Plan Review Stops For Permit 16110786 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2018-06-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-06-07 |
Time |
18:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-06-07 |
Time |
11:43 |
Sent To |
I |
|
Notes |
2018-06-07 12:23:26 | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- PROVIDE COMPLETE MANUFACTURER'S SPECS FOR ALL | | FIREPLACES SHOWN ON PLANS. NOTE: DESIGNER OF RECORD TO | | REVIEW/APPROVE PRIOR TO SUBMITTAL. | | 2- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R5 | | SUBMITTED: PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS FOR SELECTED ASSEMBLY W-55 AS REQUIRED BY | | NOTE #8 ON PAGE 2 OF 76. | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A)ENTRY DOOR AS SPECIFIED ON PLANS. | | B) EXTERIOR DOORS: FRENCH DOORS WITH SIDELITES, GARAGE | | SWING DOOR, LAUNDRY ROOM, CABANA BATHROOM AND CABANA | | STORAGE. | | 4- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2018-03-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-03-09 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-03-09 |
Time |
11:29 |
Sent To |
|
|
Notes |
2018-03-09 11:42:05 | RESIDENTIAL (R3) REVISION, THIRD BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION. | | | | 1- ONE SET OF PLANS IS MISSING DRAWINGS A000 AND S2 | | THRU S11. PROVIDE TWO COMPLETE SET OF PLANS. SEC. 107.1 | | CITY AMENDMENTS. | | | | | | REMAINDER: | | BUILDING REVIEW WAS APPROVED ON 05/13/16 WITH PROVISO. | | PROVISO ITEMS NEED TO BE SUBMITTED BEFORE INSPECTIONS | | TO AVOID DELAYS/CONFLICTS. SEE COPY OF COMMENTS BELOW: | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- ENERGY CALCULATIONS SUBMITTED: REVISE ROOF FINISH | | MATERIAL INFORMATION ON PAGE 2 TO MATCH PLANS. | | 2- PROVIDE COMPLETE MANUFACTURER'S SPECS FOR ALL | | FIREPLACES SHOWN ON PLANS. NOTE: DESIGNER OF RECORD TO | | REVIEW/APPROVE PRIOR TO SUBMITTAL. | | 3- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R5 | | SUBMITTED: PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS FOR SELECTED ASSEMBLY W-55 AS REQUIRED BY | | NOTE #8 ON PAGE 2 OF 76. | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A)ENTRY DOOR AS SPECIFIED ON PLANS. DRAWING NO | | "LAG-TEN" SUBMITTED DON'T CORRESPOND TO FLORIDA PRODUCT | | APPROVAL COVER PAGE FL15911-R1 SUBMITTED. | | B) EXTERIOR DOORS: FRENCH DOORS WITH SIDELITES, GARAGE | | SWING DOOR, LAUNDRY ROOM, CABANA BATHROOM AND CABANA | | STORAGE. | | 6- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2018-02-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-06 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-06 |
Time |
09:32 |
Sent To |
P |
|
Notes |
2018-02-06 09:40:35 | | | 02/06/18 | | | | NOTE: MISSING ONE SET OF DRAWINGS. ONE SET OF PLANS WAS | | SIGNED OUT ON MARCH 01/2017 BUT IT WAS NEVER RETURNED. | | NEED TO HAVE TWO COMPLETE SETS WITH THE REVISED | | INSERTED AND OLD PLANS REMOVED. REVIEW WILL BE RESUMED | | WHEN SECOND SET OF PLANS IS SUBMITTED. JG. | | | | | | PRELIMINARY REVIEW OF REVISED PLAN FROM ARCHITECT DAVID | | LAWRENCE. | | | | 1- IT LOOKS LIKE THE REVISED PLAN COMPLIES WITH THE | | WINDOW FALL PROTECTION AND SAFETY GLASS REQUIREMENTS. | | NEED TO REVISE WINDOW SCHEDULE ACCORDINGLY. | | | | | | | | RESIDENTIAL (R3) REVISION, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION. | | | | 1- REVISED UPPER LIVING ROOM WINDOWS AND REVISED | | WINDOWS FOR BEDROOM #210 LOCATED ON THE NORTH EAST | | CORNER NEED TO COMPLY WITH THE WINDOW FALL PROTECTION | | REQUIREMENTS OF SEC. R312.2 FBC-RESIDENTIAL, 5TH | | EDITION (2014). PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING COMPLIANCE WITH THE FALL | | PROTECTION. | | NOTE: THIS ALSO APPLIES TO THE MASTER BEDROOM WINDOWS | | AND ANY OTHER WINDOW WHERE THE BOTTOM OF THE WINDOW | | SILL IS LESS THAN 24" ABOVE FINISHED FLOOR AND MORE | | THAN 72" ABOVE FINISHED GRADE OR SURFACE BELOW. | | RESPONSE: SHEET A101 WAS REVISED SHOWING GUARDRAILS FOR | | ALL FOUR FIXED WINDOWS IN THE HALL BY THE MORNING | | BREAKFAST AREA, HALL 205 AND BEDROOM 210. THE GUARDRAIL | | WILL TAKE CARE OF THE SAFETY GLASS REQUIREMENTS. THESE | | FOUR DOORS ARE FIXED. THEY DON'T NEED TO COMPLY WITH | | THE WINDOW FALL PROTECTION. THE WINDOW FALL PROTECTION | | APPLIES TO THE WINDOWS ON BEDROOM 210 THAT ARE FACING | | EAST, THE WINDOWS ON MASTER TERRACE 214 AND THE WINDOWS | | ON MASTER BEDROOM THAT ARE FACING EAST. REVISE PLANS | | SHOWING COMPLIANCE WITH THE FALL PROTECTION FOR THOSE | | WINDOWS FOR ALL THE WINDOWS WHERE THE BOTTOM OF THE | | WINDOW SILL IS LESS THAN 24" ABOVE FINISHED FLOOR AND | | MORE THAN 72" ABOVE FINISHED GRADE OR SURFACE BELOW. | | | | 2- SIX DRAWINGS WERE REVISED AND RE-SUBMITTED. OWES | | $309.00 FOR REVISION RE-SUBMITTAL FEES. | | | | | | REMAINDER: (NOT ADDRESSED AS OF 02/06/17) | | BUILDING REVIEW WAS APPROVED ON 05/13/16 WITH PROVISO. | | PROVISO ITEMS NEED TO BE SUBMITTED BEFORE INSPECTIONS | | TO AVOID DELAYS/CONFLICTS. SEE COPY OF COMMENTS BELOW: | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- ENERGY CALCULATIONS SUBMITTED: REVISE ROOF FINISH | | MATERIAL INFORMATION ON PAGE 2 TO MATCH PLANS. | | 2- PROVIDE COMPLETE MANUFACTURER'S SPECS FOR ALL | | FIREPLACES SHOWN ON PLANS. NOTE: DESIGNER OF RECORD TO | | REVIEW/APPROVE PRIOR TO SUBMITTAL. | | 3- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R5 | | SUBMITTED: PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS FOR SELECTED ASSEMBLY W-55 AS REQUIRED BY | | NOTE #8 ON PAGE 2 OF 76. | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A)ENTRY DOOR AS SPECIFIED ON PLANS. DRAWING NO | | "LAG-TEN" SUBMITTED DON'T CORRESPOND TO FLORIDA PRODUCT | | APPROVAL COVER PAGE FL15911-R1 SUBMITTED. | | B) EXTERIOR DOORS: FRENCH DOORS WITH SIDELITES, GARAGE | | SWING DOOR, LAUNDRY ROOM, CABANA BATHROOM AND CABANA | | STORAGE. | | 6- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-03-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-01-29 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-29 |
Time |
10:29 |
Sent To |
|
|
Notes |
2018-01-29 10:29:40 | PRELIMINARY REVIEW OF REVISED PLAN FROM ARCHITECT DAVID | | LAWRENCE. | | | | 1- IT LOOKS LIKE THE REVISED PLAN COMPLIES WITH THE | | WINDOW FALL PROTECTION AND SAFETY GLASS REQUIREMENTS. | | NEED TO REVISE WINDOW SCHEDULE ACCORDINGLY. | | | | | | | | RESIDENTIAL (R3) REVISION, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION. | | | | 1- REVISED UPPER LIVING ROOM WINDOWS AND REVISED | | WINDOWS FOR BEDROOM #210 LOCATED ON THE NORTH EAST | | CORNER NEED TO COMPLY WITH THE WINDOW FALL PROTECTION | | REQUIREMENTS OF SEC. R312.2 FBC-RESIDENTIAL, 5TH | | EDITION (2014). PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING COMPLIANCE WITH THE FALL | | PROTECTION. | | NOTE: THIS ALSO APPLIES TO THE MASTER BEDROOM WINDOWS | | AND ANY OTHER WINDOW WHERE THE BOTTOM OF THE WINDOW | | SILL IS LESS THAN 24" ABOVE FINISHED FLOOR AND MORE | | THAN 72" ABOVE FINISHED GRADE OR SURFACE BELOW. | | RESPONSE: SHEET A101 WAS REVISED SHOWING GUARDRAILS FOR | | ALL FOUR FIXED WINDOWS IN THE HALL BY THE MORNING | | BREAKFAST AREA, HALL 205 AND BEDROOM 210. THE GUARDRAIL | | WILL TAKE CARE OF THE SAFETY GLASS REQUIREMENTS. THESE | | FOUR DOORS ARE FIXED. THEY DON'T NEED TO COMPLY WITH | | THE WINDOW FALL PROTECTION. THE WINDOW FALL PROTECTION | | APPLIES TO THE WINDOWS ON BEDROOM 210 THAT ARE FACING | | EAST, THE WINDOWS ON MASTER TERRACE 214 AND THE WINDOWS | | ON MASTER BEDROOM THAT ARE FACING EAST. REVISE PLANS | | SHOWING COMPLIANCE WITH THE FALL PROTECTION FOR THOSE | | WINDOWS FOR ALL THE WINDOWS WHERE THE BOTTOM OF THE | | WINDOW SILL IS LESS THAN 24" ABOVE FINISHED FLOOR AND | | MORE THAN 72" ABOVE FINISHED GRADE OR SURFACE BELOW. | | | | 2- SIX DRAWINGS WERE REVISED AND RE-SUBMITTED. OWES | | $309.00 FOR REVISION RE-SUBMITTAL FEES. | | | | | | REMAINDER: (NOT ADDRESSED AS OF 02/06/17) | | BUILDING REVIEW WAS APPROVED ON 05/13/16 WITH PROVISO. | | PROVISO ITEMS NEED TO BE SUBMITTED BEFORE INSPECTIONS | | TO AVOID DELAYS/CONFLICTS. SEE COPY OF COMMENTS BELOW: | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- ENERGY CALCULATIONS SUBMITTED: REVISE ROOF FINISH | | MATERIAL INFORMATION ON PAGE 2 TO MATCH PLANS. | | 2- PROVIDE COMPLETE MANUFACTURER'S SPECS FOR ALL | | FIREPLACES SHOWN ON PLANS. NOTE: DESIGNER OF RECORD TO | | REVIEW/APPROVE PRIOR TO SUBMITTAL. | | 3- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R5 | | SUBMITTED: PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS FOR SELECTED ASSEMBLY W-55 AS REQUIRED BY | | NOTE #8 ON PAGE 2 OF 76. | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A)ENTRY DOOR AS SPECIFIED ON PLANS. DRAWING NO | | "LAG-TEN" SUBMITTED DON'T CORRESPOND TO FLORIDA PRODUCT | | APPROVAL COVER PAGE FL15911-R1 SUBMITTED. | | B) EXTERIOR DOORS: FRENCH DOORS WITH SIDELITES, GARAGE | | SWING DOOR, LAUNDRY ROOM, CABANA BATHROOM AND CABANA | | STORAGE. | | 6- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-02-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-02-06 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-02-06 |
Time |
12:46 |
Sent To |
|
|
Notes |
2017-02-06 12:48:22 | RESIDENTIAL (R3) REVISION, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION. | | | | 1- REVISED UPPER LIVING ROOM WINDOWS AND REVISED | | WINDOWS FOR BEDROOM #210 LOCATED ON THE NORTH EAST | | CORNER NEED TO COMPLY WITH THE WINDOW FALL PROTECTION | | REQUIREMENTS OF SEC. R312.2 FBC-RESIDENTIAL, 5TH | | EDITION (2014). PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING COMPLIANCE WITH THE FALL | | PROTECTION. | | NOTE: THIS ALSO APPLIES TO THE MASTER BEDROOM WINDOWS | | AND ANY OTHER WINDOW WHERE THE BOTTOM OF THE WINDOW | | SILL IS LESS THAN 24" ABOVE FINISHED FLOOR AND MORE | | THAN 72" ABOVE FINISHED GRADE OR SURFACE BELOW. | | RESPONSE: SHEET A101 WAS REVISED SHOWING GUARDRAILS FOR | | ALL FOUR FIXED WINDOWS IN THE HALL BY THE MORNING | | BREAKFAST AREA, HALL 205 AND BEDROOM 210. THE GUARDRAIL | | WILL TAKE CARE OF THE SAFETY GLASS REQUIREMENTS. THESE | | FOUR DOORS ARE FIXED. THEY DON'T NEED TO COMPLY WITH | | THE WINDOW FALL PROTECTION. THE WINDOW FALL PROTECTION | | APPLIES TO THE WINDOWS ON BEDROOM 210 THAT ARE FACING | | EAST, THE WINDOWS ON MASTER TERRACE 214 AND THE WINDOWS | | ON MASTER BEDROOM THAT ARE FACING EAST. REVISE PLANS | | SHOWING COMPLIANCE WITH THE FALL PROTECTION FOR THOSE | | WINDOWS FOR ALL THE WINDOWS WHERE THE BOTTOM OF THE | | WINDOW SILL IS LESS THAN 24" ABOVE FINISHED FLOOR AND | | MORE THAN 72" ABOVE FINISHED GRADE OR SURFACE BELOW. | | | | 2- SIX DRAWINGS WERE REVISED AND RE-SUBMITTED. OWES | | $309.00 FOR REVISION