Plan Review Details - Permit 16090909
Plan Review Stops For Permit 16090909 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-10-13 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-10-13 |
Time |
07:15 |
Sent To |
I |
|
Notes |
2016-10-13 07:47:08 | APPROVED ELECTRICAL REVIEW. IN CONVERSATION W/MR. | | PATTERSON THE DRAWING WAS CORRECTED TO COMPLY. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2016-09-29 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-09-29 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-09-28 |
Time |
19:05 |
Sent To |
I |
|
Notes |
2016-09-29 08:30:05 | ELECTRICAL REVIEW NOTES | | REVIEWED FOR COMPLIANCE WITH: | | ELECTRICAL REVIEW NOTES | | REVIEWED FOR COMPLIANCE WITH: | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | PROJECT NAME: | | JOB ADDRESS: | | DESCRIPTION: REPLACE METER CAN AND 2 LAKE AERATOR | | CONTROLLERS | | MASTER PERMIT: 16090909 | | | | BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS. | | ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF | | SUBMITTED CORRECTIONS. | | | | 1. NEC 682.11: YOU SHALL SUBMIT A SITE DIAGRAM/PLAN | | SHOWING THE LOCATION OF EVERY ELECTRICAL COMPONENT | | ASSOCIATED WITH THE PERMIT TO ASCERTAIN COMPLIANCE WITH | | RELATION TO THE SHORELINE AND THE ELECTRICAL DATUM | | PLANE. | | 2. ALL LIVE PARTS SHALL BE ELEVATED 12? ABOVE THE EDP & | | SERVICE EQUIPMENT SHALL DISCONNECT WHEN THE WATER RISES | | TO THE EDP. | | 3. NEC 682.33(A): YOU SHALL SHOW ON THE SITE PLAN THE | | REQUIRED EQUIPOTENTIAL BONDING PLANE. | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | GREATLY APPRECIATED. | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | CONTACT ME DIRECTLY. | | | | THANK YOU, | | MIKE ALBARRAN | | ELECTRICAL PLANS EXAMINER | | PH: 561-805-6746 | | EMAIL: [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2016-10-13 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-10-13 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-10-13 |
Time |
07:00 |
Sent To |
|
|
Notes |
2016-10-13 07:50:30 | 10/13/16 APPROVED ELECTRICAL REVIEW. CONTACTED ISAAC | | PATTERSON VIA EMAIL. FILE SENT TO SMALL READY BIN U. MA | 2016-10-13 07:48:20 | MR. PATTERSON EMAIL CORRECTED DRAWINGS DIRECTLY TO ME | | FOR APPROVAL. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2016-09-29 |
|
|
Cont ID |
|
Sent By |
albarran |
Date |
2016-09-29 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
albarran |
Date |
2016-09-26 |
Time |
08:03 |
Sent To |
|
|
Notes |
2016-09-29 08:46:53 | FAILED ELECTRICAL REVIEW AS NOTED. SPOKE W/EC TO ADVISE | | OF NEEDED CORRECTIONS. | 2016-09-27 08:05:14 | ELEC <5K |
|
|
|