATION SECTION OF THE SUBMITTED SOILS REPORT. | | BASED ON THE SOILS ENGINEERS RECOMMENDATION FOR | | DEWATERING OF THE BUILDING SITE , OVER EXCAVATION, | | PLACEMENT OF FILL THERE SHALL BE QUALIFIED PERSONNEL | | AND EQUIPMENT TO MONITOR THE DEVELOPMENT OF THE SITE | | BUILDING PAD AS DESCRIBED IN SECTION 4.5 OF THIS | | REPORT. FBC-B 1803.4 QUALIFIED REPRESENTATIVE & | | 1803.5.8 COMPACTED FILL MATERIALS. | | | | 9B) BUILDING PROVISO, DEFERRED SUBMITAL: CONTRACTOR TO | | FURNISH THE DE-WATERING PLAN AND BE REVIEWED BY THE | | DESIGN PROFESSIONAL OF RECORD AND THEIR SHOP DRAWING | | STAMP OF APPROVAL ON THE DOCUMENT BEFORE BEING | | FORWARDED TO THE BUILDING DEPARTMENT. | | THE SECOND ISSUE WITH THE PREPARING FOR DE-MUCKING IS A | | DE-WATERING PLAN. TO DATE NO PLAN/ REPORT HAS BEEN | | SUBMITTED PROVIDING A METHOD OF DEWATERING & | | CALCULATIONS FOR THE APPROPRIATE SYSTEM AND ARE THE | | SOLE RESPONSIBILITY OF THE CONTRACTOR. DEPENDING ON THE | | TIME OF YEAR THE WATER TABLE WOULD BE 2 FT. TO 4 FT. | | BELOW GRADE AND ORGANIC MATERIALS WERE FOUND IN BORING | | # 3 TO A DEPTH OF 12 FEET BELOW GRADE. THE SUBMITTED | | SOILS REPORT REQUEST THAT THE GROUND WATER SHOULD BE | | CONTROLLED TO A DEPTH OF AT LEAST 2 FEET BELOW THE | | BOTTOM OF THE EXCAVATION DURING THE ENTIRE DEMUCKING | | OPERATION. 1803.5.4 GROUND-WATER TABLE. | | | | 10A) SEMI-COMPLIED. 2ND REQUEST. SHEETS A-1.2.01 VERSES | | SHEET S-2.01. THE RESPONSE INDICATES THE INTENT OF THE | | PLANS BUT THE RESPONSE DOES NOT GO OUT TO BE PART OF | | THE PERMITTED SET OF DOCUMENTS. PLEASE SHOW THE FINISH | | GRADE AND ROUGH GRADE AT ALL OF THE EGRESS DOORS. THE | | RESPONSE INDICATES THERE IS TO BE SAND SET PAVER AT | | DOOR EXITS 1 & 2 WITH THE DECK TERMINATING ? INCH BELOW | | FINISH FLOOR. THIS IS NEW WORK AND MUST MEET THE | | REQUIREMENTS OF 303.2 AND 303.3 OF THE 2014 FBC-ACCESS. | | CODE. SHEET A-6.2.01 THE DOOR SCHEDULE FOR THE 3 EGRESS | | DOORS ( 100, 102 & 105) ALL HAVE HARDWARE TYPE # 1. NO | | DOOR THRESHOLD IS SPECIFIED, PLANS INDICATE THE BALANCE | | OF HARDWARE BY DOOR MANUFACTURER, THE DOOR HARDWARE | | WOULD NOT BE IDENTIFIED UNTIL THE DOOR PRODUCT APPROVAL | | WAS SUBMITTED AND THE CONTRACTOR WILL NEED TO IDENTIFY | | THE THRESHOLD FOR ACCESSIBILITY REQUIREMENT 404.2.5 | | 2014 FBC-ACCESSIBILITY CODE. | | 1ST ROUND OF COMMENTS. PLEASE REVIEW SHEETS A-1.2.01 | | VERSES SHEET S-2.01 FOR ACCESSIBLE EXITS. SHEET S-2.01 | | SHOWS: | | EXIT # 1 TO BE -0FT. 4 INCHES BELOW FINISH FLOOR | | SIGNAGE REQUIRED, WHERE THE ACCESSIBLE EGRESS IS | | LOCATED. | | 2014 FBC-ACCESSIBILITY CODE 216.3 DIRECTIONAL AND | | INFORMATION SIGNS AND 216.4 MEANS OF EGRESS. | | EXIT # 2 TO BE -0 FT. 03/4 INCH BELOW FINISH FLOOR | | COMPLY WITH ACCESS. CODE 303.2. | | EXIT # 3 TO BE HEIGHT UNKNOWN, NOT SHOWN ON PLANS. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | 10B) SEE COMMENT ABOVE. THE CARD ROOM # 103 HAS AN | | OCCUPANT LOAD > THAN 50 REQUIRING (2) EXITS. PLEASE | | SHOW COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE 207.1 | | ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THE 2003 | | IBC SECTION 1007. 2003 IBC-B 1007.1. WHERE 2 OR MORE | | MEANS OF EGRESS IS REQUIRED BY SECTION 1014.1 OR 1018.1 | | FROM ANY ACCESSIBLE PORTION OF THE SPACE SHALL BE | | SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS. | | | | 11) BUILDING PROVISO DEFERED SUBMITTAL: THE CONTRACTOR | | HEDRICK BROTHER HAS SUBMITTED A REQUEST FOR DEFERRED | | SUBMITTALS PER 2014 FLORIDA BUILDING CODE W 2014 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, ADMINISTRATION 107.3.4.2 DEFERRED | | SUBMITTALS; | | 1) WOOD TRUSSES- SHOP DRAWINGS AND ENGINEERING SHEETS | | OF TRUSSES | | 2) ALUMINUM LOUVERS | | 3) EXTERIOR WINDOWS AND DOORS | | 4) ROOFING ASSEMBLIES | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL | | 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 12)COMPLIED. SHEET A-3. 2014 FBC-ACCESSIBILITY CODE | | 404.2.6. | | | | 13) 2014 FBC-ENERGY CODE COMMERCIAL BUILDINGS C401.2 | | BUILDINGS CAN COMPLY WITH ASHRAE 90.1-2010(2014) ENERGY | | CONSERVATION, ENERGY GAUGE SUMMIT V5.20 INPUT DATA | | REPORT, MATERIALS USED: | | | | 13A) 2ND REQUEST. WALLS EXTERIOR, THE INPUT REPORT | | INDICATES ON EXTERIOR WALLS, 8 INCH CMU WITH 3/4 INCH | | ISO (ISO, (POLYISOCYANURATE INSULATION) BETWEEN @24 | | INCHES O.C. AND 1/2 INCH GYPSUM. THE PLANS SHEETS | | A-3.1.01 & A-3.1.02. NOW SHOW 1.5 INCH R-6.5 BATT | | INSULATION AS MANUFACTURED BY OWENS CORNING OR APPROVED | | EQUAL. THIS IS A DISCREPANCY IN PLANS 107.2.1.3. 