Plan Review Stops For Permit 16110543 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-01-11 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-01-11 |
Time |
09:42 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-11-28 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-11-28 |
Time |
09:56 |
Sent To |
E |
|
Notes |
2016-11-28 10:35:04 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | | | 1. ROOFING PERMIT REQUIRED. | | 2. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | 3. PROVIDE DETAIL FOR SPIRAL STAIRS AT NEW DECK. | | 4. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS AT | | WINDOW LOCATION #3. | | 5. PROVIDE DETAIL FOR BALCONY GUARDS. | | 6. PROVIDE ENERGY SUBMITTALS. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW | | MULLION SUBMITTALS. | | | | SECTION R312 GUARDS AND WINDOW FALL PROTECTION | | GUARDS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS | | R312.1.1 THROUGH R312.1.4. | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-11 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2017-01-11 |
Time |
13:13 |
Sent To |
P |
|
Notes |
2017-01-11 14:07:55 | ROUTED TO GJ. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-11-28 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-11-28 |
Time |
11:31 |
Sent To |
P |
|
Notes |
2016-11-28 13:12:48 | JOB PERMIT NUMBER: 16110543 (REVISION) | | JOB ADDRESS: 336 MARLBOROUGH RD | | WEST PALM BEACH FLORIDA | | DATE: NOVEMBER 28, 2016 | | ELECTRICAL PLAN REVIEW COMMENTS | | | | THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC | | 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | AMENDMENTS. SEE BELOW A LIST OF ITEMS NOTED. | | | | 1] EVERY SEPARATE BUILDING OR AN ADDITION TO AN | | EXISTING BUILDING FOR WHICH A PERMIT FOR NEW | | CONSTRUCTION IS ISSUED AND HAVING A FOSSIL-FUEL-BURNING | | HEATER OR APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, | | OR OTHER FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON | | MONOXIDE AS BYPRODUCT OF COMBUSTION SHALL HAVE AN | | OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN 10 | | FEET (3048 MM) OF EACH ROOM USED FOR SLEEPING PURPOSES. | | FBC-R 315.1 | | | | 2] SHOW A SMOKE ALARM IN THE FIRST FLOOR LOWER LEVEL | | STAIRWAY LANDING PER FBC-R 314.3 | | | | 3] BREAKFAST ROOM MISSING A RECEPTACLE IN SHORT WALL | | SPACE SECTION BY THE 1ST FLOOR DOUBLE DOOR PER FBC-R | | SECTION E3902.2.2 (2' WALL SPACE). | | | | 4] PROVIDE RECEPTACLE & LIGHTING OUTLETS IN BEDROOM 1 & | | 2 IN ACCORDANCE WITH FBC-R SECTIONS E3901.2.1 & E3903.2 | | | | 5] PROVIDE AN ELECTRICAL RISER DIAGRAM, INCLUDE | | GROUNDING & CONDUIT DETAIL. FBC-107 | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER | | RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES | | WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER | | QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME | | DIRECTLY. | | | | 1ST REVIEW FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2016-11-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2016-11-21 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2016-11-21 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2017-01-31 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-01-31 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-01-24 |
Time |
16:34 |
Sent To |
|
|
Notes |
2017-01-25 16:34:54 | RESUB OF REVISION ROUTED TO JVALIDO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-11 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-12-19 |
Time |
15:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-12-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-12-14 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-12-14 |
Time |
14:36 |
Sent To |
|
|
Notes |
2016-12-14 14:36:53 | IMPACT FEES ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-29 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-10 |
Time |
12:58 |
Sent To |
|
|
Notes |
2017-01-10 18:49:17 | ROUTED TO CHRIS THROOP 1/10/2017 - JORGE V. | 2016-11-14 12:58:18 | R05 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-12-14 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-12-14 |
Time |
15:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-11-28 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-11-28 |
Time |
10:07 |
Sent To |
|
|
Notes |
2016-11-28 10:20:27 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2017-01-30 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2017-01-30 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-01-10 |
Time |
|
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2017-01-10 |
Time |
18:05 |
Sent To |
|
|
Notes |
