Plan Review Stops For Permit 16110097 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2016-12-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-12-30 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-12-30 |
Time |
12:00 |
Sent To |
|
|
Notes |
2017-01-31 13:34:33 | I PASSED THE ADDRESING FAILED STOP AND PUT A NOTE ON | | S.HILL DESK; ISSUED PERMIT RES | 2016-12-30 12:02:49 | PLEASE HAVE THE PROPERTY MANAGER CONTACT MICHAEL ORIO | | REGARDING ADDRESS ASSIGNMENTS. | | | | MICHAEL ORIO | | GIS SUPPORT SPECIALIST | | CITY OF WEST PALM BEACH | | INFORMATION TECHNOLOGY DEPARTMENT | | 401 CLEMATIS STREET ? WEST PALM BEACH ? FLORIDA 33401 | | P: 561.494.1080 | | [email protected] | | | | PLEASE NOTIFY [email protected] WHEN THIS HAS BEEN DONE. | | THIS ITEM SHOULD NOT DELAY PERMIT ISSUANCE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-01-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-01-03 |
Time |
18:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-12-29 |
Time |
17:59 |
Sent To |
|
|
Notes |
2017-01-03 18:10:33 | PER ARCHITECT, THE MAIL ROOM IS EXISTING AND NO WORK IS | | PROPOSED |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-11-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2016-11-14 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2016-11-14 |
Time |
07:41 |
Sent To |
|
|
Notes |
2016-11-14 08:01:24 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. A SEPARATE PERMIT IS REQUIRED FOR EACH SUITE, FBC | | 107. INCLUDE THE SUITE NUMBER ON EACH APPLICATION. | | | | 2. REVISE PLAN TO INCLUDE OCCUPANT LOAD FOR EACH UNIT, | | FBC 5TH EDITION BUILDING 1004. | | | | 3. REVISE PLAN TO INCLUDE SQUARE FOOT AREA FOR EACH | | UNIT, FBC 107. | | | | 4. REVISE PLAN TO PROVIDE A ROOM DESIGNATION FOR THE | | UNLABELED AREA WHICH OPENS INTO THE ELEVATOR LOBBY, FBC | | 107. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-01-12 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-12 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2017-01-12 |
Time |
15:59 |
Sent To |
|
|
Notes |
2017-01-12 17:06:03 | PROVISO 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | 1] APPLY ARC-FLASH HAZARD WARNING LABEL TO ELECTRICAL | | EQUIPMENT LIKELY TO BE WORKED ON WHILE ENERGIZED PER | | NEC 110.16. | | | | 2] PULL BOX SHALL BE SIZED IN ACCORDANCE WITH NEC | | 314.28. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-11-09 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-11-09 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-11-09 |
Time |
08:53 |
Sent To |
|
|
Notes |
2016-11-09 10:42:53 | JOB PERMIT NUMBER: 16110097 | | JOB ADDRESS: 400 S AUSTRALIAN AVE | | WEST PALM BEACH FLORIDA | | DATE: NOVEMBER 9, 2016 | | ELECTRICAL PLAN REVIEW COMMENTS | | | | THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC | | 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | AMENDMENTS. SEE BELOW A LIST OF ITEMS NOTED. | | | | 1] CLARIFY IF A NEW ELECTRIC DRINKING FOUNTAIN IS BEING | | INSTALLED? IF SO GFCI PROTECTION WILL BE REQUIRED PER | | NEC 422.52. | | | | 2] PLEASE PROPERLY ADJUST CIRCUIT DESIGNATION LABELING | | TO MATCH PANEL "L". FBC-107 | | | | 3] PLEASE LABEL & IDENTIFY ALL ROOMS ON THE PLAN. | | FBC-107 | | | | 4] ALL WORK ASSOCIATED WITH LOW VOLTAGE SYSTEM WILL BE | | UNDER A SEPARATE PERMIT. A NOTE WILL SUFFICE. | | | | 5] PROVIDE A RISER DIAGRAM TO INCLUDE THE RELOCATION OF | | PANEL "L" SHOW WIRE & CONDUIT SIZES. IF THE EXISTING | | PANEL CABINET WILL BE USED AS A J-BOX ALL PENETRATIONS | | MUST BE SEALED & THE ENCLOSURE SHALL BE MARKED WITH A | | WARNING LABEL IDENTIFYING THE DISCONNECTING MEANS PER | | NEC 312.8(3). | | | | 6] ADD A GENERAL ELECTRICAL NOTE STATING THAT AT LEAST | | 50 % OF ALL 125 V 15 & 20 AMP RECEPTACLES INSTALLED IN | | PRIVATE OR OPEN OFFICES INCLUDING MODULAR PARTITIONS | | SHALL BE CONTROLLED BY AN AUTOMATIC CONTROL DEVICE PER | | FBC-E SECTION C405.7.1 CONFORMANCE WITH ASHREA 90.1, | | 8.4.2. | | | | 7] SHOW LIGHTING CONTROLS IN OFFICE AREAS; PLEASE | | REFERENCE FBC-E SECTION C405 FOR LIGHTING REDUCTION, | | AUTOMATIC TIME SWITCHES, OCCUPANCY SENSOR & ETC. | | | | 8] THE NEW LOCATION OF PANEL "L" MAY COMPROMISE THE | | FIRE RATING OF THE WALL. PLEASE PROVIDE CALRIFICATION | | IF THE INSTALLATION IS SURFACE MOUNTED OR SHOW | | COMPLIANCE WITH FBC-714 & NEC 300.21. | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER | | RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES | | WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER | | QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME | | DIRECTLY. | | | | 1ST REVIEW FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2016-12-21 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2016-12-21 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2016-12-21 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2016-11-07 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2016-11-07 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2016-11-07 |
Time |
10:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-01-30 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-01-30 |
Time |
13:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-01-12 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2017-01-12 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-12-15 |
Time |
09:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-11-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-11-27 |
Time |
05:33 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-11-02 |
Time |
09:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2017-01-30 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-01-30 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-01-30 |
Time |
13:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-12-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-12-28 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-12-28 |
Time |
09:08 |
Sent To |
|
|
Notes |
2016-12-28 09:14:14 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16110097 | | 12/28/16 | | | | 1) PROVIDE THE DIMENSIONS OF THE RETURN AIR GRILLS AT | | THE MECHANICAL ROOM- 601.5 | | | | 2) SHOW THE LOCATION(S) OF THE REQUIRED SMOKE | | DETECTOR(S) IN THE MECHANICAL ROOM- SECTION 606.2.2 | | | | 3) SHOW THE LOCATION OF THE O/A DUCT. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-11-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-09 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-09 |
Time |
07:54 |
Sent To |
|
|
Notes |
2016-11-09 08:08:16 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16110097 | | 11/9/16 | | | | 1) SHEET M-1: PLEASE IDENTIFY ALL THE ROOMS AND SPACES | | ON THE PLAN- SECTION 107.2.1 WPB AMENDMENTS TO THE FBC. | | | | 2) M-1: PROVIDE THE MAKES AND MODELS AND COOLING AND | | HEATING CAPACITIES OF THE EXISTING AC SYSTEMS. | | | | 3) M-1: CORRECT NOTE #2 INDICATING 1152 SF TO SQUARE | | INCHES. | | | | 4) REFER TO SECTION 602.1: PLENUMS SHALL BE LIMITED TO | | ONE FIRE AREA. PROVIDE A DUCTED RETURN TO AC-2 FROM THE | | WEST TENANT SPACE. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2017-01-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-01-12 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-01-12 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2016-11-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-11-27 |
Time |
05:33 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-11-27 |
Time |
05:06 |
Sent To |
|
|
Notes |
2016-11-27 05:27:20 | 1) SUBMIT A SANITARY AND WATER RISER FOR BOTH BREAK | | ROOM SINKS. THE PLUMBING SHEET SHOWS THE DISCHARGE LINE | | FROM THE SUMP TANK BUT WHERE ARE THE LINES FROM THE TWO | | SINKS THAT ARE DISCHARGING INTO THE TANK? SHOW THE SIZE | | OF EACH LINE FROM THE FIXTURES INTO THE TANK.WPB AMEND. | | TO FBC SEC. 107.3.5.3. | | 2) THE SANITARY CONNNECTION FROM THE SUMP TANK TO THE | | EXISTING BUILDING DRAINAGE SYSTEM SHALL COMPLY WITH | | 2014 FBC-PLUMBING SEC.712.3.5. | | | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|