2014 | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1.3: W.P.B. | | ADMINISTRATIVE CODE/2014 DRAWINGS & SPECIFICATIONS | | SHALL CONTAIN INFORMATION, SUCH INFORMATION SHALL BE | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". | | | | 13B) COMPLIED. ROOFING INSULATION. | | | | 13C)2ND REQUEST. IN THE INPUT DATA REPORT FOR EACH | | ELEVATION THERE ARE DISCREPANCIES IN THE AMOUNT OF | | WINDOWS, THE SIZE OF THE OPENINGS FOR EACH ELEVATION. | | ONE SET OF PLANS MARKED UP. | | 1ST RESPONSE. THE INPUT REPORT INDICATES A TOTAL OF | | 772.4 SQUARE FEET WHEN THE GLAZED AREAS ARE TOTALED. | | FROM THE ELEVATIONS THE TOTAL GLAZED OPENINGS | | (INCLUDING DOORS) IS 1141 (APPROXIMATELY) SQUARE FEET? | | WHY SUCH A DISCREPANCY? 107.2.1.3 ADDITIONAL | | INFORMATION IS REQUIRED. | | | | 14) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-01-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-20 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-18 |
Time |
13:58 |
Sent To |
|
|
Notes |
2017-01-20 15:40:59 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16120880 | | ADD: 3200 N. CONGRESS / TENNIS CENTER BUILDING | | CONT: HEDRICK BROTHERS | | TEL: 561-308-2954 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 1ST REVIEW | | DATE: FRI. JAN. 20/ 2017 | | ACTION: DENIED | | | | 1) THIS SITE HAS BEEN OR IS THE PROCESS OF BEING | | REPLATED WITH NEW STREET NAMES; THE PERMIT APPLICATION | | USED THE STREET NAME OF N. CONGRESS WHEREAS SHEET | | A-1.101 SHOWS THE STREET DIRECTLY IN FRONT OF THE | | BUILDING NAMED RESORT COURT. . CITY MUNI CODE SEC.78-6 | | (1-7). THE SUBMITTED ADDRESS WILL BE REASSIGNED BY | | CONTACT: | | MICHAEL ORIO GIS SUPPORT SPECIALIST/ INFORMATION | | TECHNOLOGY | | TEL: 561-494-1040 | | E-MAIL: [email protected] | | | | 2) THIS PROJECT QUALIFIES FOR ART IN PUBLIC PLACES. THE | | CITY OF WEST PALM BEACH ART IN PUBLIC PLACES ORDINANCE | | REQUIREMENT THAT APPLIES TO ANY REMODEL OR NEW | | CONSTRUCTION PROJECT FOR WHICH THE PERMIT APPLICATION | | WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL PROJECT | | CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | PROJECT CONSTRUCTION COST. | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | PROJECTS. | | FOR CONTACT INFORMATION PLEASE CONTACT: | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | 822-1515 E-MAIL: [email protected] | | | | 3) THIS PROJECT THE TENNIS CENTER BUILDING IS EVALUATED | | AT $783420.00 DOLLARS. UNDER THE MAIN BUILDING PERMIT | | THE VALUES FOR THE, GROUNDWATER-DEWATERING, EXCAVATING, | | DE-MUCKING AND BACKFILL FOR THE BUILDING, MECHANICAL, | | ELECTRICAL, PLUMBING & ROOFING SUB-PERMITS ARE | | INCLUDED. PLEASE NOTE THIS REVIEW IS FOR THE BUILDING | | ONLY, NOT FOR ANY SITE AMENITIES OR PARKING LOTS. | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, EXHAUST | | HOODS, ANSUL SYSTEMS OR ALTERNATIVE AUTOMATIC | | FIRE-EXTINGUISHING SYSTEMS , WALK IN COOLERS & | | FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL | | TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED | | SUB-PERMITS, AWNING, CANOPY, FENCE, LANDSCAPE , | | IRRIGATION, AUGER CAST PILE AND OR FOUNDATION OR | | STRUCTURE ONLY PERMIT WILL BE SEPARATE REVIEWS AND | | ASSOCIATED FEES WITH EACH PERMIT. | | | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | PRIME OR MASTER PERMIT. | | | | | | | | | | 4) ALL SHEETS SIGNED BY THE ARCHITECT DANIELE E. ADACHE | | THE DESIGNER HAS USED AN INK STAMP FOR THE REQUIRED | | WRITTEN SIGNATURE. FL ADMIN CODE 61G16.003 ARCHITECTS. | | PLANS ARE TO BE SIGNED WITH A FULL SIGNATURE FROM THE | | ARCHITECT OF RECORD PER 481.221 WITH A MINIMUM OF FIRST | | AND LAST NAME AS SHOWN ON THE ARCHITECTS' LICENSE, FAC | | 61G1-16.003 | | | | 5) DISCREPANCY IN PLANS. SHEET 1-1.1.02 VERSES | | A-1.3.0.1. SHEET A-1.1.02 INDICATES THE FINISH FLOOR | | ELEVATION AS 18.00 FT. NGVD WHEREAS SHEET A-1.3.0.1 THE | | FINISH FLOOR HEIGHT IS EXPRESSED AS 22.00 FT. NAVD88. | | THE CITY OF WEST PALM BEACH IS STILL WORKING OFF OF THE | | FIRM MAPS DATED MARCH 1/ 1979. PLEASE UPDATE PLANS TO | | NGVD. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | DISCREPANCY IN PLANS. | | | | 6) SHEET A-0.0.02 UNDER THE HEADING PROJECT COMPONENTS, | | THE REQUIRED PLUMBING FIXTURE COUNT THE OCCUPANCY TYPE | | IS LISTED AS AN A2 WHEREAS UNDER THE HEADING BUILDING | | CODE DATA THE OCCUPANCY TYPE IS LISTED AS AN A3 | | EXERCISE ROOM. PLEASE REVISE THE DISCREPANCY IN THE | | PLANS. 