Plan Review Details - Permit 16120537
Plan Review Stops For Permit 16120537 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2016-12-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-12-29 |
Time |
07:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-29 |
Time |
07:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-12-20 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2016-12-20 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2016-12-20 |
Time |
13:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-12-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-12-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-12-21 |
Time |
14:16 |
Sent To |
|
|
Notes |
2016-12-22 10:16:47 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | | | 1) SHEET T - THERE ISAN INCORRECT REFERENCE TO THE | | CURRENT EDITION OF THE FIRE CODE. | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | APPLICABLE CODES OR STANDARDS. | | | | PLEASE ENSURE COMPLIANCE AND UPDATE YOUR RECORDS FOR | | FUTURE SUBMITTALS. | | | | | | | | 2) SHEET A 7 - ANY AND ALL WORK ON THE FIRE ALARM | | SYSTEM SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | AND COMPLETE PROTECTION IS RETURNED. | | | | PLEASE ENSURE COMPLIANCE | | | | | | | | 3) SHEET E 2.1 - THERE ARE 2 EXITS SIGNS INDICATED | | OUTSIDE A CORRIDOR THAT WOULD BE BETTER ERVED INSIDE | | THE CORRIDOR. | | | | PLEASE SEE THE HAND WRITTEN NOTE ON PLAN SHEET TO | | RELOCATE THEM. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-01-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-25 |
Time |
07:26 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-23 |
Time |
15:19 |
Sent To |
|
|
Notes |
2017-01-24 15:19:45 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-11 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-12-14 |
Time |
11:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2016-12-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-12-29 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-29 |
Time |
07:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2017-01-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-25 |
Time |
07:26 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-25 |
Time |
06:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-12-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-28 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-28 |
Time |
08:12 |
Sent To |
|
|
Notes |
2016-12-28 08:31:01 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16120537 | | 12/28/16 | | | | 1) PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW AND | | EXISTING VAV BOXES. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-11 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-11 |
Time |
17:08 |
Sent To |
|
|
Notes |
|
|
|