Plan Review Details - Permit 16110543
Plan Review Stops For Permit 16110543
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-01-11 Cont ID  
Sent By cthroop Date 2017-01-11 Time 11:25 Rev Time 0.00
Received By cthroop Date 2017-01-11 Time 09:42 Sent To E
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-11-28 Cont ID  
Sent By cthroop Date 2016-11-28 Time 10:25 Rev Time 0.00
Received By cthroop Date 2016-11-28 Time 09:56 Sent To E
Notes
2016-11-28 10:35:04BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 1. ROOFING PERMIT REQUIRED.
 2. PALM BEACH COUNTY IMPACT FEES REQUIRED.
 3. PROVIDE DETAIL FOR SPIRAL STAIRS AT NEW DECK.
 4. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS AT
 WINDOW LOCATION #3.
 5. PROVIDE DETAIL FOR BALCONY GUARDS.
 6. PROVIDE ENERGY SUBMITTALS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW
 MULLION SUBMITTALS.
  
 SECTION R312 GUARDS AND WINDOW FALL PROTECTION
 GUARDS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS
 R312.1.1 THROUGH R312.1.4.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-01-11 Cont ID  
Sent By mvaldes Date 2017-01-11 Time 14:07 Rev Time 0.00
Received By mvaldes Date 2017-01-11 Time 13:13 Sent To P
Notes
2017-01-11 14:07:55ROUTED TO GJ.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-11-28 Cont ID  
Sent By mvaldes Date 2016-11-28 Time 13:11 Rev Time 0.00
Received By mvaldes Date 2016-11-28 Time 11:31 Sent To P
Notes
2016-11-28 13:12:48JOB PERMIT NUMBER: 16110543 (REVISION)
 JOB ADDRESS: 336 MARLBOROUGH RD
 WEST PALM BEACH FLORIDA
 DATE: NOVEMBER 28, 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC
 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA
 BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH
 AMENDMENTS. SEE BELOW A LIST OF ITEMS NOTED.
  
 1] EVERY SEPARATE BUILDING OR AN ADDITION TO AN
 EXISTING BUILDING FOR WHICH A PERMIT FOR NEW
 CONSTRUCTION IS ISSUED AND HAVING A FOSSIL-FUEL-BURNING
 HEATER OR APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE,
 OR OTHER FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON
 MONOXIDE AS BYPRODUCT OF COMBUSTION SHALL HAVE AN
 OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN 10
 FEET (3048 MM) OF EACH ROOM USED FOR SLEEPING PURPOSES.
 FBC-R 315.1
  
 2] SHOW A SMOKE ALARM IN THE FIRST FLOOR LOWER LEVEL
 STAIRWAY LANDING PER FBC-R 314.3
  
 3] BREAKFAST ROOM MISSING A RECEPTACLE IN SHORT WALL
 SPACE SECTION BY THE 1ST FLOOR DOUBLE DOOR PER FBC-R
 SECTION E3902.2.2 (2' WALL SPACE).
  
 4] PROVIDE RECEPTACLE & LIGHTING OUTLETS IN BEDROOM 1 &
 2 IN ACCORDANCE WITH FBC-R SECTIONS E3901.2.1 & E3903.2
  
 5] PROVIDE AN ELECTRICAL RISER DIAGRAM, INCLUDE
 GROUNDING & CONDUIT DETAIL. FBC-107
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER
 RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES
 WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER
 QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME
 DIRECTLY.
  
 1ST REVIEW FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-11-21 Cont ID  
Sent By fmittner Date 2016-11-21 Time 14:04 Rev Time 0.00
Received By fmittner Date 2016-11-21 Time 14:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-01-31 Cont ID  
Sent By lmarchan Date 2017-01-31 Time 07:59 Rev Time 0.00
Received By lmarchan Date 2017-01-24 Time 16:34 Sent To  
Notes
2017-01-25 16:34:54RESUB OF REVISION ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-01-11 Cont ID  
Sent By gjohnson Date 2017-01-11 Time 16:47 Rev Time 0.00
Received By gjohnson Date 2016-12-19 Time 15:29 Sent To  
Notes
2016-12-20 15:29:39R09

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-14 Cont ID  
Sent By cthroop Date 2016-12-14 Time 15:39 Rev Time 0.00
Received By cthroop Date 2016-12-14 Time 14:36 Sent To  
Notes
2016-12-14 14:36:53IMPACT FEES ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-29 Cont ID  
Sent By gjohnson Date 2016-11-29 Time 09:06 Rev Time 0.00
Received By gjohnson Date 2016-11-10 Time 12:58 Sent To  
Notes
2017-01-10 18:49:17ROUTED TO CHRIS THROOP 1/10/2017 - JORGE V.
2016-11-14 12:58:18R05

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-12-14 Cont ID  
Sent By cthroop Date 2016-12-14 Time 15:39 Rev Time 0.00
Received By cthroop Date 2016-12-14 Time 15:39 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-11-28 Cont ID  
Sent By cthroop Date 2016-11-28 Time 10:19 Rev Time 0.00
Received By cthroop Date 2016-11-28 Time 10:07 Sent To  
Notes
2016-11-28 10:20:27BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-01-30 Cont ID  
Sent By jvalido Date 2017-01-30 Time 17:22 Rev Time 0.00
Received By jvalido Date 2017-01-30 Time 16:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date   Cont ID  
Sent By   Date 2017-01-10 Time   Rev Time 0.00
Received By jvalido Date 2017-01-10 Time 18:05 Sent To  
Notes
2017-01-10 18:40:57CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE MECHANICAL PLANS SHOWING HVAC FOR ENTIRE
 HOME. PROVIDE MAIN DUCT SIZES, BRANCH SIZES, GRILL
 SIZES, CFM QUANTITIES. DIFFERENTIATE EXISTING AND NEW
 DUCT WORK.
 (2) PROVIDE BALANCE RETURN FROM ALL BEDROOMS
 (3) PROVIDE EXHAUST FROM ALL BATHROOMS
  