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | | | 7) SHEET A-1.2.01 THE CARD ROOM 103 HAS 2 DIFFERENT | | OCCUPANT LOADS LISTED ON THIS SHEET. IN THE DRAWING THE | | ROOM 103 THE CARD ROOM SHOWS AN OCCUPANT LOAD OF 71 | | WHEREAS THE OCCUPANT LOAD TABLE INDICATES THE OCCUPANT | | LOAD TAKEN AT 7 SQ. FT./ OCCUPANT WITH A LOAD OF 151. | | DISCREPANCY IN THE PLANS. . 107.2.1.3 ADDITIONAL | | INFORMATION REQUIRED. NOTE IF A ASSEMBLY OCCUPANCY IS | | TO BE USED FOR MANY VARIOUS ACTIVITIES THEN THE MOST | | RESTRICTIVE USE IS TO BE USED FOR THE EXITING | | REQUIREMENTS. | | | | 8) IN THE ARCHITECTURAL SET OF PLANS THERE IS AN | | OVERALL MASTER SITE PLAN FOR THE DEVELOPMENT AND A SITE | | PLAN. THE CIVIL PLANS SHEET 4 OF 9 SHOWS THE LOCATION | | OF THE PROPOSED TENNIS PAVILION, BUT THERE IS NO SURVEY | | IN THIS REVIEW CYCLE GIVING THE LOCATION OF PROPERTY | | LINES AND THE DISTANCE FROM THE BUILDING TO SUCH | | PROPERTY LINES. | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS: | | . 107.3.5.1.1 COMMERCIAL BUILDINGS: BUILDINGS-SURVEY. | | CANNOT VERIFY: | | 2014 FBC-B TABLE 602 FIRE-RESISTANCE RATING | | REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE | | SEPARATION DISTANCE | | 2014 FBC-B TABLE 705.8. MAXIMUM AREA OF EXTERIOR WALL | | OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE | | OF OPENING PROTECTION | | | | 9) SHEET S-0.00 FOUNDATION NOTES 310000: | | 9A) NOTES INDICATE THAT ALL SOILS BEARING ARE TO BE | | INSPECTED & APPROVED BY A GEOTECHNICAL ENGINEER. IN | | UNIVERSAL ENGINEERING GEOTECHNICAL ENGINEERING REPORT | | SUBMITTED THE SOILS ENGINEER FOUND IN (3) SOILS SAMPLES | | ORGANIC SOILS CONTENTS RANGING FROM 10.6 TO 67.6 | | PERCENT AND FROM A DEPTH OF 6 FEET TO 12 FEET BELOW | | GRADE. WE HAVE NO DOCUMENTATION FROM THE CONTRACTOR OR | | SOILS ENGINEER THERE WILL BE A ONSITE | | SOILS ENGINEER DURING THE REMOVAL OF THE ORGANIC SOILS, | | AND REPLACED WITH A GOOD QUALITY FILL ACCORDING TO THE | | SPECIFICATIONS AND PROCEDURES OUTLINED IN THE SITE | | PREPARATION SECTION OF THE SUBMITTED SOILS REPORT. | | BASED ON THE SOILS ENGINEERS RECOMMENDATION FOR | | DEWATERING OF THE BUILDING SITE , OVER EXCAVATION, | | PLACEMENT OF FILL THERE SHALL BE QUALIFIED PERSONNEL | | AND EQUIPMENT TO MONITOR THE DEVELOPMENT OF THE SITE | | BUILDING PAD AS DESCRIBED IN SECTION 4.5 OF THIS | | REPORT. FBC-B 1803.4 QUALIFIED REPRESENTATIVE & | | 1803.5.8 COMPACTED FILL MATERIALS. | | | | 9B) THE SECOND ISSUE WITH THE PREPARING FOR DE-MUCKING | | IS A DE-WATERING PLAN. TO DATE NO PLAN/ REPORT HAS BEEN | | SUBMITTED PROVIDING A METHOD OF DEWATERING & | | CALCULATIONS FOR THE APPROPRIATE SYSTEM AND ARE THE | | SOLE RESPONSIBILITY OF THE CONTRACTOR. DEPENDING ON THE | | TIME OF YEAR THE WATER TABLE WOULD BE 2 FT. TO 4 FT. | | BELOW GRADE AND ORGANIC MATERIALS WERE FOUND IN BORING | | # 3 TO A DEPTH OF 12 FEET BELOW GRADE. THE SUBMITTED | | SOILS REPORT REQUEST THAT THE GROUND WATER SHOULD BE | | CONTROLLED TO A DEPTH OF AT LEAST 2 FEET BELOW THE | | BOTTOM OF THE EXCAVATION DURING THE ENTIRE DEMUCKING | | OPERATION. 1803.5.4 GROUND-WATER TABLE. | | | | 10A) PLEASE REVIEW SHEETS A-1.2.01 VERSES SHEET S-2.01 | | FOR ACCESSIBLE EXITS. SHEET S-2.01 SHOWS: | | EXIT # 1 TO BE -0FT. 4 INCHES BELOW FINISH FLOOR | | SIGNAGE REQUIRED, WHERE THE ACCESSIBLE EGRESS IS | | LOCATED. | | 2014 FBC-ACCESSIBILITY CODE 216.3 DIRECTIONAL AND | | INFORMATION SIGNS AND 216.4 MEANS OF EGRESS. | | EXIT # 2 TO BE -0 FT. 03/4 INCH BELOW FINISH FLOOR | | COMPLY WITH ACCESS. CODE 303.2. | | EXIT # 3 TO BE HEIGHT UNKNOWN, NOT SHOWN ON PLANS. | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | 10B) THE CARD ROOM # 103 HAS AN OCCUPANT LOAD > THAN 50 | | REQUIRING (2) EXITS. PLEASE SHOW COMPLIANCE WITH 2014 | | FBC-ACCESSIBILITY CODE 207.1 ACCESSIBLE MEANS OF EGRESS | | SHALL COMPLY WITH THE 2003 IBC SECTION 1007. 2003 IBC-B | | 1007.1. WHERE 2 OR MORE MEANS OF EGRESS IS REQUIRED BY | | SECTION 1014.1 OR 1018.1 FROM ANY ACCESSIBLE PORTION OF | | THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO | | ACCESSIBLE MEANS OF EGRESS. | | 11A) BUILDING PROVISO: THE CONTRACTOR HEDRICK BROTHER | | HAS SUBMITTED A REQUEST FOR DEFERRED SUBMITTALS PER | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.3.4.2 DEFERRED SUBMITTALS; | | 1) WOOD TRUSSES- SHOP DRAWINGS AND ENGINEERING SHEETS | | OF TRUSSES | | 2) ALUMINUM LOUVERS | | 3) EXTERIOR WINDOWS AND DOORS | | 4) ROOFING ASSEMBLIES | | | | 11B) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 12) SHEET A-3.01 IN BOTH THE MENS AND LADIES RESTROOMS | | IT APPEARS THERE IS LESS THAN 4 FOOT BETWEEN DOORS IN | | SERIES 2014 FBC-ACCESSIBILITY CODE 404.2.6. | | | | 13) 2014 FBC-ENERGY CODE COMMERCIAL BUILDINGS C401.2 | | BUILDINGS CAN COMPLY WITH ASHRAE 90.1-2010(2014) ENERGY | | CONSERVATION, ENERGY GAUGE SUMMIT V5.20 INPUT DATA | | REPORT, MATERIALS USED: | | | | 13A) WALLS EXTERIOR, THE INPUT REPORT INDICATES ON | | EXTERIOR WALLS, 8 INCH CMU WITH ? INCH ISO BETWEEN @24 | | INCHES O.C. AND ? INCH GYPSUM. THE PLANS DO NOT SHOW | | THE USE OF ? INCH ISO, (POLYISOCYANURATE INSULATION). . | | SEE SHEETS A-3.1.01 NOR A-3.1.02. | | | | 13B) ROOFING INSULATION, THE INPUT REPORT INDICATES THE | | USE OF R-19 INSULATION IN THE ATTIC, NONE OF THE CUT | | SECTIONS OF THE PLANS SHOW COMPLIANCE. SEE SHEETS | | A-3.1.01 NOR A-3.1.02. | | | | 13C) THE INPUT REPORT INDICATES A TOTAL OF 772.4 SQUARE | | FEET WHEN THE GLAZED AREAS ARE TOTALED. FROM THE | | ELEVATIONS THE TOTAL GLAZED OPENINGS (INCLUDING DOORS) | | IS 1141 (APPROXIMATELY) SQUARE FEET? WHY SUCH A | | DISCREPANCY? 107.2.1.3 ADDITIONAL INFORMATION IS | | REQUIRED. | | | | 14) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2018-02-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-02-16 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-02-16 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-06-09 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-06-09 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-03-27 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-03-27 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-03-27 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-01-12 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-01-12 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-01-12 |
Time |
08:46 |
Sent To |
|
|
Notes |
2017-01-12 09:03:11 | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 | | COMMENTS: | | | | 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE | | PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE | | PERMITS AND DATA CUT SHEET SUBMITTALS FOR ALL SITE | | LIGHTING AND ASSOCIATED EQUIPMENT, ALL LOW VOLTAGE | | SYSTEMS TO INCLUDE BUT NOT LIMITED TO ACCESS CONTROLS, | | CCTV, PHONE AND DATA, WIRELESS SYSTEMS, ETC. A NOTE | | WILL SUFFICE. | | 2. SHEET E1.1.0.1- PLEASE ADD A GENERAL NOTE TO SHEET | | TO INDICATE THE REQUIREMENTS OF NEC 300.5D3 AND TABLE | | 300.5 FOR MINIMUM COVER REQUIREMENTS FOR CONDUITS AND | | THE PLACEMENT OF A WARNING RIBBON FOR THE SERVICE | | LATERAL CONDUCTORS SHOWN FOR THIS PROJECT. A NOTE WILL | | SUFFICE | | 3. SHEET E1.1.0.1- ADD A NOTE TO MAINTAIN ALL | | ELECTRICAL EQUIPMENT ABOVE THE BASELINE FLOOD ELEVATION | | PER STATE AND CITY REGULATORY AGENCIES. | | 4. ADDRESS FIRE COMMENTS RELATED TO ELECTRICAL. | | 5. PLEASE PROVIDE AVAILABLE FAULT CURRENT AVAILABLE AT | | THE FPL SERVICE. ATTACH TO DOCUMENTS LETTER FROM | | FLORIDA POWER & LIGHT INDICATING AIC. SHOW AIC | | CALCULATION BASED ON INFORMATION PROVIDED BY UTILITY | | FOR APPROVAL. NEC 110.24 FBC 107 | | 6. SHOW AT THE SERVICE GROUNDING ELECTRODE CONDUCTOR A | | INTERSYSTEM BONDING TERMINAL PER NEC 250.94 | | 7. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO | | INDICATE NEC 110.16. ARC FLASH WARNING SIGNS AND NEC | | 110.24- AVAILABLE FAULT CURRENT- FIELD MARKINGS; SEE | | VERBIAGE IN CODE. | | 8. PROVIDE A SHOW COMPLIANCE WITH FBC EC 405.7.3, | | 405.7.4 SEE VERBIAGE IN THE CODE REGARDING VOLTAGE DROP | | AND COMPLETIONS DOCUMENTS. | | 9. PLEASE SHOW TO COMPLY WITH THE FBC ENERGY | | CONSERVATION THE MEANS FOR AUTOMATIC LIGHTING CONTROLS | | AND LIGHTING DENSITIES ALLOWANCES PER SECTION C405, | | C405.2. | | 10. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL | | FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS | | REGARDING THIS PROJECT. | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2017-02-24 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-02-24 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-02-24 |
Time |
16:53 |
Sent To |
|
|
Notes |
2017-02-24 16:53:13 | PER MGONZALEZ EMAIL OF 2/24/17, ENGINEERING REVIEW WILL | | OCURR WITH THE FORMAL CIVIL SUBMITTAL ONLY. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2018-02-12 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-02-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-02-12 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-05-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-05-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-05-25 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-03-29 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-03-29 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-03-28 |
Time |
16:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-01-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-01-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-01-05 |
Time |
12:47 |
Sent To |
|
|
Notes |
2017-01-09 08:35:45 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 0.0.02 - THE IS AN INCORRECT REFERENCE TO | | THE FIRE CODE; THE BROWARD COUNT ADMENDMENTS IS NOT | | APPLICABLE WITHIN THEI JURISDICTION. | | | | PLEASE REMOVE THE REFERENCE AND ENSURE NO CONFLICTS. | | | | | | | | 2) SHEET A 1.2.01 - THE LIFE SAFETY NOTES INDICATE | | REFERENCES TOA FIRE SPRINKLER AND FIRE ALARM. THESE | | NOTES ARE CONFUSING AS TO THEM BEING INSTALLED OR NOT. | | | | PLEASE CLARIFY AND REMOVE ANY REFERENCES IF NOT | | PROPOSED. | | | | | | | | 3) SHEET 1.2.01 & 2.1.02 - THERE ARE INDICATIONS OF AN | | EXIT, # 2, LEADING TO THE TERRACE; HOWEVER, THE TERRACE | | INDICATES RALINGS WITH NO EXIT VOID OR GATE. | | | | NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | | 7.7 DISCHARGE FROM EXITS. | | 7.7.1* EXIT TERMINATION. EXITS SHALL TERMINATE | | DIRECTLY, AT A PUBLIC WAY OR AT AN EXTERIOR EXIT | | DISCHARGE, UNLESS OTHERWISE PROVIDED IN 7.7.1.2 THROUGH | | 7.7.1.4. | | | | PLEASE CLARIFY AND CORRECT. | | | | | | | | 4) SHEET 1.2.01 & 2.1.02 - THE ARE TWO EXITS INDICATED | | FROM THE ASSEMBLY ROOM WITH A SEPARATION OF 17.5 FT. | | THE EXITS ARE REQUIRED TO BE SEPARATED BY A MINIMUM OF | | HALF THE AREA DIMENSION. | | | | | | 7.5.1.3.1 WHERE MORE THAN ONE EXIT, EXIT ACCESS, OR | | EXIT DISCHARGE IS REQUIRED FROM A BUILDING OR PORTION | | THEREOF, SUCH EXITS, EXIT ACCESSES, OR EXIT DISCHARGES | | SHALL BE REMOTELY LOCATED FROM EACH OTHER AND BE | | ARRANGED TO MINIMIZE THE POSSIBILITY THAT MORE THAN ONE | | HAS THE POTENTIAL TO BE BLOCKED BY ANY ONE FIRE OR | | OTHER EMERGENCY CONDITION. | | | | 7.5.1.3.2* WHERE TWO EXITS, EXIT ACCESSES, OR EXIT | | DISCHARGES ARE REQUIRED, THEY SHALL BE LOCATED AT A | | DISTANCE FROM ONE ANOTHER NOT LESS THAN ONE-HALF THE | | LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE | | BUILDING OR AREA TO BE SERVED, MEASURED IN A STRAIGHT | | LINE BETWEEN THE NEAREST EDGE OF THE EXITS, EXIT | | ACCESSES, OR EXIT DISCHARGES, UNLESS OTHERWISE PROVIDED | | IN 7.5.1.3.3 THROUGH 7.5.1.3.5. | | | | | | PLEASE REVIEW, CLARIFY AND/OR CORRECT. | | | | | | | | 5) SHEET A 2.1.02 - THERE ARE INDICATIONS OF LIGHT | | WIEGHT TRUSS DESIGN. | | | | PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR | | STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES | | HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A | | MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND | | 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR. | | THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO | | THE LEFT OF THE MAIN ENTRY DOOR. | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | MARKED WITH THE LETTER "R". | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | SHALL BE MARKED WITH THE LETTER "F". | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | PLEASE PROVIDE A NOTE FOR THE APPLICABLE SIGNAGE AT THE | | FRONT ENTRANCE. | | | | | | | | 6) SHEET 6.2.01 - THERE IS A LABEL INDICATION WITHIN | | THE DOOR SCHEDULE OF A C45; HOWEVER, THERE IS NO | | CALL-OUT INDICATING/IDENTIFYING WHAT IT IS. | | | | PLEASE INDICATE WHAT C45 IS? | | | | | | | | 7) SHEET A 6.2.01 - IN THE DOOR SCHEDULE FOR DOOR 104, | | THAT SERVES ROOM 151, THERE IS NO EXIT DEVICE IN THE | | COMMENT SECTION. | | | | PLEASE CORRECT. | | | | | | | | 8) SHEET A 6.2.01 - THE IS A NOTE ON ALL THE EXIT DOORS | | OF A "CYLINDER KEY SYSTEM". PER NFPA 101, CHAPTER 7, | | MEANS OF EGRESS | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | OPERATION FROM THE EGRESS SIDE. INDICATE IF THE DOORS | | WILL BE EQUIPPED WITH ANY LOCK/LATCH. IF THE DOORS WILL | | BE EQUIPPED WITH A LOCK/LATCH, INDICATE HOW THE | | LOCK/LATCH WILL BE RELEASED FROM THE EGRESS SIDE OF THE | | DOOR. | | | | 7.2.1.5.10* A LATCH OR OTHER FASTENING DEVICE ON A DOOR | | LEAF SHALL BE PROVIDED WITH A RELEASING DEVICE THAT HAS | | AN OBVIOUS METHOD OF OPERATION AND THAT IS READILY | | OPERATED UNDER ALL LIGHTING CONDITIONS. | | 7.2.1.5.10.1 THE RELEASING MECHANISM FOR ANY LATCH | | SHALL BE LOCATED AS FOLLOWS: | | (1) NOT LESS THAN 34 IN. (865 MM) ABOVE THE FINISHED | | FLOOR FOR OTHER THAN EXISTING INSTALLATIONS | | (2) NOT MORE THAN 48 IN. (1220 MM) ABOVE THE FINISHED | | FLOOR 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN | | THE DOOR LEAF WITH NOT MORE THAN ONE RELEASING | | OPERATION, UNLESS OTHERWISE SPECIFIED IN | | 7.2.1.5.10.3, 7.2.1.5.10.4, OR 