Plan Review Details - Permit 16110061
Plan Review Stops For Permit 16110061
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2017-06-30 Cont ID  
Sent By shill Date 2017-06-30 Time 06:40 Rev Time 0.00
Received By shill Date 2017-06-30 Time 06:40 Sent To  
Notes
2017-06-30 06:41:06NEW PROPOSED ADDRESS: 1900 BANYAN CLUB RD

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2017-02-16 Cont ID  
Sent By shill Date 2017-02-16 Time 14:13 Rev Time 0.00
Received By shill Date 2017-02-16 Time 14:13 Sent To  
Notes
2017-02-16 14:16:21PLEASE SEND A COPY OF THE PROPOSED PLAT, SITE PLAN,
 INCLUDING PROPOSED STREET NAMES AND PROPOSED ADDRESSES,
 TO:
  
 MICHAEL ORIO
 [email protected]
 561-494-1080
  
  

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 2022-08-15 Cont ID  
Sent By scwelter Date 2022-08-15 Time 16:42 Rev Time 0.00
Received By scwelter Date 2022-08-15 Time 16:49 Sent To  
Notes
2022-08-15 16:48:55SUBJECT TO PUBLIC ART REQUIREMENT. CONTACT
 [email protected]
  
 ART ASSESSMENT APPLICATION NEEDS TO BE COMPLETED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2018-04-07 Cont ID  
Sent By shill Date 2018-04-07 Time 13:49 Rev Time 0.00
Received By shill Date 2018-04-07 Time 13:16 Sent To  
Notes
2018-04-07 13:52:41****PROVISOS****
 REVISED 4/13/18
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 A. PRODUCT APPROVALS ARE DEFERRED SUBMITTALS. ALL
 PRODUCT APPROVALS, DELEGATED ENGINEERING, AND OTHER
 SUBMITTALS REQUIRED BY THE INSPECTOR ARE TO BE
 SUBMITTED AND REVIEWED BY OUR DEPARTMENT PRIOR TO
 INSTALLATION. ALL SUBMITTALS ARE TO BE REVIEWED BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL TO THE BUILDING
 DIVISION, FBC B 1609.
  
 B. A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF PRODUCT
 APPROVAL INDICATING THE ASSEMBLY PROPOSED AND
 ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE
 ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR
 TO ROOF WORK COMMENCEMENT.
  
 C. MOVEABLE (NONFIXED) SEATING WAS NOT REVIEWED.
  
 D. REPLAT REQUIRED PRIOR TO CO. A COPY OF THE RECORDED
 REPLAT IS TO BE PROVIDED VIA EMAIL.
  
 E. RESTRICTIVE COVENANT REQUIRED PRIOR TO C.O. A COPY
 OF THE RECORDED DOCUMENT IS TO BE PROVIDED VIA EMAIL.
 (RECEIVED ON 4/13/18)
  
 F. SEPARATE PERMITS ARE REQUIRED; ONLY BUILDING,
 MECHANICAL, ELECTRICAL, PLUMBING ARE INCLUDED IN THIS
 REVIEW. SEPARATE PERMITS, FEES AND PLANS ARE REQUIRED
 FOR FIRE ALARM, FIRE SPRINKLER, FIRE UNDERGROUND LINE,
 PARKING LOT, GAS, LOW VOLTAGE, LANDSCAPING, AND OTHER
 SUCH ITEMS.
  
 G. THIS PROJECT HAS A SEPARATE ENGINEERING PERMIT;
 THERE MAY BE CONFLICTS BETWEEN THESE CIVIL SHEETS AND
 THE ISSUED ENGINEERING PERMIT. ISSUED AT CONTRACTOR'S
 RISK. APPLICANT IS TO REVISE ANY SHIEETS WHICH AFFECT
 BUILDING OR FIRE CODE COMPLIANCE.
  
 H. DIGITAL SIGNATURE FOR HOLLOWCORE SHOP DRAWINGS IS
 NOT ACCEPTABLE TO FBPE . PLEASE PROVIDE A PAPER SIGNED
 AND SEALED ORIGINAL TO ADDRESS. THIS MUST BE DONE PRIOR
 TO INSTALLATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2018-02-05 Cont ID  
Sent By shill Date 2018-02-05 Time 08:17 Rev Time 0.00
Received By shill Date 2018-02-05 Time 06:10 Sent To  
Notes
2018-02-05 08:55:19****CORRECTIONS****
 REVISED 2/21/18
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. SEE COMMENTS FROM PREVIOUS LISTS, ITEM #16: REVISE
 PLAN TO SHOW COMPLIANCE WITH FBC B 705, TABLES 602,
 705.8.
  
 3RD REVIEW, SHEET A004 WAS PRELIMINARILY REVIEWED AND
 AGREED UPON IN A MEETING - A RESTRICTIVE COVENANT IS TO
 BE FILED TO LIMIT CONSTRUCTION ON THE ADJACENT LOT.
  
 PLEASE PROVIDE TIMELINE FOR THE RECORDING OF THE
 RESTRICTIVE COVENANT AND THE REPLAT. SEE ALSO NEW
 COMMENT #2.
  
 2. A004 DOES NOT MATCH A005 AND OTHER SHEETS. SHEET
 A005 AND OTHER PAGES (SUCH AS A201) DEPICT THE CORNER
 OF THE ROOF OVERHANG EXTENDING OVER THE ADJACENT
 PROPERTY. ALTHOUGH A RESTRICTIVE COVENANT ADDRESSING
 THE PROPOSED NONCOMPLIANT CONDITION AT THIS LOCATION, I
 DO NOT RECALL EXTENSION OVER THE PROPERTY LINE. AS THE
 TWO PLANS CONFLICT, CLARIFY WHAT IS PROPOSED.
  
 2/21/18 PER BUILDING OFFICIAL, OK FOR OVERHANG TO
 ENCROACH PROPERTY LINE INTO THE AREA COVERED BY THE
 RESTRICTIVE COVENANT.
  
 3. SOME OF THE STRUCTURAL PAGES HAVE A DIGITAL
 SIGNATURE WHICH DO NOT COMPLY WITH FAC61G15-23 (STATES
 THE DOCUMENT WAS SIGNED BY "DOCUSIGN" RATHER THAN
 C.TIEDGE,PE. THIS HAS BEEN DISCUSSED WITH ENGINEER AND
 SENT TO FBPE TO ANSWER HER QUESTIONS. FOR THE STRUCTURE
 PERMIT, ENGINEER HAD ADDRESSED THE ISSUE BY UTILIZING A
 DIGITAL SEAL FROM A DIFFERENT VENDOR.
  
 SHEETS WHICH NEED A NEW DIGITAL SIGNATURE (SIGNED BY
 "DOCUSIGN" RATHER THAN ENGINEER): S001, S002, S003,
 S200, S302, S303, S304, S305
  
 S201, S300 (MESSAGE: SIGNED AND ALL SIGNATURES ARE
 VALID, BUT WITH UNSIGNED CHANGES AFTER THE LAST
 SIGNATURE),
  
 NEW COMMENTS:
  
 4. HOLLOWCORE SHOP DRAWINGS ARE NOT SIGNED AND SEALED
 AND ARE NOT REVIEWED BY SEOR, FAC61G15-30.005. THIS WAS
 ALSO NOT SUBMITTED WITH THE STRUCTURE PERMIT. WHAT IS
 THE PROPOSED INSTALLATION DATE? ALL DELEGATED
 ENGINEERING IS TO BE SUBMITTED, REVIEWED, AND APPROVED
 PRIOR TO INSTALLATION. THIS MAY BE A PROVISO ITEM UPON
 REQUEST, REQUIRED PRIOR TO INSTALLATION, IF THERE IS
 ADEQUATE TIME TO DO SO (ALLOW AT LEAST 30 DAYS AFTER
 PERMIT ISSUANCE BEFORE SETTING OF MECHANICAL EQUIPMENT
 FOR SUBMITTAL AND REVIEW OF REQUIRED DOCUMENTS).
  
 5. MECHANICAL EQUIPMENT ANCHOR INFORMATION WAS
 PROVIDED. THIS WAS NOT REVIEWED BY DOR, AND DOES NOT
 INDICATE THE METHOD OF FASTENING PROPOSED, FBC B 1609,
 FBC 107. AS A STRUCTURE PERMIT HAS ALREADY BEEN ISSUED,
 PROVIDE PROPOSED INSTALLATION DATE. THIS MAY BE A
 PROVISO ITEM UPON REQUEST, REQUIRED PRIOR TO
 INSTALLATION, IF THERE IS ADEQUATE TIME TO DO SO (ALLOW
 AT LEAST 30 DAYS AFTER PERMIT ISSUANCE BEFORE SETTING
 OF MECHANICAL EQUIPMENT FOR SUBMITTAL AND REVIEW OF
 REQUIRED DOCUMENTS).
  
 6. A202, A203, BLUE DOTS WERE ADDED TO THE PLAN. THIS
 APPEARS TO BE RELATED TO PLUMBING. CLARIFY WHY THIS
 INFORMATION WAS ADED TO THE PLAN FOR THIS REVIEW; THIS
 INFORMATION IS NOT TYPICALLY SHOWN ON THIS PAGE. EITHER
 REMOVE OR PROVIDE A LEGEND. ADDITIONAL REVIEW BY
 PLUMBING MAY BE REQUIRED, FBC 107. CHECK ALL PAGES.
  
 7. NA
  
 8. THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING
 PROVISOS:
  
 A. PRODUCT APPROVALS WERE NOT SUBMMITTED. ALL PRODUCT
 APPROVALS ARE TO BE SUBMITTED AND REVIEWED PRIOR TO
 INSTALLATION. PRODUCT APPROVALS ARE TO BE REVIEWED BY
 DESIGNER OF RECORD PRIOR TO SUBMITTALM, FBC B 1609.
  
 B. A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF PRODUCT
 APPROVAL INDICATING THE ASSEMBLY PROPOSED AND
 ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE
 ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR
 TO ROOF WORK COMMENCEMENT.
  
 C. MOVEABLE (NONFIXED) SEATING WAS NOT REVIEWED.
  
 D. REPLAT REQUIRED PRIOR TO CO. A COPY OF THE RECORDED
 REPLAT IS TO BE PROVIDED VIA EMAIL.
  
 E. RESTRICTIVE COVENANT REQUIRED PRIOR TO C.O. A COPY
 OF THE RECORDED DOCUMENT IS TO BE PROVIDED VIA EMAIL.
  
 F. SEPARATE PERMITS ARE REQUIRED; ONLY BUILDING,
 MECHANICAL, ELECTRICAL, PLUMBING ARE INCLUDED IN THIS
 REVIEW. SEPARATE PERMITS, FEES AND PLANS ARE REQUIRED
 FOR FIRE ALARM, FIRE SPRINKLER, FIRE UNDERGROUND LINE,
 PARKING LOT, GAS, LOW VOLTAGE, LANDSCAPING, AND OTHER
 SUCH ITEMS.
  
