Plan Review Details - Permit 16091031
Plan Review Stops For Permit 16091031 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2016-10-13 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2016-10-13 |
Time |
14:29 |
Sent To |
E |
|
Notes |
2016-10-13 14:31:22 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER ? PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | | | 1. BUILDING TAKES NO EXCEPTION TO SUBMITTED PLANS. | | 2. ELECTRICAL AND MECHANICAL DEMO PERMITS REQUIRED FOR | | ROOF TOP EQUIPTMENT. | 2016-10-03 11:36:28 | SEE HOLDS FOR REQUIRED REMODEL PLAN. OK TO APPROVE PLAN | | REVIEW, BUT NOT TO ISSUE. | 2016-09-29 14:07:28 | BUILDING REVIEWER PLEASE ASSURE A REMODEL PLAN IS IN | | PLACE PRIOR TO ISSUANCE OF THIS PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
mvaldes |
Date |
2016-10-13 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
mvaldes |
Date |
2016-10-13 |
Time |
16:23 |
Sent To |
M |
|
Notes |
2016-10-13 16:44:12 | REVIEW 2014 5TH FBC ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 561-805-6713 | | [email protected] | | | | | | 1] ELECTRICAL SUB PERMIT REQUIRED FOR DEMO WORK. | | | | 2] PROVIDE ELECT TEMP POWER PLANS AND SHOW GFCI OUTLETS | | PER NEC 590. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-10-18 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-10-18 |
Time |
05:48 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-09-28 |
Time |
14:14 |
Sent To |
|
|
Notes |
2016-10-17 17:24:44 | ROUTED TO TIM LARGE 10/17/2016 - JORGE V. | 2016-09-29 14:14:56 | ROUTED TO ZONING |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2016-10-17 |
|
|
Cont ID |
|
Sent By |
jvalido |
Date |
2016-10-17 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
jvalido |
Date |
2016-10-17 |
Time |
17:01 |
Sent To |
|
|
Notes |
2016-10-17 17:06:52 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | (1) PROVIDE ON THE PLANS A NOTATION STATING THERE IS NO | | HVAC WORK BEING DONE. | | (2) PROVIDE MECHANICAL PLANS IF THERE IS HVAC WORK | | BEING DONE. | | | | FLORIDA ENERGY CODE FBC 2014 | | | | (3) PROVIDE HEAT LOAD CALCULATIONS AND ENERGY | | CALCULATIONS IF APPLICABLE. | | | | JORGE VALIDO | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | [email protected] | | 561-805-6716 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2016-10-18 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2016-10-18 |
Time |
05:48 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2016-10-18 |
Time |
05:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2016-10-12 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2016-10-12 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2016-09-30 |
Time |
15:11 |
Sent To |
B |
|
Notes |
|
|
|