7.2.1.5.10.6. | | | | | | FOR ASSEMBLY AND EDUCATIONAL OCCUPANCIES WITH AN | | OCCUPANT LOAD OF 100 OR MORE PERSONS (50 PERSONS PER | | THE FLORIDA BUILDING CODE), PANIC HARDWARE SHALL BE | | PROVIDED ON DOORS TO RELEASE THE LOCK/LATCH. NO OTHER | | LOCKS OR LATCHES ARE PERMITTED THAT WOULD NOT BE | | RELEASED BY THE PANIC HARDWARE. AS A SUBSTITUTE FOR | | PANIC HARDWARE, THE MAIN ENTRANCE IS PERMITTED TO HAVE | | AN INTERIOR KEYED DOOR LOCK (AND NO LATCH) WITH A | | READILY VISIBLE SIGN STATING THIS DOOR TO REMAIN | | UNLOCKED WHEN THE BUILDING IS OCCUPIED. SIGN LETTERS | | SHALL BE AT LEAST 1 INCH IN HEIGHT. KEYED LOCK TO BE | | EQUIPPED WITH AN ?OPEN/LOCKED? INDICATOR WINDOW (SUCH | | AS ADAMS RITE 4089 OR SIMILAR). A THUMB TURN STYLE LOCK | | IS NOT PERMITTED TO BE SUBSTITUTED FOR A KEYED LOCK. | | | | PLEASE ENSURE THAT EACH LOCKING DEVICE/SYSTEM COMPLIES | | WITH THE ABOVE REQUIREMENTS. | | | | | | | | 9) SHEET E 0.0.01 - THE LEGEND IS INDICATING FA | | DEVICES. THESE SYMBOLS/COMMENTS ARE CONFUSING AND ARE | | IN ADDITION TO # 2 ABOVE. | | | | IF THERE IS NO FIRE ALARM PROPOSED, NO REFENCES SHOULD | | BE INDICATED AND/OR REMOVED. | | | | | | | | 10) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | | | 11) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-03-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-03-02 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-02-05 |
Time |
11:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-09-07 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-09-07 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-05-19 |
Time |
14:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-04-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-25 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-23 |
Time |
12:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-03-02 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-03-02 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2016-12-27 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
N |
Date |
2017-08-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-08-15 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-06-07 |
Time |
10:38 |
Sent To |
|
|
Notes |
2017-08-15 14:15:22 | AUGUST 15/2017/ IMPACT FEE PLAN AT J. W. DESK | | | | PALM BEACH COUNTY IMPACT FEE ASSESSMENT 6/16/17 | | MU-2017-17039 | | 3008 SQUARE FEET | | USE: TENNIS CENTER | | FEES: NO FEES!!!!!! | | | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | 2017-06-07 12:14:22 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2017-06-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-04-10 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-04-10 |
Time |
|
Sent To |
|
|
Notes |
2017-06-07 10:38:09 | IMPACT FEES | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-01-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-20 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-18 |
Time |
13:58 |
Sent To |
|
|
Notes |
2017-01-20 15:39:39 | IMPACT FEES | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2018-02-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-02-16 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-02-16 |
Time |
15:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-06-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-06-01 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-06-01 |
Time |
16:47 |
Sent To |
|
|
Notes |
2017-06-01 17:11:35 | 3RD REVIEW FBC-2014 MECHANICAL | | PERMIT #16120880 | | 6/1/17 | | | | RESULTS: DENIED. | | | | COMMENTS FROM THE 2ND REVIEW PRINTED BELOW STILL EXIST. | | | | 1) AS PREVIOUSLY NOTED IN THE 1ST REVIEW, PROVIDE DUCT | | SMOKE DETECTORS IN THE RETURN AIR SYSTEM OF AC-1 & 2. | | | | 2) THE LOUVERED DOOR ENCLOSING THE MECHANICAL CLOSET | | FOR AC-1 MUST BE NON-COMBUSTIBLE PER SECTION C403.2.7.2 | | FBC-14 ENERGY CONSERVATION, AND SECTION 602.2.1 FBC-14 | | MECHANICAL. | | | | 3) SUBMIT TWO COPIES OF THE MIAMI-DADE NOA FOR THE | | LOUVER- #16-0201.03. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-03-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-28 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-03-28 |
Time |
13:43 |
Sent To |
|
|
Notes |
2017-03-28 14:01:33 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16120880 | | 3/28/17 | | | | 1) AS PREVIOUSLY NOTED IN THE 1ST REVIEW, PROVIDE DUCT | | SMOKE DETECTORS IN THE RETURN AIR SYSTEM OF AC-1 & 2. | | | | 2) THE LOUVERED DOOR ENCLOSING THE MECHANICAL CLOSET | | FOR AC-1 MUST BE NON-COMBUSTIBLE PER SECTION C403.2.7.2 | | FBC-14 ENERGY CONSERVATION, AND SECTION 602.2.1 FBC-14 | | MECHANICAL. | | | | 3) SUBMIT THE NOA #14-0414.08 FOR THE LOUVER. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-01-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-09 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-09 |