 G. THIS PROJECT HAS A SEPARATE ENGINEERING PERMIT;
 THERE MAY BE CONFLICTS BETWEEN THESE CIVIL SHEETS AND
 THE ISSUED ENGINEERING PERMIT. ISSUED AT CONTRACTOR'S
 RISK. APPLICANT IS TO REVISE ANY SHIEETS WHICH AFFECT
 BUILDING OR FIRE CODE COMPLIANCE.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-07-05 Cont ID  
Sent By shill Date 2017-07-05 Time 09:51 Rev Time 0.00
Received By shill Date 2017-06-27 Time 15:25 Sent To  
Notes
2017-06-30 07:15:43****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 STRUCTURE PERMIT IS TO BE ISSUED PRIOR TO ISSUANCE OF
 THIS PERMIT. IF STRUCTURE PERMIT IS NOT ISSUED, VALUE
 IS TO BE ADJUSTED.
  
 1-15. OK
  
 16. FROM PREVIOUS LIST: REVISE PLAN TO SHOW COMPLIANCE
 WITH FBC B 705, TABLES 602, 705.8. DISTANCE TO ASSUMED
 PROPERTY LINE OR PROPERTY LINE NOT CLEAR, COMPLIANCE
 NOT CLEAR. PROVIDE A SITE PLAN, OR REVISE THE SITE
 PLAN, TO INCLUDE THE PROPERTY LINES, ASSUMED PROPERTY
 LINES, AND DIMENSIONS OF THIS BUILDING TO THE PROPERTY
 LINES, DIMENSION OF ADJACENT BUILDING (OR FUTURE
 ADJACENT BUILDING) TO THE ASSUMED PROPERTY LINE OR
 PROPERTY LINE.
  
 2ND REVIEW, A004, A SITE PLAN SHOWING POD LINES WAS
 PROVIDED. THE EAST DISTANCE TO PROPERTY LINE IS SHOWN
 AS 14'2 1/8", BUT THIS IS SHOWN TO A POINT WHICH IS NOT
 WORST CASE. THE NORTHEAST CORNER OF THE BUILDING
 APPEARS TO TOUCH THE PROPERTY LINE ON AN ANGLE. THE
 OVERHAND APPEARS TO EXTEND OVER THE POD BOUNDARY LINE.
 THE NORTH SIDE OF THE BUILDING APPEARS TO SHOW A
 TRELLIS WHICH EXTENS TO "PBA #4 BOUNDARY LINE".
  
 REVISE AND SHOW COMPLIANCE WITH FBC B 705, TABLES 602,
 705.8, 705.2 (PROJECTIONS).
  
 REVISE PLAN TO CLARIFY, WHAT IS "POD BOUNDARY LINE"? IS
 THIS PROPERTY UNDERGOING A REPLAT? IS THIS THE PROPOSED
 PROPERTY LINE? IF THIS IS NOT THE PROPOSED NEW PROPERTY
 LINE (AFTER REPLAT), REVISE PLAN TO SHOW PROPOSED NEW
 PROPERTY LINES (AFTER REPLAT).
  
 FEEL FREE TO CONTACT ME TO DISCUSS RESOLUTIONS TO BE
 APPROVED PRIOR TO RESUBMITTAL.
  
 17-27. OK
  
 28. FBC A 226, 902, DINING SURFACES, REVISE PLAN TO
 SHOW COMPLIANCE.
  
 2ND REVIEW, BANYAN GRILL DOES NOT APPEAR TO HAVE AN
 ACCESSIBLE SECTION. PLEASE EXPLAIN RATIONALE.
  
 29-49. OK
  
 THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING PROVISOS:
  
 A. PRODUCT APPROVALS NOT SUBMMITTED. ALL PRODUCT
 APPROVALS ARE TO BE SUBMITTED AND REVIEWED PRIOR TO
 INSTALLATION. PRODUCT APPROVALS ARE TO BE REVIEWED BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL.
  
 B. A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF PRODUCT
 APPROVAL INDICATING THE ASSEMBLY PROPOSED AND
 ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE
 ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR
 TO ROOF WORK COMMENCEMENT.
  
 C.PROVIDE A DETAIL FOR THE HORIZONTAL 1 HOUR ASSEMBLY,
 EITHER TESTED ASSEMBLY OR CALCULATED, FBC B 703.2.
 REVISE PLAN TO INCLUDE DAMPERS REQUIRED, OR REVISE PLAN
 TO INCLUDE EXCEPTION.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-21 Cont ID  
Sent By S. Hill Date 2017-03-21 Time 08:19 Rev Time 0.00
Received By shill Date 2017-03-06 Time 11:38 Sent To  
Notes
2017-03-10 15:05:25****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC 1007, FBC A 207, REVISE PLAN TO STATE WHICH
 METHOD OF COMPLIANCE IS ELECTED (IBC 2000 OR IBC 2003).
  
 2. CIRCULATION PATH NOT CLEAR, FBC A 206.3; IN
 PARTICULAR, COMMUNICATION BETWEEN GARAGE AND CLUBHOUSE
 FLOORS. PROVIDE INFORMATION REGARDING THE USE OF THE
 SPACES AND HOW OCCUPANTS, BOTH EMPLOYEES AND GUESTS,
 ACCESS THE SPACES. IT IS RECOMMENDED TO SEND THIS
 INFORMATION VIA EMAIL PRIOR TO RESUBMITTAL IN ORDER TO
 PROVIDE A COMPLETE REVIEW.
  
 PLAN SHOWS A STAIR WHICH APPEARS TO BE AN EMPLOYEE
 STAIR AS IT IS LOCATED IN EMPLOYEE AREAS
 (DELIVERY/DUMPSTER AREA ON 1ST FLOOR, MAINTENANCE AREA
 ON BASEMENT LEVEL). ACCESSIBLE ROUTE, VERTICAL
 ACCESSIBILITY NOT CLEAR BETWEEN LEVELS. IT IS NOT CLEAR
 UNDER WHICH EXEPTION VERTICAL ACCESSIBLITY IS NOT
 PROVIDED. USE OF THE GARAGE AREA AND THE NEED FOR
 EMPLOYEES (OR OTHER OCCUPANTS) TO TRAVEL FROM ONE FLOOR
 TO THE OTHER IS NOT CLEAR.
  
 3. A101, CLARIFY USE OF GOLF CART PARKING FACILITY. WHO
 WILL USE THIS AREA, EMPLOYEES ONLY OR VISITORS? WILL
 GOLF CARTS BE RENTED? WILL CARS BE SELF PARKED OR
 PARKED BY EMPLOYEES? A MAINTENANCE AREA IS SHOWN; IS
 THIS FOR FACILITY OWNED CARTS OR PRIVATELY OWNED CARTS?
 IS THIS GARAGE PARKING (RESIDENTS OR OTHERS SELF PARK
 THEIR CARTS), OR IS THIS STORAGE (FACILITY OWNED CARTS
 BROUGHT OUTSIDE AS NEEDED BY EMPLOYEES)? FBC A
 206.2.15, 1006. THE ACCESSIBLE ROUTE REQUIRED IS NOT
 CLEAR. REVISE PLAN TO ADDRESS ACCESSIBILITY ISSUES.
  
 4. EXIT FROM KITCHEN ROOM 100, SHEET A003, THE EXIT
 DISCHARGE IS NOT CLEAR. THE EXIT OPENS INTO THE
 DELIVERY & DUMPSTER AREA #130, AND A GATE WHICH
 COMPLIES WITH FBC B1008.1.2 IS NOT PROVIDED; SEE ALSO
 1008.1.1 (4 FT MAX), 1008.2 (GATES TO MEET SAME
 REQUIREMENTS AS DOORS), 1003.1 (REQUIREMENTS APPLICABLE
 TO EXIT DISCHARGE). EXIT DISCHARGE IS TO BE CONTINUOUS
 TO THE PUBLIC WAY, 1027.5.
  
 5. A003, FBC B 1014.2, REVISE PLAN TO EXPLAIN RATIONALE
 OF EXITING THROUGH A DUMPSTER AREA, ESPECIALLY FROM THE
 BASEMENT. IT APPEARS THAT EXITING THROUGH A HIGHER
 HAZARD AREA IS PROPOSED. IF EXIT STRATEGY IS NOT
 REVISED, THIS IS TO BE APPROVED VIA EMAIL BY FIRE AND
 BUILDING PRIOR TO RESUBMITTAL.
  
 6. A003, ACCESSIBLE ROUTE NOT CLEAR FOR COVERED OUTDOOR
 DINING FROM RAMP. THE ROUTE IS BLOCKED BY TABLES,
 REVISE OR CLARIFY.
  
 7. A101 SHOWS A 4" ELEVATION CHANGE AT THE DOOR TO THE
 STAIR. FBC A 403.4, 303.2, FBC B 1008.1.5, IT IS NOT
 CLEAR UNDER WHICH EXCEPTION THIS IS PERMITTED. REVISE
 PLAN TO INCLUDE APPLICABLE EXCEPTION, OR REVISE PLAN TO
 COMPLY WITH THESE CODE SECTIONS. VERIFY THAT THERE ARE
 NO OTHER CHANGES IN ELEVATION IN THE MEANS OF EGRESS,
 WITH THE EXCEPTION OF STAIRS AND RAMPS.
  
 8. A101 AT THE BASE OF THE STAIR AT DUMPSTER AREA,
 THERE APPEARS TO BE A DRAIN. REVISE PLAN TO SHOW
 COMPLIANCE WITH FBC A 302.3 (GRATES), 403.3 (SLOPE).
  
 9. A213, THE RAMP DETAIL, TOP LANDING AT DOOR, DOOR
 DOES NOT APPEAR TO HAVE THE 18" MANEUVERING CLEARANCE
 REQUIRED, REVISE, FBC A 404.2.4.1.
  
 10. A003, REVISE OCCUPANT LOAD TO ROUND UP (CANNOT HAVE
 A FRACTION OF AN OCCUPANT), FBC B TABLE 1004.1.2.
  
 11. A001 BUILDING DATA, A/C SPACE IS 7673, BUT A003
 OCCUPANCY LOAD SCHEDULE APPEARS TO SHOW A TOTAL SF AREA
 UNDER AIR OF 6895, REVISE PLAN TO CLARIFY DISCREPANCY.
 OUTDOOR AREAS, OCCUPANCY LOAD SCHEDULE ALSO APPEAR TO
 HAVE A DISCREPANCY. REVISE TO CLARIFY, SUBTOTALS
 SUGGESTED.
  