RE-SUBMITTAL FEES. | | | | | | REMAINDER: (NOT ADDRESSED AS OF 02/06/17) | | BUILDING REVIEW WAS APPROVED ON 05/13/16 WITH PROVISO. | | PROVISO ITEMS NEED TO BE SUBMITTED BEFORE INSPECTIONS | | TO AVOID DELAYS/CONFLICTS. SEE COPY OF COMMENTS BELOW: | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- ENERGY CALCULATIONS SUBMITTED: REVISE ROOF FINISH | | MATERIAL INFORMATION ON PAGE 2 TO MATCH PLANS. | | 2- PROVIDE COMPLETE MANUFACTURER'S SPECS FOR ALL | | FIREPLACES SHOWN ON PLANS. NOTE: DESIGNER OF RECORD TO | | REVIEW/APPROVE PRIOR TO SUBMITTAL. | | 3- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R5 | | SUBMITTED: PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS FOR SELECTED ASSEMBLY W-55 AS REQUIRED BY | | NOTE #8 ON PAGE 2 OF 76. | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A)ENTRY DOOR AS SPECIFIED ON PLANS. DRAWING NO | | "LAG-TEN" SUBMITTED DON'T CORRESPOND TO FLORIDA PRODUCT | | APPROVAL COVER PAGE FL15911-R1 SUBMITTED. | | B) EXTERIOR DOORS: FRENCH DOORS WITH SIDELITES, GARAGE | | SWING DOOR, LAUNDRY ROOM, CABANA BATHROOM AND CABANA | | STORAGE. | | 6- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-12-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-12-02 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-12-02 |
Time |
07:51 |
Sent To |
|
|
Notes |
2016-12-01 16:01:45 | RESIDENTIAL (R3) REVISION, BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION. | | | | 1- AREA CALCULATIONS SHOWN ON THE COVER SHEET DON'T | | MATCH AREA CALCULATIONS SHOWN ON SHEET A000. REVISE AS | | REQUIRED TO MATCH. SEC. 1074.2.1 CITY AMENDMENTS. | | | | 2- REVISED UPPER LIVING ROOM WINDOWS AND REVISED | | WINDOWS FOR BEDROOM #210 LOCATED ON THE NORTH EAST | | CORNER NEED TO COMPLY WITH THE WINDOW FALL PROTECTION | | REQUIREMENTS OF SEC. R312.2 FBC-RESIDENTIAL, 5TH | | EDITION (2014). PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING COMPLIANCE WITH THE FALL | | PROTECTION. | | NOTE: THIS ALSO APPLIES TO THE MASTER BEDROOM | | WINDOWSAND ANY OTHER WINDOW WHERE THE BOTTOM OF THE | | WINDOW SILL IS LESS THAN 24" ABOVE FINISHED FLOOR AND | | MORE THAN 72" ABOVE FINISHED GRADE OR SURFACE BELOW. | | | | 3- NEW DESIGNER OF RECORD TO REVIEW AND APPROVE ALL | | PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. | | | | | | REMAINDER: | | BUILDING REVIEW WAS APPROVED ON 05/13/16 WITH PROVISO. | | PROVISO ITEMS NEED TO BE SUBMITTED BEFORE INSPECTIONS | | TO AVOID DELAYS/CONFLICTS. SEE COPY OF COMMENTS BELOW: | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- ENERGY CALCULATIONS SUBMITTED: REVISE ROOF FINISH | | MATERIAL INFORMATION ON PAGE 2 TO MATCH PLANS. | | 2- PROVIDE COMPLETE MANUFACTURER'S SPECS FOR ALL | | FIREPLACES SHOWN ON PLANS. NOTE: DESIGNER OF RECORD TO | | REVIEW/APPROVE PRIOR TO SUBMITTAL. | | 3- FLAT ROOF FLORIDA PRODUCT APPROVAL FL5680-R5 | | SUBMITTED: PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS FOR SELECTED ASSEMBLY W-55 AS REQUIRED BY | | NOTE #8 ON PAGE 2 OF 76. | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.002(33) FOR: | | A)ENTRY DOOR AS SPECIFIED ON PLANS. DRAWING NO | | "LAG-TEN" SUBMITTED DON'T CORRESPOND TO FLORIDA PRODUCT | | APPROVAL COVER PAGE FL15911-R1 SUBMITTED. | | B) EXTERIOR DOORS: FRENCH DOORS WITH SIDELITES, GARAGE | | SWING DOOR, LAUNDRY ROOM, CABANA BATHROOM AND CABANA | | STORAGE. | | 6- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | APPROVALS. | | | | REMAINDER: SPECIAL INSPECTOR WILL BE REQUIRED FOR THE | | INSPECTION OF THE SECOND FLOOR SLAB. SEC. 110.3.9 CITY | | AMENDMENTS. PLEASE CONTACT KEN CONRAD (CHIEF BUILDING | | INSPECTOR. (561)805-6666 OR [email protected]) ) FOR | | DETAILS OF QUALIFIED INSPECTORS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-02-07 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-02-07 |
