Plan Review Details - Permit 16081168
Plan Review Stops For Permit 16081168
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-12-14 Cont ID  
Sent By jwitmer Date 2016-12-14 Time 06:27 Rev Time 0.00
Received By jwitmer Date 2016-12-14 Time 06:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-12-02 Cont ID  
Sent By jwitmer Date 2016-12-02 Time 16:40 Rev Time 0.00
Received By jwitmer Date 2016-12-02 Time 16:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-09-02 Cont ID  
Sent By jwitmer Date 2016-09-02 Time 10:31 Rev Time  
Received By jwitmer Date 2016-09-02 Time 07:15 Sent To  
Notes
2016-09-02 10:31:10BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16081168
 ADD: 2727 GEORGIA AVE.
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-502-1752
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. SEPT. 02/2016
 ACTION: DENIED
  
 1) THE LIFE SAFETY SHEET INDICATES THIS IS A CHANGE OF
 OCCUPANCY DAYCARE WITH AN OCCUPANT LOAD OF 31 OCCUPANTS
 (20 NET). PLEASE PROVIDE THE SQUARE FOOTAGE OF THE
 CHANGE OF OCCUPANCY AND SEE FBC-B TABLE 10041.2 THE
 OCCUPANT LOAD FACTOR IS (35 NET).
  
 2) THE CODE ANALYSIS INDICATES THE OCCUPANCY AS AN (D)
 DAYCARE OCCUPANCY. PLEASE INDICATE AS TO WHICH TYPE OF
 DAYCARE/ EDUCATIONAL FACILITY THIS USE WILL FALL INTO:
 2014 FBC-B 305.2 GROUP E, DAY CARE FACILITIES. THIS
 GROUP INCLUDES BUILDINGS AND STRUCTURES OR PORTIONS
 THEREOF OCCUPIED BY MORE THAN FIVE CHILDREN OLDER THAN
 2 1/2 YEARS OF AGE WHO RECEIVE EDUCATIONAL, SUPERVISION
 OR PERSONAL CARE SERVICES FOR FEWER THAN 24 HOURS PER
 DAY.
 OR
 308.6.1 CLASSIFICATION AS GROUP E. A CHILD DAY CARE
 FACILITY THAT PROVIDES CARE FOR MORE THAN FIVE BUT NO
 MORE THAN 100 CHILDREN 2 1/2 YEARS OR LESS OF AGE,
 WHERE THE ROOMS IN WHICH THE CHILDREN ARE CARED FOR ARE
 LOCATED ON A LEVEL OF EXIT DISCHARGE SERVING SUCH ROOMS
 AND EACH OF THESE CHILD CARE ROOMS HAS AN EXIT DOOR
 DIRECTLY TO THE EXTERIOR, SHALL BE CLASSIFIED AS GROUP
 E.
 OR
 CHILDREN 2 1/2 YEARS OF AGE OR LESS USUALLY ARE NOT
 ABLE TO RECOGNIZE AN EMERGENCY SITUATION, MAY NOT
 RESPOND APPROPRIATELY OR MAY NOT BE ABLE TO EGRESS
 WITHOUT ASSISTANCE; THUS FACILITIES THAT HAVE MORE THAN
 5 CHILDREN 2 1/2 YEARS OF AGE OR LESS ARE CLASSIFIED AS
 CHILD CARE FACILITIES AND CONSIDERED TO BE GROUP I-4.
  
 3) THE PLAN INDICATES A PROPOSED DAYCARE CLASSROOM, IS
 THIS ROOM BEING ADDED TO AN EXISTING DAYCARE? THE PLANS
 DO NOT SHOW WHERE THE TOILET FACILITIES FOR THE
 DAYCARE, NOR THE FACILITIES TO BE USED FOR THE ADULTS?
  
  
 4A) 468.3.5.2 TEACHER TOILETS. FACULTY AND STAFF
 TOILETS SHALL BE SEPARATE FROM STUDENT TOILETS.
  
 4B) 468.3.5.5 WALLS. WALLS IN TOILET ROOMS SHALL BE
 IMPERVIOUS TO A HEIGHT OF AT LEAST 4 FEET (1219 MM)
 ABOVE THE FLOOR. WALLS IN KITCHENS, SCULLERIES, CAN
 WASH AREAS, AND SHOWER ROOMS SHALL BE IMPERVIOUS TO A
 HEIGHT OF AT LEAST 6 FEET (1829 MM) ABOVE THE FLOOR.
 TOILET AND SHOWER PARTITIONS SHALL BE IMPERVIOUS.
  
