Plan Review Details - Permit 16110061
Plan Review Stops For Permit 16110061 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2017-06-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-06-30 |
Time |
06:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-06-30 |
Time |
06:40 |
Sent To |
|
|
Notes |
2017-06-30 06:41:06 | NEW PROPOSED ADDRESS: 1900 BANYAN CLUB RD |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2017-02-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-02-16 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-02-16 |
Time |
14:13 |
Sent To |
|
|
Notes |
2017-02-16 14:16:21 | PLEASE SEND A COPY OF THE PROPOSED PLAT, SITE PLAN, | | INCLUDING PROPOSED STREET NAMES AND PROPOSED ADDRESSES, | | TO: | | | | MICHAEL ORIO | | [email protected] | | 561-494-1080 | | | | |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
F |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
scwelter |
Date |
2022-08-15 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
scwelter |
Date |
2022-08-15 |
Time |
16:49 |
Sent To |
|
|
Notes |
2022-08-15 16:48:55 | SUBJECT TO PUBLIC ART REQUIREMENT. CONTACT | | [email protected] | | | | ART ASSESSMENT APPLICATION NEEDS TO BE COMPLETED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-07 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-07 |
Time |
13:16 |
Sent To |
|
|
Notes |
2018-04-07 13:52:41 | ****PROVISOS**** | | REVISED 4/13/18 | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | A. PRODUCT APPROVALS ARE DEFERRED SUBMITTALS. ALL | | PRODUCT APPROVALS, DELEGATED ENGINEERING, AND OTHER | | SUBMITTALS REQUIRED BY THE INSPECTOR ARE TO BE | | SUBMITTED AND REVIEWED BY OUR DEPARTMENT PRIOR TO | | INSTALLATION. ALL SUBMITTALS ARE TO BE REVIEWED BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL TO THE BUILDING | | DIVISION, FBC B 1609. | | | | B. A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF PRODUCT | | APPROVAL INDICATING THE ASSEMBLY PROPOSED AND | | ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE | | ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR | | TO ROOF WORK COMMENCEMENT. | | | | C. MOVEABLE (NONFIXED) SEATING WAS NOT REVIEWED. | | | | D. REPLAT REQUIRED PRIOR TO CO. A COPY OF THE RECORDED | | REPLAT IS TO BE PROVIDED VIA EMAIL. | | | | E. RESTRICTIVE COVENANT REQUIRED PRIOR TO C.O. A COPY | | OF THE RECORDED DOCUMENT IS TO BE PROVIDED VIA EMAIL. | | (RECEIVED ON 4/13/18) | | | | F. SEPARATE PERMITS ARE REQUIRED; ONLY BUILDING, | | MECHANICAL, ELECTRICAL, PLUMBING ARE INCLUDED IN THIS | | REVIEW. SEPARATE PERMITS, FEES AND PLANS ARE REQUIRED | | FOR FIRE ALARM, FIRE SPRINKLER, FIRE UNDERGROUND LINE, | | PARKING LOT, GAS, LOW VOLTAGE, LANDSCAPING, AND OTHER | | SUCH ITEMS. | | | | G. THIS PROJECT HAS A SEPARATE ENGINEERING PERMIT; | | THERE MAY BE CONFLICTS BETWEEN THESE CIVIL SHEETS AND | | THE ISSUED ENGINEERING PERMIT. ISSUED AT CONTRACTOR'S | | RISK. APPLICANT IS TO REVISE ANY SHIEETS WHICH AFFECT | | BUILDING OR FIRE CODE COMPLIANCE. | | | | H. DIGITAL SIGNATURE FOR HOLLOWCORE SHOP DRAWINGS IS | | NOT ACCEPTABLE TO FBPE . PLEASE PROVIDE A PAPER SIGNED | | AND SEALED ORIGINAL TO ADDRESS. THIS MUST BE DONE PRIOR | | TO INSTALLATION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-02-05 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-02-05 |
Time |
06:10 |
Sent To |
|
|
Notes |
2018-02-05 08:55:19 | ****CORRECTIONS**** | | REVISED 2/21/18 | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. SEE COMMENTS FROM PREVIOUS LISTS, ITEM #16: REVISE | | PLAN TO SHOW COMPLIANCE WITH FBC B 705, TABLES 602, | | 705.8. | | | | 3RD REVIEW, SHEET A004 WAS PRELIMINARILY REVIEWED AND | | AGREED UPON IN A MEETING - A RESTRICTIVE COVENANT IS TO | | BE FILED TO LIMIT CONSTRUCTION ON THE ADJACENT LOT. | | | | PLEASE PROVIDE TIMELINE FOR THE RECORDING OF THE | | RESTRICTIVE COVENANT AND THE REPLAT. SEE ALSO NEW | | COMMENT #2. | | | | 2. A004 DOES NOT MATCH A005 AND OTHER SHEETS. SHEET | | A005 AND OTHER PAGES (SUCH AS A201) DEPICT THE CORNER | | OF THE ROOF OVERHANG EXTENDING OVER THE ADJACENT | | PROPERTY. ALTHOUGH A RESTRICTIVE COVENANT ADDRESSING | | THE PROPOSED NONCOMPLIANT CONDITION AT THIS LOCATION, I | | DO NOT RECALL EXTENSION OVER THE PROPERTY LINE. AS THE | | TWO PLANS CONFLICT, CLARIFY WHAT IS PROPOSED. | | | | 2/21/18 PER BUILDING OFFICIAL, OK FOR OVERHANG TO | | ENCROACH PROPERTY LINE INTO THE AREA COVERED BY THE | | RESTRICTIVE COVENANT. | | | | 3. SOME OF THE STRUCTURAL PAGES HAVE A DIGITAL | | SIGNATURE WHICH DO NOT COMPLY WITH FAC61G15-23 (STATES | | THE DOCUMENT WAS SIGNED BY "DOCUSIGN" RATHER THAN | | C.TIEDGE,PE. THIS HAS BEEN DISCUSSED WITH ENGINEER AND | | SENT TO FBPE TO ANSWER HER QUESTIONS. FOR THE STRUCTURE | | PERMIT, ENGINEER HAD ADDRESSED THE ISSUE BY UTILIZING A | | DIGITAL SEAL FROM A DIFFERENT VENDOR. | | | | SHEETS WHICH NEED A NEW DIGITAL SIGNATURE (SIGNED BY | | "DOCUSIGN" RATHER THAN ENGINEER): S001, S002, S003, | | S200, S302, S303, S304, S305 | | | | S201, S300 (MESSAGE: SIGNED AND ALL SIGNATURES ARE | | VALID, BUT WITH UNSIGNED CHANGES AFTER THE LAST | | SIGNATURE), | | | | NEW COMMENTS: | | | | 4. HOLLOWCORE SHOP DRAWINGS ARE NOT SIGNED AND SEALED | | AND ARE NOT REVIEWED BY SEOR, FAC61G15-30.005. THIS WAS | | ALSO NOT SUBMITTED WITH THE STRUCTURE PERMIT. WHAT IS | | THE PROPOSED INSTALLATION DATE? ALL DELEGATED | | ENGINEERING IS TO BE SUBMITTED, REVIEWED, AND APPROVED | | PRIOR TO INSTALLATION. THIS MAY BE A PROVISO ITEM UPON | | REQUEST, REQUIRED PRIOR TO INSTALLATION, IF THERE IS | | ADEQUATE TIME TO DO SO (ALLOW AT LEAST 30 DAYS AFTER | | PERMIT ISSUANCE BEFORE SETTING OF MECHANICAL EQUIPMENT | | FOR SUBMITTAL AND REVIEW OF REQUIRED DOCUMENTS). | | | | 5. MECHANICAL EQUIPMENT ANCHOR INFORMATION WAS | | PROVIDED. THIS WAS NOT REVIEWED BY DOR, AND DOES NOT | | INDICATE THE METHOD OF FASTENING PROPOSED, FBC B 1609, | | FBC 107. AS A STRUCTURE PERMIT HAS ALREADY BEEN ISSUED, | | PROVIDE PROPOSED INSTALLATION DATE. THIS MAY BE A | | PROVISO ITEM UPON REQUEST, REQUIRED PRIOR TO | | INSTALLATION, IF THERE IS ADEQUATE TIME TO DO SO (ALLOW | | AT LEAST 30 DAYS AFTER PERMIT ISSUANCE BEFORE SETTING | | OF MECHANICAL EQUIPMENT FOR SUBMITTAL AND REVIEW OF | | REQUIRED DOCUMENTS). | | | | 6. A202, A203, BLUE DOTS WERE ADDED TO THE PLAN. THIS | | APPEARS TO BE RELATED TO PLUMBING. CLARIFY WHY THIS | | INFORMATION WAS ADED TO THE PLAN FOR THIS REVIEW; THIS | | INFORMATION IS NOT TYPICALLY SHOWN ON THIS PAGE. EITHER | | REMOVE OR PROVIDE A LEGEND. ADDITIONAL REVIEW BY | | PLUMBING MAY BE REQUIRED, FBC 107. CHECK ALL PAGES. | | | | 7. NA | | | | 8. THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING | | PROVISOS: | | | | A. PRODUCT APPROVALS WERE NOT SUBMMITTED. ALL PRODUCT | | APPROVALS ARE TO BE SUBMITTED AND REVIEWED PRIOR TO | | INSTALLATION. PRODUCT APPROVALS ARE TO BE REVIEWED BY | | DESIGNER OF RECORD PRIOR TO SUBMITTALM, FBC B 1609. | | | | B. A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF PRODUCT | | APPROVAL INDICATING THE ASSEMBLY PROPOSED AND | | ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE | | ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR | | TO ROOF WORK COMMENCEMENT. | | | | C. MOVEABLE (NONFIXED) SEATING WAS NOT REVIEWED. | | | | D. REPLAT REQUIRED PRIOR TO CO. A COPY OF THE RECORDED | | REPLAT IS TO BE PROVIDED VIA EMAIL. | | | | E. RESTRICTIVE COVENANT REQUIRED PRIOR TO C.O. A COPY | | OF THE RECORDED DOCUMENT IS TO BE PROVIDED VIA EMAIL. | | | | F. SEPARATE PERMITS ARE REQUIRED; ONLY BUILDING, | | MECHANICAL, ELECTRICAL, PLUMBING ARE INCLUDED IN THIS | | REVIEW. SEPARATE PERMITS, FEES AND PLANS ARE REQUIRED | | FOR FIRE ALARM, FIRE SPRINKLER, FIRE UNDERGROUND LINE, | | PARKING LOT, GAS, LOW VOLTAGE, LANDSCAPING, AND OTHER | | SUCH ITEMS. | | | | G. THIS PROJECT HAS A SEPARATE ENGINEERING PERMIT; | | THERE MAY BE CONFLICTS BETWEEN THESE CIVIL SHEETS AND | | THE ISSUED ENGINEERING PERMIT. ISSUED AT CONTRACTOR'S | | RISK. APPLICANT IS TO REVISE ANY SHIEETS WHICH AFFECT | | BUILDING OR FIRE CODE COMPLIANCE. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-07-05 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-06-27 |
