Plan Review Details - Permit 16100040
Plan Review Stops For Permit 16100040
Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-10-21 Cont ID  
Sent By ccole Date 2016-10-21 Time 10:23 Rev Time 0.00
Received By ccole Date 2016-10-20 Time 16:44 Sent To  
Notes
2016-10-20 16:44:11RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-19 Cont ID  
Sent By ccole Date 2016-10-19 Time 12:39 Rev Time 0.00
Received By ccole Date 2016-10-17 Time 15:44 Sent To  
Notes
2016-10-17 15:44:35CCOLE'S DESK

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-10-21 Cont ID  
Sent By ccole Date 2016-10-21 Time 10:23 Rev Time 0.00
Received By ccole Date 2016-10-21 Time 10:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-10-19 Cont ID  
Sent By ccole Date 2016-10-19 Time 12:39 Rev Time 0.00
Received By ccole Date 2016-10-19 Time 12:39 Sent To  
Notes
2016-10-19 12:46:502ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16100040
 10/19/16
  
 1) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF
 THE AAON OUTSIDE AIR UNIT- SECTION 301.15.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-04 Cont ID  
Sent By ccole Date 2016-10-04 Time 14:05 Rev Time 0.00
Received By ccole Date 2016-10-04 Time 14:05 Sent To  
Notes
2016-10-04 14:19:381ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16100040
 10/4/16
  
 1) SITE SPECIFIC WIND LOAD ENGINEERING IS REQUIRED FOR
 INSTALLATION OF THE ROOF TOP MECHANCIAL EQUIPMENT PER
 SECTION 301.15. PROVIDE COMPLETE DETAILS AND DESIGN
 CRITERIA PER SECTION 1609 FBC-14 BULDING:
  
 WIND DESIGN CRITERIA
 2014P FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
 5) COMPONENTS & CLADDING PRESSURES POSITIVE & NEGATIVE
 TABLE 1609.2(2).
  
 2) ADVISORY: THE REQUIRED ATTACHMENTS TO THE PRIVATE
 PROVIDER NOTICE WERE NOT PROVIDED AS REQUIRED: 1.
 QUALIFICATION STATEMENTS AND/OR RESUMES OF THE PROVATE
 PROVIDER AND ALL DULY AUTHORIZED RESIDENTS. 2) PROOF OF
 INSURANCE FOR PROFESSIONAL AND COMPREHENSIVE LIABILIY
 PER FLORIDA STAUTES SECTION 553.791(16). 3) NAME AND
 LICENSE NUMBER OF THE INSPECTOR.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  