2017-01-31 10:28:34 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- PROVIDE PRODUCT APPROVAL FOR CASEMENT WINDOWS THAT | | MEET THE DESIGN PRESSURES CALCULATED BY THE ENGINEER OF | | RECORD. | | | | 2- PROVIDE PRODUCT APPROVAL FOR CASEMENT WINDOW SIZE | | THAT MEETS THE SIZE SPECIFIED ON WINDOW SCHEDULE FOR | | WINDOW #7 AND #8. | | | | 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | PRODUCT APPROVALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-01-30 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-01-30 |
Time |
11:41 |
Sent To |
|
|
Notes |
2017-01-30 12:20:41 | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- WINDOW CORNER DETAIL IS INCORRECT. PER MEETING WITH | | CONTRACTOR, THE CORNER IS CONCRETE BLOCK CONSTRUCTION | | NOT WOOD FRAMED CONSTRUCTION. REVISE AS REQUIRED TO | | MATCH ACTUAL CONDITIONS. SEC. R301.1 FBC-RESIDENTIAL, | | 5TH EDITION (2014). | | | | 2- STRUCTURAL CORNER DETAIL IS NOT CLEAR. A) WHAT ARE | | THE #6 TEK SCREW ATTACHING TO THE 3" STEEL COLUMN?. | | WHAT IS THE SIMPSON SPH4Z HOLDING? ENGINEER TO PROVIDE | | CALCULATIONS SHOWING HOW THE STRUCTURAL BUCK DETAIL IS | | TRANSFERRING THE LOADS TO THE 3" STEEL COLUMN? SEC. | | 107.2.1.3 CITY AMENDMENTS. | | | | 3- WINDOW SCHEDULE IS NOT CLEAR. CONTRACTOR SAYS THAT | | THERE ARE ONLY CASEMENT WINDOWS. THERE ARE NOT FIXED | | AND SINGLE HUNG WINDOWS. SEC. 107.2.1 CITY AMENDMENTS. | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR CASEMENT | | WINDOWS AS REQUIRED BY FAC61G20-3.002(33). | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (5610805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-12-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-12-27 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-12-27 |
Time |
15:06 |
Sent To |
|
|
Notes |
2016-12-27 15:22:11 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. | | 2. PROVIDE DESIGN WIND LOADS FOR WINDOW OPENINGS. | | 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE | | THEIR PRINTED NAME AND SIGNATURE ON THE PLAN PER FBC | | 107. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING, | | WINDOW, AND DOOR SUBMITTALS. | | | | FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-01-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-01-31 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-01-31 |
Time |
10:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-01-30 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-01-30 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-12-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-12-27 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-12-27 |
Time |
13:44 |
Sent To |
|
|
Notes |
2016-12-27 13:44:44 | BLDG -$5000 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |