Plan Review Details - Permit 16090562
Plan Review Stops For Permit 16090562
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-12-01 Cont ID  
Sent By jwitmer Date 2016-12-01 Time 14:10 Rev Time 0.00
Received By jwitmer Date 2016-12-01 Time 11:26 Sent To  
Notes
2016-12-01 14:09:57 
  
  
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16090562
 ADD: 600 OKEECHOBEE BLVD./RENOVATION SOUTH POOL BAR
 CONT: HEDRICK BROTHERS
 TEL: 561-267-1309
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. DEC. 01/2016
  
 ACTION: BUILDING PROVISO
  
 1A) PROVISO/ DEFERRED SUBMITTAL 107.3.4.2. PROVIDE
 COMPLIANCE WITH / 2014 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) DOORS
 (G) PRE-ENGINEERED A/C STANDS
  
 1B) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 2) PROVISO: THE CONTRACTOR IS REQUIRED TO PROVIDE WELD
 PROCEDURE SPECIFICATIONS & WELDER WELD OPERATOR
 PERFORMANCE QUALIFICATION RECORDS IN ACCORDANCE WITH
 THE REFERENCED STANDARD. 2014 FBC-B 2204.1 WELDING. THE
 DETAILS OF DESIGN, WORKMANSHIP AND TECHNIQUE FOR
 WELDING, INSPECTION OF WELDING AND QUALIFICATION OF
 WELDING OPERATORS SHALL CONFORM TO THE REQUIREMENTS OF
 THE SPECIFICATIONS LISTED IN SECTIONS 2205, 2206, 2207,
 2210 AND 2211.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-17 Cont ID  
Sent By jwitmer Date 2016-10-17 Time 14:34 Rev Time 0.00
Received By jwitmer Date 2016-10-17 Time 14:34 Sent To  
Notes
2016-10-17 14:28:55BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16090562
 ADD: 600 OKEECHOBEE BLVD./RENOVATION SOUTH POOL BAR
 CONT: HEDRICK BROTHERS
 TEL: 561-267-1309
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. OCT. 17/2016
 ACTION: DENIED
  
  
 1) SHEET S0.1 INDICATES PRESSURES FOR THIS BUILDING.
 THERE IS A TABLE FOR COMPONENTS AND CLADDING FOR
 PRESSURES FOR BUILDINGS GREATER THAN 60 FT. THE TABLE
 ITSELF IS NOT IDENTIFIED? THE DESIGN CRITERIA INDICATES
 ASCE 710 170 VULT/ EXPOSURE D. PLEASE NOTE THE
 PRESSURES ARE LOW WHEN COMPARED TO ASCE 7-10 TABLE
 30.7.2 COMPONENTS AND CLADDING PART 4 / V= 160-200 MPH/
 VULT/ H=90-160. PLEASE NOTE THE PROVIDED PRESSURES ARE
 EVEN LOWER THAN THE PRESSURES PREFORMED IN THE WIND
 TUNNEL TESTING FOR THIS BUILDING.
  
 2) PROVIDE COMPLIANCE WITH / 2014 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) DOORS
 (G) PRE-ENGINEERED A/C STANDS
  
 3) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 4) SHEET M1.0 SHOWS A NEW A/C STAND PLEASE PROVIDE
 COMPLIANCE WHEN SUBMITTING THE ROOF TOP STAND PRODUCT
 APPROVAL, PLEASE IDENTIFY THE CALCULATION OF THE AREA
 OF THE ROOF TOP COMPRESSORS, THE MEAN ROOF HEIGHT OF
 THE STAND AND COMPRESSORS, WEIGHT, CIRCLED THE DESIGN
 PARAMETERS IN THE TABLES , ANCHORS AND UPLIFT VERSES
 MOMENT.
 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL
 MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY
 METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT
 EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY
 AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES.
 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS.
  
 5) PLEASE SHOW COMPLIANCE WITH 2014 FBC-B 1509.6.4
 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED
 STRUCTURES. WHERE EQUIPMENT AND APPLIANCES REQUIRING
 ACCESS ARE INSTALLED ON ROOFS OR ELEVATED STRUCTURES AT
 A HEIGHT EXCEEDING 16 FEET), SUCH ACCESS SHALL BE
 PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, THE
 EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL TO
 THE EQUIPMENT AND APPLIANCES? LEVEL SERVICE SPACE. SUCH
 ACCESS SHALL NOT REQUIRE CLIMBING OVER OBSTRUCTIONS
 GREATER THAN 30 INCHES HIGH.
  
 6) THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER WELD OPERATOR PERFORMANCE
 QUALIFIACTION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARD. 2014 FBC-B 2204.1 WELDING. THE DETAILS OF
 DESIGN, WORKMANSHIP AND TECHNIQUE FOR WELDING,
 INSPECTION OF WELDING AND QUALIFICATION OF WELDING
 OPERATORS SHALL CONFORM TO THE REQUIREMENTS OF THE
 SPECIFICATIONS LISTED IN SECTIONS 2205, 2206, 2207,
 2210 AND 2211.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-11-10 Cont ID  
Sent By vperez Date 2016-11-10 Time 07:25 Rev Time 0.00
Received By vperez Date 2016-11-10 Time 07:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-09-23 Cont ID  
Sent By vperez Date 2016-09-23 Time 08:42 Rev Time 0.00
Received By vperez Date 2016-09-23 Time 08:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By vperez Date 2016-09-21 Time 13:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-11-10 Cont ID  
Sent By wjolin Date 2016-11-10 Time 10:53 Rev Time 0.00
Received By wjolin Date 2016-11-10 Time 10:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-09-23 Cont ID  
Sent By wjolin Date 2016-09-23 Time 15:16 Rev Time 0.00
Received By wjolin Date 2016-09-23 Time 14:48 Sent To  
Notes
2016-09-23 15:16:02600 OKEECHOBEE BOULEVARD
 PERMIT #16090562
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE NEW HOLLOW METAL DOOR TO THE FAR WEST OPENS INTO
 AND OBSTRUCTS THE SIDEWALK EGRESS PATH OF THE POOL
 DECK. I BELIEVE THE ORIGINAL LIFE SAFETY PLAN INDICATED
 AN OCCUPANT LOAD OF 300-400 UTILIZING THIS EGRESS PATH
 BETWEEN THE HOTEL AND CONVENTION CENTER.
  
 THE GRILL IS LOCATED CLOSER THAN 10 FEET TO THE
 BUILDING AND THE NEW ROOF TRELLIS. PER NFPA 1 SECTION
 10.11.6 COOKING EQUIPMENT: NO HIBACHI, GRILL, OR OTHER
 SIMILAR DEVICES USED FOR COOKING, HEATING, OR ANY OTHER
 PURPOSE SHALL BE USED OR KINDLED ON ANY BALCONY, UNDER
 ANY OVERHANGING PORTION, OR WITHIN 10 FEET OF ANY
 STRUCTURE. RELOCATE OR PROTECT THE GRILL IN ACCORDANCE
 WITH NFPA 96 - STANDARD FOR VENTILATION CONTROL AND
 FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-02 Cont ID  
Sent By cpuell Date 2016-12-02 Time 16:30 Rev Time 0.00
Received By cpuell Date 2016-11-04 Time 16:25 Sent To  
Notes
2016-11-04 16:25:32C19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-17 Cont ID  
Sent By jwitmer Date 2016-10-17 Time 14:36 Rev Time 0.00
Received By jwitmer Date 2016-09-15 Time 14:54 Sent To  
Notes
2016-09-16 14:55:02C08

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-10-17 Cont ID  
Sent By jwitmer Date 2016-10-17 Time 14:33 Rev Time 0.00
Received By jwitmer Date 2016-10-17 Time 14:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-11-10 Cont ID  
Sent By ccole Date 2016-11-10 Time 12:23 Rev Time 0.00
Received By ccole Date 2016-11-10 Time 12:23 Sent To  
Notes
2016-11-10 12:25:59MECHANICAL PROVISOS:
 11/10/16
  
 1) SITE SPECIFIC WIND LOAF ENGINEERING AND APPROVED
 NOA/PRODUCT APPROVAL FOR THE ROOF STAND SHALL BE
 SUBMITTED PRIOR TO INSPECTION.
  