Time |
13:20 |
Sent To |
B |
|
Notes |
2018-02-07 13:20:46 | THERE ARE 2 COPIES OF THE ELECTRICAL PLANS, SO I HAVE | | APPROVED AND SIGNED BOTH COPIES. | 2018-02-06 10:22:37 | 02/06/18 | | | | NOTE: MISSING ONE SET OF DRAWINGS. ONE SET OF PLANS WAS | | SIGNED OUT ON MARCH 01/2017 BUT IT WAS NEVER RETURNED. | | NEED TO HAVE TWO COMPLETE SETS WITH THE REVISED | | INSERTED AND OLD PLANS REMOVED. JG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-02-15 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-15 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-15 |
Time |
13:48 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-12-20 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-12-20 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2016-12-15 |
Time |
10:40 |
Sent To |
|
|
Notes |
2016-12-20 12:31:45 | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | ELECTRICAL REVIEW COMMENTS. | | | | PROVIDE A SUMMARY LOAD CALCULATION FOR THE SELECTION | | AND SIZING OF THE ELECTRICAL SERVICE AS NOTED WITHIN | | THE NEC. CONTINUOUS LOADS SUCH AS AC SHOULD BE INCLUDED | | AT 100%. NEC 220.4, 220.80 | | | | INTERCONNECTED SMOKE ALARMS ARE REQUIRED BOTH WITHIN | | AND OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS | | APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | ROOM USED FOR SLEEPING. 2014 FBC R314, 315 | | | | THE ELECTRIC SUBPANEL AT THE GUEST HOUSE MAY NOT BE | | LOCATED IN A CLOSET. PANELS SHALL BE PLACED SO AS TO | | REDUCE TO A MINIMUM THE PROBABILITY OF COMMUNICATING | | FIRE TO ADJACENT COMBUSTIBLE MATERIALS. OVERCURRENT | | DEVICES SHALL NOT BE LOCATED IN THE VICINITY OF EASILY | | IGNITABLE MATERIAL. SUFFICIENT ACCESS AND WORKING SPACE | | IS REQUIRED AT THE SUB PANEL. 36"X 30? IN WIDTH IS THE | | MINIMUM REQUIRED FOR SUB PANELS. NEC 408.17, 240.24 | | (D), 110.26 (A) | | | | CEILING ELECTRICAL BOXES SUPPORTING PADDLE FANS MUST BE | | LISTED FOR THAT USE. NEC 422.18; FBC R 3905.9 | | | | HIGH HAT CEILING LIGHTING FIXTURES IN INSULATED SPACES | | NEED TO BE RATED FOR INSULATION CONTACT. NEC 410.116; | | FBC R 4004 | | | | SWIMMING POOL PUMPS AND SPA EQUIPMENT MUST BE GFCI | | PROTECTED. NEC 680.21(C), FBC R E4203.1.3 | | | | PROVIDE SAFE WORKING CLEARANCES FOR ALL OUTSIDE AIR | | CONDITIONING UNIT DISCONNECTS. NEC 110.26, FBC E3405.1 | | | | AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN | | SERVICE GROUND. NEC 250.94; FBC R E3609 | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | 561-805-6754(OFFICE) | | 561-373-3701(CELL) | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
N |
Date |
2018-02-20 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-20 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-20 |
Time |
09:41 |
Sent To |
|
|
Notes |
2018-02-20 09:43:39 | GAS UNDER SEPARATE PERMIT 17080485 | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-07 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-07 |
Time |
12:35 |
Sent To |
|
|
Notes |
2018-02-07 12:37:40 | 3RD REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: 3RD REQUEST | | | | 1. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | 2. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | NEW COMMENT: | | | | 1. TWO SETS OF PLANS ARE REQUIRED. PER WPB AMEND TO FBC | | 107.2 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2017-03-01 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-01 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-02-28 |