 12. A003, REVISE PLAN TO CLARIFY PURPOSE OF COVERED
 GOLF TERRACE 126, AND CLARIFY USE OF 100 SF PER PERSON
 FOR THIS AREA WHICH APPEARS TO BE AN AREA WHERE
 OCCUPANTS MAY CONGREGATE. 100 SF PER PERSON IS USED FOR
 OFFICE SPACE WHICH HAS FURNISHINGS; THIS AREA APPEARS
 TO BE OPEN.
  
 13. A003 IS LACKING MANY DOORS, FBC 107. REVISE PLAN TO
 BE CONSISTENT WITH PROPOSED CONSTRUCTION. FOR INSTANCE,
 NO DOORS LEADING FROM BANYAN GRILLE TO COVERED OUTDOOR
 DINING. DOORS ARE SHOWN ON OTHER SHEETS.
  
 14. A SHEETS SPECIFY ELEVATIONS IN NAVD88. CIVIL SHEETS
 UTILIZE NGVD29 VERTICAL DATUM (SEE MASTER PLAN SHEET 2
 WHICH REFERENCES SFWMD BASIN CRITERIA IN NGVD29, COVER
 SHEET WHICH INCLUDES A NOTE THAT ALL ELEVATIONS ARE
 NGVD29). BOTH A SHEETS AND CIVILS SPEC FINISHED FLOOR
 AT 27.50. CLARIFY VERTICAL DATUM; BOTH ARE TO USE THE
 SAME OR TO INCLUDE CONVERSIONS (NOT A CONVERSION
 FACTOR). NOTE THAT THE CITY STANDARD IS NGVD29 UNTIL
 NEW FIRMS ARE ADOPTED. IT IS RECOMMENDED THAT ALL
 ELEVATIONS BE PROVIDED IN NGVD29.
  
 THE VERTICAL DATUM DISCREPANCY RESULTS IN A CONFLICT OF
 APPROXIMATELY 1.55 FEET. REVISE ELEVATIONS TO BE
 CONSISTENT AND VERIFY ELEVATIONS ON OTHER BUILDINGS FOR
 THIS PROJECT AS THIS MAY AFFECT (AMONG OTHER THINGS)
 ACCESSIBILITY AND UTILITIES.
  
 15. PROVIDE A COPY OF THE SURVEY FOR THIS PARCEL, FBC
 107, FBC TABLE 602, 705.8.
  
 16. REVISE PLAN TO SHOW COMPLIANCE WITH FBC B 705,
 TABLES 602, 705.8. DISTANCE TO ASSUMED PROPERTY LINE OR
 PROPERTY LINE NOT CLEAR, COMPLIANCE NOT CLEAR. PROVIDE
 A SITE PLAN, OR REVISE THE SITE PLAN, TO INCLUDE THE
 PROPERTY LINES, ASSUMED PROPERTY LINES, AND DIMENSIONS
 OF THIS BUILDING TO THE PROPERTY LINES, DIMENSION OF
 ADJACENT BUILDING (OR FUTURE ADJACENT BUILDING) TO THE
 ASSUMED PROPERTY LINE OR PROPERTY LINE.
  
 17. A201 SHOWS TWO ARROWS IN THE HALL AT THE BATHROOMS
 WEST OF THE WOMENS LOCKER, REVISE TO CLARIFY WHAT THE
 GRAPHIC DEPICTS.
  
 18. A003 AND OTHER SHEETS, REVISE PLAN TO SHOW
 MANEUVERING CLEARANCE, PULL SIDE, FOR BOTH DOORS AT
 MENS VESTIBULE 116 (MINIMUM 18"), FBC A 404.2.4.1.
  
 19. SHOE DROP 119, FBC B 1008.1.1, THE ENTRY TO THE
 SPACE IS SHOWN AS 2'6", MINIMUM 32" REQUIRED, REVISE.
 CHECK ALL.
  
 20. THE RESTAURANT BAR AREA INCLUDES TABLES AND CHAIRS
 WHICH APPEAR TO RESTRICT THE ACCESSIBLE ROUTE, FBC A
 CHAPTER 4. REVISE TO CLARIFY REQUIREMENTS AND DESIGN
 INTENT.
  
 22. A701, FBC 1008.1.10, PANIC DEVICES OR FIRE EXIT
 HARDWARE IS REQUIRED ON ALL DOORS AND GATES IN THE
 MEANS OF EGRESS SERVING ASSEMBLY OCCUPANCY WITH AN
 OCCUPANT LOAD OVER 50. THE DOOR LOCKSET GROUPS DOES NOT
 INCLUDE PANIC DEVICES OR FIRE EXIT HARDWARE. REVISE THE
 INTERIOR DOOR SCHEDULE, EXTERIOR DOOR SCHEDULE,
 EXTERIOR WINDOW SCHEDULE, ANY OTHER APPLICABLE AREAS.
  
 IF THERE ARE ANY GATES IN THE MEANS OF EGRESS, REVISE
 PLAN TO INCLUDE THE GATE INFORMATION.
  
 23. I WAS UNABLE TO LOCATE SOME OF THE DOORS TYPES IN
 THE SCHEDULE (SUCH AS TYPE P AND TYPE Q). THE DOORS DO
 NOT APPEAR TO COMPLY WITH THE REQUIREMENTS FOR THIS
 OCCUPANCY. REMOVE (OR X OUT) DOORS WHICH ARE NOT FOR
 THIS PROJECT. IF THEY ARE TO BE INCLUDED, PLEASE DIRECT
 TO THE LOCATION.
  
 24. A801, TOILET, THE TOP OF THE SEAT IS TO BE A MAX OF
 19"; THE DETAIL APPEARS TO DEPICT THE LOWER PART OF THE
 TANK, ABOVE THE LID. REVISE DETAIL TO CLEARLY SHOW THAT
 THE SEAT IS TO BE A MAX OF 19", FBC A 604.4.
  
 25. A802 ADA NOTES INCLUDE AN OLD CODE REFERENCE (FBC
 11-4.13.9), REVISE TO REMOVE.
  
 26. WOMENS 107 ADA, SEE FBC A 604.8.1.6 AND 604.8.1.7
 AND ADVISORY, DOOR IS TO BE DIAGONAL TO THE WATER
 CLOSET.
  
 27. LOCKER ROOMS, CHANGING ROOMS, SEE FBC A 803. REVISE
 PLAN TO SHOW COMPLIANCE WITH ALL REQUIREMENTS.
  
 HTTPS://WWW.ACCESS-BOARD.GOV/GUIDELINES-AND-STANDARDS/R
 ECREATION-FACILITIES/GUIDES/SPORTS-FACILITIES/DRESSING,
 -FITTING,-OR-LOCKER-ROOMS
  
 28. FBC A 226, 902, DINING SURFACES, REVISE PLAN TO
 SHOW COMPLIANCE.
  
 29. RECEPTION AREA A201, OTHER SERVICE OR CHECK OUT
 AREAS (FOR EXAMPLE, SHOE DROP, PRO SHOP) PROVIDE A
 DETAIL FOR THE SERVICE (OR CHECK OUT) COUNTERS, FBC A
 227, 904.
  
 30. PROVIDE A DETAIL FOR THE HORIZONTAL 1 HOUR
 ASSEMBLY, EITHER TESTED ASSEMBLY OR CALCULATED, FBC B
 703.2. REVISE PLAN TO INCLUDE DAMPERS REQUIRED, OR
 REVISE PLAN TO INCLUDE EXCEPTION.
  
 31. A ROOF HATCH IS SHOWN ON A904, BUT I WAS UNABLE TO
 LOCATE THIS ITEM ON THE ENERGY CALC INPUT DATA REPORT,
 EITHER INCLUDE OR ADVISE AS TO WHERE THIS CAN BE FOUND,
 FBC 107. IF A ROOF HATCH IS NOT PROPOSED FOR THIS
 PROJECT, REMOVE OR X OUT DETAIL.
  
 32. DETAIL 9-A904, STRUCTURAL INFORMATION NOT INCLUDED.
 EITHER REVISE TO INCLUDE OR, IF NOT LOCATED ELSEWHERE
 ON THE PLAN, THIS WILL BE A PROVISO ITEM - SUBJECT TO
 INSPECTOR'S DISCRETION, A REVISION MAY BE REQUIRED
 PRIOR TO INSTALLATION.
  
 33. S004 NOMINAL C&C WIND PRESSURES STATE THE PORTE
 COCHERE IS OPEN, SEE DEFINITION, DOES NOT APPEAR TO
 MEET THE CRITERIA FOR AN OPEN BUILDING, SEE ASCE7-10
 26.1.2.2 DEFINITION OF OPEN BUILDING IS A BUILDING WITH
 EACH WALL AT LEAST 80% OPEN. THE PORTE COCHERE IS A
 PORTION OF A BUILDING, ONE WALL ENCLOSED. IF ENGINEER
 DISAGREES, PUT RATIONALE IN WRITING AND SEND VIA EMAIL
 FOR CONSIDERATION PRIOR TO RESUBMITTAL.
  
 34. S102, WOOD CONNECTOR SCHEDULE, MARK 5 SPECS LGT, 1
 3/4" TITENS. SEE CATALOG, SEVERAL DIFFERENT LGT, REVISE
 TO SPECIFY WHICH CONNECTOR. IF LGT 2 IS PROPOSED, THE
 FASTENER SPECIFIED ON THE PLAN IS NOT THE SAME AS THE
 ONE SPECIFIED IN THE SIMPSON CATALOG (1 3/4" TITEN
 RATHER THAN 2 1/4" TITEN 2). REVISE OR PROVIDE
 CALCULATIONS OR OTHER DOCUMENTATION TO SUPPORT USE OF A
 SMALLER FASTENER. CHECK ALL.
  
 35. FS471, THE A SHEETS HAVE A TITLE BLOCK FOR RANDALL
 STOFFT AS ARCHITECT, BUT THE DIGITAL SIGNATURE IS FOR
 DON DURANTE. EITHER REVISE THE TITLE BLOCK AND SEAL TO
 SHOW DON DURANTE AS ARCHITECT, OR HAVE THE SHEETS
 SIGNED AND SEALED BY RANDALL STOFFT. IF THIS IS AN
 ERROR IN THE DIGITAL SIGNATURE, PLEASE CONTACT THE
 ISSUER. ISSUER HAS CONFIRMED THAT THIS IS NOT CORRECT;
 THE "SIGNED BY" NAME IS TO MATCH THE NAME OF THE
 INDIVIDUAL SIGNING.
  
 36. THE SEAL FOR RANDALL STOFFT IS NOT CONSISTENT WITH
 THE DESCRIPTION OF SEAL FAC 61G1-16.002. EITHER REVISE
 OR ADVISE VIA EMAIL THAT ARCHITECT OBJECTS TO THE
 COMMENT. AN EMAIL WILL THEN BE SENT TO FLORIDA BOARD OF
 ARCHITECTS TO DETERMINE WHETHER OR NOT THE SEAL ON THE
 PLAN IS ACCEPTABLE.
  
