Plan Review Details - Permit 16100450
Plan Review Stops For Permit 16100450
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-11-28 Cont ID  
Sent By jwitmer Date 2016-11-28 Time 11:41 Rev Time 0.00
Received By jwitmer Date 2016-11-28 Time 11:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-24 Cont ID  
Sent By jwitmer Date 2016-10-24 Time 07:28 Rev Time 0.00
Received By jwitmer Date 2016-10-24 Time 07:09 Sent To  
Notes
2016-10-24 07:38:50BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16100450
 ADD: 5200 ASHLEY RIVER ROADS
 CONT: LENNAR HOMES
 TEL: 954-533-5299X1
 E-MAIL: SMAKSYM@ GOVERNMENTPROCESS.COM
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: MON. OCT. 24/2014
 ACTION: DENIED
  
 1) THE SITE PLAN AND SHEET 001ARCH SHOW THE LOCATION OF
 THE TRASH COMPACTOR . THE SUBMITTED COMPACTOR SPECS THE
 UNIT HIGHLIGHTED IS A 25 YD. DUMPSTER THE VERTICAL
 DISTANCE TO THE TOP OF THE DUMPSTER IS 48 INCHES, DOES
 NOT MEET THE REQUIREMENTS OF REACH RANGES FOR A FORWARD
 OR SIDE APPROACH. SEE 2014 FBC-ACCESSIBILITY CODE
 308.1.
  
 2) WIND LOAD SHEETS BY ENG. BRADLEY J. CASH P. E. ARE
 NOT SIGNED NOR SEALED. 61G15-23.005 PROCEDURES FOR
 SIGNING AND SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 3) WIND LOAD SHEETS BY ENG. BRADLEY J. CASH P. E. DO
 NOT COMPLY WITH 61G15-23.002(2) FL. ADMIN. CODE. A
 COVER SHEET OR INDEX SHEET FOR ENGINEERING
 SPECIFICATIONS MAY BE USED AND THAT SHEET MUST BE
 SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION &
 PREPARATION OF EACH SECTION OF THE ENGINEERING
 SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER
 SHEET OR INDEX LISTING HOW MANY PAGES ARE COVERED UNDER
 THE COVER SHEET OR INDEX SHEET.
  
 4) WIND LOAD SHEETS BY ENG. BRADLEY J. CASH P. E.
 INDICATE A VULT OF 160 MPH WITH BUILDING IMPORTANCE
 FACTOR II AND RISK FACTOR 1. DISCREPANCY IN THE PLAN
 PLEASE CORRECT. ASCE 7-10 FOR STRUCTURES WITH AN
 IMPORTANCE FACTOR II, FIGURE 26.5-1A INDICATES A WIND
 DESIGN VULT OF 170. PLEASE CORRECT THE WIND ANALYSIS.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-11-07 Cont ID  
Sent By vperez Date 2016-11-07 Time 14:26 Rev Time 0.00
Received By vperez Date 2016-11-07 Time 14:26 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2016-11-30 Cont ID  
Sent By mgonzale Date 2016-11-30 Time   Rev Time 1.00
Received By mgonzale Date 2016-11-30 Time   Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-30 Cont ID  
Sent By lmarchan Date 2016-11-30 Time 13:53 Rev Time 0.00
Received By lmarchan Date 2016-11-23 Time 11:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-15 Cont ID  
Sent By cpuell Date 2016-11-15 Time 18:50 Rev Time 0.00
Received By cpuell Date 2016-10-20 Time 12:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2016-11-28 Cont ID  
Sent By jwitmer Date 2016-11-28 Time 11:41 Rev Time 0.00
Received By jwitmer Date 2016-11-28 Time 11:41 Sent To  
Notes
2016-11-28 11:43:14PAPER WIND LOAD CALCULATION FOR LIGHT POLES AND DEPTH
 EMBEDMENT SIGNED AND SEALED. JW
2016-11-18 14:15:3311/17/16 RECEIVED SIGNED AND SEALED LIGHT POLE CALCS,
 ROUTED TO JWITMER. LEM

Review Stop Z ZONING
Rev No 1 Status P Date 2016-10-27 Cont ID  
Sent By rcaranci Date 2016-10-27 Time 08:52 Rev Time 0.00
Received By rcaranci Date 2016-10-27 Time 08:52 Sent To ENG-P
Notes
***NONE***