Time |
15:25 |
Sent To |
|
|
Notes |
2017-06-30 07:15:43 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | STRUCTURE PERMIT IS TO BE ISSUED PRIOR TO ISSUANCE OF | | THIS PERMIT. IF STRUCTURE PERMIT IS NOT ISSUED, VALUE | | IS TO BE ADJUSTED. | | | | 1-15. OK | | | | 16. FROM PREVIOUS LIST: REVISE PLAN TO SHOW COMPLIANCE | | WITH FBC B 705, TABLES 602, 705.8. DISTANCE TO ASSUMED | | PROPERTY LINE OR PROPERTY LINE NOT CLEAR, COMPLIANCE | | NOT CLEAR. PROVIDE A SITE PLAN, OR REVISE THE SITE | | PLAN, TO INCLUDE THE PROPERTY LINES, ASSUMED PROPERTY | | LINES, AND DIMENSIONS OF THIS BUILDING TO THE PROPERTY | | LINES, DIMENSION OF ADJACENT BUILDING (OR FUTURE | | ADJACENT BUILDING) TO THE ASSUMED PROPERTY LINE OR | | PROPERTY LINE. | | | | 2ND REVIEW, A004, A SITE PLAN SHOWING POD LINES WAS | | PROVIDED. THE EAST DISTANCE TO PROPERTY LINE IS SHOWN | | AS 14'2 1/8", BUT THIS IS SHOWN TO A POINT WHICH IS NOT | | WORST CASE. THE NORTHEAST CORNER OF THE BUILDING | | APPEARS TO TOUCH THE PROPERTY LINE ON AN ANGLE. THE | | OVERHAND APPEARS TO EXTEND OVER THE POD BOUNDARY LINE. | | THE NORTH SIDE OF THE BUILDING APPEARS TO SHOW A | | TRELLIS WHICH EXTENS TO "PBA #4 BOUNDARY LINE". | | | | REVISE AND SHOW COMPLIANCE WITH FBC B 705, TABLES 602, | | 705.8, 705.2 (PROJECTIONS). | | | | REVISE PLAN TO CLARIFY, WHAT IS "POD BOUNDARY LINE"? IS | | THIS PROPERTY UNDERGOING A REPLAT? IS THIS THE PROPOSED | | PROPERTY LINE? IF THIS IS NOT THE PROPOSED NEW PROPERTY | | LINE (AFTER REPLAT), REVISE PLAN TO SHOW PROPOSED NEW | | PROPERTY LINES (AFTER REPLAT). | | | | FEEL FREE TO CONTACT ME TO DISCUSS RESOLUTIONS TO BE | | APPROVED PRIOR TO RESUBMITTAL. | | | | 17-27. OK | | | | 28. FBC A 226, 902, DINING SURFACES, REVISE PLAN TO | | SHOW COMPLIANCE. | | | | 2ND REVIEW, BANYAN GRILL DOES NOT APPEAR TO HAVE AN | | ACCESSIBLE SECTION. PLEASE EXPLAIN RATIONALE. | | | | 29-49. OK | | | | THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING PROVISOS: | | | | A. PRODUCT APPROVALS NOT SUBMMITTED. ALL PRODUCT | | APPROVALS ARE TO BE SUBMITTED AND REVIEWED PRIOR TO | | INSTALLATION. PRODUCT APPROVALS ARE TO BE REVIEWED BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. | | | | B. A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF PRODUCT | | APPROVAL INDICATING THE ASSEMBLY PROPOSED AND | | ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE | | ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR | | TO ROOF WORK COMMENCEMENT. | | | | C.PROVIDE A DETAIL FOR THE HORIZONTAL 1 HOUR ASSEMBLY, | | EITHER TESTED ASSEMBLY OR CALCULATED, FBC B 703.2. | | REVISE PLAN TO INCLUDE DAMPERS REQUIRED, OR REVISE PLAN | | TO INCLUDE EXCEPTION. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-03-21 |
|
|
Cont ID |
|
Sent By |
S. Hill |
Date |
2017-03-21 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-03-06 |
Time |
11:38 |
Sent To |
|
|
Notes |
2017-03-10 15:05:25 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. FBC 1007, FBC A 207, REVISE PLAN TO STATE WHICH | | METHOD OF COMPLIANCE IS ELECTED (IBC 2000 OR IBC 2003). | | | | 2. CIRCULATION PATH NOT CLEAR, FBC A 206.3; IN | | PARTICULAR, COMMUNICATION BETWEEN GARAGE AND CLUBHOUSE | | FLOORS. PROVIDE INFORMATION REGARDING THE USE OF THE | | SPACES AND HOW OCCUPANTS, BOTH EMPLOYEES AND GUESTS, | | ACCESS THE SPACES. IT IS RECOMMENDED TO SEND THIS | | INFORMATION VIA EMAIL PRIOR TO RESUBMITTAL IN ORDER TO | | PROVIDE A COMPLETE REVIEW. | | | | PLAN SHOWS A STAIR WHICH APPEARS TO BE AN EMPLOYEE | | STAIR AS IT IS LOCATED IN EMPLOYEE AREAS | | (DELIVERY/DUMPSTER AREA ON 1ST FLOOR, MAINTENANCE AREA | | ON BASEMENT LEVEL). ACCESSIBLE ROUTE, VERTICAL | | ACCESSIBILITY NOT CLEAR BETWEEN LEVELS. IT IS NOT CLEAR | | UNDER WHICH EXEPTION VERTICAL ACCESSIBLITY IS NOT | | PROVIDED. USE OF THE GARAGE AREA AND THE NEED FOR | | EMPLOYEES (OR OTHER OCCUPANTS) TO TRAVEL FROM ONE FLOOR | | TO THE OTHER IS NOT CLEAR. | | | | 3. A101, CLARIFY USE OF GOLF CART PARKING FACILITY. WHO | | WILL USE THIS AREA, EMPLOYEES ONLY OR VISITORS? WILL | | GOLF CARTS BE RENTED? WILL CARS BE SELF PARKED OR | | PARKED BY EMPLOYEES? A MAINTENANCE AREA IS SHOWN; IS | | THIS FOR FACILITY OWNED CARTS OR PRIVATELY OWNED CARTS? | | IS THIS GARAGE PARKING (RESIDENTS OR OTHERS SELF PARK | | THEIR CARTS), OR IS THIS STORAGE (FACILITY OWNED CARTS | | BROUGHT OUTSIDE AS NEEDED BY EMPLOYEES)? FBC A | | 206.2.15, 1006. THE ACCESSIBLE ROUTE REQUIRED IS NOT | | CLEAR. REVISE PLAN TO ADDRESS ACCESSIBILITY ISSUES. | | | | 4. EXIT FROM KITCHEN ROOM 100, SHEET A003, THE EXIT | | DISCHARGE IS NOT CLEAR. THE EXIT OPENS INTO THE | | DELIVERY & DUMPSTER AREA #130, AND A GATE WHICH | | COMPLIES WITH FBC B1008.1.2 IS NOT PROVIDED; SEE ALSO | | 1008.1.1 (4 FT MAX), 1008.2 (GATES TO MEET SAME | | REQUIREMENTS AS DOORS), 1003.1 (REQUIREMENTS APPLICABLE | | TO EXIT DISCHARGE). EXIT DISCHARGE IS TO BE CONTINUOUS | | TO THE PUBLIC WAY, 1027.5. | | | | 5. A003, FBC B 1014.2, REVISE PLAN TO EXPLAIN RATIONALE | | OF EXITING THROUGH A DUMPSTER AREA, ESPECIALLY FROM THE | | BASEMENT. IT APPEARS THAT EXITING THROUGH A HIGHER | | HAZARD AREA IS PROPOSED. IF EXIT STRATEGY IS NOT | | REVISED, THIS IS TO BE APPROVED VIA EMAIL BY FIRE AND | | BUILDING PRIOR TO RESUBMITTAL. | | | | 6. A003, ACCESSIBLE ROUTE NOT CLEAR FOR COVERED OUTDOOR | | DINING FROM RAMP. THE ROUTE IS BLOCKED BY TABLES, | | REVISE OR CLARIFY. | | | | 7. A101 SHOWS A 4" ELEVATION CHANGE AT THE DOOR TO THE | | STAIR. FBC A 403.4, 303.2, FBC B 1008.1.5, IT IS NOT | | CLEAR UNDER WHICH EXCEPTION THIS IS PERMITTED. REVISE | | PLAN TO INCLUDE APPLICABLE EXCEPTION, OR REVISE PLAN TO | | COMPLY WITH THESE CODE SECTIONS. VERIFY THAT THERE ARE | | NO OTHER CHANGES IN ELEVATION IN THE MEANS OF EGRESS, | | WITH THE EXCEPTION OF STAIRS AND RAMPS. | | | | 8. A101 AT THE BASE OF THE STAIR AT DUMPSTER AREA, | | THERE APPEARS TO BE A DRAIN. REVISE PLAN TO SHOW | | COMPLIANCE WITH FBC A 302.3 (GRATES), 403.3 (SLOPE). | | | | 9. A213, THE RAMP DETAIL, TOP LANDING AT DOOR, DOOR | | DOES NOT APPEAR TO HAVE THE 18" MANEUVERING CLEARANCE | | REQUIRED, REVISE, FBC A 404.2.4.1. | | | | 10. A003, REVISE OCCUPANT LOAD TO ROUND UP (CANNOT HAVE | | A FRACTION OF AN OCCUPANT), FBC B TABLE 1004.1.2. | | | | 11. A001 BUILDING DATA, A/C SPACE IS 7673, BUT A003 | | OCCUPANCY LOAD SCHEDULE APPEARS TO SHOW A TOTAL SF AREA | | UNDER AIR OF 6895, REVISE PLAN TO CLARIFY DISCREPANCY. | | OUTDOOR AREAS, OCCUPANCY LOAD SCHEDULE ALSO APPEAR TO | | HAVE A DISCREPANCY. REVISE TO CLARIFY, SUBTOTALS | | SUGGESTED. | | | | 12. A003, REVISE PLAN TO CLARIFY PURPOSE OF COVERED | | GOLF TERRACE 126, AND CLARIFY USE OF 100 SF PER PERSON | | FOR THIS AREA WHICH APPEARS TO BE AN AREA WHERE | | OCCUPANTS MAY CONGREGATE. 