Plan Review Stops For Permit 16110835 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-03-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-03-02 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-03-02 |
Time |
08:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-01-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-25 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-25 |
Time |
09:02 |
Sent To |
|
|
Notes |
2017-01-25 10:25:42 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16110835 | | ADD: 1142 OKEECHOBEE RD. | | CONT: MASTER CONTRACTORS | | TEL: 561-248-5498 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 2NDD REVIEW | | DATE: WED. JAN. 25/2017 | | ACTION: DENIED | | | | 1-2) COMPLIED. | | | | 3) SHEET A1 OF 13 SHOWS THE BREWERY AND THE ADJACENT | | BEER DRINKING AREA WITH A HALF WALL UNDER COUNTER. | | PLEASE SHOW COMPLIANCE WITH: | | | | 3A) SEMI-COMPLIED. SHEET A1 SHOWS A DIFFERENT LAYOUT | | THAN SHEET EQ-1. 2014 ACCESSIBILITY CODE 226.1 WHERE | | DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION OF | | FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING SPACES | | AND STANDING SPACES AT THE DINING SURFACES SHALL COMPLY | | WITH 902. | | | | 3B) SEMI-COMPLIED. SHEET A1 SHOWS A DIFFERENT LAYOUT | | THAN SHEET EQ-1. 2014 ACCESSIBILITY CODE 226.2 | | DISPERSION. DINING SURFACES REQUIRED TO COMPLY WITH 902 | | SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY | | CONTAINING DINING SURFACES. | | | | 3C) 2ND REQUEST THE ACCESSIBLE TABLE HEIGHTS ARE | | UNKNOWN. 2014 ACCESSIBILITY CODE. 902.3 HEIGHT. THE | | TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE 28 | | INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) MAXIMUM | | ABOVE THE FINISH FLOOR OR GROUND. | | | | 3D) COMPLIED. COUNTER HEIGHT. 36 INCHES. | | | | 4) 2ND REQUEST. SHEET A-1 INDICATES AN EXISTING 5 TON | | HEAT PUMP UNDER A DIFFERENT PERMIT. PLEASE PROVIDE THE | | PERMIT NUMBER FOR THE HEAT PUMP BEING INSTALLED IN THIS | | BAY, (BAY 12/13). THE CITY RECORDS ONLY SHOW A 5 TON | | HEAT PUMP BEING INSTALLED IN BAY # 6 UNDER PERMIT | | 08060846. | | | | | | THE PLANS SHEET A-1 NOTE 2 INDICATES THE GARAGE DOORS | | ARE TO BE OPEN DURING BUSINESS HOURS FOR VENTILATION | | AND NOTE 3 INDICATES THERE IS TO BE NO MECHANICAL WORK. | | PLEASE PROVIDE HOW COMPLIANCE WITH | | 1204.1 EQUIPMENT AND SYSTEMS FBC-B WILL BE COMPLIED | | WITH. | | 2014 FBC-B 1204.1 EQUIPMENT AND SYSTEMS. INTERIOR | | SPACES INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED | | WITH ACTIVE OR PASSIVE SPACE-HEATING SYSTEMS CAPABLE OF | | MAINTAINING AN INDOOR TEMPERATURE OF NOT LESS THAN 68?F | | (20?C) AT A POINT 3 FEET (914 MM) ABOVE THE FLOOR ON | | THE DESIGN HEATING DAY. | | | | 5) COMPLIED. PALM BEACH COUNTY IMPACT FEES. | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-12-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2016-12-05 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-05 |
Time |
09:05 |
Sent To |
|
|
Notes |
2016-12-05 11:36:24 | BUILDING PLAN REVIEW | | W. P. B. PERMIT: 16110835 | | ADD: 1142 OKEECHOBEE RD. | | CONT: MASTER CONTRACTORS | | TEL: 561-248-5498 | | E-MAIL: [email protected] | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: MON. DEC. 05/2016 | | ACTION: DENIED | | | | 1A)NEITHER THE PLANS NOR THE PERMIT APPLICATION | | INDICATE WHAT SUITE NUMBER THE SCOPE OF WORK TO BE | | COMPLETED UNDER THIS PERMIT. | | | | 1B) THIS APPEARS TO BE A CHANGE IN OCCUPANCY NEITHER | | THE PLANS NOR PERMIT APPLICATION INDICATE AS SUCH? | | 2014 FBC-EXISTING BUILDING. 1001.3.1 PARTIAL CHANGE OF | | OCCUPANCY CLASSIFICATION. WHERE A PORTION OF AN | | EXISTING BUILDING IS CHANGED TO A NEW OCCUPANCY | | CLASSIFICATION, SECTION 1012 SHALL APPLY. | | | | 2) SHEET A1 OF 13 SHOWS THE BREWERY AND THE ADJACENT | | BEER DRINKING AREA WITH A HALF WALL UNDER COUNTER. | | THE PLANS DO NOT SHOW HOW COMPLIANCE WITH SECTION | | 1210.4 TOILET ROOM LOCATION, 2014 FBC-B. 1210.4. TOILET | | ROOMS SHALL NOT OPEN DIRECTLY INTO A ROOM USED FOR THE | | PREPARATION OF FOOD FOR SERVICE TO THE PUBLIC. THE | | BREWERY IS CONSIDERED A COMMERCIAL KITCHEN AND THERE | | ARE NO WALLS SEPARATING THE COMMERCIAL KITCHEN FROM THE | | RESTROOM, NOR VESTIBULE. | | | | 3) SHEET A1 OF 13 SHOWS THE BREWERY AND THE ADJACENT | | BEER DRINKING AREA WITH A HALF WALL UNDER COUNTER. | | PLEASE SHOW COMPLIANCE WITH: | | | | 3A) 2014 ACCESSIBILITY CODE 226.1 WHERE DINING SURFACES | | ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT | | LEAST 5 PERCENT OF THE SEATING SPACES AND STANDING | | SPACES AT THE DINING SURFACES SHALL COMPLY WITH 902. | | | | 3B) 2014 ACCESSIBILITY CODE 226.2 DISPERSION. DINING | | SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED | | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING | | SURFACES. | | | | 3C) 2014 ACCESSIBILITY CODE. 902.3 HEIGHT. THE TOPS OF | | DINING SURFACES AND WORK SURFACES SHALL BE 28 INCHES | | (710 MM) MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE | | THE FINISH FLOOR OR GROUND. | | | | 3D)2014 ACCESSIBILITY CODE 902.4.2 HEIGHT. THE TOPS OF | | TABLES AND COUNTERS SHALL BE 26 INCHES (660 MM) MINIMUM | | AND 30 INCHES (760 MM) MAXIMUM ABOVE THE FINISH FLOOR | | OR GROUND. | | | | 4) THE PLANS SHEET A-1 NOTE 2 INDICATES THE GARAGE | | DOORS ARE TO BE OPEN DURING BUSINESS HOURS FOR | | VENTILATION AND NOTE 3 INDICATES THERE IS TO BE NO | | MECHANICAL WORK. PLEASE PROVIDE HOW COMPLIANCE WITH | | 1204.1 EQUIPMENT AND SYSTEMS FBC-B WILL BE COMPLIED | | WITH. | | 2014 FBC-B 1204.1 EQUIPMENT AND SYSTEMS. INTERIOR | | SPACES INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED | | WITH ACTIVE OR PASSIVE SPACE-HEATING SYSTEMS CAPABLE OF | | MAINTAINING AN INDOOR TEMPERATURE OF NOT LESS THAN 68?F | | (20?C) AT A POINT 3 FEET (914 MM) ABOVE THE FLOOR ON | | THE DESIGN HEATING DAY. | | | | 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | DEPARTMENT | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2017-02-28 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-28 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-28 |
Time |
08:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-02-08 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-08 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-08 |
Time |
11:18 |
Sent To |
|
|
Notes |
2017-02-08 11:22:18 | INITIAL COMMENTS ADDRESSED ELECTRICAL. | | | | PLEASE ADDRESS PENDING MECHANICAL COMMENTS FOR AN | | ELECTRICAL APPROVAL. FBC 107.3.5 | | | | V. PEREZ | | *6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-12-01 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-12-01 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-12-01 |
Time |
16:07 |
Sent To |
|
|
Notes |
2016-12-01 17:49:33 | JOB PERMIT NUMBER: 16110835 | | JOB ADDRESS: 1142 OKEECHOBEE RD | | WEST PALM BEACH FLORIDA | | DATE: DECEMBER 1, 2016 | | ELECTRICAL PLAN REVIEW COMMENTS | | | | THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC | | 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | AMENDMENTS. SEE BELOW A LIST OF ITEMS NOTED. | | | | 1] SHOW NEW WIRE-WAY SIZE IN ACCORDANCE WITH NEC 376 & | | 378. SHOW WIRE SIZE FROM METER TO WIRE-WAY. FBC 107 | | | | 2] AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED | | WITHIN 18'' OF THE TOP OF A SHOW WINDOW FOR EVERY 12' | | OR MAJOR PORTION THEREOF AREA MEASURED HORIZONTALLY. | | NEC 210.62 (IF EXISTING PLEASE INDICATE ON PLANS). | | | | 3] EACH COMMERCIAL BUILDING AND COMMERCIAL OCCUPANCY | | ACCESSIBLE TO PEDESTRIANS SHALL BE PROVIDED WITH AT | | LEAST ONE 20 AMP DEDICATED OUTLET IN AN ACCESSIBLE | | LOCATION AT EACH ENTRANCE TO EACH TENANT SPACE FOR SIGN | | OR OUTLINE LIGHTING. SERVICE HALLWAYS OR CORRIDORS | | SHALL NOT BE CONSIDERED ACCESSIBLE TO PEDESTRIANS. NEC | | 600.5 (IF EXISTING PLEASE INDICATE ON PLANS). | | | | 4] EMERGENCY/EXIT LIGHTING SHALL BE FED BY LIGHTING | | CIRCUIT OF SAME LOCAL AREA. NEC 700.12(F)(4) A NOTE | | WILL SUFFICE. | | | | 5] OCCUPANCY SENSORS SHALL BE INSTALLED IN ALL | | CLASSROOMS, CONFERENCE/MEETING ROOMS, EMPLOYEE LUNCH | | AND BREAK ROOMS, PRIVATE OFFICES, RESTROOMS, STORAGE | | ROOMS AND JANITORIAL CLOSETS, AND OTHER SPACES 300 | | SQUARE FEET (28 M2) OR LESS ENCLOSED BY | | FLOOR-TO-CEILING HEIGHT PARTITIONS. THESE AUTOMATIC | | CONTROL DEVICES SHALL BE INSTALLED TO AUTOMATICALLY | | TURN OFF LIGHTS WITHIN 30 MINUTES OF ALL OCCUPANTS | | LEAVING THE SPACE, AND SHALL EITHER BE MANUAL ON OR | | SHALL BE CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING | | ON TO NOT MORE THAN 50 PERCENT POWER. FBC-E SECTION | | C405.2.2.2. | | | | 6] ELECTRICAL EQUIPMENT IN OTHER THAN DWELLING UNITS | | LIKELY TO REQUIRE SERVICED WHILE ENERGIZED SHALL BE | | FIELD MARKED (LABEL SHALL WITHSTAND ENVIORMENT | | INVOLVED) TO WARN AGAINST POTENTIAL ARC-FAULT HAZARDS. | | NEC 110.16 A NOTE WILL SUFFICE. | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER | | RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES | | WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER | | QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME | | DIRECTLY. | | | | 1ST REVIEW FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2017-02-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-02-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-02-24 |
Time |
15:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-01-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-01-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-01-20 |