 FLORIDA ENERGY CODE FBC 2014
  
 (4) FORMS R405-2014 REQUIRES SIGNATURE AT OWNER /AGENT.
 (5) HEAT LOAD CALCULATIONS MUST HAVE NAME AND SIGNATURE
 OF PREPARED BY.
 (6) PROVIDE AHRI SHEET
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-11-28 Cont ID  
Sent By skennedy Date 2016-11-28 Time 11:12 Rev Time 0.00
Received By skennedy Date 2016-11-28 Time 11:12 Sent To  
Notes
2016-11-28 11:18:021ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 FBC- 107.3.5.3 ? PROVIDE A MECHANICAL & EQUIPMENT PLAN
 TO SHOW SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER
 FBC-R M15.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R403.6.1 EQUIPMENT SIZING.
 HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN
 ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT
 LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR
 OTHER APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES, BASED ON BUILDING LOADS FOR THE
 DIRECTIONAL ORIENTATION OF THE BUILDING. THE
 MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR
 UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH
 THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN
 CONDITIONS DESCRIBED IN SECTION R302.1. THIS CODE DOES
 NOT ALLOW DESIGNER SAFETY FACTORS, PROVISIONS FOR
 FUTURE EXPANSION OR OTHER FACTORS WHICH AFFECT
 EQUIPMENT SIZING. SYSTEM SIZING CALCULATIONS SHALL NOT
 INCLUDE LOADS CREATED BY LOCAL INTERMITTENT MECHANICAL
 VENTILATION SUCH AS STANDARD KITCHEN AND BATHROOM
 EXHAUST SYSTEMS.
  
 R403.6.1.1 COOLING EQUIPMENT CAPACITY.
 COOLING ONLY EQUIPMENT SHALL BE SELECTED SO THAT ITS
 TOTAL CAPACITY IS NOT LESS THAN THE CALCULATED TOTAL
 LOAD, BUT NOT MORE THAN 1.15 TIMES GREATER THAN THE
 TOTAL LOAD CALCULATED ACCORDING TO THE PROCEDURE
 SELECTED IN SECTION 403.6, OR THE CLOSEST AVAILABLE
 SIZE PROVIDED BY THE MANUFACTURER?S PRODUCT LINES. THE
 CORRESPONDING LATENT CAPACITY OF THE EQUIPMENT SHALL
 NOT BE LESS THAN THE CALCULATED LATENT LOAD.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-01-11 Cont ID  
Sent By gjohnson Date 2017-01-11 Time 16:47 Rev Time 0.00
Received By gjohnson Date 2017-01-11 Time 16:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-11-29 Cont ID  
Sent By gjohnson Date 2016-11-29 Time 08:57 Rev Time 0.00
Received By gjohnson Date 2016-11-29 Time 07:07 Sent To  
Notes
2016-11-29 08:37:291ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1.THE WC IN MASTER MATH SHOULD TIE INTO THE BRANCH
 DRAIN FOR MASTER BATHROOM NOT THE STACK. PER WPB AMEND
 TO FBC 107.2.1
  
 2.GUEST BATH 2 IT IS REQUIRED TO HAVE A MIN OF 21" OF
 CLEARANCE IN FRONT OF THE WC TO THE TUB PLEASE SHOW OM
 THE PLAN. PER FBC RES P2705.1(5)
  
 3. COMPLY WITH ALL OTHER TRADE COMMENTS. PER WPB AMEND
 TO FBC 107.2.1
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2017-01-27 Cont ID  
Sent By cthroop Date 2017-01-27 Time 11:28 Rev Time 0.00
Received By cthroop Date 2017-01-27 Time 11:28 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2017-01-11 Cont ID  
Sent By cthroop Date 2017-01-11 Time 10:59 Rev Time 0.00
Received By cthroop Date 2017-01-11 Time 09:42 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2016-11-28 Cont ID  
Sent By cthroop Date 2016-11-28 Time 10:20 Rev Time 0.00
Received By cthroop Date 2016-11-28 Time 10:07 Sent To  
Notes
2016-11-28 10:23:05BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 1. ROOFING PERMIT REQUIRED.
 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM
 PRODUCTS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING
 SUBMITTALS.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2016-11-17 Cont ID  
Sent By njwira Date 2016-11-17 Time 16:26 Rev Time 0.00
Received By njwira Date 2016-11-17 Time 15:36 Sent To HIST
Notes
2016-11-17 16:29:2711/17/16- PASSED
  
 SF-14-C3
 15,681SQFT. LOT
 CORNER IS 18.1FT. MEETING THE 15FT. REQUIREMENT
 FRONT IS 32.1FT. MEETING 25FT. REQUIREMENT
 REAR IS 17.25FT. MEETING 15FT. REQUIREMENT
 NO GARAGE
 LOT COVERAGE IS 2,658SQFT. MEETING THE 3,136.2SQFT.
 LIMIT
 FLOOR TO AREA RATIO IS 3,086 MEETING THE 6,272.4SQFT.
 18FT. TALL MEETS 30FT. LIMIT
 ONE KITCHEN IS ONE UNIT
  
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442