 IF ARCHITECT OBJECTS TO EITHER COMMENT, PLEASE CONTACT
 ME. IT APPEARS THAT ALL A SHEETS NEED TO BE RESUBMITTED
 WITH A CORRECTED SEAL IMAGE AND CORRECT SIGNATURE &
 SEAL. TO AVOID PERMIT ISSUANCE DELAYS, PLEASE DO NOT
 RESUBMIT WITHOUT THESE TWO ITEMS CORRECTED UNLESS WE
 HAVE DISCUSSED THIS IN ADVANCE.
  
 37. CIVIL SHEETS ARE REQUIRED, SEE FIRE COMMENTS.
 DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS, FS471. IF THIS DESIGN PROFESSIONAL DOES NOT
 HAVE A DIGITAL OR ELECTRONIC SIGNATURE, PLEASE CONTACT
 ME REGARDING ALTERNATE METHODS OF SUBMITTAL.
  
 38. ENERGY INPUT REPORT HAS THE FOLLOWING ISSUES: NO
 DOORS SHOWN, WATER HEATER NOT INCLUDED. CHECK ALL
 ITEMS.
  
 39. INCORPORATE REQUIREMENT OF 23.2 R VALUE FOR THE
 ROOF (PER ENERGY CALCS) INTO THE PLAN, OR ADVISE WHERE
 THIS INFORMATION CAN BE FOUND, FBC 107.
  
 40. PRODUCT APPROVALS NOT SUBMMITTED. ALL PRODUCT
 APPROVALS ARE TO BE SUBMITTED AND REVIEWED PRIOR TO
 INSTALLATION. PRODUCT APPROVALS ARE TO BE REVIEWED BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL.
  
 41. FBC B 406, REVISE PLAN TO NOTE THE GOLFCART GARAGE
 AS AN ENCLOSED PARKING GARAGE. 406.6, IT IS NOT CLEAR
 WHERE THE CO2 CENSORS ARE LOCATED, PLEASE ADVISE.
  
 42. REVISE PLAN TO PROVIDE INFORMATION REGARDING WHAT
 WILL BE STORED IN THE STORAGE AREAS, FBC 107. INCLUDE
 BATTERY STORAGE, CHEMICAL STORAGE; AMOUNTS, MSDS SHEETS
 IF APPLICABLE, FUEL AMOUNTS.
  
 43. DETAIL 9-A904 HAS TEXT WHICH IS NOT LEGIBLE;
 REVISE.
  
 44. DETAIL 9-A904 REFERS TO DETAIL MA/FA/BA 115, ADVISE
 AS TO WHERE THIS CAN BE LOCATED, FBC 107.
  
 45. FBC A 209, 503.5, REVISE PLAN TO INCLUDE CLEARANCE
 REQUIRED AT THE PORTE COCHERE (114" MINIMUM).
  
 46. A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF
 PRODUCT APPROVAL INDICATING THE ASSEMBLY PROPOSED AND
 ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE
 ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR
 TO ROOF WORK COMMENCEMENT.
  
 47. S102 SPECS 5/8" APA SHEATHING, A SHEETS INCLUDE
 DETAILS WITH 19/32", 3/4" IN VARIOUS PLACES (FOR
 INSTANCE, SEE A904), PLEASE CORRELATE.
  
 48. REVISE STRUCTURAL PAGES TO INCLUDE VERTICAL DATUM,
 FBC 107 (FOR INSTANCE, S103). SHEET S201 INCLUDES A TOP
 OF FOOTING EELEVATION IN SECTION 1; 23'2" NAVD. SEE
 OTHER COMMENTS REGARDING VERTICAL DATUM. IF NGVD29 IS
 USED ON OTHER SHEETS, AND NAVD88 IS USED FOR S SHEETS,
 INCLUDE CONVERSION.
  
 49. FP01, NOTE 22, PLEASE COMPLETE INFORMATION.
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2018-03-22 Cont ID  
Sent By jleahy Date 2018-03-22 Time 10:41 Rev Time 0.00
Received By jleahy Date 2018-03-22 Time 10:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-01-30 Cont ID  
Sent By jleahy Date 2018-01-30 Time 14:44 Rev Time 0.00
Received By jleahy Date 2018-01-30 Time 14:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-07-03 Cont ID  
Sent By jleahy Date 2017-07-03 Time 13:17 Rev Time 0.00
Received By jleahy Date 2017-07-03 Time 11:59 Sent To  
Notes
2017-07-03 13:17:21FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E-2-1
 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION
 FOR PERSONNEL (B) OTHER THAN DWELLING UNITS
  
 (8) GARAGES, SERVICE BAYS, AND SIMILAR AREAS
  
  
 PAGE E-3-1
 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION
 FOR PERSONNEL (B) OTHER THAN DWELLING UNITS
 ALL 125-VOLT, SINGLE-PHASE 15- AND 20-AMPERE
 RECEPTACLES
 INSTALLED IN THE LOCATIONS SPECIFIED IN 210.8(B)(1)
 THROUGH
 (8) SHALL HAVE GROUND-FAULT CIRCUITINTERRUPTER
 PROTECTION FOR PERSONNEL.
  
 (2) KITCHENS
  
  
 PAGE E-41
  
 RISER SHOWS 800A GENERATOR SET WITH 620A OF WIRE
  
 PAGE E-6-1
  
 LOAD CALCULATION SHOWS PERCENTAGES USED FOR LOAD CALC
 LIKE 110%, 121% ?
 HVAC LOAD OF 5.7 ? THERE IS OTHERS SHOWN HOW IS 5.7 THE
 LOAD FOR ACS?

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-02-14 Cont ID  
Sent By vperez Date 2017-02-14 Time 11:17 Rev Time 0.00
Received By vperez Date 2017-02-14 Time 11:17 Sent To  
Notes
2017-02-14 11:17:29APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE
 PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE
 PERMITS AND DATA SPECIFICATION SHEET SUBMITTALS FOR ALL
 LOW VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED TO FIRE
 ALARM, CCTV, PHONE AND DATA, WIRELESS SYSTEMS, CARD
 READERS, GENERATOR, KITCHEN HOODS ETC. A NOTE WILL
 SUFFICE.
 2. ADD A GENERAL NOTE TO PROVIDE PER FBC EC 405.7.4-
 COMPLETION DOCUMENTS PER CODE SECTION. FBC EC 405.7.3-
 VOLTAGE DROP
 3. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO
 INDICATE NEC 110.16. ARC FLASH WARNING SIGNS AND NEC
 110.24- AVAILABLE FAULT CURRENT- FIELD MARKINGS; SEE
 VERBIAGE IN CODE.
 4. PROVIDE THE AVAILABLE FAULT CURRENT AT THE UTILITY
 TRANSFORMER. FBC 107.3.5
 5. PER FBC EC 405.7- A MINIMUM OF 50% OF ALL 125V, 15
 AND 20AMP RECEPTACLES SHALL BE AUTOMATICALLY CONTROLLED
 WHERE INSTALLED IN PRIVATE OR OPEN OFFICES AND COMPUTER
 CLASSROOMS. THIS INCLUDES MODULAR PARTITIONS TOO. SHOW
 COMPLIANCE ACCORDINGLY.
 6. PROVIDE A NOTE TO INDICATE COMPLIANCE WITH FBC EC
 405.2 AUTOMATIC LIGHTING CONTROL AND LIGHTING DENSITIES
 PER CODE SECTION.
 7. PLEASE ADDRESS BUILDING, FIRE AND MECHANICAL
 COMMENTS RELATED TO ELECTRICAL.
 8. PROVIDE A NOTE ON PLANS TO INDICATE NEC 300.5
 REQUIREMENTS FOR ALL UNDERGROUND RACEWAYS.
 9. PROVIDE 1/2" DETAIL OF MAIN ELECTRICAL ROOM( WHERE
 MDP IS LOCATED) TO VERIFY CLEARANCE. FBC 107.3.5
 10. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLES IN THE
 BASEMENT AREA AND MAINTENANCE SECTION PER NEC 210.8B
 (6)INDOOR WET LOCATION (8) SIMILAR AREAS WHERE
 ELECTRICAL DIAGNOSTIC EQUIPMENT, ELECTRICAL HAND TOOLS
 ARE TO BE USED.- THAT WILL INCLUDE ALL 125V SINGLE
 PHASE 15 OR 20A RECEPTACLES.
 11. PLEASE NOTE THAT THE SEPARATE GENERATOR PERMIT
 REQUIRED WILL NEED TO PROVIDE A SELECTED LOAD
 ARRANGEMENT BASED ON CUSTOMER SELECTED LOADS. MANUAL
 TRANSFER SELECTED. NEC 702.4.B1. ALSO SIGNAGE IS TO BE
 PROVIDED PER NEC 702.7A. A NOTE WILL SUFFICE
 12. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL
 FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS
 REGARDING THIS PROJECT.
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2017-02-24 Cont ID  
Sent By skennedy Date 2017-02-24 Time 17:04 Rev Time 0.00
Received By skennedy Date 2017-02-24 Time 17:04 Sent To  
Notes
2017-02-24 17:13:18PER MGONZALES EMAIL OF 2/24/17 ENGINEERING REVIEW WILL
 BE DONE UNDER FORMAL ENGINEERING SUBMITTAL ONLY.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-06-14 Cont ID  
Sent By wjolin Date 2017-06-14 Time 09:45 Rev Time 0.00
Received By wjolin Date 2017-06-08 Time 09:28 Sent To  
Notes
2017-06-09 07:54:263200 NORTH CONGRESS AVENUE - CLUBHOUSE
 PERMIT #16110061
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 **PROVISO - REVISION NEEDED**
  
 REPEAT COMMENT - SHEET E-2.2: PER SECTION 12.3.4.3.3,
 PROVIDE SPEAKER/STROBE NOTIFICATION APPLIANCES AS
 ASSEMBLY OCCUPANCIES WITH AN OCCUPANT LOAD EXCEEDING
 300 OCCUPANTS SHALL RECEIVE FIRE ALARM NOTIFICATION BY
 VISIBLE SIGNALS AND VOICE ANNOUNCEMENTS. PROVIDE A
 PRE-RECORDED FIRE ALARM EVACUATION MESSAGE NOTIFYING
 OCCUPANTS AN EMERGENCY HAS BEEN REPORTED IN THE
 BUILDING, LOCATE THE NEAREST EXIT, AND EXIT THE
 BUILDING IMMEDIATELY. DO NOT USE THE ELEVATOR.
  
