Plan Review Stops For Permit 16091117 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2016-12-06 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-12-06 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-12-06 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2016-11-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-11-18 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-11-18 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-10-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-10-27 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-10-27 |
Time |
14:30 |
Sent To |
|
|
Notes |
2016-10-27 15:15:40 | | | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | | | 1. CORRECT CODE SUMMARY ON PG. A-1 | | 2. LABEL PLANS WITH REQUIRED CEILING INSULATION FROM | | ENERGY SUBMITTAL (R30). | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN. (SEE ALSO SECTION 107.3.5). | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2016-12-06 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-12-06 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-12-06 |
Time |
15:22 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2016-11-30 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-11-30 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-11-30 |
Time |
14:32 |
Sent To |
|
|
Notes |
2016-11-30 14:32:56 | FAILED TO ALLOW RE-SUB WITHOUT REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-10-18 |
|
|
Cont ID |
|
Sent By |
vperez |
Date |
2016-10-18 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
vperez |
Date |
2016-10-18 |
Time |
09:37 |
Sent To |
|
|
Notes |
2016-10-18 09:37:07 | INITIAL ELECTRICAL PLAN REVIEW | | | | APPLICABLE CODES IN EFFECT: | | FLORIDA RES BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | EDITION | | NFPA 70- 2011 | | COMMENTS: | | | | 1. PROVIDE AIC CALCULATIONS FOR NEW SERVICE SHOWN AND | | LABEL SERVICE EQUIPMENT AND PANEL BOARDS WITH AIC | | RATINGS. FBC 107.3.5 | | 2. GENERAL NOTE TO INDICATED REQUIRED SEPARATE PERMITS | | FOR LOW VOLTAGE SYSTEMS. FBC 107.3.5 | | 3. SHOW EXTERIOR RECEPTACLE AT REAR PROTECTED BY GFCI | | DEVICE. FBC RES E3902.3 | | 4. PLEASE NOTE THAT ALL CIRCUITS? DESIGNATION AT THE | | PANELBOARDS MUST INDICATE WHAT AREA SPECIFICALLY OF THE | | HOUSE IT?S SERVICING. GENERAL LIGHTING DOES NOT MEET | | THESE REQUIREMENTS. EXAMPLE, LABEL BEDROOM 1, BEDROOM 2 | | ETC.?NEC 408.4 FIELD ID REQUIRED. FBC 107.3.5 | | 5. PROVIDE A NOTE TO INDICATE REQUIRED TAMPER RESISTANT | | RECEPTACLE THROUGHOUT. FBC RES E4002.14 | | 6. PROVIDE A NOTE PER FBC ENERGY CONSERVATION CODE TO | | INDICATE; 75% OF LAMPS TO HIGH EFFICACY LAMPS. | | 7. ELECTRICAL SHEET TO BE SIGNED AND SEALED BY DESIGNER | | OF RECORD. FBC 107.3.5 | | 8. EXTERIOR RECEPTACLES TO BE GFCI PROTECTED, LABEL AT | | THE PANEL CIRCUIT #26 FBC RES E3902.3 | | 9. ADDRESS SPACING FOR COUNTERTOP RECEPTACLES IN | | KITCHEN PER FBC RES E3901.4 LEFT OF RANGE. | | 10. SHOW LIGHTING OUTLET AT THE ATTIC ACCESS LOCATION | | PER FBC RES E3903.4 SHOW ATTIC LOCATION | | 11. PROVIDE A NOTE TO PROVIDE AFCI PROTECTION PER FBC | | RES E3902.12 | | 12. FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | QUESTIONS OR CONCERNS. | | | | VALENTINO PEREZ | | ELECTRICAL PLANS EXAMINER II | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2016-12-07 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2016-12-07 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2016-12-07 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-11-30 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-11-30 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-11-08 |
Time |
11:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-11-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-04 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-09-30 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2016-11-30 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-11-30 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-11-30 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2016-10-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-10-27 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-10-27 |
Time |
14:29 |
Sent To |
|
|
Notes |
2016-10-27 15:13:18 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2016-12-06 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2016-12-06 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2016-12-06 |
Time |
15:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2016-11-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-21 |
Time |
18:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-21 |
Time |
07:31 |
Sent To |
|
|
Notes |
2016-11-21 18:04:26 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #16091117 | | 11/21/16 | | | | 1) COMMENT #8 FROM THE 1ST REVIEW ABOUT THE DIRECTIONAL | | ORIENTATIONS FOR THE ROOMS, WALLS, WINDOW GLASS ETC. IN | | THE MANUAL J STILL EXISTS. PLEASE COMPLY. | | | | 2) COMMENTS #10 A, B, & C FROM THE 1ST REVIEW STILL | | EXIST. PLEASE COMPLY | | | | 3) FORM R405-2014 LISTS THE AC SYSTEM AT 16 SEER BUT | | THE NEW AC SCHEDULE INDICATES A 14 SEER SYSTEM. | | | | 4) PLEASE REMOVE THE FOUNDATION PLAN FROM THE MA-2 PLAN | | SHEET. THE FOUNDATION DRAWING REQUIRES A SIGNATURE AND | | SEAL BY A FL. LICENSED ENGINEER OR ARCHITECT. | | | | 5) A SEALED ENCLOSURE IS REQUIRED FOR THE AIR HANDLER | | RETURN IF IT IS TO BE LOCATED IN THE UTILITY ROOM- SEE | | SECTION R403.2.2 FBC-14 ENERGY CONSERVATION AND SECTION | | M1602.2 (3) FBC-14 RESIDENTIAL. | | | | 6) THE 9" TRANSFER DUCT FROM BEDROOM 1 IS UNDERSIZED. | | THE MINIMUM SIZE MUST BE 10" PER SECTION M1602.4 FBC-14 | | MECHANICAL. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-11-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2016-11-04 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2016-11-03 |
Time |
17:25 |
Sent To |
|
|
Notes |
2016-11-04 08:15:04 | 1ST REVIEW FBC-2014 RESIDENTIAL, ENERGY CONSERVATION | | PERMIT #16091117 | | 10/31/16 | | | | 1) THE AC PLAN ON A-2 AND THE AC SIZING CALCULATIONS | | MUST BEAR THE SIGNATURE OF THE PERSON RESPONSIBLE FOR | | THE DESIGN- SECTION 107.2.1 WPB AMENDMENTS TO THE FBC. | | PLEASE NOTE THAT ONLY FL. LICENSED DESIGN PROFESSIONALS | | OR INSTALLING AC CONTRACTORS ARE PERMITTED TO DRAW AC | | PLANS PER SECTION 105.3.1.2 | | | | 2) PROVIDE AN AC EQUIPMENT SCHEDULE ON THE PLAN- | | SECTION R403.6.1 FBC-14 ENERGY CONSERVATION | | | | 3) INDICATE THE BRANCH DUCT AND DIFFUSER SIZES- ONLY | | THE MAIN TRUCKS HAVE BEEN SIZED- SECTION 107.3.5.1.4. | | | | 4) SHOW THE CONDENSATE PIPING RUN AND DISPOSAL | | LOCATION- SECTION M1411.3 FBC- RESIDENTIAL. | | | | 5) SHOW THE DRYER VENT RUN AND TERMINATION LOCATION. | | INDICATE THE TYPE AND SIZE OF VENT AND VENT CAP- | | SECTION M1502. | | | | 6) INDICATE THE TYPE OF KITCHEN EXHAUST TO BE INSTALLED | | AND PROVIDE SPECIFICATIONS- REFER TO SECTION M1503- | | M1507 FBC-RESIDENTIAL. | | | | 7) PROVIDE A NUMBER FOR EACH BEDROOM- 1,2,3, OR 4 ON | | THE FLOOR PLAN SO THE PLAN MATCHES THE MANUAL J | | WORKSHEETS. | | | | 8) THE DIRECTIONAL ORIENTATIONS SHOWN IN THE MANUAL J | | WORKSHEETS FOR WINDOWS AND DOORS DO NOT APPEAR TO MATCH | | THEIR DIRECTIONAL ORIENTATIONS ON THE PLAN. | | | | 9) SHOW THE LOCATION OF THE AC CONDENSER AND PROVIDE | | DETAILS FOR INSTALLATION OF THE MOUNTING PAD AND | | ANCHORING THE CONDENSER- SECTIONS M1305.1.4.1, AND | | M1401.4. | | | | 10) ENERGY FORM R405-2014: | | | | A) PLEASE FILL IN ALL THE REQUESTED INFORMATION AT THE | | TOP OF PAGE 1- OWNER, BUILDER NAME, PERMIT OFFICE, | | PERMIT NUMBER, JURISDICTION. CORRECT THE CLIMATE ZONE 2 | | DESIGNATION TO 1A PER TABLE R301.1. | | | | B) THE SUBMITTED ENERGY FORM IS INDICATING A "WORST | | CASE" COMPLIANCE, HOWEVER A WORST CASE COMPLIANCE IS | | USED FOR MODEL HOMES AND NOT FOR INDIVIDUAL RESIDENCES | | AS NOTED IN SECTION R405.4.2 EXCEPTION, ENERGY | | CONSERVATION. PLEASE CORRECT PAGE 1 AND PAGE 4, AND | | REVISE THE WINDOW ORIENTATIONS SO THEY MATCH WITH THE | | ORIENTATIONS TO BE SHOWN ON THE CORRECTED MANUAL J | | WORKSHEETS. | | | | C) COMPLETE THE AIR BARRIER AND INSULATION INSPECTION | | CHECKLIST AND ALL REQUIRED INFORMATION AT THE TOP OF | | THE PAGE- OWNER, BUILDER NAME, PERMIT OFFICE, PERMIT | | NUMBER, JURISDICTION. | | | | 11) PLEASE SUBMIT TWO SETS OF CORRECTED PLANS PER | | SECTION 107.1 WPB AMENDMENTS TO THE FLORIDA BUILDING | | CODE. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2016-11-29 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-11-29 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-11-29 |
Time |
16:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-10-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2016-10-24 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2016-10-24 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2016-10-27 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-10-27 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-10-27 |
Time |
14:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2016-12-07 |
|
|
Cont ID |
|
Sent By |
|
Date |
2016-12-07 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2016-12-07 |
Time |
14:38 |
Sent To |
|
|
Notes |
2016-12-07 14:38:39 | ***ZONING PROVISO*** | | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | THE FOLLOWING CONDITIONS SHALL BE ADDRESSED: | | | | 1. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN, | | SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR REIEW. | | 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED | | LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL | | LANDSCAPE INSPECTION. | | | | PLEASE CONTACT ALANA WOOTEN 561-822-1449 WITH ANY | | QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2016-10-12 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2016-10-12 |
Time |
09:17 |
Sent To |
|
|
Notes |
2016-10-13 09:17:16 | *****ZONING FAILED****** | | | | LANDSCAPING: | | | | GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY | | DWELLING UNITS SHALL BE AS FOLLOWS: | | | | A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. | | PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | THE ZLDR. | | | | A CONDITIONAL APPROVAL CAN BE ISSUED THROUGH THE ZONING | | AND PLANNING DIVISION. AS A PART OF THE APPROVAL THE | | OWNER MUST AGREE TO THE FOLLOWING: | | | | 1) PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | FOR THE NEW SINGLE FAMILY RESIDENCE AT _______: | | A. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN | | IN COMPLIANCE WITH THE ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR) ARTICLE XIV, SHALL BE SUBMITTED TO | | THE BUILDING DIVISION FOR REVIEW. | | B. AN IRRIGATION PERMIT SHALL BE SUBMITTED TO THE | | BUILDING DIVISION FOR REVIEW. | | C. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED | | LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL | | LANDSCAPE INSPECTION (502). | | D. THE IRRIGATION SHALL BE INSTALLED IN ACCORDANCE WITH | | THE APPROVED IRRIGATION PERMIT AND PASS A PLUMBING | | FINAL INSPECTION (703). | | | | PLEASE CONTACT THE PLANNING DIVISION AT (561) 822-1435 | | FOR MORE INFORMATION. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | PLANNING DEPARTMENT WEBSITE AT | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS. | | | | ALANA WOOTEN | | PLANNING AND ZONING | | ASSOCIATE PLANNER | | 561-822-1449 | | [email protected] | | |
|
|