100 SF PER PERSON IS USED FOR | | OFFICE SPACE WHICH HAS FURNISHINGS; THIS AREA APPEARS | | TO BE OPEN. | | | | 13. A003 IS LACKING MANY DOORS, FBC 107. REVISE PLAN TO | | BE CONSISTENT WITH PROPOSED CONSTRUCTION. FOR INSTANCE, | | NO DOORS LEADING FROM BANYAN GRILLE TO COVERED OUTDOOR | | DINING. DOORS ARE SHOWN ON OTHER SHEETS. | | | | 14. A SHEETS SPECIFY ELEVATIONS IN NAVD88. CIVIL SHEETS | | UTILIZE NGVD29 VERTICAL DATUM (SEE MASTER PLAN SHEET 2 | | WHICH REFERENCES SFWMD BASIN CRITERIA IN NGVD29, COVER | | SHEET WHICH INCLUDES A NOTE THAT ALL ELEVATIONS ARE | | NGVD29). BOTH A SHEETS AND CIVILS SPEC FINISHED FLOOR | | AT 27.50. CLARIFY VERTICAL DATUM; BOTH ARE TO USE THE | | SAME OR TO INCLUDE CONVERSIONS (NOT A CONVERSION | | FACTOR). NOTE THAT THE CITY STANDARD IS NGVD29 UNTIL | | NEW FIRMS ARE ADOPTED. IT IS RECOMMENDED THAT ALL | | ELEVATIONS BE PROVIDED IN NGVD29. | | | | THE VERTICAL DATUM DISCREPANCY RESULTS IN A CONFLICT OF | | APPROXIMATELY 1.55 FEET. REVISE ELEVATIONS TO BE | | CONSISTENT AND VERIFY ELEVATIONS ON OTHER BUILDINGS FOR | | THIS PROJECT AS THIS MAY AFFECT (AMONG OTHER THINGS) | | ACCESSIBILITY AND UTILITIES. | | | | 15. PROVIDE A COPY OF THE SURVEY FOR THIS PARCEL, FBC | | 107, FBC TABLE 602, 705.8. | | | | 16. REVISE PLAN TO SHOW COMPLIANCE WITH FBC B 705, | | TABLES 602, 705.8. DISTANCE TO ASSUMED PROPERTY LINE OR | | PROPERTY LINE NOT CLEAR, COMPLIANCE NOT CLEAR. PROVIDE | | A SITE PLAN, OR REVISE THE SITE PLAN, TO INCLUDE THE | | PROPERTY LINES, ASSUMED PROPERTY LINES, AND DIMENSIONS | | OF THIS BUILDING TO THE PROPERTY LINES, DIMENSION OF | | ADJACENT BUILDING (OR FUTURE ADJACENT BUILDING) TO THE | | ASSUMED PROPERTY LINE OR PROPERTY LINE. | | | | 17. A201 SHOWS TWO ARROWS IN THE HALL AT THE BATHROOMS | | WEST OF THE WOMENS LOCKER, REVISE TO CLARIFY WHAT THE | | GRAPHIC DEPICTS. | | | | 18. A003 AND OTHER SHEETS, REVISE PLAN TO SHOW | | MANEUVERING CLEARANCE, PULL SIDE, FOR BOTH DOORS AT | | MENS VESTIBULE 116 (MINIMUM 18"), FBC A 404.2.4.1. | | | | 19. SHOE DROP 119, FBC B 1008.1.1, THE ENTRY TO THE | | SPACE IS SHOWN AS 2'6", MINIMUM 32" REQUIRED, REVISE. | | CHECK ALL. | | | | 20. THE RESTAURANT BAR AREA INCLUDES TABLES AND CHAIRS | | WHICH APPEAR TO RESTRICT THE ACCESSIBLE ROUTE, FBC A | | CHAPTER 4. REVISE TO CLARIFY REQUIREMENTS AND DESIGN | | INTENT. | | | | 22. A701, FBC 1008.1.10, PANIC DEVICES OR FIRE EXIT | | HARDWARE IS REQUIRED ON ALL DOORS AND GATES IN THE | | MEANS OF EGRESS SERVING ASSEMBLY OCCUPANCY WITH AN | | OCCUPANT LOAD OVER 50. THE DOOR LOCKSET GROUPS DOES NOT | | INCLUDE PANIC DEVICES OR FIRE EXIT HARDWARE. REVISE THE | | INTERIOR DOOR SCHEDULE, EXTERIOR DOOR SCHEDULE, | | EXTERIOR WINDOW SCHEDULE, ANY OTHER APPLICABLE AREAS. | | | | IF THERE ARE ANY GATES IN THE MEANS OF EGRESS, REVISE | | PLAN TO INCLUDE THE GATE INFORMATION. | | | | 23. I WAS UNABLE TO LOCATE SOME OF THE DOORS TYPES IN | | THE SCHEDULE (SUCH AS TYPE P AND TYPE Q). THE DOORS DO | | NOT APPEAR TO COMPLY WITH THE REQUIREMENTS FOR THIS | | OCCUPANCY. REMOVE (OR X OUT) DOORS WHICH ARE NOT FOR | | THIS PROJECT. IF THEY ARE TO BE INCLUDED, PLEASE DIRECT | | TO THE LOCATION. | | | | 24. A801, TOILET, THE TOP OF THE SEAT IS TO BE A MAX OF | | 19"; THE DETAIL APPEARS TO DEPICT THE LOWER PART OF THE | | TANK, ABOVE THE LID. REVISE DETAIL TO CLEARLY SHOW THAT | | THE SEAT IS TO BE A MAX OF 19", FBC A 604.4. | | | | 25. A802 ADA NOTES INCLUDE AN OLD CODE REFERENCE (FBC | | 11-4.13.9), REVISE TO REMOVE. | | | | 26. WOMENS 107 ADA, SEE FBC A 604.8.1.6 AND 604.8.1.7 | | AND ADVISORY, DOOR IS TO BE DIAGONAL TO THE WATER | | CLOSET. | | | | 27. LOCKER ROOMS, CHANGING ROOMS, SEE FBC A 803. REVISE | | PLAN TO SHOW COMPLIANCE WITH ALL REQUIREMENTS. | | | | HTTPS://WWW.ACCESS-BOARD.GOV/GUIDELINES-AND-STANDARDS/R | | ECREATION-FACILITIES/GUIDES/SPORTS-FACILITIES/DRESSING, | | -FITTING,-OR-LOCKER-ROOMS | | | | 28. FBC A 226, 902, DINING SURFACES, REVISE PLAN TO | | SHOW COMPLIANCE. | | | | 29. RECEPTION AREA A201, OTHER SERVICE OR CHECK OUT | | AREAS (FOR EXAMPLE, SHOE DROP, PRO SHOP) PROVIDE A | | DETAIL FOR THE SERVICE (OR CHECK OUT) COUNTERS, FBC A | | 227, 904. | | | | 30. PROVIDE A DETAIL FOR THE HORIZONTAL 1 HOUR | | ASSEMBLY, EITHER TESTED ASSEMBLY OR CALCULATED, FBC B | | 703.2. REVISE PLAN TO INCLUDE DAMPERS REQUIRED, OR | | REVISE PLAN TO INCLUDE EXCEPTION. | | | | 31. A ROOF HATCH IS SHOWN ON A904, BUT I WAS UNABLE TO | | LOCATE THIS ITEM ON THE ENERGY CALC INPUT DATA REPORT, | | EITHER INCLUDE OR ADVISE AS TO WHERE THIS CAN BE FOUND, | | FBC 107. IF A ROOF HATCH IS NOT PROPOSED FOR THIS | | PROJECT, REMOVE OR X OUT DETAIL. | | | | 32. DETAIL 9-A904, STRUCTURAL INFORMATION NOT INCLUDED. | | EITHER REVISE TO INCLUDE OR, IF NOT LOCATED ELSEWHERE | | ON THE PLAN, THIS WILL BE A PROVISO ITEM - SUBJECT TO | | INSPECTOR'S DISCRETION, A REVISION MAY BE REQUIRED | | PRIOR TO INSTALLATION. | | | | 33. S004 NOMINAL C&C WIND PRESSURES STATE THE PORTE | | COCHERE IS OPEN, SEE DEFINITION, DOES NOT APPEAR TO | | MEET THE CRITERIA FOR AN OPEN BUILDING, SEE ASCE7-10 | | 26.1.2.2 DEFINITION OF OPEN BUILDING IS A BUILDING WITH | | EACH WALL AT LEAST 80% OPEN. THE PORTE COCHERE IS A | | PORTION OF A BUILDING, ONE WALL ENCLOSED. IF ENGINEER | | DISAGREES, PUT RATIONALE IN WRITING AND SEND VIA EMAIL | | FOR CONSIDERATION PRIOR TO RESUBMITTAL. | | | | 34. S102, WOOD CONNECTOR SCHEDULE, MARK 5 SPECS LGT, 1 | | 3/4" TITENS. SEE CATALOG, SEVERAL DIFFERENT LGT, REVISE | | TO SPECIFY WHICH CONNECTOR. IF LGT 2 IS PROPOSED, THE | | FASTENER SPECIFIED ON THE PLAN IS NOT THE SAME AS THE | | ONE SPECIFIED IN THE SIMPSON CATALOG (1 3/4" TITEN | | RATHER THAN 2 1/4" TITEN 2). REVISE OR PROVIDE | | CALCULATIONS OR OTHER DOCUMENTATION TO SUPPORT USE OF A | | SMALLER FASTENER. CHECK ALL. | | | | 35. FS471, THE A SHEETS HAVE A TITLE BLOCK FOR RANDALL | | STOFFT AS ARCHITECT, BUT THE DIGITAL SIGNATURE IS FOR | | DON DURANTE. EITHER REVISE THE TITLE BLOCK AND SEAL TO | | SHOW DON DURANTE AS ARCHITECT, OR HAVE THE SHEETS | | SIGNED AND SEALED BY RANDALL STOFFT. IF THIS IS AN | | ERROR IN THE DIGITAL SIGNATURE, PLEASE CONTACT THE | | ISSUER. ISSUER HAS CONFIRMED THAT THIS IS NOT CORRECT; | | THE "SIGNED BY" NAME IS TO MATCH THE NAME OF THE | | INDIVIDUAL SIGNING. | | | | 36. THE SEAL FOR RANDALL STOFFT IS NOT CONSISTENT WITH | | THE DESCRIPTION OF SEAL FAC 61G1-16.002. EITHER REVISE | | OR ADVISE VIA EMAIL THAT ARCHITECT OBJECTS TO THE | | COMMENT. AN EMAIL WILL THEN BE SENT TO FLORIDA BOARD OF | | ARCHITECTS TO DETERMINE WHETHER OR NOT THE SEAL ON THE | | PLAN IS ACCEPTABLE. | | | | IF ARCHITECT OBJECTS TO EITHER COMMENT, PLEASE CONTACT | | ME. IT APPEARS THAT ALL A SHEETS NEED TO BE RESUBMITTED | | WITH A CORRECTED SEAL IMAGE AND CORRECT SIGNATURE & | | SEAL. TO AVOID PERMIT ISSUANCE DELAYS, PLEASE DO NOT | | RESUBMIT WITHOUT THESE TWO ITEMS CORRECTED UNLESS WE | | HAVE DISCUSSED THIS IN ADVANCE. | | | | 37. CIVIL SHEETS ARE REQUIRED, SEE FIRE COMMENTS. | | DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS, FS471. IF THIS DESIGN PROFESSIONAL DOES NOT | | HAVE A DIGITAL OR ELECTRONIC SIGNATURE, PLEASE CONTACT | | ME REGARDING ALTERNATE METHODS OF SUBMITTAL. | | | | 38. ENERGY INPUT REPORT HAS THE FOLLOWING ISSUES: NO | | DOORS SHOWN, WATER HEATER NOT INCLUDED. CHECK ALL | | ITEMS. | | | | 39. INCORPORATE REQUIREMENT OF 23.2 R VALUE FOR THE | | ROOF (PER ENERGY CALCS) INTO THE PLAN, OR ADVISE WHERE | | THIS INFORMATION CAN BE FOUND, FBC 107. | | | | 40. PRODUCT APPROVALS NOT SUBMMITTED. ALL PRODUCT | | APPROVALS ARE TO BE SUBMITTED AND REVIEWED PRIOR TO | | INSTALLATION. PRODUCT APPROVALS ARE TO BE REVIEWED BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. | | | | 41. FBC B 406, REVISE PLAN TO NOTE THE GOLFCART GARAGE | | AS AN ENCLOSED PARKING GARAGE. 406.6, IT IS NOT CLEAR | | WHERE THE CO2 CENSORS ARE LOCATED, PLEASE ADVISE. | | | | 42. REVISE PLAN TO PROVIDE INFORMATION REGARDING WHAT | | WILL BE STORED IN THE STORAGE AREAS, FBC 107. INCLUDE | | BATTERY STORAGE, CHEMICAL STORAGE; AMOUNTS, MSDS SHEETS | | IF APPLICABLE, FUEL AMOUNTS. | | | | 43. DETAIL 9-A904 HAS TEXT WHICH IS NOT LEGIBLE; | | REVISE. | | | | 44. DETAIL 9-A904 REFERS TO DETAIL MA/FA/BA 115, ADVISE | | AS TO WHERE THIS CAN BE LOCATED, FBC 107. | | | | 45. FBC A 209, 503.5, REVISE PLAN TO INCLUDE CLEARANCE | | REQUIRED AT THE PORTE COCHERE (114" MINIMUM). | | | | 46. A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF | | PRODUCT APPROVAL INDICATING THE ASSEMBLY PROPOSED AND | | ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE | | ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR | | TO ROOF WORK COMMENCEMENT. | | | | 47. S102 SPECS 5/8" APA SHEATHING, A SHEETS INCLUDE | | DETAILS WITH 19/32", 3/4" IN VARIOUS PLACES (FOR | | INSTANCE, SEE A904), PLEASE CORRELATE. | | | | 48. REVISE STRUCTURAL PAGES TO INCLUDE VERTICAL DATUM, | | FBC 107 (FOR INSTANCE, S103). SHEET S201 INCLUDES A TOP | | OF FOOTING EELEVATION IN SECTION 1; 23'2" NAVD. SEE | | OTHER COMMENTS REGARDING VERTICAL DATUM. IF NGVD29 IS | | USED ON OTHER SHEETS, AND NAVD88 IS USED FOR S SHEETS, | | INCLUDE CONVERSION. | | | | 49. FP01, NOTE 22, PLEASE COMPLETE INFORMATION. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2018-03-22 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-03-22 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-03-22 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-01-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-01-30 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-01-30 |