Time |
16:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2016-11-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2016-11-28 |
Time |
08:37 |
Sent To |
|
|
Notes |
2016-11-28 10:03:15 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) THE SUBMITTED PLAN SHEETS DO NOT INDICATE CONSISTANT | | ORDER OR COUNT. | | | | | | PLEASE CORRECT. | | | | | | | | 2) SHEET CVR & A 2 - THE OCCUPANCY LOAD CALCULATION | | INDICATES FOR BUSINESS @ 30/SQ FT PER THE FBC; HOWEVER, | | THE FFPC REQUIREMENT IS @ 15/SQ FT, LESS CONCENTRATED | | USE. THIS WOULD AFFECT YOUR PROPOSED OCCUPANCY LOAD. | | | | ADDITIONALLY, THIS WOULD ALSO AFFECT YOUR KITCHEN AREA | | LOAD. | | | | NFPA 101, CHAPTER 7, MEANS OF EGRESS | | | | 7.3.1.3 OCCUPANT LOAD INCREASES. | | 7.3.1.3.1 THE OCCUPANT LOAD IN ANY BUILDING OR PORTION | | THEREOF SHALL BE PERMITTED TO BE INCREASED FROM THE | | OCCUPANT LOAD ESTABLISHED FOR THE GIVEN USE IN | | ACCORDANCE WITH 7.3.1.2 WHERE ALL OTHER REQUIREMENTS OF | | THIS CODE ARE ALSO MET, BASED ON SUCH INCREASED | | OCCUPANT LOAD. | | | | ASSEMBLY -LESS CONCENTRATED USE 15/SQ FT/PERSON | | | | KITCHEN - 100/SQ FT/PERSON | | | | PLEASE CORRECT OR MODIFY YOUR OCCUPANCY LOAD | | CALCULATIONS FOR EACH AREA TO MORE ACCURATELY REFLECT | | PER THE FFPC. | | | | | | | | | | 3) SHEET A 2 - THE PLAN INDICATES TWO EXITS; HOWEVER, | | THEY DO NOT MEET THE REQUIREMENTS OF NFPA 101, CHAPTER | | 12, NEW ASSEMBLY OCCUPANCIES & CHAPTER 7, MEAN OF | | EGRESS. | | | | CHAPTER 12 | | | | 12.2.4* NUMBER OF MEANS OF EGRESS. | | 12.2.4.1 THE NUMBER OF MEANS OF EGRESS SHALL BE IN | | ACCORDANCE WITH SECTION 7.4, OTHER THAN EXITS FOR | | FENCED OUTDOOR ASSEMBLY OCCUPANCIES IN ACCORDANCE WITH | | 12.2.4.4. | | | | 12.2.5 ARRANGEMENT OF MEANS OF EGRESS. | | 12.2.5.1 GENERAL. | | 12.2.5.1.1 MEANS OF EGRESS SHALL BE ARRANGED IN | | ACCORDANCE WITH SECTION 7.5. | | | | CHAPTER 7 | | | | 7.4* NUMBER OF MEANS OF EGRESS. | | 7.4.1 GENERAL. | | 7.4.1.1 THE NUMBER OF MEANS OF EGRESS FROM ANY BALCONY, | | MEZZANINE, STORY, OR PORTION THEREOF SHALL BE NOT LESS | | THAN TWO, EXCEPT UNDER ONE OF THE FOLLOWING CONDITIONS: | | (1) A SINGLE MEANS OF EGRESS SHALL BE PERMITTED WHERE | | PERMITTED IN CHAPTERS 11 THROUGH 43. | | (2) A SINGLE MEANS OF EGRESS SHALL BE PERMITTED FOR A | | MEZZANINE OR BALCONY WHERE THE COMMON PATH OF TRAVEL | | LIMITATIONS OF CHAPTERS 11 THROUGH 43 ARE MET. | | | | TWO EXITS ARE INDICATED; HOWEVER, THEY DO NOT MEET THE | | SEPARATION REQUIRMENT: | | | | 7.5 ARRANGEMENT OF MEANS OF EGRESS. | | 7.5.1 GENERAL. | | 7.5.1.1 EXITS SHALL BE LOCATED, AND EXIT ACCESS SHALL | | BE ARRANGED, SO THAT EXITS ARE READILY ACCESSIBLE AT | | ALL TIMES. | | | | 7.5.1.3.1 WHERE MORE THAN ONE EXIT, EXIT ACCESS, OR | | EXIT DISCHARGE IS REQUIRED FROM A BUILDING OR PORTION | | THEREOF, SUCH EXITS, EXIT ACCESSES, OR EXIT DISCHARGES | | SHALL BE REMOTELY LOCATED FROM EACH OTHER AND BE | | ARRANGED TO MINIMIZE THE POSSIBILITY THAT MORE THAN ONE | | HAS THE POTENTIAL TO BE BLOCKED BY ANY ONE FIRE OR | | OTHER EMERGENCY CONDITION. | | | | 7.5.1.3.2* WHERE TWO EXITS, EXIT ACCESSES, OR EXIT | | DISCHARGES ARE REQUIRED, THEY SHALL