 4C) 2014 FBC-ACCESS. CODE 604.1 GENERAL. WATER CLOSETS
 AND TOILET COMPARTMENTS SHALL COMPLY WITH 604.2 THROUGH
 604.8. EXCEPTION: WATER CLOSETS AND TOILET COMPARTMENTS
 FOR CHILDREN?S USE SHALL BE PERMITTED TO COMPLY WITH
 604.9. 604.9 WATER CLOSETS AND TOILET COMPARTMENTS FOR
 CHILDREN?S USE.
  
 4D) WATER CLOSETS AND TOILET COMPARTMENTS FOR
 CHILDREN?S USE SHALL COMPLY WITH 604.9.
  
 4E) 468.3.4 DIAPER CHANGING STATIONS. A DIAPER CHANGING
 STATION SHALL BE LOCATED IN OR ADJACENT TO ANY
 CLASSROOM WHERE CHILDREN WEARING DIAPERS ARE IN
 ATTENDANCE. A HAND WASHING LAVATORY SHALL BE PROVIDED
 WITHIN THE CHANGING STATION AREA. ACCESS SHALL BE
 PROVIDED TO THE LAVATORY WITHOUT OPENING DOORS OR
 TOUCHING A HANDLE.
  
 5) 466.3 BATHROOM DOORS. EVERY BATHROOM DOOR LOCK SHALL
 BE DESIGNED TO PERMIT OPENING OF THE LOCKED DOOR FROM
 THE OUTSIDE IN AN EMERGENCY. THE OPENING DEVICE SHALL
 BE READILY ACCESSIBLE TO THE STAFF.
  
 6) 466.2 CLOSET DOORS. EVERY CLOSET DOOR LATCH SHALL BE
 SUCH THAT CLIENTS CAN OPEN THE DOOR FROM INSIDE THE
 CLOSET.
  
 7) THE LIFE SAFETY PLANS INDICATE A DOORWAY TO A
 PLAYGROUND PLEASE SHOW COMPLIANCE IF REQUIRED. 1015.6
 DAY CARE MEANS OF EGRESS. DAY CARE FACILITIES, ROOMS OR
 SPACES WHERE CARE IS PROVIDED FOR MORE THAN 10 CHILDREN
 THAT ARE 21/2 YEARS OF AGE OR LESS, SHALL HAVE ACCESS
 TO NOT LESS THAN TWO EXITS OR EXIT ACCESS DOORWAYS.
  
 8) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY.
 THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-12-21 Cont ID  
Sent By mvaldes Date 2016-12-21 Time 09:49 Rev Time 0.00
Received By mvaldes Date 2016-12-21 Time 09:34 Sent To  
Notes
2016-12-21 09:50:363RD REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 PASSED WITH THE FOLLOWING PROVISO'S
  
 1] IN ALL CHILD CARE FACILITIES, ALL NONLOCKING-TYPE,
 125-VOLT, 15- AND 20- AMPERE RECEPTACLES SHALL BE
 LISTED TAMPER-RESISTANT RECEPTACLES. NEC 406.14
  
 2] FBC-B 1006.2. EMERGENCY LIGHTING IS REQUIRED
  
 3] FBC-B 1011. EXIT SIGNAGE REQUIRED.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-11-17 Cont ID  
Sent By mvaldes Date 2016-11-17 Time 11:13 Rev Time 0.00
Received By mvaldes Date 2016-11-17 Time 10:36 Sent To  
Notes
2016-11-17 11:12:58REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 PASSED WITH THE FOLLOWING PROVISO'S
  
 1] IN ALL CHILD CARE FACILITIES, ALL NONLOCKING-TYPE,
 125-VOLT, 15- AND 20- AMPERE RECEPTACLES SHALL BE
 LISTED TAMPER-RESISTANT RECEPTACLES. NEC 406.14
  
 2] FBC-B 1006.2. EMERGENCY LIGHTING IS REQUIRED
  
 3] FBC-B 1011. EXIT SIGNAGE REQUIRED.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-09-09 Cont ID  
Sent By albarran Date 2016-09-09 Time 11:19 Rev Time 0.00
Received By albarran Date 2016-09-09 Time 11:02 Sent To  
Notes
2016-09-09 11:33:58ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC)
  
 PROJECT NAME: SUNFLOWER LEARNING CENTER.
 JOB ADDRESS: 2727 GEORGIA AVE.
 DESCRIPTION: CHANGE OF USE
 MASTER PERMIT: 16081168
  
 BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS.
 ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF
 SUBMITTED CORRECTIONS.
  
