Plan Review Details - Permit 16100069
Plan Review Stops For Permit 16100069
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-11-03 Cont ID  
Sent By cthroop Date 2016-11-03 Time 10:37 Rev Time 0.00
Received By cthroop Date 2016-11-03 Time 10:37 Sent To  
Notes
2016-11-03 10:38:32BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
  
 CATEGORY IV SUNROOM. ELECTRICAL, MECHANICAL, ENERGY AND
 IMPACT NOT REQUIRED.
  
 1. INCLUDE SGD AT MASTER BEDROOM ON APPLICATION OR
 REMOVE IT FROM PLANS.
 2. ENCLOSING THE SCREEN ROOM WITH GLASS VOIDS THE
 EGRESS REQUIREMENTS FOR BEDROOM #2. DEMONSTRATE HOW YOU
 WILL PROVIDE EGRESS FROM THIS ROOM.
 3. PROVIDE DEMENSIONS FOR ROUGH OPENINGS OF MASONRY
 WALLS. PROVIDE FRAMING DETAIL FOR EACH OPENING.
 4. DESIGNER TO PRINT NAME AND SIGN PLANS.
 5. SHOW LOCATION OF GFI AND SMOKE DETECTOR LISTED ON
 PLANS OR REMOVE FROM PLANS.
  
  
 R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED.
 BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM
 SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND
 RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE
 SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS
 SHALL BE REQUIRED IN EACH SLEEPING ROOM. WHERE
 EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY
 SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES
 (1118 MM) MEASURED FROMTHE FINISHED FLOOR TO THE BOTTOM
 OF THE CLEAR OPENING. WHERE A DOOR OPENING HAVING A
 THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES AS
 AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS PROVIDED
 WITH A BULKHEAD ENCLOSURE, THE BULKHEAD ENCLOSURE SHALL
 COMPLY WITH SECTION R310.3. THE NET CLEAR OPENING
 DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED
 BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND
 RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND
 RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE
 ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A
 WINDOW WELL IN ACCORDANCE WITH SECTION R310.2.
 EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN
 DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT
 OPENS TO A PUBLIC WAY.
  
 EXCEPTIONS:
 1. BASEMENTS USED ONLY TO HOUSE MECHANICAL EQUIPMENT
 AND NOT EXCEEDING TOTAL FLOOR AREA OF 200 SQUARE FEET
 (18.58 M2).
 2. THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE
 PERMITTED TO OPEN INTO A SCREEN ENCLOSURE, OPEN TO THE
 ATMOSPHERE, WHERE A SCREEN DOOR IS PROVIDED LEADING
 AWAY FROM THE RESIDENCE.
  
 R612.8.4 MASONRY ROUGH OPENINGS.
 MASONRY ROUGH OPENING DIMENSIONS SHALL BE WITHIN THE
 TOLERANCES SPECIFIED AT SECTION R606.16 AND, IN
 ADDITION, SHALL PROVIDE FOR A WINDOW PERIMETER SEALANT
 JOINT A MAXIMUM OF 1/4 INCHES (6.4 MM) IN WIDTH.
  
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-19 Cont ID  
Sent By cthroop Date 2016-10-19 Time 13:30 Rev Time 0.00
Received By cthroop Date 2016-10-19 Time 13:30 Sent To E
Notes
2016-10-19 14:02:42BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 DEFICIENT APPLICATION
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
  
 1. ELECTRICAL PERMIT REQUIRED - E3901.2
 2. MECHANICAL PERMIT REQUIRED - FBC1204.1
 3. DESIGNER TO SIGN PLANS
 4. PROVIDE SITE PLAN. IDENTIFY LOCATIO0N AND ELEVATION
 OF STRUCTURE
 5. PROVIDE FRAMING DETAILS FOR OPENINGS
 6. PROVIDE DESIGN WIND LOADS FOR OPENINGS
  
 E3901.2 GENERAL PURPOSE RECEPTACLE DISTRIBUTION.
 IN EVERY KITCHEN, FAMILY ROOM, DINING ROOM, LIVING
 ROOM, PARLOR, LIBRARY, DEN, SUN ROOM, BEDROOM,
 RECREATION ROOM, OR SIMILAR ROOM OR AREA OF DWELLING
 UNITS, RECEPTACLE OUTLETS SHALL BE INSTALLED IN
 ACCORDANCE WITH THE GENERAL PROVISIONS SPECIFIED IN
 SECTIONS E3901.2.1 THROUGH E3901.2.3 (SEE FIGURE
 E3901.2).
  
 1204.1 EQUIPMENT AND SYSTEMS.
 INTERIOR SPACES INTENDED FOR HUMAN OCCUPANCY SHALL BE
 PROVIDED WITH ACTIVE OR PASSIVE SPACE-HEATING SYSTEMS
 CAPABLE OF MAINTAINING AN INDOOR TEMPERATURE OF NOT
 LESS THAN 68?F (20?C) AT A POINT 3 FEET (914 MM) ABOVE
 THE FLOOR ON THE DESIGN HEATING DAY.
  
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
 FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION
 PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL
 FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING
 DIMENSIONS; AND ALL EXTERIOR ELEVATIONS:
  
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2016-11-03 Cont ID  
Sent By cthroop Date 2016-11-03 Time 10:36 Rev Time 0.00
Received By cthroop Date 2016-11-03 Time 10:36 Sent To  
Notes
2016-11-03 10:37:01CATEGORY IV SUNROOM. ELECTRICAL NOT REQUIRED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-10-19 Cont ID  
Sent By mvaldes Date 2016-10-19 Time 15:42 Rev Time 0.00
Received By mvaldes Date 2016-10-19 Time 14:39 Sent To M
Notes
2016-10-19 15:42:26REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 1] COMPLY WITH BUILDING PLANS EXAMINER IN DETERMINING
 THE CATEGORY OF THE SUNROOM 1-5, UPON CLEAR DEFINITION
 RECEPTACLE OUTLET SPACING AND ARC-FAULT PROTECTION
 REQUIREMENTS SHALL CORRECTLY APPLY.
  
 2] ALL SUNROOMS SHALL PROVIDE EXIT/ENTRANCE DOOR EGRESS
 ILLUMINATION PER FBC-R SEC E3903.3

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-01 Cont ID  
Sent By cpuell Date 2016-11-01 Time 09:27 Rev Time 0.00
Received By cpuell Date 2016-10-04 Time 14:40 Sent To  
Notes
2016-10-04 14:40:46ROUTED TO ZONING

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2016-11-03 Cont ID  
Sent By cthroop Date 2016-11-03 Time 10:35 Rev Time 0.00
Received By cthroop Date 2016-11-03 Time 10:35 Sent To  
Notes
2016-11-03 10:36:08CATEGORY IV SUNROOM. MECH. NOT REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-31 Cont ID  
Sent By jvalido Date 2016-10-31 Time 18:12 Rev Time 0.00
Received By jvalido Date 2016-10-31 Time 17:50 Sent To  
Notes
2016-10-31 18:08:22CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 1204.1 EQUIPMENT AND SYSTEMS.
 INTERIOR SPACES INTENDED FOR HUMAN OCCUPANCY SHALL BE
 PROVIDED WITH ACTIVE OR PASSIVE SPACE-HEATING SYSTEMS
 CAPABLE OF MAINTAINING AN INDOOR TEMPERATURE OF NOT
 LESS THAN 68?F (20?C) AT A POINT 3 FEET (914 MM) ABOVE
 THE FLOOR ON THE DESIGN HEATING DAY.
  
 (1) PROVIDE MECHANICAL PLANS AS PER FBC 2014 - 1204.1.
 (SEE ABOVE)
  
 FLORIDA ENERGY CODE FBC 2014
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-10-13 Cont ID  
Sent By njwira Date 2016-10-13 Time 16:29 Rev Time 0.00
Received By njwira Date 2016-10-05 Time 08:32 Sent To B
Notes
2016-10-13 16:30:2510/13/16- FAILED
  
 PLEASE PROVIDE A SITE PLAN OR A SURVEY SHOWING WHERE
 THE SUNROOM IS GOING IN RELATION TO REQUIRED SETBACKS.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  