 2) THE RELOCATED WOD-BURNING GRILL SHALL BE INSTALLED
 IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. SPECS
 SHALL BE ONSITE AT TIME OF INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-09-20 Cont ID  
Sent By ccole Date 2016-09-20 Time 16:17 Rev Time 0.00
Received By ccole Date 2016-09-20 Time 16:17 Sent To  
Notes
2016-09-20 16:28:321ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16090562
 9/20/16
  
 1) PLEASE PROVIDE ADDITIONAL INFORMATION CONCERNING THE
 RELOCATED GRILL: A) MAKE AND MODEL. B) TYPE OF FUEL. C)
 IS THERE AN EXISTING EXHAUST HOOD BEING RELOCATED WITH
 IT?
  
 2) PROVIDE THE WIND LOAD DESIGN CRITERIA FOR THE
 ROOFTOP CONDENSER AND STAND INSTALLATIONS- SECTION
 301.15 FBC-14 MECHANICAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-11-28 Cont ID  
Sent By gjohnson Date 2016-11-28 Time 11:53 Rev Time 0.00
Received By gjohnson Date 2016-11-28 Time 11:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-10-11 Cont ID  
Sent By gjohnson Date 2016-10-11 Time 16:09 Rev Time 0.00
Received By gjohnson Date 2016-10-11 Time 11:27 Sent To  
Notes
2016-10-11 16:07:281ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. THE CONDENSATE DRAIN SHALL NOT DRAIN INTO SUMP PIT
 IN POOL EQUIPMENT ROOM CONDENSATE SHALL DRAIN TO STORM
 OR OUT SAID BUILDING TO PLATED AREA. PER WEST PALM
 BEACH, FLORIDA - CODE OF ORDINANCES SEC. 90-126. 5)
  
 STORMWATER, SURFACE WATER, GROUNDWATER, ARTESIAN WELL
 WATER, ROOF RUNOFF, SUBSURFACE DRAINAGE, SWIMMING POOL
 DISCHARGES, UNCONTAMINATED COOLING WATER, UNPOLLUTED
 INDUSTRIAL PROCESS WATERS, AIR CONDITIONING CONDENSATE,
 UNLESS SPECIFICALLY AUTHORIZED BY THE CITY IN WRITING.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-12-02 Cont ID  
Sent By eschneid Date 2016-12-02 Time 14:34 Rev Time 0.50
Received By eschneid Date 2016-12-02 Time 14:34 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-09-27 Cont ID  
Sent By eschneid Date 2016-09-27 Time 11:01 Rev Time 1.00
Received By eschneid Date 2016-09-26 Time 15:45 Sent To  
Notes
2016-09-27 11:21:35FAILED
  
 1) THE MINOR AMENDMENT FOR THE POOL BAR HAS NOT BEEN
 APPROVED. ZONING WILL NOT APPROVE THIS PERMIT UNTIL THE
 INFORMATION REQUIRED TO APPROVE THE MINOR AMENDMENT HAS
 BEEN SUBMITTED TO THE PLANNING DIVISION.
  
 2) PROVIDE THE NEW SQUARE FOOTAGE OF THE POOL BAR AREA
 ON THE POOL BAR SITE PLAN. THE AREA UNDER THE TRELLIS
 SHALL BE INCLUDED IN THE SQUARE FOOTAGE.
  
 3) PROVIDE WHAT LANDSCAPE IS PROPOSED IN THE PLANTER
 WITH THIS PERMIT AND A SEPARATE LANDSCAPE PERMIT WILL
 NOT BE REQUIRED.
  
 4) PROVIDE VERIFICATION THAT THE NEW CONDENSING UNIT,
 AS IT IS MOUNTED ON TOP OF THE EPQUIPMENT RACK, IS
 SCREENED FROM THE EXTERIOR OF THE SITE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.