Plan Review Stops For Permit 16120871 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-02-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-24 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-24 |
Time |
08:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-02-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-09 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-09 |
Time |
08:59 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-01-27 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-01-27 |
Time |
14:02 |
Sent To |
E |
|
Notes |
2017-01-27 14:11:28 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE SPECIFICATIONS FOR FOUNDATION (CONCRETE | | PSI). | | 2. DISSIMILAR METAL CONNECTION BETWEEN 4" STEEL SUPPORT | | AND 11/2" ALUMINUM ANGLE SADDLE. CONNECTION TO BE | | WELDED. PLEASE CLARIFY. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-02-21 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-21 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-21 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2017-02-10 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2017-02-10 |
Time |
07:38 |
Sent To |
I |
|
Notes |
2017-02-10 08:28:50 | ELECTRICAL REVIEW NOTES | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION FBC 2014, NFPA 70 2011 (NEC) & CITY | | AMENDMENTS TO THE 2015 FBC | | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | PROJECT NAME: 625 FLAGLER | | JOB ADDRESS: 625 FLAGLER | | DESCRIPTION: REPLACE EXISTING MONUMENT SIGN WITH NEW | | MASTER PERMIT: 16120871 | | | | | | PLANS FOR THE ABOVE MENTIONED PERMIT WERE REVIEWED FOR | | COMPLIANCE WITH THE CODES HEREIN DESCRIBED FOR THE | | SECOND TIME. FOLLOWING YOU WILL SEE NOTES ADDRESSING | | THE REQUIRED CORRECTIONS. ADDITIONAL CORRECTIONS MAY BE | | REQUIRED AFTER REVIEW OF YOUR RESUBMITTAL. | | | | 1. APPARENTLY NO ONE MADE AN EFFORT TO READ THE PRIOR | | ELECTRICAL REVIEW NOTES BECAUSE THE COMMENT WAS NOT | | ADDRESSED. THE CODE REQUIREMENTS AS MENTIONED ON THE | | PRIOR REVIEW NOTES SHALL BE ADHERED TO. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | MIKE ALBARRAN, CONTRACT ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH, PH. (561) 805-6746 | | EMAIL: [email protected] OR [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-30 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2017-01-30 |
Time |
16:01 |
Sent To |
|
|
Notes |
2017-01-30 16:14:04 | 1ST REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | 1] ADD A GENERAL ELECTRICAL NOTE THAT A DEDICATED 20 | | AMP CIRCUIT SHALL FEED THE SIGN. NEC 600.5 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-02-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-02-24 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-02-15 |
Time |
12:05 |
Sent To |
|
|
Notes |
2017-02-16 12:05:19 | RESUB ROUTED TO VPEREZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-02-10 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2017-02-10 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2017-01-31 |
Time |
11:43 |
Sent To |
|
|
Notes |
2017-02-10 08:36:18 | FAILED 2ND ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | NOTIFIED VIA EMAIL. FILE SENT TO SMALL DENIED "F" | | DRAWER. MA | 2017-02-01 11:43:18 | RESUB ROUTED TO KMARTIN VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-30 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-12-27 |
Time |
10:16 |
Sent To |
|
|
Notes |
2016-12-28 10:16:59 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-02-01 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-02-01 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2017-02-01 |
Time |
14:49 |
Sent To |
B |
|
Notes |
2017-02-01 13:37:00 | ROUTED TO KEVIN MARTIN |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-01-10 |
|
|
Cont ID |
|
Sent By |
|
Date |
2017-01-10 |
Time |
|
Rev Time |
0.00 |
Received By |
kmartin |
Date |
2017-01-10 |
Time |
10:42 |
Sent To |
B |
|
Notes |
2017-01-10 10:43:41 | NEW SIGN SHALL NOT EXCEED CURRENT SIZE (7? 3? X 5? 6 | | 3/8?). FOR MORE INFORMATION, PLEASE CONTACT KEVIN J | | MARTIN AT 561-822-1426 OR [email protected] | 2017-01-03 11:41:24 | ROUTED TO KEVIN MARTIN |
|
|