Plan Review Details - Permit 16100212
Plan Review Stops For Permit 16100212
Review Stop E ELECTRICAL
Rev No 2 Status N Date 2016-10-27 Cont ID  
Sent By albarran Date 2016-10-27 Time 18:37 Rev Time 0.00
Received By albarran Date   Time   Sent To I
Notes
2016-10-27 18:41:06AFTER A CONVERSATION WITH THE CONTRACTOR WHO CLAIMS
 THAT THERE WILL BE NO ELECTRICAL WORK IN SPITE OF
 SUBMITTING AN INCONCLUSIVE E1 PAGE. WE AGREED TO
 RELEASE THE ELECTRICAL REVIEW WITH THE FOLLOWING NOTE:
  
 NOTICE TO INSPECTORS:
 THIS PERMIT IS BEING ISSUED WITHOUT ANY ELECTRIC. IF
 ANY ELECTRICAL WORK IS OBSERVED, PLEASE STOP THE JOB
 AND REPORT TO CONSTRUCTION SERVICES.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-10-26 Cont ID  
Sent By albarran Date 2016-10-26 Time 11:38 Rev Time 0.00
Received By albarran Date 2016-10-26 Time 10:27 Sent To I
Notes
2016-10-26 11:40:44ELECTRICAL PLAN SUBMITTED WITHOUT AND ELECTRICAL SUB
 PERMIT OR A DEFINED ELECTRICAL SCOPE OF WORK. PROVIDE
 THE MISSING INFORMATION REQUESTED FOR A SUCCESSFUL
 ELECTRICAL PLAN REVIEW.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-10-27 Cont ID  
Sent By albarran Date 2016-10-27 Time 18:41 Rev Time 0.00
Received By albarran Date   Time   Sent To  
Notes
2016-10-27 18:43:1410/27/16 RELEASED ELECTRICAL REVIEW AS NOTED.
 CONTRACTOR NOTIFIED VIA EMAIL. FILE SENT TO SMALL READY
 BIN J. MA
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-10-26 Cont ID  
Sent By albarran Date 2016-10-26 Time 11:43 Rev Time 0.00
Received By albarran Date 2016-10-21 Time 10:02 Sent To  
Notes
2016-10-26 11:44:3010/26/16 FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR
 NOTIFIED VIA EMAIL. FILE SENT TO SMALL DENIED DRAWER J.
 MA
2016-10-25 18:25:56ROUTED TO MIKE ALBARRAN - JORGE V. 10/25/2016
2016-10-24 10:02:58RESUB ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-10-24 Cont ID  
Sent By lmarchan Date 2016-10-24 Time 10:02 Rev Time 0.00
Received By lmarchan Date 2016-10-18 Time 09:53 Sent To  
Notes
2016-10-19 09:54:09RESUB ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-14 Cont ID  
Sent By cpuell Date 2016-10-14 Time 11:13 Rev Time 0.00
Received By cpuell Date 2016-10-12 Time 11:25 Sent To  
Notes
2016-10-13 11:25:31REVISION ROUTED TO JVALIDO

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-10-25 Cont ID  
Sent By jvalido Date 2016-10-25 Time 17:24 Rev Time 0.00
Received By jvalido Date 2016-10-25 Time 16:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-10-19 Cont ID  
Sent By jvalido Date 2016-10-19 Time 17:20 Rev Time 0.00
Received By jvalido Date 2016-10-19 Time 16:20 Sent To  
Notes
2016-10-19 18:00:44CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 FLORIDA ENERGY CODE FBC 2014
  
 (1) PROVIDE (2) SETS OF PLANS.
 (2) PROVIDE EQUIPMENT SCHEDULE ON PLANS. INFORMATION
 REQUIRED FOLLOWS ( AHU, CONDENSER, BRAND, MODEL,
 SENSIBLE BTU, LATEND BTU, SEER).
 (3) PROVIDE LOCATION OF MINI-SPLIT AHU AND CONDENSER ON
 PLANS.
 (4) PROVIDE INFORMATION OF MINI-SPLIT IN EQUIPMENT
 SCHEDULE.
 (5) ENGINEER STAMP ON PLANS NOT SIGNED.
  
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-13 Cont ID  
Sent By jvalido Date 2016-10-13 Time 18:57 Rev Time 0.00
Received By jvalido Date 2016-10-13 Time 18:16 Sent To  
Notes
2016-10-13 18:54:09CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS MANAGEMENT. ELECTRONIC
 MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS
 OF FLORIDA STATUTES.
  
 (1) PROVIDE EQUIPMENT SCHEDULE AS PER R403.6.1.
 (2) PROVIDE LOCATION OF CONDENSER ON EXTERIOR OF BLDG.
 (3) CONFIRM INSULATION R VALUE. PLANS SHOW R8. DUCT
 INSULATION IS USUALLY R6.
 (4) BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. SEE ABOVE 107.2.1.4.
 (5) SHOW ON PLANS ALL BATH EXHUST.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (6) PROVIDE AHRI FOR EQUIPMENT ON PLANS. PLANS SHOW (2)
 2 TON SYSTEMS.
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  