BE LOCATED AT A | | DISTANCE FROM ONE ANOTHER NOT LESS THAN ONE-HALF THE | | LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE | | BUILDING OR AREA TO BE SERVED, MEASURED IN A STRAIGHT | | LINE BETWEEN THE NEAREST EDGE OF THE EXITS, EXIT | | ACCESSES, OR EXIT DISCHARGES, UNLESS OTHERWISE PROVIDED | | IN 7.5.1.3.3 THROUGH 7.5.1.3.5. | | | | | | PLEASE PROVIDE FOR THE REQUIRED EXIT SEPARATION. | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-03-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-13 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-03-10 |
Time |
17:25 |
Sent To |
|
|
Notes |
2017-03-10 17:26:00 | CCOLE'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-03-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-08 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-22 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-02-08 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-08 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-08 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-12-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-12-12 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-17 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2017-01-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2017-01-25 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2017-01-25 |
Time |
09:06 |
Sent To |
|
|
Notes |
2017-01-25 09:41:42 | PALM BEACH COUNTY IMPACT FEES: | | MU2017-360 | | 1502 SQ. FT. | | FEES: $8255.81 | | JW |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-12-05 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-12-05 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2016-12-05 |
Time |
09:05 |
Sent To |
|
|
Notes |
2016-12-05 11:34:35 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2017-03-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-13 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-03-13 |
Time |
12:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2017-03-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-03-08 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-03-08 |
Time |
17:34 |
Sent To |
|
|
Notes |
2017-03-08 17:39:25 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16110835 | | 3/8/17 | | | | 1) THE ENGINEER OF RECORD- DONALD HARDY AUSTIN JR.- | | SHALL PLACE HIS SIGNATURE AND SEAL ON THE M-1 PLAN | | SHEET IN ACCORDANCE WITH SECTION 61G15-23.002 FLORIDA | | ADMINISTRATIVE CODE. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-01-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-01-25 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-01-25 |
Time |
17:12 |
Sent To |
|
|
Notes |
2017-01-25 17:26:04 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16110835 | | 1/25/17 | | | | SOME OF THE COMMENTS FROM THE 1ST REVIEW STILL EXIST OR | | HAVCE NOT BEEN ADDRESSED ENTIRELY. PLEASE NOTE THAT A | | 4X PLAN REVIEW FEE MAY APPLY IF THE PLAN IS DISAPPROVED | | A THRID TIME FOR THE SAME CODE VIOLATIONS- SECTION | | 553.80 FLORIDA STATUTES. | | | | 1) THE PROJECT IS DEFINED AS A CHANGE OF OCCUPANCY IN | | ACCORDANCE WITH SECTION 202 AND 506.1 FBC-14 EXISTING | | BUILDING