Plan Review Details - Permit 16111134
Plan Review Stops For Permit 16111134 |
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2016-12-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-14 |
Time |
09:36 |
Rev Time |
|
Received By |
ccole |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-12-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-14 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-12-01 |
Time |
14:11 |
Sent To |
M |
|
Notes |
2016-12-01 14:15:41 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | | | 1) THERE ARE 43 NEW HEADS AND NEW PIPING THAT IS MORE | | THAN RELOCATED DROPS. | | | | PER NFPA 13, ISOLATE AND TEST AT 200PSI FOR 2 HRS. | | | | 24.2 ACCEPTANCE REQUIREMENTS. | | 24.2.1* HYDROSTATIC TESTS. | | 24.2.1.1 UNLESS PERMITTED BY 24.2.1.2 THROUGH 24.2.1.8, | | ALL PIPING AND ATTACHED APPURTENANCES SUBJECTED TO | | SYSTEM WORKING PRESSURE SHALL BE HYDROSTATICALLY TESTED | | AT 200 PSI (13.8 BAR) AND SHALL MAINTAIN THAT PRESSURE | | WITHOUT LOSS FOR 2 HOURS. | | 24.2.1.2 PORTIONS OF SYSTEMS NORMALLY SUBJECTED TO | | SYSTEM WORKING PRESSURES IN EXCESS OF 150 PSI (10.4 | | BAR) SHALL BE TESTED AS DESCRIBED IN 24.2.1.1, AT A | | PRESSURE OF 50 PSI (3.5 BAR) IN EXCESS OF SYSTEM | | WORKING PRESSURE. | | 24.2.1.4 MODIFICATIONS AFFECTING 20 OR FEWER SPRINKLERS | | SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING | | PRESSURE. | | 24.2.1.5 WHERE ADDITION OR MODIFICATION IS MADE TO AN | | EXISTING SYSTEM AFFECTING MORE THAN 20 SPRINKLERS, THE | | NEW PORTION SHALL BE ISOLATED AND TESTED AT NOT LESS | | THAN 200 PSI (13.8 BAR) FOR 2 HOURS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-12-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-15 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-14 |
Time |
09:28 |
Sent To |
|
|
Notes |
2016-12-15 09:29:04 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-12-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-14 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-28 |
Time |
17:13 |
Sent To |
FIRE |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-12-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-15 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-15 |
Time |
11:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-12-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-14 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-14 |
Time |
09:36 |
Sent To |
|
|
Notes |
2016-12-14 09:41:08 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16111134 | | 12/14/16 | | | | 1) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN- SECTION 107.2.1 | | WPB AMENDMENTS TO THE FBC. IN LIEU OF DESIGNER | | SIGNATURE, A SHOP DRAWING APPROVAL BY THE ENGINEER OF | | RECORD FOR THE MAIN PROJECT IS ACCEPTABLE, | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
|