 REPEAT COMMENT - SHEET E-2.2: NO NOTIFICATION
 APPLIANCES PROVIDED IN ALL RESTROOMS, CHANGING ROOMS OR
 SHOWER SPACES.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-02-07 Cont ID  
Sent By wjolin Date 2017-02-07 Time 15:10 Rev Time 0.00
Received By wjolin Date 2017-02-07 Time 12:11 Sent To  
Notes
2017-02-07 13:30:083200 NORTH CONGRESS AVENUE - CLUBHOUSE
 PERMIT #16110061 & 17010998 (TWO DIFFERENT PERMITS FOR
 SAME STRUCTURE?)
 REVIEW COMMENTS - FIRE DEPARTMENT
  
  
 GENERAL: PER NFPA 241 SECTION 8.7.2.3, WHERE
 UNDERGROUND WATER MAINS AND HYDRANTS ARE TO BE
 PROVIDED, THEY SHALL BE INSTALLED, COMPLETED, AND IN
 SERVICE PRIOR TO VERTICAL CONSTRUCTION WORK OR
 ACCUMULATION OF COMBUSTIBLE MATERIALS. PER SECTION
 18.3.4.1 (NFPA 1), FIRE HYDRANTS SHALL BE PROVIDED WITH
 CLEARANCES OF 7'-6" TO THE FRONT AND SIDES AND 4'-0" TO
 THE BACKSIDE OF THE STEAMER CAP.
  
 GENERAL: A SUB PERMIT (UG FIRELINE) IS NEEDED TO
 INSTALL FIRE MAINS AND FIRE HYDRANTS.
  
 GENERAL: PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN
 TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE
 PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE
 PROVIDED AS REQUIRED BY THE AUTHORITY HAVING
 JURISDICTION.TEMPORARY CONSTRUCTION TRAILERS OR MODULAR
 BUILDINGS WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE
 FOLLOWING:
 PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION,
 ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2:
 TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF
 COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE
 CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS,
 TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1.
 PER TABLE 4.2.1:
 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 30 FEET
 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 35 FEET
 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 40 FEET
 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 45 FEET
 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 50 FEET
 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE
 SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET
 **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL
 BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC
 SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE.
  
 GENERAL: PROVIDE DRAWING NOTE INDICATING ALL
 CONSTRUCTION WORK SHALL CONFORM TO THE REQUIREMENTS OF
 NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE
 REMOVED FROM THE SITE DAILY. SMOKING SHALL BE
 PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL
 OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE
 RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED.
  
 GENERAL: PROVIDE AN EXTERIOR KEY SAFE TO ALLOW
 EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE
 BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE
 ORDERED FROM WWW.KNOXBOX.COM.
  
 GENERAL: STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R/F/RF
 DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA
 ADMINISTRATIVE CODE 69A-60.0081.
  
 CIVIL: SUBMIT OFFICIAL CIVIL DRAWINGS SHOWING ALL FIRE
 DEPARTMENT ACCESS ROADS, FIRE MAINS, AND FIRE HYDRANTS.
 CIVIL PLANS INDICATE FOR REFERENCE ONLY. MOST OF THE
 SAME CIVIL PLANS ARE SUBMITTED MULTIPLE TIMES; AND
 DRAWING SET IS NOT A COMPLETE CIVIL SET.
  
 SITE: PER SECTION 18.2.3.4.1.1 (NFPA 1), FIRE
 DEPARTMENT ACCESS ROADS SHALL HAVE A SURFACE DESIGNED
 TO ACCOMMODATE FIRE APPARATUS WEIGHING AT LEAST 38
 TONS. ACCESS ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF
 NOT LESS THAN 20 FEET AND AN UNOBSTRUCTED VERTICAL
 CLEARANCE OF NOT LESS THAN 13 FEET 6 INCHES.
  
 SITE: PER SECTION 18.2.3.5.3 (NFPA 1), FIRE LANES SHALL
 BE MARKED WITH FREESTANDING SIGNS READING, "FIRE LANE -
 NO PARKING BY ORDER OF THE FIRE DEPARTMENT." SIGNS
 SHALL BE 12" X 18" WITH A WHITE BACKGROUND AND RED
 LETTERS AND SHALL BE A MAXIMUM OF SEVEN FEET IN HEIGHT
 TO THE BOTTOM OF THE SIGN. SIGNS SHALL BE WITHIN SIGHT
 OF THE TRAFFIC FLOW AND BE SPACED A MAXIMUM OF 60 FEET
 APART.
  
 CIVIL: PER NFPA 1 SECTION18.2.3.2.1 A FIRE DEPARTMENT
 ACCESS ROAD SHALL EXTEND TO WITHIN 50 FEET OF AT LEAST
 ONE EXTERIOR DOOR THAT CAN BE OPENED FROM THE OUTSIDE
 AND THAT PROVIDES ACCESS TO THE INTERIOR OF THE
 BUILDING. THE CURRENT DRIVE AISLE NEAR THE CLUBHOUSE IS
 NOT AN APPROVED FIRE LANE BECAUSE IT DOES NOT HAVE A
 MINIMUM CLEAR WIDTH OF 20 FEET AND CANNOT RELIABLY
 REMAIN UNOBSTRUCTED FROM GOLF CARTS, VEHICLES, ETC AT
 ALL TIMES AS IS SHOWN IN SHEET A204.ADDITIONALLY THE
 PORTE COCHIERE MAY IMPEDE FIRE RESCUE OPERATIONS.
  
 CIVIL: COULD NOT LOCATE A FIRE HYDRANT NEAR THE
 CLUBHOUSE.
  
 SHEET A003: BASEMENT STAIR AND KITCHEN OCCUPANTS
 INDICATE AN EXIT DISCHARGE THROUGH THE DELIVERY AND
 DUMPSTER AREA.
  
 SHEET A003: EGRESS DOOR NEAR THE ADA RAMP IS OBSTRUCTED
 BY TABLE AND CHAIRS.
  
 GENERAL: PROVIDE A KITCHEN EQUIPMENT SCHEDULE.
  
 GENERAL: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT
 DOORS WITH EXIT SIGNS.
  
 GENERAL: FOR ASSEMBLY OCCUPANCIES WITH AN OCCUPANT LOAD
 OF 100 OR MORE PERSONS (50 PERSONS PER THE FLORIDA
 BUILDING CODE), PANIC HARDWARE SHALL BE PROVIDED ON
 DOORS TO RELEASE THE LOCK/LATCH. NO OTHER LOCKS OR
 LATCHES ARE PERMITTED THAT WOULD NOT BE RELEASED BY THE
 PANIC HARDWARE. AS A SUBSTITUTE FOR PANIC HARDWARE, THE
 MAIN ENTRANCE (ONLY) IS PERMITTED TO HAVE AN INTERIOR
 KEYED DOOR LOCK (AND NO LATCH) WITH A READILY VISIBLE
 SIGN STATING THIS DOOR TO REMAIN UNLOCKED WHEN THE
 BUILDING IS OCCUPIED. SIGN LETTERS SHALL BE AT LEAST 1
 INCH IN HEIGHT. KEYED LOCK TO BE EQUIPPED WITH AN
 "OPEN/LOCKED" INDICATOR WINDOW (SUCH AS ADAMS RITE 4089
 OR SIMILAR). A THUMB TURN STYLE LOCK IS NOT PERMITTED
 TO BE SUBSTITUTED FOR A KEYED LOCK.SHEET
 A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED
 AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON
 THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED DURING PLAN RESUBMISSION.
  
 SHEET FP-1.1: THE ENTIRE BASEMENT IS STORAGE; PROTECT
 ENTIRE SPACE AS ORDINARY HAZARD.
  
 SHEET FP-1.2: PROTECT MERCANTILE PRO SHOP #113 AS
 ORDINARY HAZARD.
  
 SHEET E-1.2: DOES NOT APPEAR TO BE ANY EXTERIOR
 EMERGENCY LIGHTING ON EAST SIDE OF BUILDING AND ADA
 RAMP AREA.
  
 SHEET E-2.2: PER SECTION 12.3.4.3.3, PROVIDE
 SPEAKER/STROBE NOTIFICATION APPLIANCES AS ASSEMBLY
 OCCUPANCIES WITH AN OCCUPANT LOAD EXCEEDING 300
 OCCUPANTS SHALL RECEIVE FIRE ALARM NOTIFICATION BY
 VISIBLE SIGNALS AND VOICE ANNOUNCEMENTS. PROVIDE A
 PRE-RECORDED FIRE ALARM EVACUATION MESSAGE NOTIFYING
 OCCUPANTS AN EMERGENCY HAS BEEN REPORTED IN THE
 BUILDING, LOCATE THE NEAREST EXIT, AND EXIT THE
 BUILDING IMMEDIATELY. DO NOT USE THE ELEVATOR.
  
 SHEET E-2.2: NO NOTIFICATION APPLIANCES PROVIDED IN ALL
 RESTROOMS, CHANGING ROOMS OR SHOWER SPACES.
  
 SHEET M-1.2 & M-1.3: KITCHEN EXHAUST FANS ARE
 TERMINATING AT AN OUTSIDE WALL IN LIEU OF ROOFTOP
 TERMINATION. THE FANS ARE LOCATED WITHIN 10 FEET OF THE
 COMBUSTIBLE ROOF WHICH IS NOT PERMITTED BY NFPA 96
 SECTION 7.8.3.
  
 NOTE: REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE
 THE OWNER, CONTRACTOR, ETC. OF THE RESPONSIBILITY OF
 COMPLIANCE WITH CODE (NFPA 1, SECTION 1.14.4).FBC
 SECTION 105.4.1 PERMIT INTENT: A PERMIT ISSUED SHALL BE
 CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND
 NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE
 ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL
 ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM
 THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS,
 CONSTRUCTION OR VIOLATIONS OF THIS CODE.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 4 Status P Date 2018-04-07 Cont ID  
Sent By gjohnson Date 2018-04-07 Time 10:56 Rev Time 0.00
Received By gjohnson Date 2018-04-07 Time 10:56 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2018-02-07 Cont ID  
Sent By gjohnson Date 2018-02-07 Time 07:35 Rev Time 0.00
Received By gjohnson Date 2018-02-07 Time 07:35 Sent To  
Notes
2018-02-07 07:37:343RD REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 GAS COMMENTS:
  
 PREVIOUS COMMENT NOT COMPLIED 3RD REQUEST SUBMIT
 CALCULATIONS FOR COMBUSTION AIR PER THE FBC-2014 FUEL
 GAS CODE SEC. 304. THE WATER HEATERS ARE THE ONLY
 DIRECT VENT GAS APPLIANCES PLEASE PROVIDE COMBUSTION
 CALC FOR KITCHEN COOKING APPLIANCES.
  
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2017-07-07 Cont ID  
Sent By gjohnson Date 2017-07-07 Time 10:53 Rev Time 0.00
Received By gjohnson Date 2017-07-07 Time 10:53 Sent To  
Notes
2017-07-07 11:09:441ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 GAS COMMENTS:
  
 PREVIOUS COMMENT NOT COMPLIED 2ND REQUEST5. SUBMIT
 CALCULATIONS FOR COMBUSTION AIR PER THE FBC-2014 FUEL
 GAS CODE SEC. 304. THE WATER HEATERS ARE THE ONLY
 DIRECT VENT GAS APPLIANCES PLEASE PROVIDE COMBUSTION
 CALC FOR KITCHEN COOKING APPLIANCES.
  
 NEW COMMENTS:
  
 1. THE NOTE ON THE GAS RISER 11/2" G(GWH-2/399) IS THIS
 INDICATING 2 GWH AT 399 CFH THE PLAN ONLY SHOWS ONE
 PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 2. SHOW ALL PIPING FOR GWH ON RISER WITH SIZE AND
 LENGTH. PER WPB AMEND TO FBC 107.2.1
  
 3. PLEASE SHOW METER ON RISER. PER WPB AMEND TO FBC
 107.2.1
  
 4. SHOW ANSUL VALVE ON RISER. PER WPB AMEND TO FBC
 107.2.1
  
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2017-03-01 Cont ID  
Sent By gjohnson Date 2017-03-01 Time 16:43 Rev Time 0.00
Received By gjohnson Date 2017-03-01 Time 16:43 Sent To  
Notes
2017-03-01 16:49:321ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 GAS COMMENTS:
  
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL
 CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER
 FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2.
  
 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. TYPE OF GAS, (LP OR NATURAL).
  
 4. SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE
 SEC. 402.4.1.
  
 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2014 FUEL GAS CODE SEC. 304.
  
 6. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014
 FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2
 PSI.
  
 7. PROVIDE SIZING TABLE BEING USED TO SIZE SYSTEM. WPB
 AMENDMENTS TO FBC SEC. 107.2.1
  
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2018-04-17 Cont ID  
Sent By lmarchan Date 2018-04-17 Time 14:23 Rev Time 0.00
Received By lmarchan Date 2018-03-13 Time 10:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2018-02-09 Time   Rev Time 0.00
Received By cpuell Date 2018-01-10 Time 10:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-09-07 Cont ID  
Sent By cpuell Date 2017-09-07 Time 12:58 Rev Time 0.00
Received By cpuell Date 2017-06-06 Time 16:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-05-02 Cont ID  
Sent By lmarchan Date 2017-05-02 Time 10:57 Rev Time 0.00
Received By lmarchan Date 2017-04-28 Time 10:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-04-04 Cont ID  
Sent By lmarchan Date 2017-04-04 Time 07:45 Rev Time 0.00
Received By lmarchan Date 2017-01-26 Time 16:29 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-06-26 Cont ID  
Sent By shill Date 2017-06-26 Time 15:36 Rev Time 0.00
Received By shill Date 2017-06-26 Time 15:36 Sent To  
Notes
2017-06-26 15:36:34MU-2017-9292
 EUC, $0 DUE
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-02-16 Cont ID  
Sent By shill Date 2017-02-16 Time 13:08 Rev Time 0.00
Received By shill Date 2017-02-16 Time 13:08 Sent To  
Notes
2017-02-16 13:08:55IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED
  
 THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING
 THAT FEES WERE PAID ARE TO BE SUBMITTED PRIOR TO PERMIT
 ISSUANCE
  
 561-233-5025 FOR MORE INFORMATION
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2018-04-05 Cont ID  
Sent By ccole Date 2018-04-05 Time 16:30 Rev Time 0.00
Received By ccole Date 2018-04-05 Time 07:43 Sent To  
Notes
2018-04-05 16:50:35MECHANICAL PROVISO.
 4/5/18
  
 REQUIRED SUBMITTALS:
  
 1) WIND LOAD ENGINEERING FOR INSTALLATION OF ALL
 EXTERIOR MECHANICAL EQUIPMENT INCLUDING AC CONDENSERS
 AND FANS.
  
 2) FLORIDA PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S
 FOR CONDENSER ANCHORING CLIPS, EXHAUST AND OUTDOOR AIR
 LOUVERS.
  
 3) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION
 INSTRUCTIONS FOR THE GARAGE EXHAUST FANS, THE HONEYWELL
 GAS MONITORS AND CONTROLLER, THE EXHAUST DUCT
 FIREWRAPPING, FIRE DAMPERS, AND SMOKE DETECTORS.
  
 ALL SUBMITTALS SHALL BE REVIEWED AND APPROVED BY THE
 DESIGN PROFESSIONAL OF RECORD AND BEAR SHOP DRAWING
 APPROVAL STAMPS.
  
 1) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS.
 FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS
 ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE
 NOT SUBMITTED AT THE TIME OF THEAPPLICATION AND THAT
 ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
 2) DEFERRED SUBMITTAL. 2017 FBC 107.3.4.1 PRODUCT
 APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE
 DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2018-02-09 Cont ID  
Sent By ccole Date 2018-02-09 Time 13:48 Rev Time 0.00
Received By ccole Date 2018-01-30 Time 11:58 Sent To I
Notes
2018-02-09 14:01:563RD REVIEW FBC-2014 MECHANICAL , ENERGY CONSERVATION
 CODES.
 WEST PALM BEACH AMENDMENTS TO THE FBC.
 PERMIT #16110061
 7/7/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE VENTILATION SYSTEM IN THE GOLF CART PARKING
 GARAGE WHERE THE BATTERIES ARE CHARGED IS STILL IN
 QUESTION. THE SUBMITTAL FROM CLUB CAR AND THE REVISED
 PLAN ARE NOT CLEARLY INDICATING THAT THE SYSTEM WILL
 PROVIDE CONTINUOUS VENTILATION THAT WILL LIMIT THE
 CONCENTRATION OF HYDROGEN TO 1.0 PERCENT OF THE VOLUME
 OF THE ROOM- SECTION 502.4.1. PROVIDE FURTHER EVIDENCE
 AND CALCULATIONS
  
 ACCORDINGLY. PLEASE NOTE THAT THE SENSORS SHALL ALSO BE
 CAPABLE OF DETECTING NO2 IN CONJUNCTION WITH CO2 PER
 SECTION 404.1 (2).
  
 2) REFER TO SECTIONS 510.6.1 & 510.6.2: THE FIRE
 DAMPERS IN THE GARAGE EXHAUST DUCTS ARE PROHIBITED, AND
 THE DUCTS SHALL BE ENCLOSED IN FIRE-RESISTANT SHAFT
 CONSTRUCTION WHERE THEY PENETRATE THE FLOOR/CEILING
 SASSEMBLY, ASCEND UP THROUGH THE 1ST FLOOR AND ATTIC
 SPACE TO TERMINATION ABOVE THE ROOF.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-07-07 Cont ID  
Sent By ccole Date 2017-07-07 Time 10:18 Rev Time 0.00
Received By ccole Date 2017-07-06 Time 12:38 Sent To  
Notes
2017-07-07 11:30:412ND REVIEW FBC-2014 MECHANICAL , ENERGY CONSERVATION
 CODES.
 WEST PALM BEACH AMENDMENTS TO THE FBC.
 PERMIT #16110061
 7/7/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS M0.1 & M1.1: REFER TO COMMENT #3 FROM THE 1ST
 REVIEW AND SECTION 404.2 MINIMUM VENTILATION FOR
 PARKING GARAGES. PLEASE PROVIDE EXHAUST CACULATIONS
 BASED ON A MINIMUM AIRFLOW RATE OF 0.05 CFMS PER SQ.
 FT. AND A MAXIMUM CAPABILITY OF 0.75 CFMS PER SQ. FT.
 PLACE A NOTE THAT THE SYSTEM WILL OPERATE CONTINUOUSLY
 NOT BELOW THE MINIMUM AIRFLOW RATE.
  
 2) M1.1, DETAIL 2: PLEASE PROVIDE A WRITTEN NARRATIVE
 TO ACCOMPANY AND CLARIFY THE GAS MONITORING CONTROL
 SEQUENCE OF OPERATION.
  
 3) M1.1: REFER TO COMMENT #9 FROM THE 1ST REVIEW AND
 SECTIONS 502.4 & 502.8. AS PREVIOUSLY REQUESTED
 INDICATE WHERE THE GOLF CART BATTERIES WILL BE STORED
 AND CHARGED AND PROVIDE CONTINOUS VENTILATION THAT WILL
 LIMIT THE CONCENTRATION OF HYDROGEN TO 1.0 PERCENT OF
 THE TOTAL VOLUME OF THE ROOM- SECTION 502.4.1. A) THE
 SUBMITTED DOCUMENT FROM "CLUB CAR" APPEARS TO BE JUST
 ONE PAGE OF A MULTI-PAGE DOCUMENT. PLEASE PROVIDE A
 COMPLETE SUBMITTAL WITH A REVIEW AND APPROVAL STAMP BY
 THE ENGINEER OF RECORD. B) THE FLOOR PLAN SHOWS ONLY
 TWO GAS SENSORS FOR THE ENTIRE AREA: PROVIDE
 MANUFACTURER'S SPECIFICATIONS TO VERIFY THE SPACINGS
 ARE ADEQUATE, AND NOTE THAT A SENSOR WILL BE REQUIRED
 IN THE BATTERY STORAGE ROOM. C) PLEASE PLACE A NOTE ON
 THE PLANS PURSUANT TO TABLE 403.3 FOOTNOTE B THAT NO
 EXHAUST AIR FROM THE PARKING GARAGE WILL BE
 RECIRCULATED TO OCCUPIED SPACES VIA AHU-1.
  
 4) M1.1, M1.2, & M2.1- DETAIL 12: PROVIDE DUCT SMOKE
 DETECTORS IN THE RETURN AIR SYSTEMS OF AHU'S 1, 2, & 3-
 SECTION 606.2.1. PROVIDE SYMBOLS TO SHOW THE
 INSTALLATION LOCATIONS.
  
 5) M1.2 & M1.3 & M1.3: NO REFERENCE TO THE MUA FAN(S)
 FOR THE HOODS ARE SHOWN ON THE MECHANICAL FLOOR PLANS
 AND NO EQUIPMENT SCHEDULES HAVE BEEN PROVIDED, OR FAN
 LOCATIONS SHOWN.
  
 6) M1.2: THE 2X2' ACCESS PANEL FOR AHU-2 APPEARS TWO
 SMALL TO BE ABLE TO REMOVE AND REPLACE AHU-2, AND NO
 PANEL LOCATIONS ARE SHOWN FOR VAV BOXES AND FANS THAT
 ARE LOCATED ABOVE HARD CEILINGS- PLEASE SEE CODED NOTE
 #1 ON THE PLAN, AND SECTION 306.1 AND SHOW ALL PROPOSED
 PANEL LOCATIONS AND DIMENSIONS.
  
 7) M1.1: PROVIDE THE CLEARANCE DISTANCE MEASUREMENT
 BETWEEN EXHAUST FANS EF-3A & 3B AND THE 24X12 O/A
 LOUVER. THE LOCATIONS DO NOT APPEAR TO BE IN COMPLIANCE
 WITH EITHER 401.4 OR 506.3.13.3.
  