Time |
14:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2017-07-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-07-03 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-07-03 |
Time |
11:59 |
Sent To |
|
|
Notes |
2017-07-03 13:17:21 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PAGE E-2-1 | | 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION | | FOR PERSONNEL (B) OTHER THAN DWELLING UNITS | | | | (8) GARAGES, SERVICE BAYS, AND SIMILAR AREAS | | | | | | PAGE E-3-1 | | 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION | | FOR PERSONNEL (B) OTHER THAN DWELLING UNITS | | ALL 125-VOLT, SINGLE-PHASE 15- AND 20-AMPERE | | RECEPTACLES | | INSTALLED IN THE LOCATIONS SPECIFIED IN 210.8(B)(1) | | THROUGH | | (8) SHALL HAVE GROUND-FAULT CIRCUITINTERRUPTER | | PROTECTION FOR PERSONNEL. | | | | (2) KITCHENS | | | | | | PAGE E-41 | | | | RISER SHOWS 800A GENERATOR SET WITH 620A OF WIRE | | | | PAGE E-6-1 | | | | LOAD CALCULATION SHOWS PERCENTAGES USED FOR LOAD CALC | | LIKE 110%, 121% ? | | HVAC LOAD OF 5.7 ? THERE IS OTHERS SHOWN HOW IS 5.7 THE | | LOAD FOR ACS? |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-02-14 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2017-02-14 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2017-02-14 |
Time |
11:17 |
Sent To |
|
|
Notes |
2017-02-14 11:17:29 | APPLICABLE CODES IN EFFECT: | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 | | COMMENTS: | | | | 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE | | PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE | | PERMITS AND DATA SPECIFICATION SHEET SUBMITTALS FOR ALL | | LOW VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED TO FIRE | | ALARM, CCTV, PHONE AND DATA, WIRELESS SYSTEMS, CARD | | READERS, GENERATOR, KITCHEN HOODS ETC. A NOTE WILL | | SUFFICE. | | 2. ADD A GENERAL NOTE TO PROVIDE PER FBC EC 405.7.4- | | COMPLETION DOCUMENTS PER CODE SECTION. FBC EC 405.7.3- | | VOLTAGE DROP | | 3. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO | | INDICATE NEC 110.16. ARC FLASH WARNING SIGNS AND NEC | | 110.24- AVAILABLE FAULT CURRENT- FIELD MARKINGS; SEE | | VERBIAGE IN CODE. | | 4. PROVIDE THE AVAILABLE FAULT CURRENT AT THE UTILITY | | TRANSFORMER. FBC 107.3.5 | | 5. PER FBC EC 405.7- A MINIMUM OF 50% OF ALL 125V, 15 | | AND 20AMP RECEPTACLES SHALL BE AUTOMATICALLY CONTROLLED | | WHERE INSTALLED IN PRIVATE OR OPEN OFFICES AND COMPUTER | | CLASSROOMS. THIS INCLUDES MODULAR PARTITIONS TOO. SHOW | | COMPLIANCE ACCORDINGLY. | | 6. PROVIDE A NOTE TO INDICATE COMPLIANCE WITH FBC EC | | 405.2 AUTOMATIC LIGHTING CONTROL AND LIGHTING DENSITIES | | PER CODE SECTION. | | 7. PLEASE ADDRESS BUILDING, FIRE AND MECHANICAL | | COMMENTS RELATED TO ELECTRICAL. | | 8. PROVIDE A NOTE ON PLANS TO INDICATE NEC 300.5 | | REQUIREMENTS FOR ALL UNDERGROUND RACEWAYS. | | 9. PROVIDE 1/2" DETAIL OF MAIN ELECTRICAL ROOM( WHERE | | MDP IS LOCATED) TO VERIFY CLEARANCE. FBC 107.3.5 | | 10. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLES IN THE | | BASEMENT AREA AND MAINTENANCE SECTION PER NEC 210.8B | | (6)INDOOR WET LOCATION (8) SIMILAR AREAS WHERE | | ELECTRICAL DIAGNOSTIC EQUIPMENT, ELECTRICAL HAND TOOLS | | ARE TO BE USED.- THAT WILL INCLUDE ALL 125V SINGLE | | PHASE 15 OR 20A RECEPTACLES. | | 11. PLEASE NOTE THAT THE SEPARATE GENERATOR PERMIT | | REQUIRED WILL NEED TO PROVIDE A SELECTED LOAD | | ARRANGEMENT BASED ON CUSTOMER SELECTED LOADS. MANUAL | | TRANSFER SELECTED. NEC 702.4.B1. ALSO SIGNAGE IS TO BE | | PROVIDED PER NEC 702.7A. A NOTE WILL SUFFICE | | 12. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL | | FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS | | REGARDING THIS PROJECT. | | | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2017-02-24 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-02-24 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-02-24 |
Time |
17:04 |
Sent To |
|
|
Notes |
2017-02-24 17:13:18 | PER MGONZALES EMAIL OF 2/24/17 ENGINEERING REVIEW WILL | | BE DONE UNDER FORMAL ENGINEERING SUBMITTAL ONLY. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2017-06-14 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-06-14 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-06-08 |
Time |
09:28 |
Sent To |
|
|
Notes |
2017-06-09 07:54:26 | 3200 NORTH CONGRESS AVENUE - CLUBHOUSE | | PERMIT #16110061 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | **PROVISO - REVISION NEEDED** | | | | REPEAT COMMENT - SHEET E-2.2: PER SECTION 12.3.4.3.3, | | PROVIDE SPEAKER/STROBE NOTIFICATION APPLIANCES AS | | ASSEMBLY OCCUPANCIES WITH AN OCCUPANT LOAD EXCEEDING | | 300 OCCUPANTS SHALL RECEIVE FIRE ALARM NOTIFICATION BY | | VISIBLE SIGNALS AND VOICE ANNOUNCEMENTS. PROVIDE A | | PRE-RECORDED FIRE ALARM EVACUATION MESSAGE NOTIFYING | | OCCUPANTS AN EMERGENCY HAS BEEN REPORTED IN THE | | BUILDING, LOCATE THE NEAREST EXIT, AND EXIT THE | | BUILDING IMMEDIATELY. DO NOT USE THE ELEVATOR. | | | | REPEAT COMMENT - SHEET E-2.2: NO NOTIFICATION | | APPLIANCES PROVIDED IN ALL RESTROOMS, CHANGING ROOMS OR | | SHOWER SPACES. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-02-07 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2017-02-07 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2017-02-07 |
Time |
12:11 |
Sent To |
|
|
Notes |
2017-02-07 13:30:08 | 3200 NORTH CONGRESS AVENUE - CLUBHOUSE | | PERMIT #16110061 & 17010998 (TWO DIFFERENT PERMITS FOR | | SAME STRUCTURE?) | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | GENERAL: PER NFPA 241 SECTION 8.7.2.3, WHERE | | UNDERGROUND WATER MAINS AND HYDRANTS ARE TO BE | | PROVIDED, THEY SHALL BE INSTALLED, COMPLETED, AND IN | | SERVICE PRIOR TO VERTICAL CONSTRUCTION WORK OR | | ACCUMULATION OF COMBUSTIBLE MATERIALS. PER SECTION | | 18.3.4.1 (NFPA 1), FIRE HYDRANTS SHALL BE PROVIDED WITH | | CLEARANCES OF 7'-6" TO THE FRONT AND SIDES AND 4'-0" TO | | THE BACKSIDE OF THE STEAMER CAP. | | | | GENERAL: A SUB PERMIT (UG FIRELINE) IS NEEDED TO | | INSTALL FIRE MAINS AND FIRE HYDRANTS. | | | | GENERAL: PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN | | TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE | | PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE | | PROVIDED AS REQUIRED BY THE AUTHORITY HAVING | | JURISDICTION.TEMPORARY CONSTRUCTION TRAILERS OR MODULAR | | BUILDINGS WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE | | FOLLOWING: | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | PER TABLE 4.2.1: | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | GENERAL: PROVIDE DRAWING NOTE INDICATING ALL | | CONSTRUCTION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | GENERAL: PROVIDE AN EXTERIOR KEY SAFE TO ALLOW | | EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE | | BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE | | ORDERED FROM WWW.KNOXBOX.COM. | | | | GENERAL: STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS | | CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO | | THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS | | 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED | | REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R/F/RF | | DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA | | ADMINISTRATIVE CODE 69A-60.0081. | | | | CIVIL: SUBMIT OFFICIAL CIVIL DRAWINGS SHOWING ALL FIRE | | DEPARTMENT ACCESS ROADS, FIRE MAINS, AND FIRE HYDRANTS. | | CIVIL PLANS INDICATE FOR REFERENCE ONLY. MOST OF THE | | SAME CIVIL PLANS ARE SUBMITTED MULTIPLE TIMES; AND | | DRAWING SET IS NOT A COMPLETE CIVIL SET. | | | | SITE: PER SECTION 18.2.3.4.1.1 (NFPA 1), FIRE | | DEPARTMENT ACCESS ROADS SHALL HAVE A SURFACE DESIGNED | | TO ACCOMMODATE FIRE APPARATUS WEIGHING AT LEAST 38 | | TONS. ACCESS ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF | | NOT LESS THAN 20 FEET AND AN UNOBSTRUCTED VERTICAL | | CLEARANCE OF NOT LESS THAN 13 FEET 6 INCHES. | | | | SITE: PER SECTION 18.2.3.5.3 (NFPA 1), FIRE LANES SHALL | | BE MARKED WITH FREESTANDING SIGNS READING, "FIRE LANE - | | NO PARKING BY ORDER OF THE FIRE DEPARTMENT." SIGNS | | SHALL BE 12" X 18" WITH A WHITE BACKGROUND AND RED | | LETTERS AND SHALL BE A MAXIMUM OF SEVEN FEET IN HEIGHT | | TO THE BOTTOM OF THE SIGN. SIGNS SHALL BE WITHIN SIGHT | | OF THE TRAFFIC FLOW AND BE SPACED A MAXIMUM OF 60 FEET | | APART. | | | | CIVIL: PER NFPA 1 SECTION18.2.3.2.1 A FIRE DEPARTMENT | | ACCESS ROAD SHALL EXTEND TO WITHIN 50 FEET OF AT LEAST | | ONE EXTERIOR DOOR THAT CAN BE OPENED FROM THE OUTSIDE | | AND THAT PROVIDES ACCESS TO THE INTERIOR OF THE | | BUILDING. THE CURRENT DRIVE AISLE NEAR THE CLUBHOUSE IS | | NOT AN APPROVED FIRE LANE BECAUSE IT DOES NOT HAVE A | | MINIMUM CLEAR WIDTH OF 20 FEET AND CANNOT RELIABLY | | REMAIN UNOBSTRUCTED FROM GOLF CARTS, VEHICLES, ETC AT | | ALL TIMES AS IS SHOWN IN SHEET A204.ADDITIONALLY THE | | PORTE COCHIERE MAY IMPEDE FIRE RESCUE OPERATIONS. | | | | CIVIL: COULD NOT LOCATE A FIRE HYDRANT NEAR THE | | CLUBHOUSE. | | | | SHEET A003: BASEMENT STAIR AND KITCHEN OCCUPANTS | | INDICATE AN EXIT DISCHARGE THROUGH THE DELIVERY AND | | DUMPSTER AREA. | | | | SHEET A003: EGRESS DOOR NEAR THE ADA RAMP IS OBSTRUCTED | | BY TABLE AND CHAIRS. | | | | GENERAL: PROVIDE A KITCHEN EQUIPMENT SCHEDULE. | | | | GENERAL: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT | | DOORS WITH EXIT SIGNS. | | | | GENERAL: FOR ASSEMBLY OCCUPANCIES WITH AN OCCUPANT LOAD | | OF 100 OR MORE PERSONS (50 PERSONS PER THE FLORIDA | | BUILDING CODE), PANIC HARDWARE SHALL BE PROVIDED ON | | DOORS TO RELEASE THE LOCK/LATCH. NO OTHER LOCKS OR | | LATCHES ARE PERMITTED THAT WOULD NOT BE RELEASED BY THE | | PANIC HARDWARE. AS A SUBSTITUTE FOR PANIC HARDWARE, THE | | MAIN ENTRANCE (ONLY) IS PERMITTED TO HAVE AN INTERIOR | | KEYED DOOR LOCK (AND NO LATCH) WITH A READILY VISIBLE | | SIGN STATING THIS DOOR TO REMAIN UNLOCKED WHEN THE | | BUILDING IS OCCUPIED. SIGN LETTERS SHALL BE AT LEAST 1 | | INCH IN HEIGHT. KEYED LOCK TO BE EQUIPPED WITH AN | | "OPEN/LOCKED" INDICATOR WINDOW (SUCH AS ADAMS RITE 4089 | | OR SIMILAR). A THUMB TURN STYLE LOCK IS NOT PERMITTED | | TO BE SUBSTITUTED FOR A KEYED LOCK.SHEET | | A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED | | AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON | | THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED DURING PLAN RESUBMISSION. | | | | SHEET FP-1.1: THE ENTIRE BASEMENT IS STORAGE; PROTECT | | ENTIRE SPACE AS ORDINARY HAZARD. | | | | SHEET FP-1.2: PROTECT MERCANTILE PRO SHOP #113 AS | | ORDINARY HAZARD. | | | | SHEET E-1.2: DOES NOT APPEAR TO BE ANY EXTERIOR | | EMERGENCY LIGHTING ON EAST SIDE OF BUILDING AND ADA | | RAMP AREA. | | | | SHEET E-2.2: PER SECTION 12.3.4.3.3, PROVIDE | | SPEAKER/STROBE NOTIFICATION APPLIANCES AS ASSEMBLY | | OCCUPANCIES WITH AN OCCUPANT LOAD EXCEEDING 300 | | OCCUPANTS SHALL RECEIVE FIRE ALARM NOTIFICATION BY | | VISIBLE SIGNALS AND VOICE ANNOUNCEMENTS. PROVIDE A | | PRE-RECORDED FIRE ALARM EVACUATION MESSAGE NOTIFYING | | OCCUPANTS AN EMERGENCY HAS BEEN REPORTED IN THE | | BUILDING, LOCATE THE NEAREST EXIT, AND EXIT THE | | BUILDING IMMEDIATELY. DO NOT USE THE ELEVATOR. | | | | SHEET E-2.2: NO NOTIFICATION APPLIANCES PROVIDED IN ALL | | RESTROOMS, CHANGING ROOMS OR SHOWER SPACES. | | | | SHEET M-1.2 & M-1.3: KITCHEN EXHAUST FANS ARE | | TERMINATING AT AN OUTSIDE WALL IN LIEU OF ROOFTOP | | TERMINATION. THE FANS ARE LOCATED WITHIN 10 FEET OF THE | | COMBUSTIBLE ROOF WHICH IS NOT PERMITTED BY NFPA 96 | | SECTION 7.8.3. | | | | NOTE: REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE | | THE OWNER, CONTRACTOR, ETC. OF THE RESPONSIBILITY OF | | COMPLIANCE WITH CODE (NFPA 1, SECTION 1.14.4).FBC | | SECTION 105.4.1 PERMIT INTENT: A PERMIT ISSUED SHALL BE | | CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND | | NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE | | ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL | | ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM | | THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, | | CONSTRUCTION OR VIOLATIONS OF THIS CODE. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2018-04-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-04-07 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-04-07 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-07 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-07 |
Time |
07:35 |
Sent To |
|
|
Notes |
2018-02-07 07:37:34 | 3RD REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: | | | | PREVIOUS COMMENT NOT COMPLIED 3RD REQUEST SUBMIT | | CALCULATIONS FOR COMBUSTION AIR PER THE FBC-2014 FUEL | | GAS CODE SEC. 304. THE WATER HEATERS ARE THE ONLY | | DIRECT VENT GAS APPLIANCES PLEASE PROVIDE COMBUSTION | | CALC FOR KITCHEN COOKING APPLIANCES. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2017-07-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-07 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-07 |
Time |
10:53 |
Sent To |
|
|
Notes |
2017-07-07 11:09:44 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: | | | | PREVIOUS COMMENT NOT COMPLIED 2ND REQUEST5. SUBMIT | | CALCULATIONS FOR COMBUSTION AIR PER THE FBC-2014 FUEL | | GAS CODE SEC. 304. THE WATER HEATERS ARE THE ONLY | | DIRECT VENT GAS APPLIANCES PLEASE PROVIDE COMBUSTION | | CALC FOR KITCHEN COOKING APPLIANCES. | | | | NEW COMMENTS: | | | | 1. THE NOTE ON THE GAS RISER 11/2" G(GWH-2/399) IS THIS | | INDICATING 2 GWH AT 399 CFH THE PLAN ONLY SHOWS ONE | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 2. SHOW ALL PIPING FOR GWH ON RISER WITH SIZE AND | | LENGTH. PER WPB AMEND TO FBC 107.2.1 | | | | 3. PLEASE SHOW METER ON RISER. PER WPB AMEND TO FBC | | 107.2.1 | | | | 4. SHOW ANSUL VALVE ON RISER. PER WPB AMEND TO FBC | | 107.2.1 | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-03-01 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-01 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-01 |
Time |
16:43 |
Sent To |
|
|
Notes |
2017-03-01 16:49:32 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | GAS COMMENTS: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | 4. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | SEC. 402.4.1. | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | PSI. | | | | 7. PROVIDE SIZING TABLE BEING USED TO SIZE SYSTEM. WPB | | AMENDMENTS TO FBC SEC. 107.2.1 | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2018-04-17 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-04-17 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-03-13 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-02-09 |
Time |
|
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-01-10 |
Time |
10:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-09-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-09-07 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-06-06 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-05-02 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-05-02 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-04-28 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-04-04 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2017-04-04 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-01-26 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2017-06-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-06-26 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-06-26 |
Time |
15:36 |
Sent To |
|
|
Notes |
2017-06-26 15:36:34 | MU-2017-9292 | | EUC, $0 DUE | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-02-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-02-16 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-02-16 |
Time |
13:08 |
Sent To |
|
|
Notes |
2017-02-16 13:08:55 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED | | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | THAT FEES WERE PAID ARE TO BE SUBMITTED PRIOR TO PERMIT | | ISSUANCE | | | | 561-233-5025 FOR MORE INFORMATION | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2018-04-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-04-05 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-04-05 |
Time |
07:43 |
Sent To |
|
|
Notes |
2018-04-05 16:50:35 | MECHANICAL PROVISO. | | 4/5/18 | | | | REQUIRED SUBMITTALS: | | | | 1) WIND LOAD ENGINEERING FOR INSTALLATION OF ALL | | EXTERIOR MECHANICAL EQUIPMENT INCLUDING AC CONDENSERS | | AND FANS. | | | | 2) FLORIDA PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S | | FOR CONDENSER ANCHORING CLIPS, EXHAUST AND OUTDOOR AIR | | LOUVERS. | | | | 3) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | INSTRUCTIONS FOR THE GARAGE EXHAUST FANS, THE HONEYWELL | | GAS MONITORS AND CONTROLLER, THE EXHAUST DUCT | | FIREWRAPPING, FIRE DAMPERS, AND SMOKE DETECTORS. | | | | ALL SUBMITTALS SHALL BE REVIEWED AND APPROVED BY THE | | DESIGN PROFESSIONAL OF RECORD AND BEAR SHOP DRAWING | | APPROVAL STAMPS. | | | | 1) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS. | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | NOT SUBMITTED AT THE TIME OF THEAPPLICATION AND THAT | | ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | 2) DEFERRED SUBMITTAL. 2017 FBC 107.3.4.1 PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2018-02-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-02-09 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-01-30 |
Time |
11:58 |
Sent To |
I |
|
Notes |
2018-02-09 14:01:56 | 3RD REVIEW FBC-2014 MECHANICAL , ENERGY CONSERVATION | | CODES. | | WEST PALM BEACH AMENDMENTS TO THE FBC. | | PERMIT #16110061 | | 7/7/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE VENTILATION SYSTEM IN THE GOLF CART PARKING | | GARAGE WHERE THE BATTERIES ARE CHARGED IS STILL IN | | QUESTION. THE SUBMITTAL FROM CLUB CAR AND THE REVISED | | PLAN ARE NOT CLEARLY INDICATING THAT THE SYSTEM WILL | | PROVIDE CONTINUOUS VENTILATION THAT WILL LIMIT THE | | CONCENTRATION OF HYDROGEN TO 1.0 PERCENT OF THE VOLUME | | OF THE ROOM- SECTION 502.4.1. PROVIDE FURTHER EVIDENCE | | AND CALCULATIONS | | | | ACCORDINGLY. PLEASE NOTE THAT THE SENSORS SHALL ALSO BE | | CAPABLE OF DETECTING NO2 IN CONJUNCTION WITH CO2 PER | | SECTION 404.1 (2). | | | | 2) REFER TO SECTIONS 510.6.1 & 510.6.2: THE FIRE | | DAMPERS IN THE GARAGE EXHAUST DUCTS ARE PROHIBITED, AND | | THE DUCTS SHALL BE ENCLOSED IN FIRE-RESISTANT SHAFT | | CONSTRUCTION WHERE THEY PENETRATE THE FLOOR/CEILING | | SASSEMBLY, ASCEND UP THROUGH THE 1ST FLOOR AND ATTIC | | SPACE TO TERMINATION ABOVE THE ROOF. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-07-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-07-07 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-07-06 |
Time |
12:38 |
Sent To |
|
|
Notes |
2017-07-07 11:30:41 | 2ND REVIEW FBC-2014 MECHANICAL , ENERGY CONSERVATION | | CODES. | | WEST PALM BEACH AMENDMENTS TO THE FBC. | | PERMIT #16110061 | | 7/7/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS M0.1 & M1.1: REFER TO COMMENT #3 FROM THE 1ST | | REVIEW AND SECTION 404.2 MINIMUM VENTILATION FOR | | PARKING GARAGES. PLEASE PROVIDE EXHAUST CACULATIONS | | BASED ON A MINIMUM AIRFLOW RATE OF 0.05 CFMS PER SQ. | | FT. AND A MAXIMUM CAPABILITY OF 0.75 CFMS PER SQ. FT. | | PLACE A NOTE THAT THE SYSTEM WILL OPERATE CONTINUOUSLY | | NOT BELOW THE MINIMUM AIRFLOW RATE. | | | | 2) M1.1, DETAIL 2: PLEASE PROVIDE A WRITTEN NARRATIVE | | TO ACCOMPANY AND CLARIFY THE GAS MONITORING CONTROL | | SEQUENCE OF OPERATION. | | | | 3) M1.1: REFER TO COMMENT #9 FROM THE 1ST REVIEW AND | | SECTIONS 502.4 & 502.8. AS PREVIOUSLY REQUESTED | | INDICATE WHERE THE GOLF CART BATTERIES WILL BE STORED | | AND CHARGED AND PROVIDE CONTINOUS VENTILATION THAT WILL | | LIMIT THE CONCENTRATION OF HYDROGEN TO 1.0 PERCENT OF | | THE TOTAL VOLUME OF THE ROOM- SECTION 502.4.1. A) THE | | SUBMITTED DOCUMENT FROM "CLUB CAR" APPEARS TO BE JUST | | ONE PAGE OF A MULTI-PAGE DOCUMENT. PLEASE PROVIDE A | | COMPLETE SUBMITTAL WITH A REVIEW AND APPROVAL STAMP BY | | THE ENGINEER OF RECORD. B) THE FLOOR PLAN SHOWS ONLY | | TWO GAS SENSORS FOR THE ENTIRE AREA: PROVIDE | | MANUFACTURER'S SPECIFICATIONS TO VERIFY THE SPACINGS | | ARE ADEQUATE, AND NOTE THAT A SENSOR WILL BE REQUIRED | | IN THE BATTERY STORAGE ROOM. C) PLEASE PLACE A NOTE ON | | THE PLANS PURSUANT TO TABLE 403.3 FOOTNOTE B THAT NO | | EXHAUST AIR FROM THE PARKING GARAGE WILL BE | | RECIRCULATED TO OCCUPIED SPACES VIA AHU-1. | | | | 4) M1.1, M1.2, & M2.1- DETAIL 12: PROVIDE DUCT SMOKE | | DETECTORS IN THE RETURN AIR SYSTEMS OF AHU'S 1, 2, & 3- | | SECTION 606.2.1. PROVIDE SYMBOLS TO SHOW THE | | INSTALLATION LOCATIONS. | | | | 5) M1.2 & M1.3 & M1.3: NO REFERENCE TO THE MUA FAN(S) | | FOR THE HOODS ARE SHOWN ON THE MECHANICAL FLOOR PLANS | | AND NO EQUIPMENT SCHEDULES HAVE BEEN PROVIDED, OR FAN | | LOCATIONS SHOWN. | | | | 6) M1.2: THE 2X2' ACCESS PANEL FOR AHU-2 APPEARS TWO | | SMALL TO BE ABLE TO REMOVE AND REPLACE AHU-2, AND NO | | PANEL LOCATIONS ARE SHOWN FOR VAV BOXES AND FANS THAT | | ARE LOCATED ABOVE HARD CEILINGS- PLEASE SEE CODED NOTE | | #1 ON THE PLAN, AND SECTION 306.1 AND SHOW ALL PROPOSED | | PANEL LOCATIONS AND DIMENSIONS. | | | | 7) M1.1: PROVIDE THE CLEARANCE DISTANCE MEASUREMENT | | BETWEEN EXHAUST FANS EF-3A & 3B AND THE 24X12 O/A | | LOUVER. THE LOCATIONS DO NOT APPEAR TO BE IN COMPLIANCE | | WITH EITHER 401.4 OR 506.3.13.3. | | | | 8) M2.1 : PROVIDE THE WIND DESIGN CRITERIA USED TO | | ESTABLISH THE TIE DOWN DESIGN FOR THE CONDENSERS, AND | | SUBMIT A FL. PRODUCT APPROVAL OR MIAMI-DADE NOA FOR THE | | CLIP. PLEASE NOTE ALL SUBMITTALS SHALL BEAR THE SHOP | | DRAWING APPROVAL STAMP FROM THE EOR. | | | | 9) PLEASE PROVIDE A MECHANICAL ROOF PLAN SHOWING THE | | LOCATIONS OF OF EQUIPMENT, AND ALL MECHANICAL OR | | GRAVITY O/A INTAKE OPENINGS AND EXHAUST OUTLETS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-02-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-02-03 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-02-03 |
Time |
09:58 |
Sent To |
|
|
Notes |