2017-01-10 18:40:57 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | (1) PROVIDE MECHANICAL PLANS SHOWING HVAC FOR ENTIRE | | HOME. PROVIDE MAIN DUCT SIZES, BRANCH SIZES, GRILL | | SIZES, CFM QUANTITIES. DIFFERENTIATE EXISTING AND NEW | | DUCT WORK. | | (2) PROVIDE BALANCE RETURN FROM ALL BEDROOMS | | (3) PROVIDE EXHAUST FROM ALL BATHROOMS | | | | FLORIDA ENERGY CODE FBC 2014 | | | | (4) FORMS R405-2014 REQUIRES SIGNATURE AT OWNER /AGENT. | | (5) HEAT LOAD CALCULATIONS MUST HAVE NAME AND SIGNATURE | | OF PREPARED BY. | | (6) PROVIDE AHRI SHEET | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-11-28 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-11-28 |
Time |
11:12 |
Sent To |
|
|
Notes |
2016-11-28 11:18:02 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | FBC- 107.3.5.3 ? PROVIDE A MECHANICAL & EQUIPMENT PLAN | | TO SHOW SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER | | FBC-R M15. | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | R403.6.1 EQUIPMENT SIZING. | | HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN | | ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT | | LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR | | OTHER APPROVED HEATING AND COOLING CALCULATION | | METHODOLOGIES, BASED ON BUILDING LOADS FOR THE | | DIRECTIONAL ORIENTATION OF THE BUILDING. THE | | MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR | | UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH | | THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN | | CONDITIONS DESCRIBED IN SECTION R302.1. THIS CODE DOES | | NOT ALLOW DESIGNER SAFETY FACTORS, PROVISIONS FOR | | FUTURE EXPANSION OR OTHER FACTORS WHICH AFFECT | | EQUIPMENT SIZING. SYSTEM SIZING CALCULATIONS SHALL NOT | | INCLUDE LOADS CREATED BY LOCAL INTERMITTENT MECHANICAL | | VENTILATION SUCH AS STANDARD KITCHEN AND BATHROOM | | EXHAUST SYSTEMS. | | | | R403.6.1.1 COOLING EQUIPMENT CAPACITY. | | COOLING ONLY EQUIPMENT SHALL BE SELECTED SO THAT ITS | | TOTAL CAPACITY IS NOT LESS THAN THE CALCULATED TOTAL | | LOAD, BUT NOT MORE THAN 1.15 TIMES GREATER THAN THE | | TOTAL LOAD CALCULATED ACCORDING TO THE PROCEDURE | | SELECTED IN SECTION 403.6, OR THE CLOSEST AVAILABLE | | SIZE PROVIDED BY THE MANUFACTURER?S PRODUCT LINES. THE | | CORRESPONDING LATENT CAPACITY OF THE EQUIPMENT SHALL | | NOT BE LESS THAN THE CALCULATED LATENT LOAD. | | | | | | STEVEN KENNEDY, CBO | | CHIEF PLANS EXAMINER | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-11 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-11 |
Time |
16:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-29 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-29 |
Time |
07:07 |
Sent To |
|
|
Notes |
2016-11-29 08:37:29 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1.THE WC IN MASTER MATH SHOULD TIE INTO THE BRANCH | | DRAIN FOR MASTER BATHROOM NOT THE STACK. PER WPB AMEND | | TO FBC 107.2.1 | | | | 2.GUEST BATH 2 IT IS REQUIRED TO HAVE A MIN OF 21" OF | | CLEARANCE IN FRONT OF THE WC TO THE TUB PLEASE SHOW OM | | THE PLAN. PER FBC RES P2705.1(5) | | | | 3. COMPLY WITH ALL OTHER TRADE COMMENTS. PER WPB AMEND | | TO FBC 107.2.1 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2017-01-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-01-27 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-01-27 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2017-01-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-01-11 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-01-11 |
Time |
09:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2016-11-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-11-28 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-11-28 |
Time |
10:07 |
Sent To |
|
|
Notes |
2016-11-28 10:23:05 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | | | 1. ROOFING PERMIT REQUIRED. | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | PRODUCTS. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING | | SUBMITTALS. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-11-17 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2016-11-17 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2016-11-17 |
Time |
15:36 |
Sent To |
HIST |
|
Notes |
2016-11-17 16:29:27 | 11/17/16- PASSED | | | | SF-14-C3 | | 15,681SQFT. LOT | | CORNER IS 18.1FT. MEETING THE 15FT. REQUIREMENT | | FRONT IS 32.1FT. MEETING 25FT. REQUIREMENT | | REAR IS 17.25FT. MEETING 15FT. REQUIREMENT | | NO GARAGE | | LOT COVERAGE IS 2,658SQFT. MEETING THE 3,136.2SQFT. | | LIMIT | | FLOOR TO AREA RATIO IS 3,086 MEETING THE 6,272.4SQFT. | | 18FT. TALL MEETS 30FT. LIMIT | | ONE KITCHEN IS ONE UNIT | | | | | | PLEASE CONTACT | | NATHAN WIRA | | [email protected] | | (561)822-1442 |
|
|