 8) M2.1 : PROVIDE THE WIND DESIGN CRITERIA USED TO
 ESTABLISH THE TIE DOWN DESIGN FOR THE CONDENSERS, AND
 SUBMIT A FL. PRODUCT APPROVAL OR MIAMI-DADE NOA FOR THE
 CLIP. PLEASE NOTE ALL SUBMITTALS SHALL BEAR THE SHOP
 DRAWING APPROVAL STAMP FROM THE EOR.
  
 9) PLEASE PROVIDE A MECHANICAL ROOF PLAN SHOWING THE
 LOCATIONS OF OF EQUIPMENT, AND ALL MECHANICAL OR
 GRAVITY O/A INTAKE OPENINGS AND EXHAUST OUTLETS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-02-03 Cont ID  
Sent By ccole Date 2017-02-03 Time 09:58 Rev Time 0.00
Received By ccole Date 2017-02-03 Time 09:58 Sent To  
Notes
2017-02-03 10:35:571ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16110061
 2/3/17
  
 1) THE SUMMARY AC COOLING AND HEATING CALCULATIONS
 SHALL BEAR AN ELECTRONIC SIGNATURE AND SEAL BY THE
 ENGINEER OF RECORD- SECTION C403.2.1 EXCEPTION FBC-14
 ENERGY CONSERVATION, AND SECTION 61G15-23.005 FLORIDA
 ADMINISTRATIVE CODE.
  
 2) THE ENERGYGAUGE COMPLIANCE SUBMITTAL MUST BEAR THE
 CERTIFICATION SIGNATURES OF THE DESIGN PROFESSIONALS
 AND THE OWNER/AGENT ON PAGE 3, AND MUST BE
 ELECTRONICALLY SIGNED AND SEALED PER SECTION
 61G15-23.005 FAC.
  
 3) PROVIDE EXHAUST VENTILATION CALULATIONS FOR THE
 PARKING GARAGE, THE LOCKER ROOMS AND BATHROOMS, AND THE
 KITCHEN PER TABLE 403.3. A) INDICATE HOW MAKEUP AIR IS
 BEING PROVIDED FOR THE GARAGE AND LOCKER ROOM EXHAUST
 SYSTEMS. B) PROVIDE AIR BALANCE CALCULATIONS FOR BOTH
 FLOORS THAT INCLUDE ALL EXHAUST SYSTEMS.
  
 4) ADVISORY: SEPARATE PERMITS AND PLANS ARE REQUIRED
 FOR THE KITCHEN EXHAUST SYSTEM, THE KITCHEN HOOD FIRE
 SUPPRESSION, AND THE WALK-IN COOLER/FREEZER. PLEASE
 PLACE A NOTE ON THE PLANS ACCORDINGLY. PLEASE NOTE THE
 FOLLOWING: A) THE HOOD EXHAUST FAN OUTLETS TERMINATING
 AT THE EXTERIOR WALL SHALL BE IN COMPLIANCE WITH
 506.3.13.2. B) THE FANS MUST BE ANCHORED TO THE
 BUILDING TO WITHSTAND THE DESIGN WINDLOADS AND
 PRESSURES, AND INSTALLED IN A MANNER TO PREVENT WATER
 INTRUSION.
  
 5) THE AC EQUIPMENT SCHEDULE ON M-3.1 INDICATES THAT AN
 ERV IS REQUIRED FOR AHU-1: REFER TO TABLE C403.2.6 AND
 SECTION C403.2.6 FBC-14 ENERGY CONSERVATION.
  
 6) M-3.1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE VAV
 BOXES.
  
 7) M-3.1: PROVIDE CONTROL SEQUENCES FOR ALL EXHAUST
 SYSTEMS.
  
 8) M-1.1: LABEL THE AIR HANDLER, IDENTIFY AND LABEL THE
 SUPPLY DIFFUSERS AND RETURN GRILLS.
  
 9) M-1.1: PROVIDE VENTILATION FOR THE BAG STORAGE,
 STORAGE, AND MAINTENANCE ROOMS- TABLE 403.3. PLEASE SEE
 SECTION 502 AND ALL APPLICABLE SUB-SECTIONS AND PROVIDE
 EXHAUST VENTILATION WHERE REQUIRED FOR ALL FUEL, OR
 BATTERY STORAGE ROOMS OR AREAS. PLEASE NOTE THAT A
 DETAILED LIST OF ALL HAZARDOUS MATERIALS AND THEIR
 QUANTITIES MAY BE REQUIRED PER SECTION414.1.3 FBC-14
 BUILDING.
  
 10) M-1.1 & M-1.2: FIRE DAMPERS ARE REQUIRED WHERE THE
 32X20, 22X14, AND 3" DUCTS PENETRATE THE FLOOR/CEILING
 ASSEMBLY- SECTION 607.6.2.
  
 11) M-1.1 & M-1.2: THE PLANS ARE INDICATING AIR FROM
 THE GROUND FLOOR GARAGE WILL BE RECIRCULATED INTO THE
 OCCUPIED AREAS ON THE FIRST FLOOR WHICH IS PROHIBITED
 BY FOOTNOTE B, TABLE 403.3.
  
 12) M-1.1: PROVIDE THE EXHAUST OUTLET CLEARANCE
 DISTANCES AS OUTLINED IN SECTION 501.3.1.
  
 13) M.1-1: CORRECT THE DUCT HEIGHT NOTE TO INDICATE
 MINIMUM 7'0" CLEARANCE FROM FINISHED GARAGE FLOOR TO
 BOTTOM OF THE DUCT- SECTION 406.4.1 FBC-14 BUILDING.
  
 14) M-1.2: THE PLAN DOES NOT APPEAR TO SHOW ANY EXHAUST
 VENTILATION FOR THE MEN'S AND WOMEN'S LOCKER ROOMS
 WHICH IS REQUIRED BY TABLE 403.3. PLEASE SEE FOOTNOTE G
 AS IT APPEARS RECIRCULATION FROM THOSE AREAS IS
 EXCEEDING THE ALLOWABLE MAXIMUM.
  
 15) M-1.2: THE PLAN APPEARS TO SHOW TWO L4 DIFFUSERS IN
 THE RECEPTION ROOM CONNECTED TO TWO B RETURN GRILLS IN
 THE GOLF-PRO OFFICE.
  
 16) M-1.2: PROVIDE ALL FLEX DUCT SIZES.
  
 17) M-1.2: INDICATE HOW ACCESS WILL BE PROVIDED FOR
 MAINTENANCE AND REPLACEMENT OF AHU'S 2 & 3- SECTION
 306.1.
  
 18) M-1.2: PROVIDE ENGINEERED DETAILS FOR TIE DOWN OF
 THE AC CONDENSER UNITS- SECTION 301.15.
  
 19) SUBMIT TWO COPIES OF A VALID FL.PRODUCT APPROVAL
 AND/OR MIAMI-DADE NOA FOR THE LOUVERS- RULE 9N-B FAC.
  
 20) A COMPLETE REVIEW OF THE PROPOSED PROJECT CANNOT BE
 PERFORMED AT THIS TIME DUE TO A LACK OF INFORMATION. IN
 ORDER TO EXPEDITE THE SECOND REVIEW PLEASE PROVIDED A
 DETAILED NARRATIVE THAT ITEMIZES ALL CORRECTIONS MADE
 TO THE PLANS. PLEASE NOTE ADDITIONAL COMMENTS MAY
 FOLLOW THIS INITIAL REVIEW.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2018-04-07 Cont ID  
Sent By gjohnson Date 2018-04-07 Time 10:56 Rev Time 0.00
Received By gjohnson Date 2018-04-06 Time 17:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2018-02-07 Cont ID  
Sent By gjohnson Date 2018-02-07 Time 07:37 Rev Time 0.00
Received By gjohnson Date 2018-02-06 Time 16:07 Sent To  
Notes
2018-02-07 09:17:073RD REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. P-4.2 THE DETAIL FOR THE GREASE INTERCEPTOR
 SHALL MATCH THE CITY OF WEST PALM BEACH PUBLIC WORKS
 DEPT STANDARD DETAIL GS-7 FOR CONCRETE GREASE
 INTERCEPTORS.
  
 2. SHT. P-1.0 IS MISSING THE DIGITAL SIGNATURE
  
 3. SHTS. P-1-1, P-3-2, P-4-3 THE DOCUMENTS HAVE BEEN
 MODIFIED AFTER DIGITAL SIGNATURE WAS APPLIED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-07-07 Cont ID  
Sent By gjohnson Date 2017-07-07 Time 11:10 Rev Time 0.00
Received By gjohnson Date 2017-07-07 Time 08:35 Sent To  
Notes
2017-07-07 11:39:161ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT P.3.3 THE TRAP FOR THE MOP SINK IS SHOWN ON THE
 SANITARY LINE IT SHALL BE ON THE GREASE RISER PLEASE
 CLARIFY. PER FBC PL 1003.3.1
  
 2. WHAT DOES FBO STAND FOR ON THE FLOOR TROUGH AND
 MOPSINK LOCATED ON THE GREASE RISER. PER WPB AMEND TO
 FBC 107.2.1
  
 3. SHT. P.0.2 UNDER THR PLUMBING SPECIFICATIONS 1.02
 HAS THE WRONG CODE YEAR WE ARE UNDER THE 2014 5TH
 EDITION PLEAS CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 4. SHT P.3.1 WATER RISER PLEASE IDENTIFY HOT WATER
 RETURN PIPING. PER WPB AMEND TO FBC 107.2.1
  
 5. SHT. P.1.1 IS LABELED AS BASEMENT LEVEL BUT THE PLAN
 SHOWS THE MAIN FLOOR ALSO MAKES IT VERY DIFFICULT TO
 DISCERN THE PLUMBING THE DIFFERENT LEVELS PLEASE
 SEPARATE. PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-03-01 Cont ID  
Sent By gjohnson Date 2017-03-01 Time 16:43 Rev Time 0.00
Received By gjohnson Date 2017-03-01 Time 13:23 Sent To  
Notes
2017-03-01 16:42:481ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. SHT. P-3-3 PLEASE SEPARATE THE ISOMETRIC DRAWINGS ,
 THE BASEMENT FROM THE 1ST FLOOR AND THE GREASE ALL
 SEPARATE OR EXPANDED SO THAT THE DIFFERENT LAYERS ARE
 NOT ON TOP OF EACH OTHER. PER WPB AMEND TO FBC 107.2.1
  
 2. TRAP PRIMERS ARE REQUIRED ON ALL FLOOR DRAINS SHOW
 TRAP PRIMERS ON THE ISOMETRIC DRAWING OR PUT A NOTE ON
 THE PLAN. PER FBC PL 1002.4 AND WPB AMEND TO FBC
 107.2.1
  