2017-02-03 10:35:57 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #16110061 | | 2/3/17 | | | | 1) THE SUMMARY AC COOLING AND HEATING CALCULATIONS | | SHALL BEAR AN ELECTRONIC SIGNATURE AND SEAL BY THE | | ENGINEER OF RECORD- SECTION C403.2.1 EXCEPTION FBC-14 | | ENERGY CONSERVATION, AND SECTION 61G15-23.005 FLORIDA | | ADMINISTRATIVE CODE. | | | | 2) THE ENERGYGAUGE COMPLIANCE SUBMITTAL MUST BEAR THE | | CERTIFICATION SIGNATURES OF THE DESIGN PROFESSIONALS | | AND THE OWNER/AGENT ON PAGE 3, AND MUST BE | | ELECTRONICALLY SIGNED AND SEALED PER SECTION | | 61G15-23.005 FAC. | | | | 3) PROVIDE EXHAUST VENTILATION CALULATIONS FOR THE | | PARKING GARAGE, THE LOCKER ROOMS AND BATHROOMS, AND THE | | KITCHEN PER TABLE 403.3. A) INDICATE HOW MAKEUP AIR IS | | BEING PROVIDED FOR THE GARAGE AND LOCKER ROOM EXHAUST | | SYSTEMS. B) PROVIDE AIR BALANCE CALCULATIONS FOR BOTH | | FLOORS THAT INCLUDE ALL EXHAUST SYSTEMS. | | | | 4) ADVISORY: SEPARATE PERMITS AND PLANS ARE REQUIRED | | FOR THE KITCHEN EXHAUST SYSTEM, THE KITCHEN HOOD FIRE | | SUPPRESSION, AND THE WALK-IN COOLER/FREEZER. PLEASE | | PLACE A NOTE ON THE PLANS ACCORDINGLY. PLEASE NOTE THE | | FOLLOWING: A) THE HOOD EXHAUST FAN OUTLETS TERMINATING | | AT THE EXTERIOR WALL SHALL BE IN COMPLIANCE WITH | | 506.3.13.2. B) THE FANS MUST BE ANCHORED TO THE | | BUILDING TO WITHSTAND THE DESIGN WINDLOADS AND | | PRESSURES, AND INSTALLED IN A MANNER TO PREVENT WATER | | INTRUSION. | | | | 5) THE AC EQUIPMENT SCHEDULE ON M-3.1 INDICATES THAT AN | | ERV IS REQUIRED FOR AHU-1: REFER TO TABLE C403.2.6 AND | | SECTION C403.2.6 FBC-14 ENERGY CONSERVATION. | | | | 6) M-3.1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE VAV | | BOXES. | | | | 7) M-3.1: PROVIDE CONTROL SEQUENCES FOR ALL EXHAUST | | SYSTEMS. | | | | 8) M-1.1: LABEL THE AIR HANDLER, IDENTIFY AND LABEL THE | | SUPPLY DIFFUSERS AND RETURN GRILLS. | | | | 9) M-1.1: PROVIDE VENTILATION FOR THE BAG STORAGE, | | STORAGE, AND MAINTENANCE ROOMS- TABLE 403.3. PLEASE SEE | | SECTION 502 AND ALL APPLICABLE SUB-SECTIONS AND PROVIDE | | EXHAUST VENTILATION WHERE REQUIRED FOR ALL FUEL, OR | | BATTERY STORAGE ROOMS OR AREAS. PLEASE NOTE THAT A | | DETAILED LIST OF ALL HAZARDOUS MATERIALS AND THEIR | | QUANTITIES MAY BE REQUIRED PER SECTION414.1.3 FBC-14 | | BUILDING. | | | | 10) M-1.1 & M-1.2: FIRE DAMPERS ARE REQUIRED WHERE THE | | 32X20, 22X14, AND 3" DUCTS PENETRATE THE FLOOR/CEILING | | ASSEMBLY- SECTION 607.6.2. | | | | 11) M-1.1 & M-1.2: THE PLANS ARE INDICATING AIR FROM | | THE GROUND FLOOR GARAGE WILL BE RECIRCULATED INTO THE | | OCCUPIED AREAS ON THE FIRST FLOOR WHICH IS PROHIBITED | | BY FOOTNOTE B, TABLE 403.3. | | | | 12) M-1.1: PROVIDE THE EXHAUST OUTLET CLEARANCE | | DISTANCES AS OUTLINED IN SECTION 501.3.1. | | | | 13) M.1-1: CORRECT THE DUCT HEIGHT NOTE TO INDICATE | | MINIMUM 7'0" CLEARANCE FROM FINISHED GARAGE FLOOR TO | | BOTTOM OF THE DUCT- SECTION 406.4.1 FBC-14 BUILDING. | | | | 14) M-1.2: THE PLAN DOES NOT APPEAR TO SHOW ANY EXHAUST | | VENTILATION FOR THE MEN'S AND WOMEN'S LOCKER ROOMS | | WHICH IS REQUIRED BY TABLE 403.3. PLEASE SEE FOOTNOTE G | | AS IT APPEARS RECIRCULATION FROM THOSE AREAS IS | | EXCEEDING THE ALLOWABLE MAXIMUM. | | | | 15) M-1.2: THE PLAN APPEARS TO SHOW TWO L4 DIFFUSERS IN | | THE RECEPTION ROOM CONNECTED TO TWO B RETURN GRILLS IN | | THE GOLF-PRO OFFICE. | | | | 16) M-1.2: PROVIDE ALL FLEX DUCT SIZES. | | | | 17) M-1.2: INDICATE HOW ACCESS WILL BE PROVIDED FOR | | MAINTENANCE AND REPLACEMENT OF AHU'S 2 & 3- SECTION | | 306.1. | | | | 18) M-1.2: PROVIDE ENGINEERED DETAILS FOR TIE DOWN OF | | THE AC CONDENSER UNITS- SECTION 301.15. | | | | 19) SUBMIT TWO COPIES OF A VALID FL.PRODUCT APPROVAL | | AND/OR MIAMI-DADE NOA FOR THE LOUVERS- RULE 9N-B FAC. | | | | 20) A COMPLETE REVIEW OF THE PROPOSED PROJECT CANNOT BE | | PERFORMED AT THIS TIME DUE TO A LACK OF INFORMATION. IN | | ORDER TO EXPEDITE THE SECOND REVIEW PLEASE PROVIDED A | | DETAILED NARRATIVE THAT ITEMIZES ALL CORRECTIONS MADE | | TO THE PLANS. PLEASE NOTE ADDITIONAL COMMENTS MAY | | FOLLOW THIS INITIAL REVIEW. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2018-04-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-04-07 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-04-06 |
Time |
17:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-02-07 |
Time |
07:37 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-02-06 |
Time |
16:07 |
Sent To |
|
|
Notes |
2018-02-07 09:17:07 | 3RD REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. SHT. P-4.2 THE DETAIL FOR THE GREASE INTERCEPTOR | | SHALL MATCH THE CITY OF WEST PALM BEACH PUBLIC WORKS | | DEPT STANDARD DETAIL GS-7 FOR CONCRETE GREASE | | INTERCEPTORS. | | | | 2. SHT. P-1.0 IS MISSING THE DIGITAL SIGNATURE | | | | 3. SHTS. P-1-1, P-3-2, P-4-3 THE DOCUMENTS HAVE BEEN | | MODIFIED AFTER DIGITAL SIGNATURE WAS APPLIED. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-07-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-07-07 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-07-07 |
Time |
08:35 |
Sent To |
|
|
Notes |
2017-07-07 11:39:16 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. SHT P.3.3 THE TRAP FOR THE MOP SINK IS SHOWN ON THE | | SANITARY LINE IT SHALL BE ON THE GREASE RISER PLEASE | | CLARIFY. PER FBC PL 1003.3.1 | | | | 2. WHAT DOES FBO STAND FOR ON THE FLOOR TROUGH AND | | MOPSINK LOCATED ON THE GREASE RISER. PER WPB AMEND TO | | FBC 107.2.1 | | | | 3. SHT. P.0.2 UNDER THR PLUMBING SPECIFICATIONS 1.02 | | HAS THE WRONG CODE YEAR WE ARE UNDER THE 2014 5TH | | EDITION PLEAS CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 4. SHT P.3.1 WATER RISER PLEASE IDENTIFY HOT WATER | | RETURN PIPING. PER WPB AMEND TO FBC 107.2.1 | | | | 5. SHT. P.1.1 IS LABELED AS BASEMENT LEVEL BUT THE PLAN | | SHOWS THE MAIN FLOOR ALSO MAKES IT VERY DIFFICULT TO | | DISCERN THE PLUMBING THE DIFFERENT LEVELS PLEASE | | SEPARATE. PER WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-03-01 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-03-01 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-03-01 |
Time |
13:23 |
Sent To |
|
|
Notes |
2017-03-01 16:42:48 | 1ST REVIEW | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER LL | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES | | BUILDING DIVISION | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | 1. SHT. P-3-3 PLEASE SEPARATE THE ISOMETRIC DRAWINGS , | | THE BASEMENT FROM THE 1ST FLOOR AND THE GREASE ALL | | SEPARATE OR EXPANDED SO THAT THE DIFFERENT LAYERS ARE | | NOT ON TOP OF EACH OTHER. PER WPB AMEND TO FBC 107.2.1 | | | | 2. TRAP PRIMERS ARE REQUIRED ON ALL FLOOR DRAINS SHOW | | TRAP PRIMERS ON THE ISOMETRIC DRAWING OR PUT A NOTE ON | | THE PLAN. PER FBC PL 1002.4 AND WPB AMEND TO FBC | | 107.2.1 | | | | 3. PROVIDE ISOMETRIC DRAWINGS FOR THE STORM SHOWING THE | | GRADE OF THE PIPE AND THE SQFT BEING DRAINED BY EACH | | DRAIN. WPB AMEND TO FBC 107.3.5.1.3(13) | | | | 3. A DRAIN PAN IS REQUIRED FOR WATER HEATER NOT SHOWN | | ON DETAIL SHT P-4-3. PER FBC PL 504.7 | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | |
|
|
Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
Rev No |
1 |
Status |
P |
Date |
2018-04-07 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-04-07 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-04-07 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
N |
Date |
2017-07-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-07-05 |
Time |
06:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-07-05 |
Time |
06:14 |
Sent To |
|
|
Notes |
2017-10-04 06:15:20 | A SEPARATE ROOF PERMIT IS REQUIRED. THE ROOF PRODUCT | | APPROVAL INDICATING THE ASSEMBLY PROPOSED AND | | ENGINEERING, IF APPLICABLE, IS TO BE SUBMITTED. THE | | ROOF PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL. ROOF PERMIT REQUIRED PRIOR | | TO ROOF WORK COMMENCEMENT. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-03-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-03-10 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-03-10 |
Time |
15:06 |
Sent To |
|
|
Notes |
2017-03-10 15:06:09 | ROOF AND OTHER PRODUCT APPROVALS NOT SUBMITTED | | SEE BUILDING COMMENTS | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2018-04-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-10 |
Time |
07:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-10 |
Time |
07:28 |
Sent To |
|
|
Notes |
2018-04-10 07:29:12 | RECEIVED M-1-3 AND MK-4-1 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2018-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-07 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-07 |
Time |
14:05 |
Sent To |
|
|
Notes |
