Plan Review Details - Permit 16090058
Plan Review Stops For Permit 16090058
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-12-05 Cont ID  
Sent By cthroop Date 2016-12-05 Time 09:14 Rev Time 0.00
Received By cthroop Date 2016-12-05 Time 09:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-11-15 Cont ID  
Sent By cthroop Date 2016-11-15 Time 13:56 Rev Time 0.00
Received By cthroop Date 2016-11-15 Time 13:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-09-09 Cont ID  
Sent By cthroop Date 2016-09-09 Time 12:32 Rev Time 0.00
Received By cthroop Date 2016-09-09 Time 12:30 Sent To  
Notes
2016-09-09 12:34:27BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: DENIED
  
 1. PROVIDE FOUNDATION DETAIL.
 2. PROVIDE SIGN ATTACHMENT DETAIL.
 3. PROVIDE DESIGN WIND LOADS FOR SIGN.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-11-14 Cont ID  
Sent By mvaldes Date 2016-11-14 Time 17:02 Rev Time 0.00
Received By mvaldes Date 2016-11-14 Time 16:11 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-09-08 Cont ID  
Sent By mvaldes Date 2016-09-08 Time 18:43 Rev Time 0.00
Received By mvaldes Date 2016-09-08 Time 18:29 Sent To B
Notes
2016-09-08 18:46:31REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 1] FBC-E SECTION C405.2.4 EXTERIOR LIGHTING CONTROLS.
 LIGHTING NOT DESIGNATED FOR DUSK-TO-DAWN OPERATION
 SHALL BE CONTROLLED BY EITHER A COMBINATION OF A
 PHOTOSENSOR AND A TIME SWITCH, OR AN ASTRONOMICAL TIME
 SWITCH. LIGHTING DESIGNATED FOR DUSK-TO-DAWN OPERATION
 SHALL BE CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR
 PHOTOSENSOR.
 ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING
 PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER
 FOR A PERIOD OF AT LEAST 10 HOURS. ADD A NOTE TO THE
 PLANS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-12-05 Cont ID  
Sent By cthroop Date 2016-12-05 Time 09:13 Rev Time 0.00
Received By cthroop Date 2016-11-28 Time 13:57 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-15 Cont ID  
Sent By cthroop Date 2016-11-15 Time 13:55 Rev Time 0.00
Received By cthroop Date 2016-10-26 Time 13:37 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-09 Cont ID  
Sent By cthroop Date 2016-09-09 Time 12:30 Rev Time 0.00
Received By cthroop Date 2016-09-02 Time 14:59 Sent To  
Notes
2016-09-02 14:59:59ROUTED TO ZONING

Review Stop Z ZONING
Rev No 3 Status P Date 2016-12-02 Cont ID  
Sent By cthroop Date 2016-12-05 Time 09:13 Rev Time 0.00
Received By njwira Date 2016-11-29 Time 16:25 Sent To B
Notes
2016-12-02 11:49:5412/2/16- PASSED
  
 SETBACKS MET
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  

Review Stop Z ZONING
Rev No 2 Status F Date 2016-11-01 Cont ID  
Sent By cthroop Date 2016-11-15 Time 13:56 Rev Time 0.00
Received By njwira Date 2016-10-27 Time 15:56 Sent To B
Notes
2016-11-01 16:29:0311/1/16- FAILED
  
 10FT8IN. DOESN'T MEET THE 15FT. RIGHT OF WAY
 REQUIREMENT
 75FT. 9 AND 1/2 IN. MEETS THE SETBACK REQUIREMENT FROM
 THE NEIGHBORING PROPERTY.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-09-08 Cont ID  
Sent By njwira Date 2016-09-08 Time 15:38 Rev Time 0.00
Received By njwira Date 2016-09-06 Time 13:51 Sent To E
Notes
2016-09-08 15:40:129/8/16- FAILED
  
 ZONE: MF-32 MULTI-FAMILY HIGH DENSITY RESIDENTIAL
  
 FAILED
  
 1. PLEASE PROVIDE A SURVEY OR SITE PLAN SHOWING THE
 SETBACKS.
  
 PASSED
  
 1. 4FT. HIGH SIGN MEETS THE 4FT. MAXIMUM HEIGHT OF A
 SIGN.
 2. 40SQFT. MEETS THE 48SQFT. MAXIMUM
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  