Time |
13:50 |
Sent To |
|
|
Notes |
2017-01-09 14:39:44 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16120880 | | 1/9/17 | | | | 1) THE 21 PERSON OCCUPANT DENSITY AND 163 CFMS OF O/A | | AIR DOES NOT APPEAR TO BE CONSISTENT WITH THE USE OF | | THE ROOM BASED ON THE OCCUPANT LOAD OF 151 INDICATED ON | | THE LIFE SAFETY PAGES. CLARIFY WHAT THE ROOM IS TO BE | | USED FOR AND SELECT THE CORRESPONDING VENTILATION RATE | | LISTED IN TABLE 403.3 OR ASHRAE 62.1-2010. | | | | 2) M-1.3.01: DUCT SMOKE DETECTORS ARE REQUIRED IN THE | | RETURN AIR SYSTEMS OF AC- 1 & 2 PER SECTION 606.2.1. | | PLEASE SHOW THE LOCATIONS OF THE DEVICES ON THE PLANS | | UNLESS IT CAN BE VERIFIED BY MANUFACTURER'S | | SPECIFICATIONS THAT THE SYSTEMS CANNOT EXCEED 2000 CFMS | | OF SUPPLY AIR. | | | | 3) M-1.3.01: PROVIDE AN AUTOMATIC SHUTOFF DAMPER FOR | | THE O/A TO AC-2 PER SECTION C403.2.4.4 FBC-14 ENERGY | | CONSERVATION. THE CURRENT PLAN SHOWS A "BD" NOT AN "MD" | | TO BE LOCATED IN THE DUCT. | | | | 4) M-1.3.01: PROVIDE THE FLEX DUCT SIZES. | | | | 5) M-1.3.01: PROVIDE A FL. PRODUCT APPROVAL OR | | MIAMI-DADE NOA FOR THE O/A AND EXHAUST LOUVERS. | | | | 6) M-3.0.00: THE AC SCHEDULE IS INDICATING "OFFICES" AS | | THE AREAS SERVED WHICH DOES NOT APPEAR TO BE CONSISTENT | | WITH THE PLANS. | | | | 7) PROVIDE FIRE DAMPER INSTALLATION DETAILS. | | | | 8) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION FOR | | THE EXTERIOR CODENSERS- SECTION 301.15 | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
N |
Date |
2017-01-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-20 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-18 |
Time |
13:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2018-02-28 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-28 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-28 |
Time |
10:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-06-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-06-15 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-06-15 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-04-25 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-04-25 |
Time |
11:23 |
Sent To |
|
|
Notes |
2017-04-25 11:33:37 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. THE REQUIRED DRINKING FOUNTAIN THAT WAS ADDED TO THE | | ARCHITECTURAL SHEETS WAS NOT ADDED TO ANY OF THE | | PLUMBING DRAWINGS CHECK ELECTRICAL ALSO PLEASE CLARIFY. | | PER WPB AMEND TO FBC 107.2.1 | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | COMMENTS. | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-01-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-24 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-23 |
Time |
12:50 |
Sent To |
|
|
Notes |
2017-01-24 09:43:04 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. SHT. A-0.0.02 THE PLUMBING FIXTURE COUNT IS CALLING | | THIS PROJECT AN A-2 IT SHOULD BE AN A-3 PLEASE CLARIFY | | . PER WPB AMEND TO FBC 107.2.1 | | | | 2. ARE THE RESTROOMS IN THE TENNIS CENTER SERVING THE | | TENNIS COURTS OCCUPANT LOAD IF SO INCLUDE IT IN THE | | FIXTURE COUNT IF NOT SHOW LOCATION OF BATHROOMS SERVING | | TENNIS COURTS. PER WPB AMEND TO FBC 107.2.1 | | | | 3. SHOW COMPLIANCE FOR TOILET PAPER DISPENSER PER FBC | | ACC 604.7 DISPENSERS. | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE | | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 | | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND | | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL | | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES | | NOT ALLOW CONTINUOUS PAPER FLOW. | | | | 4. SHOW COMPLIANCE FOR TOILET . PER FBC ACC 604.2 | | LOCATION. | | THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR | | PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE | | OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM | | TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR | | PARTITION, EXCEPT THAT THE WATER CLOSET SHALL BE 17 | | INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM | | FROM THE SIDE WALL OR PARTITION IN THE AMBULATORY | | ACCESSIBLE TOILET COMPARTMENT SPECIFIED IN 604.8.2. | | WATER CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR | | RIGHT-HAND APPROACH. | | | | 5. SHT. A-1.4.02 GENERAL NOTE AND ADA NOTES ARE UNCLEAR | | SOME OF THE WORDS