Plan Review Details - Permit 16120787
Plan Review Stops For Permit 16120787
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-02-22 Cont ID  
Sent By jwitmer Date 2017-02-22 Time   Rev Time 0.00
Received By jwitmer Date 2017-02-22 Time 15:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-02-09 Cont ID  
Sent By jwitmer Date 2017-02-09 Time 16:16 Rev Time 0.00
Received By jwitmer Date 2017-02-09 Time 12:15 Sent To  
Notes
2017-02-09 16:16:22BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16120787 RESTROOM PAVILION
 ADD: 5100 N. HAVERHILL RD.
 CONT: STRATICON LLC
 TEL: 772-210-0700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: WED. JAN. 18/2016
 ACTION: DENIED
  
 1-2) COMPLIED.
  
 3) MISSING: 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) DOORS FIBERGLASS OUTSWING DOOR CORRIM CO. NO
 FLORIDA APPROVAL GENERAL NOTE # 1 TESTED IN ACCORDANCE
 WITH 2007 & 2010 FBC, NOT CURRENT.
 (C) WALL LOUVERS NOA 16-1107.01 OK
 (D) ROOFING ASSEMBLIES. 1 1/2 METAL DECKING AND
 STANDING SEAM METAL ROOF, SELF ADHERING UNDERLAYMENT
 2ND REVIEW ROOFING PRODUCT APPROVAL FOR THE METAL ROOF
 DECK.NOT STAMPED WITH DESIGNER OF RECORD SHOP DRAWING
 STAMP OF APPROVAL.
 2ND REVIEW POLYGLASS ROOF UNDERLAYMENT FL 5259- R25 NOT
 STAMPED WITH DESIGNER OF RECORD SHOP DRAWING STAMP OF
 APPROVAL.
  
 4) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5-6) COMPLIED.
  
 7) COMPLIED 2/14/17. SOILS REPORT.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-01-18 Cont ID  
Sent By jwitmer Date 2017-01-18 Time 16:57 Rev Time  
Received By jwitmer Date 2017-01-18 Time   Sent To  
Notes
2017-01-18 16:37:31BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16120787 RESTROOM PAVILION
 ADD: 5100 N. HAVERHILL RD.
 CONT: STRATICON LLC
 TEL: 772-210-0700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: WED. JAN. 18/2016
 ACTION: DENIED
  
 1) THERE ARE 2 PAVILIONS AND ONE BUILDING WITH
 RESTROOMS UNDER THE SAME ADDRESS. EACH BUILDING NEEDS
 IT OWN ADDRESS FOR IDENTIFICATION DURING CONSTRUCTION
 AS WELL AS FOR POLICE AND FIRE RESPONSE.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION OF THE PROJECT.
 CONTACT: MICHAEL ORIO GIS SUPPORT SPECIALIST/
 INFORMATION TECHNOLOGY
 TEL: 561-494-1040
 E-MAIL: [email protected]
  
 2) 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR
 BUILDINGS.
 107.3.5.1.1 COMMERCIAL BUILDINGS:
 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS
 SHALL BE DETERMINED.
 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED
 (SEE TABLE 503).
 8. STRUCTURAL REQUIREMENTS COLUMNS, BEAMS AN ROOF
 FRAMING MEMBERS, COMPONENTS AND CLADDING.
  
 3) MISSING: 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) DOORS
 (C) WALL LOUVERS
 (D) ROOFING ASSEMBLIES. 1 1/2 METAL DECKING AND
 STANDING SEAM METAL ROOF, SELF ADHERING UNDERLAYMENT
  