2018-04-07 14:05:19 | SHEETS 085 M-1-3 AND 088 MK-4-1 HAVE UNSIGNED CHANGES | | AFTER THE LAST SIGNATURE. PLEASE SEND THESE TWO SHEETS | | PROPERLY SIGNED AND SEALED VIA EMAIL TO [email protected] | | WITH "16110061 SIGNATURE FILES" IN THE SUBJECT LINE. | | | | IF NEW SHEETS ARE UPLOADED TO PROJECTDOX, A NEW | | MECHANICAL REVIEW IS REQUIRED. THEREFORE, PLEASE | | RESOLVE WITH ME VIA EMAIL. | | | | 561-805-6724 IF YOU WISH TO DISCUSS. | | SAMANTHA M. HILL | | | | | | | 2018-04-07 11:02:45 | 4/6/18 DIG SIG ON PLUMB SHT OK/GPJ |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-02-05 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-02-05 |
Time |
10:03 |
Sent To |
|
|
Notes |
2018-02-07 09:18:31 | SHT. P-1.0 IS MISSING THE DIGITAL SIGNATURE | | SHTS. P-1-1, P-3-2, P-4-3 THE DOCUMENTS HAVE BEEN | | MODIFIED AFTER DIGITAL SIGNATURE WAS APPLIED. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | 2018-02-05 10:37:42 | SEE BUILDING REVIEW FOR COMMENTS REGARDING DIGITAL | | SIGNATURE ISSUES | | A NEW REVIEW IS REQUIRED FOR NEW SHEETS UPLOADED IN | | NEXT CYCLE | | | | DIGITAL SIGNATURES REVIEWED (S.HILL) | | | | A SHEETS - OK | | S SHEETS - F; SEE BUILDING REVIEW | | FP - OK | | MEP - OK | | CIVIL - PAPER ORIGINAL WAS PROVIDED | | SOILS REPORT - OK | | ENERGY CALCS - OK | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2017-07-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-07-02 |
Time |
06:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-10-04 |
Time |
06:15 |
Sent To |
|
|
Notes |
2017-06-30 06:43:07 | SIGNATURE REVIEW TO BE DONE AFTER RESUBMITTAL | | | | 6/30/17 SOILS REPORT OK (SH) | | CIVIL SHEETS OK - ORIGINALS ON FILE WITH STRUCTURE | | PERMIT 17010998 | | HOLLOW CORE DELEGATED ENGINEERING NOT SIGNED AND SEALED | | (SEE BUILDING REVIEW) | | | | | | | | | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2017-03-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-03-09 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-03-09 |
Time |
17:41 |
Sent To |
|
|
Notes |
2017-02-16 13:11:43 | SEE BUILDING REVIEW FOR COMMENTS REGARDING DIGITAL | | SIGNATURE ISSUES | | | | | | DIGITAL SIGNATURES REVIEWED (S.HILL) | | | | A SHEETS - FAIL, SEE BUILDING COMMENTS | | SOILS REPORT - OK | | ENERGY CALCS - OK | | S SHEETS - SHEETS MUST BE DIGITALLY SIGNED AND SEALED; | | ENGINEER MAY NOT SIGN THE PLAN AS THIS METHOD DOES NOT | | COMPLY WITH FAC61G15. CONTACT ME OR FBPE TO DISCUSS | | JAMES MULLEN PE PROVIDED CERTIFICATE FOR FBC COURSE, | | EMAILED FBPE TO REQUEST THAT WEBSITE BE UPDATED | | CIVIL PAGES NOT SIGNED AND SEALED; FAILED, SEE BUILDING | | COMMENTS | | | | | | | 2016-11-16 14:05:10 | 11/16/16 - CIVIL DRAWINGS WILL BE FOR REFERENCE ONLY - | | DOES NOT NEED DIGITAL SIGNATURE. LEM |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
2 |
Status |
N |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-02-05 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-02-05 |
Time |
10:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2017-03-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-03-09 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-03-09 |
Time |
12:29 |
Sent To |
|
|
Notes |
2017-03-09 12:35:20 | ****CORRECTIONS**** | | REVISED 3/21/17 | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 3/21/17 - PER KEN CONRAD, IF THIS BUILDING IS NOT | | CLASSIFIED AS A THRESHOLD BUILDING, A RESIDENT | | INSPECTOR IS NOT REQUIRED. A PRE-CONSTRUCTION MEETING | | IS REQUIRED. A RESIDENT INSPECTOR IS SUGGESTED IF | | APPLICANT HAS A TIGHT CONSTRUCTION SCHEDULE, BUT NOT | | REQUIRED. | | | | ***************************************************** | | IT IS NOT CLEAR WHETHER THIS IS A THRESHOLD BUILDING | | (SEE BUILDING COMMENTS REGARDING OCCUPANT LOAD), AND | | REQUIRES A SPECIAL INSPECTOR, OR, IF IT IS NOT A | | THRESHOLD BUILDING MAY REQUIRE A RESIDENT INSPECTOR, | | FBC 110.3.7, 110.3.9. | | | | THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN THE | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | PERSONS. | | A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | WITH THE PERMITTED DOCUMENTS. | | | | B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | PLACE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL | | INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER | | INFORMATION BEFORE THE PERMIT MAY BE ISSUED. | | | | C) THRESHOLD BLDG., REQUIRED STATEMENT: W.P.B. | | AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | OR ENGINEER OF RECORD CONTAIN THE STATEMENT REQUIRED BY | | FLORIDA STATUTE 553.79. THE ARCHITECT'S PLAN INCLUDES | | THE STATEMENT ON PAGE A001; ENGINEER'S PLAN NEEDS | | STATEMENT TO BE ADDED (OR ADVISE WHERE THIS CAN BE | | LOCATED). | | | | D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | MEETING THE ABOVE CRITERIA. | | | | E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | FOR THIS TYPE OF CONSTRUCTION. | | | | F) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, | | PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING | | ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE | | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR | | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN | | COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR | | THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE | | IN BLACK & WHITE. | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD | | BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS | | CONCERNING SPECIAL INSPECTORS. | | | | G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES, | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | DOCUMENTS BY THE CONTRACTOR. | | | | H) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | I) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES | | FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER | | HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE | | MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR | | WALLS AND CEILINGS. | | | | SI AGREEMENT/RESIDENT INSPECTOR AGREEMENT, G&P FOR | | SPECIAL INSPECTORS SENT VIA EMAIL TO | | [email protected] ON 3/9/17. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-04-17 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2018-04-17 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2018-04-17 |
Time |
14:00 |
Sent To |
|
|
Notes |
2018-04-17 14:11:45 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 04.17.2018 | | PERMIT NO.: 16110061 | | ___________________________________________ | | | | REVIEW STATUS: PASSED WITH PROVISOS | | ___________________________________________ | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. PRIOR TO THE ISSUANCE OF A CO, ALL SITE | | IMPROVEMENTS, LANDSCAPING, PARKING, ETC. FOR PHASE I | | SHALL BE COMPLETED. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-09-07 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-09-07 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-09-07 |
Time |
11:48 |
Sent To |
|
|
Notes |
2017-09-07 11:53:05 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 09.07.2017 | | PERMIT NO.: 16110061 | | ___________________________________________ | | | | REVIEW STATUS: PASSED WITH PROVISOS | | ___________________________________________ | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. PRIOR TO THE ISSUANCE OF A CO, ALL SITE | | IMPROVEMENTS, LANDSCAPING, PARKING, ETC. FOR PHASE I | | SHALL BE COMPLETED. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-04-03 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2017-04-03 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-04-03 |
Time |
16:06 |
Sent To |
|
|
Notes |
2017-04-03 16:07:28 | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLANS DO NOT MATCH THAT WHICH HAS BEEN APPROVED | | THROUGH THE BANYAN CAY PLANNED DEVELOPMENT. AMENDMENT | | SHALL BE SUBMITTED TO AND APPROVED BY THE PLANNING | | DIVISION PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
|