Plan Review Details - Permit 16120537
Plan Review Stops For Permit 16120537
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-12-29 Cont ID  
Sent By jwitmer Date 2016-12-29 Time 07:28 Rev Time 0.00
Received By jwitmer Date 2016-12-29 Time 07:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-12-20 Cont ID  
Sent By rlecky Date 2016-12-20 Time 13:48 Rev Time 0.00
Received By rlecky Date 2016-12-20 Time 13:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-12-22 Cont ID  
Sent By pleduc Date 2016-12-22 Time   Rev Time 0.00
Received By pleduc Date 2016-12-21 Time 14:16 Sent To  
Notes
2016-12-22 10:16:47THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) SHEET T - THERE ISAN INCORRECT REFERENCE TO THE
 CURRENT EDITION OF THE FIRE CODE.
  
 THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE
 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER
 APPLICABLE CODES OR STANDARDS.
  
 PLEASE ENSURE COMPLIANCE AND UPDATE YOUR RECORDS FOR
 FUTURE SUBMITTALS.
  
  
  
 2) SHEET A 7 - ANY AND ALL WORK ON THE FIRE ALARM
 SYSTEM SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
 PLEASE ENSURE COMPLIANCE
  
  
  
 3) SHEET E 2.1 - THERE ARE 2 EXITS SIGNS INDICATED
 OUTSIDE A CORRIDOR THAT WOULD BE BETTER ERVED INSIDE
 THE CORRIDOR.
  
 PLEASE SEE THE HAND WRITTEN NOTE ON PLAN SHEET TO
 RELOCATE THEM.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-01-25 Cont ID  
Sent By ccole Date 2017-01-25 Time 07:26 Rev Time 0.00
Received By ccole Date 2017-01-23 Time 15:19 Sent To  
Notes
2017-01-24 15:19:45RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-01-11 Cont ID  
Sent By gjohnson Date 2017-01-11 Time 17:08 Rev Time 0.00
Received By gjohnson Date 2016-12-14 Time 11:10 Sent To  
Notes
2016-12-15 11:10:13C14

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-12-29 Cont ID  
Sent By jwitmer Date 2016-12-29 Time 07:01 Rev Time 0.00
Received By jwitmer Date 2016-12-29 Time 07:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-01-25 Cont ID  
Sent By ccole Date 2017-01-25 Time 07:26 Rev Time 0.00
Received By ccole Date 2017-01-25 Time 06:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-12-28 Cont ID  
Sent By ccole Date 2016-12-28 Time 08:12 Rev Time 0.00
Received By ccole Date 2016-12-28 Time 08:12 Sent To  
Notes
2016-12-28 08:31:011ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16120537
 12/28/16
  
 1) PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW AND
 EXISTING VAV BOXES.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-01-11 Cont ID  
Sent By gjohnson Date 2017-01-11 Time 17:08 Rev Time 0.00
Received By gjohnson Date 2017-01-11 Time 17:08 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved