Plan Review Details - Permit 16100404
Plan Review Stops For Permit 16100404 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-11-17 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-11-17 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-11-17 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-10-27 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-10-27 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-10-27 |
Time |
14:07 |
Sent To |
|
|
Notes |
2016-10-27 14:55:31 | 2ND REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | 1] KEN ANGELOCCI, ACCORDING TO MY CONVERSATION WITH | | PHILL PETTY OUR CHEIF ELECTRICAL INSPECTOR NO SPECIAL | | PERMISSION WILL BE GRANTED THEREFORE YOU WOULD HAVE TO | | UPGRADE THE SERVICE TO INCLUDE MAINS AS STATED IN NEC | | 230.72 (ALL MAINS MUST BE GROUPED). | | | | 2] SEMI-ADDRESSED, MISSING LABEL TO EACH METER | | ENCLOSURE IDENTIFYING THE UNIT # IT SERVES. | | | | 3] COMPLIED. | | | | 4] COMPLIED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-10-20 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-10-20 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-10-20 |
Time |
15:11 |
Sent To |
|
|
Notes |
2016-10-20 15:21:11 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | 1] CLARIFY IF EACH METER ENCLOSURE HAS A MAIN | | DISCONNECT ? ALL MAINS MUST BE GROUPED AT THE SERVICE | | PER NEC 230.72 | | | | 2] SHOW EXISTING SERVICE WIRE AND CONDUIT SIZES ON THE | | RISER, IDENTIFY AMPERE RATING OF EXISTING EQUIPMENT AND | | LABEL EACH DISCONNECT, PROVIDE A SITE SPECIFIC FLOOR | | PLAN INDICATING THE LOACTION OF EACH PANEL. | | FBC-107.3.5.3 | | | | 3] MISSING 2 SMALL APPLIANCE VA LOADS ON THE | | CALCULATION, ASWELL AS THE WASHER CIRCUIT. IF THE | | BUILDING HAS A COMMON LAUNDRY PLEASE SPECIFY ON THE | | CALCS. NEC 220.52(A)&(B) | | | | 4] ACCORDING TO NEC 220.82 OPTIONAL FEEDER AND SERVICE | | LOAD CALCULATIONS ONLY APPLY TO 120-240 VOLTS 3 WIRE | | CONDUCTORS WITH AN AMPACITY OF 100 AMP OR GREATER. | | ( YOUR LOAD SIZE IS 70 AMPS THEREFORE YOU MUST USE THE | | STANDARD METHOD IN ACCORDANCE WITH NEC 220 PART 3 ) | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-11-17 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-11-17 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-11-10 |
Time |
11:50 |
Sent To |
|
|
Notes |
2016-11-14 11:50:58 | RESUB ROUTED TO MVALDES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-10-27 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-10-27 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-10-25 |
Time |
10:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-10-20 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-10-20 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-10-17 |
Time |
11:16 |
Sent To |
|
|
Notes |
2016-10-18 11:17:03 | ELEC <5K |
|
|
|