 1. BEFORE A PROPER ELECTRICAL REVIEW CAN BE CONDUCTED I
 NEED TO KNOW AND IT SHOULD BE INDICATED ON THE PLANS
 THE CURRENT GROUP AND CLASSIFICATION OF THE AREA IN
 QUESTION ALONG WITH THE NEW GROUP AND CLASSIFICATION.
 2. DEPENDING ON THE ABOVE, A CHANGE IN FIRE ALARM
 SYSTEM MAY BE REQUIRED. IF SO, THE FIRE ALARM WORK
 SHALL BE SUBMITTED UNDER A SEPARATE PERMIT AND PLANS
 SUBMITTAL.
 3. INCLUDE ON THE PLANS ANY FIRE SEPARATIONS APPLICABLE
 TO THE AREA IN QUESTION.
 4. ADDITIONAL CORRECTIONS MAY BE REQUIRED ONCE THE
 PLANS AS DESCRIBED ABOVE ARE SUBMITTED.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2016-12-20 Cont ID  
Sent By wjolin Date 2016-12-20 Time 07:21 Rev Time 0.00
Received By wjolin Date 2016-12-20 Time 07:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-11-16 Cont ID  
Sent By wjolin Date 2016-11-16 Time 10:48 Rev Time 0.00
Received By wjolin Date 2016-11-16 Time 10:33 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-08-31 Cont ID  
Sent By wjolin Date 2016-08-31 Time 14:26 Rev Time 0.00
Received By wjolin Date 2016-08-31 Time 13:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-12-21 Cont ID  
Sent By gjohnson Date 2016-12-21 Time 10:17 Rev Time 0.00
Received By gjohnson Date 2016-12-09 Time 13:16 Sent To  
Notes
2016-12-12 13:16:24B17

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-02 Cont ID  
Sent By jwitmer Date 2016-12-02 Time 16:41 Rev Time 0.00
Received By jwitmer Date 2016-11-14 Time 11:20 Sent To  
Notes
2016-11-15 11:21:02B17

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-23 Cont ID  
Sent By gjohnson Date 2016-09-23 Time 14:56 Rev Time 0.00
Received By gjohnson Date 2016-08-29 Time 11:21 Sent To  
Notes
2016-08-30 11:21:48B16

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2016-12-21 Cont ID  
Sent By jwitmer Date 2016-12-21 Time 11:59 Rev Time 0.00
Received By jwitmer Date 2016-12-21 Time 11:59 Sent To  
Notes
2016-12-21 12:00:33P. B COUNTY IMPACT FEES
 RECEIPT NUMBER 2016-1220-108
 $4,909.52
 JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2016-12-14 Cont ID  
Sent By jwitmer Date 2016-12-14 Time 06:26 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2016-12-14 06:27:16IMPACT FEES
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2016-12-02 Cont ID  
Sent By jwitmer Date 2016-12-02 Time 16:40 Rev Time 0.00
Received By jwitmer Date 2016-12-02 Time 16:40 Sent To  
Notes
2016-12-02 16:40:16IMPACT FEES
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-09-23 Cont ID  
Sent By gjohnson Date   Time 14:54 Rev Time  
Received By gjohnson Date   Time   Sent To  
Notes
2016-12-02 16:40:00IMPACT FEES
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-12-19 Cont ID  
Sent By ccole Date 2016-12-19 Time 17:06 Rev Time 0.00
Received By ccole Date 2016-12-19 Time 17:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-11-22 Cont ID  
Sent By ccole Date 2016-11-22 Time 16:01 Rev Time 0.00
Received By ccole Date 2016-11-22 Time 16:01 Sent To  
Notes
2016-11-22 16:14:042ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16081168
 11/22/16
  
