Plan Review Stops For Permit 16120133 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2017-03-01 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-03-01 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-03-01 |
Time |
16:19 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-02-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-02-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-02-23 |
Time |
11:51 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-01-03 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-01-03 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-12-30 |
Time |
16:11 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-12-20 |
|
|
Cont ID |
|
Sent By |
J.Walker |
Date |
2016-12-20 |
Time |
|
Rev Time |
0.15 |
Received By |
|
Date |
2016-12-19 |
Time |
|
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-03-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-02 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-27 |
Time |
11:35 |
Sent To |
|
|
Notes |
2017-02-28 11:36:06 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-02-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-02-24 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-09 |
Time |
11:51 |
Sent To |
|
|
Notes |
2017-02-10 11:51:48 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-01-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-03 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-30 |
Time |
10:40 |
Sent To |
|
|
Notes |
2016-12-30 10:41:07 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-12-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-27 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-05 |
Time |
10:32 |
Sent To |
|
|
Notes |
2016-12-06 10:33:02 | ROUTED TO FIRE INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-03-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-02 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-03-02 |
Time |
09:36 |
Sent To |
|
|
Notes |
2017-03-02 10:32:34 | MECHANICAL PROVISO: | | | | GUARDS SHALL BE PROVIDED WHERE ANY FANS OR EQUIPMENT | | ARE LOCATED WITHIN 10' OF ROOF EDGES- SECTION 304.11 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-02-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-02-24 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-24 |
Time |
12:15 |
Sent To |
|
|
Notes |
2017-02-24 12:19:08 | 3RD REVIEW FBC-2014 MECHANICAL | | PERMIT #16120133 | | 2/24/17 | | | | 1) PLEASE REMOVE THE FIRE SUPPRESSION PLANS AND THE M-1 | | PLAN FROM THE PLAN SETS. THIS PERMIT APPLICATION IS | | SOLEY FOR THE KITCHEN EXHAUST HOOD. A SEPARATE PERMIT | | IS REQUIRED FOR THE FIRE SUPPRESSION SYSTEM, AND THE | | REVISED M-1 PLAN SHEET MUST BE SUBMITTED AS A REVISION | | OT MASTER PERMIT #16040451. | | | | 2) THE SUBMITTED KITCHEN EXHAUST PLANS APPEAR TO COPIES | | FROM AN ORIGINAL SET AND MUCH OF THE PRINT IS | | ILLEGIBLE. I HAVE SPOKEN WITH LORI FROM HOOD DEPOT AND | | THEY ARE READY TO RESUBMIT CLEAR, CORRECTED, SIGNED AND | | SEALED PLANS ADDRESSING THE PREVIOUS REVIEW COMMENT ON | | 1/03/2017. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-01-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-03 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-03 |
Time |
09:34 |
Sent To |
|
|
Notes |
2017-01-03 09:41:04 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16120133 | | 1/3/17 | | | | 1) COMMENT #2 FROM THE 1ST REVIEW STILL EXISTS. PLEASE | | PROVIDE AN AC LOAD CALCULATION THAT INCLUDES THE | | ADDITIONAL HEAT GAIN FROM THE MAKEUP AIR, AND THAT | | INDICATES THE ADDITIONAL LOAD DOES NOT EXCEED THE | | CAPACITY OF THE EXISTING OR PROPOSED AC SYSTEM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-12-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-27 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-27 |
Time |
12:09 |
Sent To |
|
|
Notes |
2016-12-27 12:25:02 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16120133 | | 12/27/16 | | | | 1) THE 1" CLEARANCE FOR THE HOOD TO THE COMBUSTIBLE | | CEILING AND WALLS IS NOT PERMITTED PER TABLE 308.6 | | FBC-14 MECHANICAL, AND NFPA-96 SECTION 4.2.3.2, TABLE | | A.3.3.37, AND FIGURE A.4.2(H). PLEASE CORRECT THE | | PLANS. | | | | 2) INDICATE COMPLIANCE WITH SECTION 508.1.1 MAKEUP AIR | | TEMPERATURE. | | | | 3) IT APPEARS THAT GURADS WILL BE REQUIRED AT THE ROOF | | EDGE THAT IS SHOWN IN CLOSE PROXIMITY TO THE EXHAUST | | FAN ON SHEET 4- SEE SECTION 304.11. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|