CODES,. PLEASE CORRECT THE LEVEL 2 ALTERATION | | NOTE ON SHEET CVR, AND REFER TO CHAPETER 10 FOR ALL | | COMPLIANCE INFORMATION. | | | | 2) REFER TO SECTION C101.4.4 FBC-14 ENERGY CONSERVATION | | AND SUBMIT DOCUMENTATION OF COMPLIANCE. SEE SECTION | | C401.2 FOR COMPLIANCE PATH INFORMATION. | | | | 3) COMMENT #2 FROM THE 1ST REVIEW STILL EXISTS: EXHAUST | | VENTILATION IS REQUIRED FOR THE TOILET ROOM AND THE | | KITCHEN- SEE TABLE 403.3 AND SHOW COMPLIANCE. | | | | 4) COMMENT #3 FROM THE 1ST REVIEW STILL EXISTS: THE | | PLAN IS INDICATING NATURAL VENTILATION. PLEASE SEE | | SECTION 402.2 AND PROVIDE A CALCULATION. | | | | 5) THE REVISED PLAN INDICATES AND EXISTING 5TON HEAT | | PUMP. PLEASE SHOW THE DUCT LAYOUT PLAN INDICATING ALL | | ALTERATIONS TO THE EXISTING SYSTEM. AS PREVIOUSLY NOTED | | IN 1ST REVIEW COMMENT #5, MINIMUM HEAT IS REQUIRED FOR | | THE BAR AREA. | | | | 6) PROVIDE AN EQUIPMENT SCHEDULE FOR ALL BREWERY TANKS | | AND EQUIPMENT, AND SUBMIT MANUFACTURER;S SPECIFCATIONS | | FOR ALL. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-12-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-02 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-02 |
Time |
17:13 |
Sent To |
|
|
Notes |
2016-12-02 17:30:13 | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | PERMIT #16110835 | | 12/2/16 | | | | 1) REFER THE FBC-14 EXISTING BUILDING CODE AND PROVIDE | | THE CLASSIFICATION OF WORK ON THE PLAN AS DETERMINED IN | | ACCORDANCE WITH CHAPTER 5 | | | | 2) EXHAUST VENTILATION IS REQUIRED FOR THE TOILET ROOM | | AND THE KITCHEN- SEE TABLE 403.3 AND SHOW COMPLIANCE. | | | | 3) ADVISORY: SEPARATE PERMITS ARE REQUIRED FOR KITCHEN | | EXHAUST HOODS, FIRE SUPRESSION, AND WALK-IN COOLERS AND | | FREEZERS. | | | | 4) THE PLAN IS INDICATING NATURAL VENTILATION. PLEASE | | SEE SECTION 402.2 AND PROVIDE A CALCULATION. | | | | 5) REFER TO SECTION 309.1 TEMPERATURE CONTROL- AN | | ACTIVE OR PASSIVE SPACE HEATING SYSTEM CAPABLE OF | | MAINTAINING A MINIMUM INDOOR TEMPERATURE OF 68 DEGREES | | IS REQUIRED. PLEASE NOTE THAT NEW CONDITIONING OF THE | | SPACE WILL REQUIRE AC AND ENERGY CALCULATIONS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-03-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-06 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-06 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-02-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-02-03 |
Time |
06:30 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-02-03 |
Time |
05:39 |
Sent To |
|
|
Notes |
2017-02-03 06:30:16 | 1) SHT. CVR - THERE IS A NOTE ON THE PLAN THAT READS " | | SEPARATE FACILITIES SHALL NOT BE REQUIRED IN BUSINESS | | AND MERCANTILE OCCUPANCIES WITH A TOTAL FLOOR AREA OF | | 3000 SF OR LESS." WHAT CODE ARE YOU CITING THIS FROM | | AND WHAT IS THE SPECIFIC CODE SECTION? I COULD NOT FIND | | ANY SUCH EXCEPTION IN THE 2014 FBC. CLARIFY. | | 2) SEPARATE SANITARY FACILITIES ARE REQUIRED FOR MALES | | AND FEMALES IN THE NUMBER SPECIFIED IN 2014 | | FBC-PLUMBING TABLE 403.1. | | 3) SUBMIT THE MANUFACTURER'S SPECIFICATION SHEETS FOR | | THE BREWERY VESSELS. WPB AMEND. TO FBC SEC. 107.2.1. | | 4) THE MINIMUM WIDTH OF THE HANDICAPPED ACCESSIBLE | | TOILET ROOM SHALL BE 85 INCHES TO COMPLY WITH THE | | REQUIRED CLEAR FLOOR SPACES FOR THE PLUMBING FIXTURES | | PER 2014 FBC-ACCESS. SECS.305, 604.3, 2014 FBC-PLUMBING | | SEC. 405.3.1. | | 5) SHT. A-3 - DETAIL #3 SHOWS THE TOP OF THE LAVATORY | | AT 40 INCHES ABOVE THE FINISH FLOOR AND ALSO 34 INCHES | | ABOVE THE FINISH FLOOR. THE MAXIMUM HEIGHT SHALL BE 34 | | INCHES TO THE TOP OF THE LAVATORY. | | 6) SHT. P-2 - THE 2 INCH AAV/VENT FOR THE MOP SINK AND | | FLOOR SINK SHALL BE LOCATED BETWEEN THE TWO FIXTURES. | | 2014 FBC-PLUMBING SECS. 901.2, 901.2.1. | | 7) SHTS. EQ-1, E-2, & P-2 SHOW THE DOOR TO THE | | ACCESSIBLE TOILET SWINGING INTO THE CLEAR FLOOR SPACE | | FOR THE LAVATORY. COMPLY WITH 2014 FBC-ACCESS. SEC. | | 603.2.3. | | 8) THE TRENCH DRAIN TRAP SHALL BE PROVIDED WITH A TRAP | | PRIMER. 2014 FBC-PLUMBING SEC.1002.4. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-12-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-12-12 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-12-12 |
Time |
13:20 |
Sent To |
|
|
Notes |
2016-12-12 13:20:04 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | | | 1. THE PLANS INDICATE A BUSINESS OCCUPANCY IF THEY ARE | | SERVING BEER TO THE PUBLIC ITS GOING TO BE A A2 | | OCCUPANCY IF THEY ARE JUST BREWING BEER IT SHOULD BE AN | | F2. PER FBC 303.3-303.6 | | THE OCCUPANT LOAD SHOULD BE CALCULATED USING 15 NET FOR | | SEATING AREA AND 100 GROSS FOR BEER BREWING AREA PER | | FBC TABLE 1004.1.2 | | | | 2. THE COVER SHEET IN THE PLUMBING FIXTURE CALCULATIONS | | IT INDICATES 1 WC 1 LAV FOR MALE AND 1 WC 1 LAV FOR | | FEMALE THE PLAN ONLY SHOWS ONE FOR BOTH TWO ARE | | REQUIRED. PER FBC PL | | 403.2 SEPARATE FACILITIES. | | WHERE PLUMBING FIXTURES ARE REQUIRED, SEPARATE | | FACILITIES SHALL BE PROVIDED FOR EACH SEX. | | | | 3. SHT. P-2 THE TRENCH DRAIN IS NOT VENTED. FBC PL | | 901.2.1 | | | | 4. IF THIS IS NOT AN A2 A DRINKING FOUNTAIN IS | | REQUIRED. PER FBC PL TABLE 403.1 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2017-03-03 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-03-03 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-03-03 |
Time |
10:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-01-23 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-01-23 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-01-23 |
Time |
14:50 |
Sent To |
|
|
Notes |
2017-01-23 16:35:11 | 1/23/17- PASSED | | | | PARKING PLAN MUST MEET PARKING REQUIREMENTS | | MUST APPLY FOR A LIQUOR LICENSE | | MUST APPLY FOR A BUSINESS TAX | | | | PLEASE CONTACT | | NATHAN WIRA | | [email protected] | | (561)822-1442 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-11-30 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2016-11-30 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2016-11-30 |
Time |
13:27 |
Sent To |
|
|
Notes |
2016-11-30 16:08:07 | 11/30/16- PASSED | | | | MUST APPLY FOR A BUSINESS TAX | | MUST APPLY FOR A LIQUOR LICENSE | | MUST SHOW MEET THE PARKING REQUIRMENT | | MUST APPLY FOR A LANDSCAPE PLAN | | | | PLEASE CONTACT | | NATHAN WIRA | | [email protected] | | (561)822-1442 | | |
|
|