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
  
 4) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5) SHEET A-3.01 BUILDING SECTION. THE SECTION PLAN
 INDICATES FLOAT FINISH PLASTER CEILINGS. THE QUESTION
 IS ARE THE CEILINGS AND WALLS TO BE ACTUAL PLASTER OR
 ARE THEY GOING TO BE CEMENT PLASTER (STUCCO)? IF THE
 CEILINGS ARRE TO BE CEMENT PLASTER (STUCCO) THEN SHOW
 COMPLIANCE WITH 2014 FBC-B 2510.1 EXTERIOR AND INTERIOR
 CEMENT PLASTER AND LATHING SHALL BE DONE WITH THE
 APPROPRIATE MATERIALS LISTED IN TABLE 2507.2 AND
 CHAPTER 35. 2510.3 INSTALLATION. INSTALLATION OF THESE
 MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C 926 AND
 ASTM C 1063. PLEASE PROVIDE THE TYPE OF WIRE LATH,
 WEIGHT OF THE METAL PLASTER BASE AND THE MAXIUM
 PERMISSIBLE SPACING OF SUPPORTS ASSTM C1063.
  
 6) SHEET A-4.01 THE RESTROOM INTERIOR ELEVATIONS.
 PLEASE REVIEW THE WATER CLOSET GRAB BARS SHOW 36 INCHES
 CENTERLINED. PLEASE BE AWARE UNDER THE 2014
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BAR THE VERTICAL DIMENSION IS TAKEN FROM THE FLOOR TO
 THE TOP OF THE GRASPABLE SURFACE.
  
 7) MISSING SOILS REPORT, NOT SUBMITTED IN THIS REVIEW.
 2014 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE
 CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL
 IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO
 THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING
 OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A
 GEOTECHNICAL INVESTIGATION BE CONDUCTED.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-02-17 Cont ID  
Sent By vperez Date 2017-02-17 Time 10:23 Rev Time 0.00
Received By vperez Date 2017-02-17 Time 10:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-01-27 Cont ID  
Sent By vperez Date 2017-01-27 Time 12:03 Rev Time 0.00
Received By vperez Date 2017-01-27 Time 12:03 Sent To  
Notes
2017-01-27 12:03:41INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE
 PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE
 PERMITS AND DATA SPECIFICATION SHEET SUBMITTALS FOR ALL
 SITE LIGHTING AND ASSOCIATED EQUIPMENT, ALL LOW VOLTAGE
 SYSTEMS TO INCLUDE BUT NOT LIMITED TO FIRE ALARM,
 ACCESS CONTROLS (GATES), CCTV, PHONE AND DATA, WIRELESS
 SYSTEMS, ETC. LIFT STATION A NOTE WILL SUFFICE.
 2. PROVIDE A SHOW COMPLIANCE WITH FBC EC 405.7.3,
 405.7.4 SEE VERBIAGE IN THE CODE REGARDING VOLTAGE DROP
 AND COMPLETIONS DOCUMENTS.
 3. PLEASE SHOW AIC CALCULATION BASED ON INFORMATION
 PROVIDED BY FPL UTILITY FOR APPROVAL. NEC 110.24 FBC
 107.
 4. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO
 INDICATE NEC 110.16. ARC FLASH WARNING SIGNS AND NEC
 110.24- AVAILABLE FAULT CURRENT- FIELD MARKINGS; SEE
 VERBIAGE IN CODE.
 5. PROVIDE GENERAL NOTES FOR HIGH LEG MARKING TO COMPLY
 WITH NEC 110.15 AND NEC 408.3F1
 6. GFCI PROTECTION FOR EWC TO BE ACCESSIBLE, SHOW AT
 PANEL ON A GFCI BREAKER. NEC 210.8
 7. PLEASE ADD A GENERAL NOTE TO SHEET TO INDICATE THE
 REQUIREMENTS OF NEC 300.5D3 AND TABLE 300.5 FOR ALL
 UNDERGROUND WORK.
 8. ADDRESS FIRE, MECHANICAL AND BUILDING COMMENTS
 RELATED TO ELECTRICAL.
 9. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE
 TO CONTACT ME SHOULD YOU HAVE ANY
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2017-03-01 Cont ID  
Sent By skennedy Date 2017-03-01 Time 13:41 Rev Time 0.00
Received By skennedy Date 2017-03-01 Time 13:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-02-07 Cont ID  
Sent By wjolin Date 2017-02-07 Time 11:34 Rev Time 0.00
Received By wjolin Date 2017-02-07 Time 11:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-01-24 Cont ID  
Sent By wjolin Date 2017-01-24 Time 15:33 Rev Time 0.00
Received By wjolin Date 2017-01-24 Time 15:09 Sent To  
Notes
2017-01-24 15:33:435100 NORTH HAVERHILL ROAD
 PERMIT #16120787
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PER NFPA 1 SECTION 8.2.3.1.1 APPROVED FIRE DEPARTMENT
 ACCESS ROADS AND FIRE HYDRANTS SHALL BE PROVIDED FOR
 EVERY FACILITY, BUILDING, OR PORTION OF A BUILDING
 HEREAFTER CONSTRUCTED OR RELOCATED. A FIRE DEPARTMENT
 ACCESS ROAD SHALL EXTEND TO WITHIN 50 FEET OF AT LEAST
 ONE EXTERIOR DOOR THAT CAN BE OPENED FROM THE OUTSIDE
 AND THAT PROVIDES ACCESS TO THE INTERIOR OF THE
 BUILDING. WHEN BUILDINGS ARE PROTECTED THROUGHOUT WITH
 AN APPROVED AUTOMATIC SPRINKLER SYSTEM THAT IS
 INSTALLED IN ACCORDANCE WITH NFPA 13, THE DISTANCE
 SHALL BE PERMITTED TO BE INCREASED TO 450 FEET.
  
 PROVIDE SEPARATE ADDRESSES OR BUILDING IDENTIFICATIONS.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-03-10 Cont ID  
Sent By cpuell Date 2017-03-10 Time 09:34 Rev Time 0.00
Received By cpuell Date 2017-03-06 Time 13:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-03-06 Cont ID  
Sent By lmarchan Date 2017-03-06 Time 13:44 Rev Time 0.00
Received By lmarchan Date 2017-02-22 Time 11:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-02-21 Cont ID  
Sent By lmarchan Date 2017-02-21 Time 12:32 Rev Time 0.00
Received By lmarchan Date 2017-02-07 Time 09:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-01-27 Cont ID  
Sent By vperez Date 2017-01-27 Time 12:03 Rev Time 0.00
Received By vperez Date 2017-01-27 Time 12:05 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-01-18 Cont ID  
Sent By jwitmer Date 2017-01-18 Time   Rev Time 0.00
Received By jwitmer Date 2017-01-18 Time 15:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-02-08 Cont ID  
Sent By ccole Date 2017-02-08 Time 14:23 Rev Time 0.00
Received By ccole Date 2017-02-08 Time 14:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-01-24 Cont ID  
Sent By ccole Date 2017-01-24 Time 07:16 Rev Time 0.00
Received By ccole Date 2017-01-24 Time 07:16 Sent To  
Notes
2017-01-24 07:27:461ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16120787
 1/24/17
  
 1) REFER TO SECTION 404.2 AND PROVIDE CODE COMPLIANT
 NATURAL VENTILATION CALCULATIONS FOR THE STORAGE ROOM,
 THE MEN/WOMEN'S RESTROOMS, AND THE SERVICE/PUMP ROOM.
  
 2) REFER TO SECTION 309.1 AND PROVIDE A SPACE HEATING
 SYSTEM FOR THE MAINTENANCE/STORAGE ROOM. PLEASE INCLUDE
 SYSTEM SIZING CALULATIONS PER SECTION C403.2.1 FBC-14
 ENERGY CONSERVATION.
  
 3) PROVIDE DOCUMENTATION OF ENERGY CONSERVATION
 COMPLIANCE PER SECTION C101.2 AND C401.2.
  
 4) PROVIDE DETAILS FOR ATTACHMENT OF THE FANS AND FAN
 CURBS TO THE ROOF STRUCTURE- SECTION 301.15.
  
 5) SUBMIT A FL. PRODUCT APPROVAL AND/OR MIAMI-DADE NOA
 FOR THE WALL LOUVERS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2017-03-10 Cont ID  
Sent By tklarge Date 2017-03-10 Time 08:50 Rev Time 0.00
Received By tklarge Date 2017-03-10 Time 06:14 Sent To  
Notes
2017-03-10 08:51:57PLUMBING SIGNATURE VERIFIED.

Review Stop P PLUMBING
Rev No 3 Status F Date 2017-02-27 Cont ID  
Sent By tklarge Date 2017-02-27 Time 12:26 Rev Time 0.00
Received By tklarge Date 2017-02-27 Time 04:29 Sent To  
Notes
2017-02-27 12:26:251) SHT. L2.10 - DETAIL #5 - THESE DRINKING FOUNTAINS
 SHALL COMPLY WITH 2014 FBC -ACCESSIBILITY SEC.211.1.
 WHERE MORE THAN THE MINIMUM NUMBER OF DRINKING
 FOUNTAINS SPECIFIED IN SEC.211.2 ARE PROVIDED, 50
 PERCENT OF THE TOTAL NUMBER OF DRINKING FOUNTAINS
 PROVIDED SHALL COMPLY WITH FAC SEC.602.1 THROUGH 602.6
 AND 50 PERCENT OF THE TOTAL NUMBER OF DRINKING
 FOUNTAINS PROVIDED SHALL COMPLY WITH SEC. 602.7. PER
 THE MANUFACTURER'S WEBSITE, THE MODEL OF THE DRINKING
 FOUNTAIN SPECIFIED IN DETAIL #5 DOES NOT COMPLY WITH
 THE PREVIOUS REFERENCED CODE SECTIONS.
 2) SHT. L2.10 - DETAIL #9 - THE SPECIFIED SHOWER SHALL
 COMPLY WITH 2014 FBC-ACCESSIBILITY SEC.213.3.6. PER THE
 MANUFACTURER'S WEBSITE, THE MODEL OF THE SHOWER
 SPECIFIED IN DETAIL #9 DOES NOT COMPLY WITH THE FAC.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-02-07 Cont ID  
Sent By tklarge Date 2017-02-07 Time 05:26 Rev Time 0.00
Received By tklarge Date 2017-02-07 Time 03:16 Sent To  
Notes
2017-02-07 03:27:571) THE NARRATIVE RESPONSE TO PLUMBING REVIEW COMMENT #
 1 REFERS TO DETAIL 1 / SHT.A-1.01 FOR TOILET STALL
 DIMENSIONS. I COULD NOT FIND ANY OF THE REQUESTED
 INFORMATION/ DIMENSIONS ON DETAIL 1 / SHT. A-1.01 -
 CLARIFY.THE REQUIRED DIMENSIONS OF THE STANDARD TOILET
 STALLS SHALL BE A MINIMUM OF 30 INCHES WIDE BY 60
 INCHES DEEP PER 2014 FBC-PLUMBING SEC.405.3.1. 2ND
 REQUEST. NOTE: I FOUND A STALL DIMENSION ON SHT.A-4.01
 IN THE MEN'S TOILET ROOM. PLEASE NOTE THIS AS A TYPICAL
 DIMENSION FOR THE STANDARD STALLS.
 2) PLUMBING PLAN REVIEW COMMENT # 3 - THE NARRATIVE
 RESPONSE TO PLUMBING REVIEW COMMENT #3 REFERS TO
 DETAILS # 1 & # 2 ON SHT. A-1.01. DETAIL # 2 SHOWS A
 GAZEBO WITH NO PLUMBING FIXTURES IN IT SO I HAVE NO
 IDEA WHAT THIS RESPONSE APPLIES TO. DETAIL #1 DOES NOT
 PROVIDE THE REQUIRED INFORMATION. COMPLY WITH 2014
 FBC-ACCESS. SECS.604.5, 604.5.1, & 604.5.2.ALSO, REFER
 TO FIGURES 604.5.1 & 604.5.2.YOU WILL FIND THE
 REQUESTED INFORMATION IN THESE FIGURES. 2ND REQUEST.
 3) SHT. A-4.01 SHOWS THE HANDICAPPED ACCESSIBLE TOILET
 COMPARTMENTS AS 7'-0". THE MINIMUM WIDTH SHALL BE 7'-1"
 IF BUILT PERFECT. 7'-2" ALLOWS FOR CONSTRUCTION
 TOLERANCES.
 4) SHT.A-1.01 SHOWS A CLOUDED REFERENCE TO DETAIL # 3 /
 SHT. A-1.01. THERE IS NO SUCH DETAIL ON A-1.01. PLEASE
 REVISE WITH THE CORRECT SHEET, SHT. A-4.01.
 5) PLUMBING PLAN REVIEW COMMENT #5 - THE NARRATIVE
 RESPONSE REFERS TO DETAIL #3/SHT. A-2.01 FOR THE
 DRINKING FOUNTAINS. THERE IS NO DETAIL #3 ON THIS SHEET
 AND THE REQUIRED KNEE AND TOE CLEARANCES ARE NOT SHOWN.
 CLARIFY. 2ND REQUEST. SHOW THE REQUIRED KNEE AND TOE
 CLEARANCE FOR THE DRINKING FOUNTAIN PER 2014
 FBC-ACCESS. SEC.306. 2ND REQUEST. I FOUND THE DRINKING
 FOUNTAIN ELEVATIONS ON SHT. A-3.01. PLEASE CORRECT THE
 REFERENCE SHEET.
 6) SHT. E1.1 REFERS TO A LIFT STATION. SUBMIT COMPLETE
 DETAILS FOR THE LIFT STATION INCLUDING PIPING DETAILS,
 WHERE AND HOW THE STATION CONNECTS TO THE MAIN SANITARY
 SYSTEM. WPB AMEND. TO FBC SEC. 107.2.1.THE NARRATIVE
 RESPONSE STATES THAT THE CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT IS PERFORMING A REVIEW
 OF THE LIFT STATION THIS IS FINE BUT THE PLANS/ SPECS
 AND DETAILS MUST ALSO BE REVIEWED BY THE PLUMBING
 SECTION OF THE CONSTRUCTION SERVICES DIVISION AS THE
 2014 FBC-PLUMBING SEC.712 APPLIES TO THIS INSTALLATION
 AND THEREFORE MUST BE REVIEWED FOR COMPLIANCE. 2ND
 REQUEST.
 7) FLOOR PLANS SHOW A SERVICE/PUMP ROOM. SUBMIT DETAILS
 FOR THE PUMP & PIPING THAT WILL BE INSTALLED. PB AMEND.
 TO FBC SEC. 107.2.1.
 8) SHT. FSP - SITE PLAN KEY LISTS A TOTAL OF THREE
 DRINKING FOUNTAINS BUT ONLY THE DRINKING FOUNTAINS AT
 THE MAIN PAVILLION ARE SHOWN ON THE SANITARY AND WATER
 RISERS. CLARIFY.REFER TO THE DRINKING FOUNTAIN BY THE
 SHADE STRUCTURE AT THE PLAYGROUND.
 9) SHUTOFF VALVES SHALL BE INSTALLED ON ALL WALL
 HYDRANTS / HOSE BIBBS. 2014 FBC-PLUMBING SEC.606.2 (
 2).
 10) A FULL - OPEN VALVE SHALL BE INSTALLED ON THE WATER
 SUPPLY PIPE TO THE WATER HEATER. 2014 FBC-PLUMBING
 SEC.606.1 (8).
 11) IF THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER
 PIPING EXCEEDS 50 FEET FROM THE SOURCE OF HOT WATER TO
 THE FIXTURES THAT REQUIRE HOT OR TEMPERED WATER, A HOT
 WATER RECIRCUATING LINE SHALL BE REQUIRED. 2014
 FBC-PLUMBING SEC.607.2.
 12) THE APPROVED SITE PLAN AND SHT. C3.02 SHOW A SPLASH
 PAD AND A SHOWER. IF THESE WILL BE DONE UNDER A
 SEPARATE PERMIT PLEASE NOTE SUCH ON THE PLAN.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-01-21 Cont ID  
Sent By tklarge Date 2017-01-21 Time 07:20 Rev Time 0.00
Received By tklarge Date 2017-01-21 Time 05:29 Sent To  
Notes
2017-01-21 07:20:141) THE REQUIRED DIMENSIONS OF THE STANDARD TOILET
 STALLS SHALL BE A MINIMUM OF 30 INCHES WIDE BY 60
 INCHES DEEP PER 2014 FBC-PLUMBING SEC.405.3.1.
 2) SHT. A-4.01 & A-4.02 - THE GRAB BARS SHALL BE
 MEASURED FROM THE FINISH FLOOR TO THE TOP OF THE
 GRIPPING SURFACE, NOT TO THE CENTERLINE. 2014
 FBC-ACCESS. SEC. 609.4.
 3) THE PLACEMENT OF THE SIDE AND REAR GRAB BARS FOR THE
 WATER CLOSETS SHALL COMPLY WITH 2014 FBC-ACCESS.
 SEC.604.5, 604.5.1, 604.5.2.
 4) SHOW THE INSIDE CLEAR DIMENSIONS (LXW) OF THE
 ACCESSIBLE TOILET STALLS.COMPLY WITH 2014 FAC SEC.604.
 5) SHOW THE REQUIRED KNEE AND TOE CLEARANCE FOR THE
 DRINKING FOUNTAIN PER 2014 FBC-ACCESS. SEC.306.
 6) INDICATE THE CAPACITY OF THE EXPANSION TANK ON THE
 PLANS.
 7)FLOOR PLANS SHOW A SERVICE/PUMP ROOM. SUBMIT DETAILS
 FOR THE PUMP & PIPING THAT WILL BE INSTALLED. PB AMEND.
 TO FBC SEC. 107.2.1.
 8) SHT. P-3 -SIZE ALL THE WET SECTIONS OF THE WASTE
 STACKS.
 9) THE FLOOR DRAINS LOCATED IN THE SERVICE/PUMP ROOM,
 THE WOMEN'S RESTROOM AND THE MEN'S RESTROOM APPEAR TO
 EXCEED THE MAXIMUM DISTANCE OF THE TRAP TO A VENT PER
 2014 FBC-PLUMBING TABLE 909.1.
 10) SHT. E1.1 REFERS TO A LIFT STATION. SUBMIT COMPLETE
 DETAILS FOR THE LIFT STATION INCLUDING PIPING DETAILS,
 WHERE AND HOW THE STATION CONNECTS TO THE MAIN SANITARY
 SYSTEM. WPB AMEND. TO FBC SEC. 107.2.1.
 11) PLEASE EXPLAIN HOW YOU ARRIVED AT THE NUMBER OF
 SANITARY FACILITIES REQD. FOR THIS TYPE OF OCCUPANCY.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2017-03-10 Cont ID  
Sent By tklarge Date 2017-03-10 Time 08:51 Rev Time 0.00
Received By tklarge Date 2017-03-10 Time 08:51 Sent To  
Notes
2017-03-10 08:52:29PLUMBING SIGNATURE VERIFIED. TKL.
2017-01-27 12:05:09ELEC VERIFIED
2017-01-18 16:54:2201/18/2017 ARCHITECTURAL & STRUCTURAL SHEETS SIGNATURES
 REVIEWED/ GOOD. JW
 02/22/2017 ARCHITECTURAL & STRUCTURAL SHEETS SIGNATURES
 REVIEWED/ GOOD. JW
  

Review Stop Z ZONING
Rev No 1 Status P Date 2017-01-24 Cont ID  
Sent By ajones Date 2017-01-24 Time 11:10 Rev Time 0.00
Received By ajones Date 2017-01-24 Time 11:10 Sent To  
Notes
***NONE***