Time |
14:25 |
Sent To |
|
|
Notes |
2017-03-01 08:44:26 | 2ND REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: 2ND REQUEST | | | | 1. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | 2. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-12-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-12-12 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-12-12 |
Time |
16:26 |
Sent To |
|
|
Notes |
2016-12-12 16:29:03 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: | | | | 1. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | 2. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-12-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-12-21 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-12-21 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2018-06-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-06-07 |
Time |
18:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-05-30 |
Time |
15:52 |
Sent To |
I |
|
Notes |
2018-05-31 15:52:16 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2018-03-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-03-09 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-08 |
Time |
15:28 |
Sent To |
I |
|
Notes |
2018-02-09 15:28:43 | RESUB OF REVISION ROUTED TO GJOHNSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-06 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-29 |
Time |
13:21 |
Sent To |
I |
|
Notes |
2018-01-31 13:21:20 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-02-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-01-29 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-01-29 |
Time |
10:51 |
Sent To |
|
|
Notes |
2018-01-29 10:52:37 | RECEIVED E-MAIL FROM ARCH. DAVID LAWRENCE. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-03-01 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-01 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-02-01 |
Time |
10:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-12-21 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2016-12-21 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2016-11-16 |
Time |
14:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-03-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-03-09 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-03-09 |
Time |
11:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2016-12-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2016-12-02 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2016-12-02 |
Time |
12:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-02-20 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-20 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-20 |
Time |
09:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-07 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-07 |
Time |
12:38 |
Sent To |
|
|
Notes |
2018-02-07 12:39:12 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. TWO SETS OF PLANS ARE REQUIRED. PER WPB AMEND TO FBC | | 107.2 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-12-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-12-12 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-12-12 |
Time |
16:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-12-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-12-21 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-12-21 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|