ARE OVERLAPPING PLEASE CLARIFY. PER | | WPB AMEND TO FBC 107.2.1 | | | | 6. SHT. A-1.4.03 NOTES REFERENCE 2010 ADA AND 2012 FABC | | THIS PROJECT SHALL BE DESIGNED UNDER FBC ACC 2014 5TH | | ADDITION. PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 7. SHT. 1.4.04 IS MISSING WORDS AND FIGURE NUMBERS FOR | | EXAMPLE 403.5.2 CLEAR WIDTH AT ?, 404 DOORS DOORWAYS | | AND ? AND THE FIGURES ARE MISSING SEC NUMBERS PLEASE | | CLARIFY . PER WPB AMEND TO FBC 107.2.1 | | | | 8. A WATER FOUNTAIN IS REQUIRED PER FBC PL TABLE 403.1 | | AND SHALL COMPLY WITH FBC PL | | [B] 410.2 MINIMUM NUMBER. | | WHERE DRINKING FOUNTAINS ARE REQUIRED, NOT FEWER THAN | | TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING | | FOUNTAIN SHALL COMPLY WITH THE REQUIREMENTS FOR PEOPLE | | WHO USE A WHEELCHAIR AND ONE DRINKING FOUNTAIN SHALL | | COMPLY WITH THE REQUIREMENTS FOR STANDING PERSONS. | | AND FBC ACC 602 | | | | 9. ALL LAVATORY'S ARE REQUIRED TO HAVE TEMPERED WATER. | | PER FBC PL 416.5 TEMPERED WATER FOR PUBLIC HAND-WASHING | | FACILITIES. | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | 1070 OR CSA B125.3. | | | | 10. PLEASE PROVIDE NOT ON THE PLAN FOR SEPARATE PERMIT | | REQUIRED FOR THE BACKFLOW AT THE METER. PER WPB AMEND | | TO FBC 107.2.1 | | | | 11. SHUT OFF VALVES ARE REQUIRED ON THE HW FEEDS TO | | EACH BATHROOM. PER FBC PL 606.1(5) |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2018-03-02 |
|
|
Cont ID |
|
Sent By |
JR |
Date |
2018-03-02 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2018-03-02 |
Time |
11:42 |
Sent To |
|
|
Notes |
2018-03-02 11:50:33 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 03.02.2018 | | PERMIT NO.: 16120880 | | ___________________________________________ | | | | REVIEW STATUS: PASSED WITH PROVISOS | | ___________________________________________ | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. THIS PERMIT APPROVAL IS FOR THE TENNIS CENTER | | CLUBHOUSE ONLY. ALL SITE WORK, LANDSCAPING, SITE | | LIGHTING, ETC. SHALL BE REVIEWED/COMPLETED UNDER | | SEPARATE PERMIT APPLICATIONS. | | | | 2. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | ALL ASSOCIATED SITE WORK, LANDSCAPING, ETC. (PERMITTED | | SEPARATELY) SHALL BE COMPLETED AND PASS INSPECTION. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-09-07 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-09-07 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-09-07 |
Time |
10:44 |
Sent To |
|
|
Notes |
2017-09-07 10:45:09 | PROVISIO | | | | A CO ON THE TENNIS FACLITY WILL NOT BE ISSUED UNTIL ALL | | SITE IMPROVEMENTS (PARKING, ROADWAYS, LANDSCAPING, | | ETC.) WITHIN PHASE I OF THE PROJECT ARE COMPLETE. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2017-04-14 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-04-14 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-04-14 |
Time |
14:49 |
Sent To |
|
|
Notes |
2017-04-14 14:51:57 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 04.14.2017 | | PERMIT NO.: 16120880 | | ADDRESS: 3200 N CONGRESS AVENUE | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: | | SCOPE OF REVIEW: STRUCTURE ONLY FOR NEW CLUBHOUSE WITH | | UNDERGROUND PARKING | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | FROM ZONING'S PERSPECTIVE I DON'T HAVE ANY ISSUES WITH | | ISSUING A PERMIT TO BEGIN CONSTRUCTION OF THE TENNIS | | FACILITY; HOWEVER, THE TRAFFIC CONCURRENCY LETTER FROM | | PALM BEACH COUNTY AND THE DESIGN GUIDELINES FOR THE | | BANYAN CAY DEVELOPMENT PROVIDE THE FOLLOWING... | | | | "PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE | | DEVELOPER SHALL PROVIDE ACCEPTABLE SURETY TO THE PALM | | BEACH COUNTY TRAFFIC DIVISION, IN AN AMOUNT AS | | DETERMINED BY THE DIRECTOR OF THE PALM BEACH COUNTY | | TRAFFIC DIVISION." | | | | WE WILL NEED TO HAVE PROOF FROM THE COUNTY THAT THIS | | REQUIREMENT HAS BEEN SATISFIED BEFORE SIGNING OFF. | | PLEASE NOTE THAT THIS REQUIREMENT IS SEPARATE FROM ANY | | IMPACT FEES. | | | | ONCE THIS IS ADDRESSED I WILL BE ABLE TO SIGN OFF ON | | THE TENNIS FACILITY STRUCTURE ONLY, AS ALL SITE WORK, | | INCLUDING SURFACE PARKING, LANDSCAPING, SITE LIGHTING, | | ETC. WILL ALL NEED TO BE PERMITTED SEPARATELY. | | | | PLEASE KEEP IN MIND THAT A CO ON THE TENNIS FACLITY | | WILL NOT BE ISSUED UNTIL ALL IMPROVEMENTS WITHIN PHASE | | I OF THE PROJECT ARE COMPLETE. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-04-14 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-03-02 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-02-09 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |