Plan Review Details - Permit 16100758
Plan Review Stops For Permit 16100758
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-01-26 Cont ID  
Sent By shill Date 2017-01-26 Time 07:49 Rev Time 0.00
Received By shill Date 2017-01-26 Time 07:46 Sent To  
Notes
2017-01-26 07:50:22PROVISO
 ELEVATION CERTIFICATE REQUIRED AFTER TRAILER IS SET
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-11-01 Cont ID  
Sent By shill Date 2016-11-01 Time 17:15 Rev Time 0.00
Received By shill Date 2016-11-01 Time 16:49 Sent To  
Notes
2016-11-01 17:27:25****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. REVISE SITE PLAN TO SHOW PROPOSED LOCATION OF
 CONSTRUCTION TRAILER AND REQUIRED RAMP AND STAIRS, FBC
 107.
  
 2. ALTHOUGH EXEMPT FROM FLORIDA BUILDING CODE PER
 FLORIDA STATUTE, THIS DOES NOT APPEAR TO BE EXEMPT FROM
 ACCESSIBILITY. A RAMP IS REQUIRED. THIS MAY BE A
 PROVISO ITEM UPON REQUEST. IF APPLICANT FEELS THEY ARE
 EXEMPT FROM ACCESSIBILITY, PLEASE CONTACT ME TO
 DISCUSS. FBC 5TH EDITION ACCESSIBILITY 402.
  
 3. ALTHOUGH EXEMPT FROM FLORIDA BUILDING CODE PER
 FLORIDA STATUTE, THIS STRUCTURE IS NOT EXEMPT FROM NFIP
 (AKA FEMA) REQUIREMENTS. CLARIFY THE HEIGHT OF THE
 FOUNDATION FOR THIS STRUCTURE. IF THE FOUNDATION WILL
 BE SUBJECT TO FLOOD LOADS (INSTALLED BELOW 14 FT), THE
 FOUNDATION IS TO BE DESIGNED TO RESIST FLOOD LOADS FBC
 1622, CITY OF WEST PALM BEACH MUNICIPAL CODE 94-546.
 THERE IS A NOTE ON THE PLAN WHICH STATES THAT THIS
 CANNOT BE SUBJECT TO WAVE ACTION, BUT DOES NOT STATE
 THAT IT WILL RESIST FLOOD LOADS. CLARIFICATION IS
 NEEDED. A LETTER FROM THE ENGINEER WILL SUFFICE.
  
 4. SEE NFIP REVIEW.
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-01-27 Cont ID  
Sent By vperez Date 2017-01-27 Time 13:02 Rev Time 0.00
Received By vperez Date 2017-01-27 Time 13:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-12-02 Cont ID  
Sent By vperez Date 2016-12-02 Time 06:16 Rev Time 0.00
Received By vperez Date 2016-12-02 Time 06:16 Sent To  
Notes
2016-12-02 06:19:18PLEASE ADDRESS ZONING AND BUILDING COMMENTS FOR
 ELECTRICAL APPROVAL.
 ALSO, PLEASE PROVIDE AN ELECTRICAL RISER DIAGRAM
 SHOWING THE LOCATION OF SERVICE FPL, AND SERVCICE
 DISCONNECT/CONDUCTOR FEEDING THE TRAILER PANEL BOARD
 AND GROUDING ELECTRODE SCHEME. FBC 107.3.5
  
 VAL PEREZ
 *6717

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-01-23 Cont ID  
Sent By pleduc Date 2017-01-23 Time   Rev Time 0.00
Received By pleduc Date 2017-01-20 Time 16:46 Sent To  
Notes
2017-01-23 10:31:21THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: PARENTHESIS
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) FIRE HYDRANT AND FIRE LAINE SHALL BE INSTALLED PER
 NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE
 SERVICE MAINS AND THEIR APPURTENANCES, 2010 EDITION.
  
  
 2) ALL UNDERGROUND WORK SHALL BE INSPECTOR BY A FIRE
 INSPECTOR PRIOR TO COVER OVER.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-02-06 Cont ID  
Sent By tklarge Date 2017-02-06 Time 10:21 Rev Time 0.00
Received By tklarge Date 2017-01-17 Time 11:32 Sent To  
Notes
2017-01-18 11:32:29B14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-12-02 Cont ID  
Sent By vperez Date 2016-12-02 Time 06:19 Rev Time 0.00
Received By vperez Date 2016-12-02 Time 06:19 Sent To  
Notes
2016-10-26 10:06:18B14

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2016-11-01 Cont ID  
Sent By ccole Date 2016-11-01 Time 09:43 Rev Time 0.00
Received By ccole Date 2016-11-01 Time 09:42 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2017-01-26 Cont ID  
Sent By shill Date 2017-01-26 Time 07:50 Rev Time 0.00
Received By shill Date 2017-01-26 Time 07:50 Sent To  
Notes
2017-01-26 07:51:37PROVISO
 ELEVATION CERTIFICATE IS REQUIRE AFTER TRAILER IS SET
 PROPOSED DFE FOR FINISHED FLOOR IS 17.33'
 BOTTOM OF FOOTING IS AT 14.88'

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2016-11-01 Cont ID  
Sent By shill Date 2016-11-01 Time 16:55 Rev Time 0.00
Received By shill Date 2016-11-01 Time 16:55 Sent To  
Notes
2016-11-01 17:04:20****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THIS PARCEL IS LOCATED IN SPECIAL FLOOD HAZARD AREA
 A9, BFE 13 FEET (FIRM 120229 0020 B). ALL EQUIPMENT
 SERVICING THE STRUCTURE AND THE FINISHED FLOOR OF THE
 STRUCTURE ARE TO BE AT A MINIMUM OF 14 FT (13 BFE PLUS
 1 FT FREEBOARD PER ORDINANCE).
  
 2. REVISE PLAN TO SHOW PROPOSED FINISHED FLOOR
 ELEVATION, CITY OF WEST PALM BEACH MUNICIPAL CODE
 94-546.
  
 3. REVISE PLAN TO SHOW ALL EQUIPMENT SERVICING THE
 BUILDING, CITY OF WEST PALM BEACH MUNICIPAL CODE
 94-546.
  
 4. A "BUILDING UNDER CONSTRUCTION" ELEVATION
 CERTIFICATE IS REQUIRED PRIOR TO CONCRETE POUR /
 SETTING OF TRAILER. A "FINISHED CONSTRUCTION" ELEVATION
 CERTIFICATE IS REQUIRED PRIOR TO FINAL INSPECTION. THIS
 PERMIT WILL BE ISSUED WITH PROVISO.
  
 FAILURE TO PROVIDE BOTH ELEVATION CERTIFICATES WILL
 DIRECTLY AFFECT THE CITY'S COMMUNITY RATING SYSTEM.
 PLEASE FEEL FREE TO CONTACT ME TO DISCUSS IF YOU WOULD
 LIKE MORE INFORMATION.
  
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2017-02-06 Cont ID  
Sent By tklarge Date 2017-02-06 Time 10:20 Rev Time 0.00
Received By tklarge Date 2017-02-06 Time 10:05 Sent To  
Notes
2017-02-06 10:20:53PLUMBING APPROVED BY G.JOHNSON ON 11/15/16.TKL.

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-11-15 Cont ID  
Sent By gjohnson Date 2016-11-15 Time 11:04 Rev Time 0.00
Received By gjohnson Date 2016-11-15 Time 11:04 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2017-02-01 Cont ID  
Sent By eschneid Date 2017-02-01 Time 09:26 Rev Time 0.25
Received By eschneid Date 2017-02-01 Time 09:26 Sent To  
Notes
2017-02-01 09:28:51FAILED
  
 1) REPEAT COMMENT: THE SITE PLAN SHALL SHOW THE STAIRS.
  
 2) REPEAT COMMENT: THE SITE PLAN SHALL SHOW PARKING FOR
 THE TRAILER AT A RATIO OF 1 SPACE PER 300 SQUARE FEET.
 THE FINAL SITE PARKING SPACES ON THE SOUTH SIDE OF THE
 SITE DO NOT MEET THIS REQUIREMENT AS THEY ARE NOT AT
 THE TRAILER.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 1 Status F Date 2016-11-28 Cont ID  
Sent By eschnide Date 2016-11-28 Time 14:28 Rev Time 0.25
Received By eschneid Date 2016-11-28 Time 14:28 Sent To  
Notes
2016-11-28 14:40:14FAILED
  
 1) THE SITE PLAN SHALL SHOW THE STAIRS AND RAMPS, IF
 REQUIRED.
  
 2) THE SITE PLAN SHALL SHOW PARKING FOR THE TRAILER AT
 A RATIO OF 1 SPACE PER 300 SQUARE FEET. PLEASE NOTE
 THAT IF ADA ACCESSIBILITY IS REQUIRED FOR THE TRAILER,
 THEN AT LEAST ONE ADA COMPLIANT PARKING SPACE, WITH
 ACCESS AISLE, SHALL BE PROVIDED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.