 1) 2ND REQUEST FOR A VENTILATION CALCULATION FOR THE
 NEW DAY CARE. REFER TO TABLE 403.3: DAY CARE O/A RATE
 IS CALCULATED AT 10 CFM PER OCCUPANT PLUS 0.18/SF.
 TOTAL- 294 CFMS OF O/A IS REQUIRED FOR THE NEW
 OCCUPANCY. A) SHOW THE EXISTING DUCT DROPS AND
 DIFFUSERS IN THE DAY CARE ROOM AND INCLUDE DUCT AND
 DIFFUSER SIZES AND SUPPLY CFMS AT EACH DROP. B)
 INDICATE THE COOLING AND HEATING CAPACITIES OF THE
 EXISTING SYSTEM AND THE TOTAL SUPPLY CFMS THE SYSTEM
 CAN PRODUCE.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-09-08 Cont ID  
Sent By ccole Date 2016-09-08 Time 16:29 Rev Time 0.00
Received By ccole Date 2016-09-08 Time 16:29 Sent To  
Notes
2016-09-08 16:35:471ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING,
 ENERGY CONSERVATION CODES
 PERMIT #16081168
 9/8/16
  
 1) PLEASE REVIEW SECTION C101.4.4 FBC-14 ENERGY
 CONSERVATION AS IT APPLIES TO THE PROPOSED CHANGE OF
 OCCUPANCY AND SHOW COMPLIANCE.
  
 2) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE
 AND PROVIDE A MINIMUM VENTILATION CALCULATION FOR THE
 NEW DAYCARE CLASSROOM. PROVIDE A SCHEDULE THAT
 INDICATES THE REQUIRED AND PROVIDED CFMS OF OUTDOOR
 AIR.
  
 3) SUBMIT MECHANICAL PLANS SHOWING ALL PROPOSED
 ALTERATIONS TO THE EXISTING HVAC SYSTEMS.
  
 4) ADVISORY: THE SUBMITTED PLANS ARE INCOMPLETE. PLEASE
 REVIEW THE BUILDING REVIEW COMMENTS- ADDITIONAL
 MECHANICAL COMMENTS MAY FOLLOW RESUBMITTAL OF CORRECTED
 PLANS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-12-21 Cont ID  
Sent By gjohnson Date 2016-12-21 Time 10:16 Rev Time 0.00
Received By gjohnson Date 2016-12-21 Time 10:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-11-30 Cont ID  
Sent By gjohnson Date 2016-11-30 Time 17:21 Rev Time 0.00
Received By gjohnson Date 2016-11-30 Time 17:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-09-23 Cont ID  
Sent By gjohnson Date 2016-09-23 Time 14:47 Rev Time 0.00
Received By gjohnson Date 2016-09-23 Time 14:45 Sent To  
Notes
2016-09-23 14:53:461ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS
  
 1) THE LIFE SAFETY SHEET INDICATES THIS IS A CHANGE OF
 OCCUPANCY DAYCARE WITH AN OCCUPANT LOAD OF 31 OCCUPANTS
 (20 NET). PLEASE PROVIDE THE SQUARE FOOTAGE OF THE
 CHANGE OF OCCUPANCY AND SEE FBC-B TABLE 10041.2 THE
 OCCUPANT LOAD FACTOR IS (35 NET).
  
