Plan Review Details - Permit 16100387
Plan Review Stops For Permit 16100387
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-12-28 Cont ID  
Sent By rmcdouga Date 2016-12-28 Time 18:50 Rev Time 0.00
Received By rmcdouga Date 2016-12-28 Time 17:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-11-30 Cont ID  
Sent By rmcdouga Date 2016-11-30 Time 09:00 Rev Time 0.00
Received By rmcdouga Date 2016-11-29 Time 16:58 Sent To  
Notes
2016-11-29 19:12:32PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) IN ORDER TO PROVIDE VENTILATION TO THE THE SINGLE
 ASSEMBLY ROOF SYSTEM, A CONTINOUS SOFFIT VENT WOULD BE
 REQUIRED. FBC-R806.1
  
 2) THE SINGLE ASSEMBLY ROOF SYSTEM HAS 2 X 8 RAFTERS,
 WHICH WILL HAVE A SPACE OF 7.25 INCHES. THIS WOULD NOT
 BE ENOUGH SPACE FOR THE R-30 INSULATION AND A ONE INCH
 AIR SPACE. FBC-R 806.3
  
 3) THE SIGNED AND SEALED ENHANCED FASTENING
 CALCULATIONS FOR THE TAMKO MODIFIED ROOF SYSTEM DO NOT
 SPECIFY THE NOA PAGE NUMBER, THE SYSTEM TYPE OR TYPE OF
 FASTENERS THAT WILL BE USED. THERE ARE TWO PAGES IN THE
 NOA FOR SYSTEMS WITH NON-INSULATED DECKS WHICH HAVE A
 MAXIMUM DESIGN PRESSURE OF -60PSF. HOWEVER, NEITHER ONE
 OF THEM HAS FASTENER SPACING OF 11" ON CENTER. NOTE:
 OPTION #1 ON PAGE 13 USES RING SHANK NAILS AND TIN CAPS
 WITH A MAXIMUM DESIGN PRESSURE OF -52.5 PSF.
  
 4) THE MECHANICAL PLANS SHOW DUCT WORK IN AN ATTIC. THE
 ADDITION HAS A SINGLE ASSEMBLY ROOF WITH NO ROOM FOR
 DUCTS. COORDINATE THE ARCHITECTURAL PLANS WITH THE
 MECHANICAL PLANS TO ADDRESS THIS ISSUE. FBC 107.2.1
  
 5) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-10-24 Cont ID  
Sent By mvaldes Date 2016-10-24 Time 09:51 Rev Time 0.00
Received By mvaldes Date 2016-10-24 Time 09:09 Sent To  
Notes
2016-10-24 09:51:001ST REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 PASSED WITH THE FOLLOWING PROVISO'S (RED-LINED ON
 PLANS)
  
 1] AFCI PROTECTION REQUIRED PER FBC-R SEC E3902.12.
 2] CARBON MONOXIODE ALARMS REQUIRED IN ACCORDANCE WITH
 FBC-R SEC 315.
 3] SMOKE ALARMS SHALL BE 3' AWAY FROM AC & BATH AS
 STATED IN NFPA 72 SEC 29.8.3.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-28 Cont ID  
Sent By rmcdouga Date 2016-12-28 Time 18:51 Rev Time 0.00
Received By rmcdouga Date 2016-12-07 Time 14:15 Sent To  
Notes
2016-12-07 14:16:31R25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-30 Cont ID  
Sent By rmcdouga Date 2016-11-30 Time 09:00 Rev Time 0.00
Received By rmcdouga Date 2016-10-17 Time 14:53 Sent To  
Notes
2016-10-17 14:53:17R13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-01-04 Cont ID  
Sent By rmcdouga Date 2017-01-04 Time 11:07 Rev Time 0.00
Received By rmcdouga Date 2017-01-04 Time 11:07 Sent To  
Notes
2017-01-04 11:08:10MU-2017-73, NO FEES WERE DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-11-29 Cont ID  
Sent By rmcdouga Date 2016-11-29 Time 14:25 Rev Time 0.00
Received By rmcdouga Date 2016-11-29 Time 14:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-12-28 Cont ID  
Sent By rmcdouga Date 2016-12-28 Time 17:47 Rev Time 0.00
Received By rmcdouga Date 2016-12-28 Time 17:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-11-29 Cont ID  
Sent By rmcdouga Date 2016-11-29 Time 18:57 Rev Time 0.00
Received By rmcdouga Date 2016-11-29 Time 17:24 Sent To  
Notes
2016-11-29 18:02:00PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THERE APPEAR TO BE SOME ERRORS IN THE ENERGY FORMS.
 THE PLANS FOR THE ADDITION SPECIFY A ONE FOOT OVERHANG
 AND THE FORMS LIST A TWO FOOT OVERHANG. THE PLANS SHOW
 A FLAT SINGLE ASSEMBLY ROOF ON THE ADDITION WITH A
 MODIFIED BITUMEN ROOF SYSTEM AND THE ENERGY FORMS
 SPECIFY A HIP ROOF WITH A FULL ATTIC AND COMPOSITE
 SHINGLES. ALL OF THE WINDOWS IN THE ADDITION FACE EAST
 AND THE FORMS LIST ONE FACING NORTH. PLEASE MAKE SURE
 THAT THE INFORMATION LISTED IN THE FORMS MATCH THE
 PLANS, FBC ENERGY CONSERVATION SECTION 405
  
 2) THE MECHANICAL PLANS SPECIFY THAT THE DUCTWORK WILL
 BE IN THE CEILING. THE PLANS SPECIFY A SINGLE ASSEMBLY
 FLAT ROOF AND DO NOT SHOW ANY SOFFITS FOR THE DUCTWORK.
 COORDINATE THE MECHANICAL WITH THE ARCHITECTURAL PLANS.
 FBC 107.2.1
  
 3) THE EQUIPMENT SIZING CALCULATIONS INDICATE THAT A
 ONE TON COOLING UNIT IS ADEQUATE. JUSTIFY WHY A 1.5 TON
 IS PROPOSED. THE ACTUAL TOTAL BTUH IS MORE THAN 1.15
 TIMES THE REQUIRED BTUH. FBC ENERGY CONSERVATION
 SECTION 403.6.1.1
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-11-03 Cont ID  
Sent By gjohnson Date 2016-11-03 Time 14:52 Rev Time 0.00
Received By gjohnson Date 2016-11-03 Time 12:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-12-15 Cont ID  
Sent By njwira Date 2016-12-15 Time 10:23 Rev Time 0.00
Received By njwira Date 2016-12-14 Time 17:09 Sent To  
Notes
2016-12-15 10:24:4912/15/16- PASSED
  
 NO TREES ARE BEING MOVED SO NO TREE ALTERATION PERMIT
 REQUIRED
 WORK DONE DOESN'T EXCEED IMPROVEMENT VALUE SO NO
 LANDSCAPE PERMIT REQUIRED
 25FT. REAR SETBACK MEETS 15FT. REQUIREMENT
 28FT. SIDE SETBACK MEETS REQUIREMENT
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-10-20 Cont ID  
Sent By njwira Date 2016-10-20 Time 16:54 Rev Time 0.00
Received By njwira Date 2016-10-20 Time 15:37 Sent To  
Notes
2016-10-20 16:56:3910/20/16- FAILED
  
 SF-7 SINGLE FAMILY LOW DENSITY RESIDENTIAL
  
 FAILED
 1. PLEASE PROVIDE TWO(2)COPIES OF A SITE PLAN OR SURVEY
 SHOWING HOW THE PROPERTY WILL MEET SETBACK
 REQUIREMENTS.
 2. IF YOU ARE PLANNING ON MOVING OR REMOVING TREES
 PLEASE APPLY FOR A TREE ALTERATION PERMIT.
  
 PASSED
 1. NOT A HISTORIC STRUCTURE SO DEMOLITION IS PERMITTED.
 2. BUILDING DOESN'T EXCEED 30FT. IN HEIGHT.
 3. ONE KITCHEN MAKES THIS ONE UNIT.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  