Plan Review Stops For Permit 16100387 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-12-28 |
Time |
18:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-12-28 |
Time |
17:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-11-30 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-11-29 |
Time |
16:58 |
Sent To |
|
|
Notes |
2016-11-29 19:12:32 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) IN ORDER TO PROVIDE VENTILATION TO THE THE SINGLE | | ASSEMBLY ROOF SYSTEM, A CONTINOUS SOFFIT VENT WOULD BE | | REQUIRED. FBC-R806.1 | | | | 2) THE SINGLE ASSEMBLY ROOF SYSTEM HAS 2 X 8 RAFTERS, | | WHICH WILL HAVE A SPACE OF 7.25 INCHES. THIS WOULD NOT | | BE ENOUGH SPACE FOR THE R-30 INSULATION AND A ONE INCH | | AIR SPACE. FBC-R 806.3 | | | | 3) THE SIGNED AND SEALED ENHANCED FASTENING | | CALCULATIONS FOR THE TAMKO MODIFIED ROOF SYSTEM DO NOT | | SPECIFY THE NOA PAGE NUMBER, THE SYSTEM TYPE OR TYPE OF | | FASTENERS THAT WILL BE USED. THERE ARE TWO PAGES IN THE | | NOA FOR SYSTEMS WITH NON-INSULATED DECKS WHICH HAVE A | | MAXIMUM DESIGN PRESSURE OF -60PSF. HOWEVER, NEITHER ONE | | OF THEM HAS FASTENER SPACING OF 11" ON CENTER. NOTE: | | OPTION #1 ON PAGE 13 USES RING SHANK NAILS AND TIN CAPS | | WITH A MAXIMUM DESIGN PRESSURE OF -52.5 PSF. | | | | 4) THE MECHANICAL PLANS SHOW DUCT WORK IN AN ATTIC. THE | | ADDITION HAS A SINGLE ASSEMBLY ROOF WITH NO ROOM FOR | | DUCTS. COORDINATE THE ARCHITECTURAL PLANS WITH THE | | MECHANICAL PLANS TO ADDRESS THIS ISSUE. FBC 107.2.1 | | | | 5) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2016-10-24 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-10-24 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-10-24 |
Time |
09:09 |
Sent To |
|
|
Notes |
2016-10-24 09:51:00 | 1ST REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | PASSED WITH THE FOLLOWING PROVISO'S (RED-LINED ON | | PLANS) | | | | 1] AFCI PROTECTION REQUIRED PER FBC-R SEC E3902.12. | | 2] CARBON MONOXIODE ALARMS REQUIRED IN ACCORDANCE WITH | | FBC-R SEC 315. | | 3] SMOKE ALARMS SHALL BE 3' AWAY FROM AC & BATH AS | | STATED IN NFPA 72 SEC 29.8.3.4. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-12-28 |
Time |
18:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-12-07 |
Time |
14:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-11-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-11-30 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-10-17 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2017-01-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-01-04 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-01-04 |
Time |
11:07 |
Sent To |
|
|
Notes |
2017-01-04 11:08:10 | MU-2017-73, NO FEES WERE DUE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-11-29 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-11-29 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2016-12-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-12-28 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-12-28 |
Time |
17:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2016-11-29 |
Time |
18:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2016-11-29 |
Time |
17:24 |
Sent To |
|
|
Notes |
2016-11-29 18:02:00 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY MECHANICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THERE APPEAR TO BE SOME ERRORS IN THE ENERGY FORMS. | | THE PLANS FOR THE ADDITION SPECIFY A ONE FOOT OVERHANG | | AND THE FORMS LIST A TWO FOOT OVERHANG. THE PLANS SHOW | | A FLAT SINGLE ASSEMBLY ROOF ON THE ADDITION WITH A | | MODIFIED BITUMEN ROOF SYSTEM AND THE ENERGY FORMS | | SPECIFY A HIP ROOF WITH A FULL ATTIC AND COMPOSITE | | SHINGLES. ALL OF THE WINDOWS IN THE ADDITION FACE EAST | | AND THE FORMS LIST ONE FACING NORTH. PLEASE MAKE SURE | | THAT THE INFORMATION LISTED IN THE FORMS MATCH THE | | PLANS, FBC ENERGY CONSERVATION SECTION 405 | | | | 2) THE MECHANICAL PLANS SPECIFY THAT THE DUCTWORK WILL | | BE IN THE CEILING. THE PLANS SPECIFY A SINGLE ASSEMBLY | | FLAT ROOF AND DO NOT SHOW ANY SOFFITS FOR THE DUCTWORK. | | COORDINATE THE MECHANICAL WITH THE ARCHITECTURAL PLANS. | | FBC 107.2.1 | | | | 3) THE EQUIPMENT SIZING CALCULATIONS INDICATE THAT A | | ONE TON COOLING UNIT IS ADEQUATE. JUSTIFY WHY A 1.5 TON | | IS PROPOSED. THE ACTUAL TOTAL BTUH IS MORE THAN 1.15 | | TIMES THE REQUIRED BTUH. FBC ENERGY CONSERVATION | | SECTION 403.6.1.1 | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-11-03 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-03 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-03 |
Time |
12:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-12-15 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2016-12-15 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2016-12-14 |
Time |
17:09 |
Sent To |
|
|
Notes |
2016-12-15 10:24:49 | 12/15/16- PASSED | | | | NO TREES ARE BEING MOVED SO NO TREE ALTERATION PERMIT | | REQUIRED | | WORK DONE DOESN'T EXCEED IMPROVEMENT VALUE SO NO | | LANDSCAPE PERMIT REQUIRED | | 25FT. REAR SETBACK MEETS 15FT. REQUIREMENT | | 28FT. SIDE SETBACK MEETS REQUIREMENT | | | | PLEASE CONTACT | | NATHAN WIRA | | [email protected] | | (561)822-1442 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-10-20 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2016-10-20 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2016-10-20 |
Time |
15:37 |
Sent To |
|
|
Notes |
2016-10-20 16:56:39 | 10/20/16- FAILED | | | | SF-7 SINGLE FAMILY LOW DENSITY RESIDENTIAL | | | | FAILED | | 1. PLEASE PROVIDE TWO(2)COPIES OF A SITE PLAN OR SURVEY | | SHOWING HOW THE PROPERTY WILL MEET SETBACK | | REQUIREMENTS. | | 2. IF YOU ARE PLANNING ON MOVING OR REMOVING TREES | | PLEASE APPLY FOR A TREE ALTERATION PERMIT. | | | | PASSED | | 1. NOT A HISTORIC STRUCTURE SO DEMOLITION IS PERMITTED. | | 2. BUILDING DOESN'T EXCEED 30FT. IN HEIGHT. | | 3. ONE KITCHEN MAKES THIS ONE UNIT. | | | | PLEASE CONTACT | | NATHAN WIRA | | [email protected] | | (561)822-1442 | | |
|
|