 2) THE CODE ANALYSIS INDICATES THE OCCUPANCY AS AN (D)
 DAYCARE OCCUPANCY. PLEASE INDICATE AS TO WHICH TYPE OF
 DAYCARE/ EDUCATIONAL FACILITY THIS USE WILL FALL INTO:
 2014 FBC-B 305.2 GROUP E, DAY CARE FACILITIES. THIS
 GROUP INCLUDES BUILDINGS AND STRUCTURES OR PORTIONS
 THEREOF OCCUPIED BY MORE THAN FIVE CHILDREN OLDER THAN
 2 1/2 YEARS OF AGE WHO RECEIVE EDUCATIONAL, SUPERVISION
 OR PERSONAL CARE SERVICES FOR FEWER THAN 24 HOURS PER
 DAY.
 OR
 308.6.1 CLASSIFICATION AS GROUP E. A CHILD DAY CARE
 FACILITY THAT PROVIDES CARE FOR MORE THAN FIVE BUT NO
 MORE THAN 100 CHILDREN 2 1/2 YEARS OR LESS OF AGE,
 WHERE THE ROOMS IN WHICH THE CHILDREN ARE CARED FOR ARE
 LOCATED ON A LEVEL OF EXIT DISCHARGE SERVING SUCH ROOMS
 AND EACH OF THESE CHILD CARE ROOMS HAS AN EXIT DOOR
 DIRECTLY TO THE EXTERIOR, SHALL BE CLASSIFIED AS GROUP
 E.
 OR
 CHILDREN 2 1/2 YEARS OF AGE OR LESS USUALLY ARE NOT
 ABLE TO RECOGNIZE AN EMERGENCY SITUATION, MAY NOT
 RESPOND APPROPRIATELY OR MAY NOT BE ABLE TO EGRESS
 WITHOUT ASSISTANCE; THUS FACILITIES THAT HAVE MORE THAN
 5 CHILDREN 2 1/2 YEARS OF AGE OR LESS ARE CLASSIFIED AS
 CHILD CARE FACILITIES AND CONSIDERED TO BE GROUP I-4.
  
 3) THE PLAN INDICATES A PROPOSED DAYCARE CLASSROOM, IS
 THIS ROOM BEING ADDED TO AN EXISTING DAYCARE? THE PLANS
 DO NOT SHOW WHERE THE TOILET FACILITIES FOR THE
 DAYCARE, NOR THE FACILITIES TO BE USED FOR THE ADULTS?
  
  
 4A) 468.3.5.2 TEACHER TOILETS. FACULTY AND STAFF
 TOILETS SHALL BE SEPARATE FROM STUDENT TOILETS.
  
 4B) 468.3.5.5 WALLS. WALLS IN TOILET ROOMS SHALL BE
 IMPERVIOUS TO A HEIGHT OF AT LEAST 4 FEET (1219 MM)
 ABOVE THE FLOOR. WALLS IN KITCHENS, SCULLERIES, CAN
 WASH AREAS, AND SHOWER ROOMS SHALL BE IMPERVIOUS TO A
 HEIGHT OF AT LEAST 6 FEET (1829 MM) ABOVE THE FLOOR.
 TOILET AND SHOWER PARTITIONS SHALL BE IMPERVIOUS.
  
 4C) 2014 FBC-ACCESS. CODE 604.1 GENERAL. WATER CLOSETS
 AND TOILET COMPARTMENTS SHALL COMPLY WITH 604.2 THROUGH
 604.8. EXCEPTION: WATER CLOSETS AND TOILET COMPARTMENTS
 FOR CHILDREN?S USE SHALL BE PERMITTED TO COMPLY WITH
 604.9. 604.9 WATER CLOSETS AND TOILET COMPARTMENTS FOR
 CHILDREN?S USE.
  
 4D) WATER CLOSETS AND TOILET COMPARTMENTS FOR
 CHILDREN?S USE SHALL COMPLY WITH 604.9.
  
 4E) 468.3.4 DIAPER CHANGING STATIONS. A DIAPER CHANGING
 STATION SHALL BE LOCATED IN OR ADJACENT TO ANY
 CLASSROOM WHERE CHILDREN WEARING DIAPERS ARE IN
 ATTENDANCE. A HAND WASHING LAVATORY SHALL BE PROVIDED
 WITHIN THE CHANGING STATION AREA. ACCESS SHALL BE
 PROVIDED TO THE LAVATORY WITHOUT OPENING DOORS OR
 TOUCHING A HANDLE.
  
 5) PLEASE INDICATE PREVIOUS OCCUPANCY USE. PER WPB
 AMEND TO FBC 107.2.1
  
 6) PROVIDE A FLOOR PLAN CLEARLY SHOWING ALL PLUMBING
 FIXTURES . PER WPB AMEND TO FBC 107.2.1
  
  
  
  
  
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2016-12-15 Time   Rev Time 0.00
Received By pgreilic Date 2016-12-15 Time 10:57 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2016-11-21 Time   Rev Time 0.00
Received By pgreilic Date 2016-11-21 Time 10:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-09-19 Cont ID  
Sent By pgreilic Date 2016-09-19 Time 15:00 Rev Time 0.00
Received By pgreilic Date 2016-09-19 Time 14:23 Sent To  
Notes
***NONE***