 3. PROVIDE ISOMETRIC DRAWINGS FOR THE STORM SHOWING THE
 GRADE OF THE PIPE AND THE SQFT BEING DRAINED BY EACH
 DRAIN. WPB AMEND TO FBC 107.3.5.1.3(13)
  
 3. A DRAIN PAN IS REQUIRED FOR WATER HEATER NOT SHOWN
 ON DETAIL SHT P-4-3. PER FBC PL 504.7
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop P-GREASE GREASE INTERCEPTOR/TRAP REVIEW
Rev No 1 Status P Date 2018-04-07 Cont ID  
Sent By gjohnson Date 2018-04-07 Time 10:56 Rev Time 0.00
Received By gjohnson Date 2018-04-07 Time 10:56 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2017-07-05 Cont ID  
Sent By shill Date 2017-07-05 Time 06:14 Rev Time 0.00
Received By shill Date 2017-07-05 Time 06:14 Sent To  
Notes
2017-10-04 06:15:20A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF PRODUCT
 APPROVAL INDICATING THE ASSEMBLY PROPOSED AND
 ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE
 ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR
 TO ROOF WORK COMMENCEMENT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2017-03-10 Cont ID  
Sent By shill Date 2017-03-10 Time 15:06 Rev Time 0.00
Received By shill Date 2017-03-10 Time 15:06 Sent To  
Notes
2017-03-10 15:06:09ROOF AND OTHER PRODUCT APPROVALS NOT SUBMITTED
 SEE BUILDING COMMENTS
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2018-04-10 Cont ID  
Sent By shill Date 2018-04-10 Time 07:28 Rev Time 0.00
Received By shill Date 2018-04-10 Time 07:28 Sent To  
Notes
2018-04-10 07:29:12RECEIVED M-1-3 AND MK-4-1

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2018-04-07 Cont ID  
Sent By shill Date 2018-04-07 Time 14:05 Rev Time 0.00
Received By shill Date 2018-04-07 Time 14:05 Sent To  
Notes
2018-04-07 14:05:19SHEETS 085 M-1-3 AND 088 MK-4-1 HAVE UNSIGNED CHANGES
 AFTER THE LAST SIGNATURE. PLEASE SEND THESE TWO SHEETS
 PROPERLY SIGNED AND SEALED VIA EMAIL TO [email protected]
 WITH "16110061 SIGNATURE FILES" IN THE SUBJECT LINE.
  
 IF NEW SHEETS ARE UPLOADED TO PROJECTDOX, A NEW
 MECHANICAL REVIEW IS REQUIRED. THEREFORE, PLEASE
 RESOLVE WITH ME VIA EMAIL.
  
 561-805-6724 IF YOU WISH TO DISCUSS.
 SAMANTHA M. HILL
  
  
  
2018-04-07 11:02:454/6/18 DIG SIG ON PLUMB SHT OK/GPJ

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2018-02-05 Cont ID  
Sent By shill Date 2018-02-05 Time 10:14 Rev Time 0.00
Received By shill Date 2018-02-05 Time 10:03 Sent To  
Notes
2018-02-07 09:18:31SHT. P-1.0 IS MISSING THE DIGITAL SIGNATURE
 SHTS. P-1-1, P-3-2, P-4-3 THE DOCUMENTS HAVE BEEN
 MODIFIED AFTER DIGITAL SIGNATURE WAS APPLIED.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
2018-02-05 10:37:42SEE BUILDING REVIEW FOR COMMENTS REGARDING DIGITAL
 SIGNATURE ISSUES
 A NEW REVIEW IS REQUIRED FOR NEW SHEETS UPLOADED IN
 NEXT CYCLE
  
 DIGITAL SIGNATURES REVIEWED (S.HILL)
  
 A SHEETS - OK
 S SHEETS - F; SEE BUILDING REVIEW
 FP - OK
 MEP - OK
 CIVIL - PAPER ORIGINAL WAS PROVIDED
 SOILS REPORT - OK
 ENERGY CALCS - OK
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2017-07-02 Cont ID  
Sent By shill Date 2017-07-02 Time 06:15 Rev Time 0.00
Received By shill Date 2017-10-04 Time 06:15 Sent To  
Notes
2017-06-30 06:43:07SIGNATURE REVIEW TO BE DONE AFTER RESUBMITTAL
  
 6/30/17 SOILS REPORT OK (SH)
 CIVIL SHEETS OK - ORIGINALS ON FILE WITH STRUCTURE
 PERMIT 17010998
 HOLLOW CORE DELEGATED ENGINEERING NOT SIGNED AND SEALED
 (SEE BUILDING REVIEW)
  
  
  
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2017-03-09 Cont ID  
Sent By shill Date 2017-03-09 Time 17:41 Rev Time 0.00
Received By shill Date 2017-03-09 Time 17:41 Sent To  
Notes
2017-02-16 13:11:43SEE BUILDING REVIEW FOR COMMENTS REGARDING DIGITAL
 SIGNATURE ISSUES
  
  
 DIGITAL SIGNATURES REVIEWED (S.HILL)
  
 A SHEETS - FAIL, SEE BUILDING COMMENTS
 SOILS REPORT - OK
 ENERGY CALCS - OK
 S SHEETS - SHEETS MUST BE DIGITALLY SIGNED AND SEALED;
 ENGINEER MAY NOT SIGN THE PLAN AS THIS METHOD DOES NOT
 COMPLY WITH FAC61G15. CONTACT ME OR FBPE TO DISCUSS
 JAMES MULLEN PE PROVIDED CERTIFICATE FOR FBC COURSE,
 EMAILED FBPE TO REQUEST THAT WEBSITE BE UPDATED
 CIVIL PAGES NOT SIGNED AND SEALED; FAILED, SEE BUILDING
 COMMENTS
  
  
  
2016-11-16 14:05:1011/16/16 - CIVIL DRAWINGS WILL BE FOR REFERENCE ONLY -
 DOES NOT NEED DIGITAL SIGNATURE. LEM

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 2 Status N Date 2018-02-05 Cont ID  
Sent By shill Date 2018-02-05 Time 10:03 Rev Time 0.00
Received By shill Date 2018-02-05 Time 10:03 Sent To  
Notes
***NONE***

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status F Date 2017-03-09 Cont ID  
Sent By shill Date 2017-03-09 Time 12:29 Rev Time 0.00
Received By shill Date 2017-03-09 Time 12:29 Sent To  
Notes
2017-03-09 12:35:20****CORRECTIONS****
 REVISED 3/21/17
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 3/21/17 - PER KEN CONRAD, IF THIS BUILDING IS NOT
 CLASSIFIED AS A THRESHOLD BUILDING, A RESIDENT
 INSPECTOR IS NOT REQUIRED. A PRE-CONSTRUCTION MEETING
 IS REQUIRED. A RESIDENT INSPECTOR IS SUGGESTED IF
 APPLICANT HAS A TIGHT CONSTRUCTION SCHEDULE, BUT NOT
 REQUIRED.
  
 *****************************************************
 IT IS NOT CLEAR WHETHER THIS IS A THRESHOLD BUILDING
 (SEE BUILDING COMMENTS REGARDING OCCUPANT LOAD), AND
 REQUIRES A SPECIAL INSPECTOR, OR, IF IT IS NOT A
 THRESHOLD BUILDING MAY REQUIRE A RESIDENT INSPECTOR,
 FBC 110.3.7, 110.3.9.
  
 THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD
 BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN
 (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN
 ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN THE
 FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
 A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING
 AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
  
 B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S
 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS
 REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS
 ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH
 INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND
 REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE
 PLACE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL
 INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER
 INFORMATION BEFORE THE PERMIT MAY BE ISSUED.
  
 C) THRESHOLD BLDG., REQUIRED STATEMENT: W.P.B.
 AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH
 ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT
 OR ENGINEER OF RECORD CONTAIN THE STATEMENT REQUIRED BY
 FLORIDA STATUTE 553.79. THE ARCHITECT'S PLAN INCLUDES
 THE STATEMENT ON PAGE A001; ENGINEER'S PLAN NEEDS
 STATEMENT TO BE ADDED (OR ADVISE WHERE THIS CAN BE
 LOCATED).
  
 D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME'
 OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE
 RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS
 SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE
 WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED,
 AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
  
 E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY
 FOR THIS TYPE OF CONSTRUCTION.
  
 F) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE
 REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE,
 PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING
 ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE
 APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR
 PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN
 COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR
 THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE
 IN BLACK & WHITE.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD
 BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS
 CONCERNING SPECIAL INSPECTORS.
  
 G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES,
 PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT
 AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING
 INSTALLATION SHALL BE SUPERVISED, INSPECTED AND
 CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING
 DOCUMENTS BY THE CONTRACTOR.
  
 H) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED
 TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL
 BUILDING INSPECTIONS FOR AUDITING OF JOBSITE
 INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6
 MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY.
  
 I) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES
 FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER
 HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE
 MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR
 WALLS AND CEILINGS.
  
 SI AGREEMENT/RESIDENT INSPECTOR AGREEMENT, G&P FOR
 SPECIAL INSPECTORS SENT VIA EMAIL TO
 [email protected] ON 3/9/17.
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2018-04-17 Cont ID  
Sent By jroach Date 2018-04-17 Time 14:11 Rev Time 0.00
Received By jroach Date 2018-04-17 Time 14:00 Sent To  
Notes
2018-04-17 14:11:45ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 04.17.2018
 PERMIT NO.: 16110061
 ___________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ___________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. PRIOR TO THE ISSUANCE OF A CO, ALL SITE
 IMPROVEMENTS, LANDSCAPING, PARKING, ETC. FOR PHASE I
 SHALL BE COMPLETED.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 2 Status P Date 2017-09-07 Cont ID  
Sent By jroach Date 2017-09-07 Time 11:48 Rev Time 0.00
Received By jroach Date 2017-09-07 Time 11:48 Sent To  
Notes
2017-09-07 11:53:05ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 09.07.2017
 PERMIT NO.: 16110061
 ___________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ___________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. PRIOR TO THE ISSUANCE OF A CO, ALL SITE
 IMPROVEMENTS, LANDSCAPING, PARKING, ETC. FOR PHASE I
 SHALL BE COMPLETED.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2017-04-03 Cont ID  
Sent By jroach Date 2017-04-03 Time 16:06 Rev Time 0.00
Received By jroach Date 2017-04-03 Time 16:06 Sent To  
Notes
2017-04-03 16:07:28REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PLANS DO NOT MATCH THAT WHICH HAS BEEN APPROVED
 THROUGH THE BANYAN CAY PLANNED DEVELOPMENT. AMENDMENT
 SHALL BE SUBMITTED TO AND APPROVED BY THE PLANNING
 DIVISION PRIOR TO THE ISSUANCE OF A BUILDING PERMIT.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  