Plan Review Details - Permit 16120632
Plan Review Stops For Permit 16120632 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-12-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-12-21 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-21 |
Time |
09:37 |
Sent To |
|
|
Notes |
2016-12-21 10:04:22 | BUILDING PROVISO: | | | | SHEETS A1.1.1 & A2.0 ARE MISSING SAFETY GLAZING NOTES, | | RED LINED!!!!! | | 1) REQUIREMENTS FOR SAFETY GLAZING FBC-B 2406.4 | | 2) FBC-B 2406.4.1 GLAZING IN DOORS | | 3) FBC-B 2406.4.2 GLAZING ADJACENT TO DOORS. | | | | JAMES A. WITMER BN, PX,CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-01-09 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-09 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2017-01-09 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-12-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-12-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-12-22 |
Time |
12:36 |
Sent To |
|
|
Notes |
2016-12-22 12:41:21 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) SHEET ALS 1.1 - THERE IS NO INDICATION OF FIRE | | SPRINKLER OR FIRE ALARM WORK. | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | CONSTRUCTION PERIOD. | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | AND COMPLETE PROTECTION IS RETURNED. | | | | | | | | 2) SHEET E 2.1 - THERE IS NO EXIT SIGN AT THE NEW DOOR | | 100 LOCATION LEADING TO THE EXISTING EXIT. | | | | PLEASE ADD A NEW EXIT SIGN AT THAT LOCATION LEADING TO | | THE EXISTING EXIT. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-01-09 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-09 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-12-16 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2016-12-21 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-21 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-01-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-01-17 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-01-17 |
Time |
11:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-12-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-28 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-28 |
Time |
11:58 |
Sent To |
|
|
Notes |
2016-12-28 12:02:52 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16120632 | | 12/28/16 | | | | 1) M2.1: SHOW THE BRANCH DUCT SIZES FROM THE EXISTING | | TRUNKS TO THE NEW VAV BOXES, AND THE FLEX DUCT SIZES. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-01-09 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-09 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-09 |
Time |
13:58 |
Sent To |
|
|
Notes |
|
|
|