Plan Review Details - Permit 16081146
Plan Review Stops For Permit 16081146
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-11-18 Cont ID  
Sent By shill Date 2016-11-18 Time 10:21 Rev Time 0.00
Received By shill Date 2016-11-18 Time 10:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-11-17 Cont ID  
Sent By shill Date 2016-11-17 Time 15:32 Rev Time 0.00
Received By shill Date 2016-11-17 Time 15:32 Sent To  
Notes
2016-11-17 15:35:04****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. SEE PREVIOUS COMMENT LIST. THE RESPONSE LETTER
 STATED THAT THE EXISTING CONDITIONS MEET THE INTENT OF
 THE CODE, TO SEE THE ATTACHED SKETCH, WHICH I ASSUME
 HAS DIMENSIONS AND CLEARLY SHOWS COMPLIANCE. THE SKETCH
 WAS NOT ATTACHED, AND NONE OF THE PLAN PAGES WERE
 REVISED.
  
 PLEASE RESUBMIT, INCLUDING THE REFERENCED SKETCH, OR
 REVISE THE PLAN TO SHOW COMPLIANCE (INCORPORATE
 INFORMATION FROM THE SKETCH INTO THE PLAN). PLEASE
 EMAIL WHEN THIS IS COMPLETE. THE NEXT PLAN REVIEW WILL
 BE DONE WITHIN A FEW BUSINESS DAYS OF SUBMITTAL. IF
 SUBMITTED PRIOR TO THE HOLIDAY, AN ATTEMPT WILL BE MADE
 TO COMPLETE THE PLAN REVIEW PRIOR TO THE LONG WEEKEND.
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-09-02 Cont ID  
Sent By jwitmer Date 2016-09-02 Time 07:14 Rev Time 0.00
Received By jwitmer Date 2016-09-02 Time 06:32 Sent To  
Notes
2016-09-02 07:14:48BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16081146
 ADD: 777S. FLAGLER DR. SUITE # 801E
 CONT: BUTLER
 TEL: 561-832-9700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. SEPT. 02/2016
 ACTION: DENIED
  
 1) SHEET 003_ALS.1.1 THE FRONT ENTRY DOOR DOES NOT MEET
 THE ACCESSIBILITY REQUIREMENTS UNDER THE 2014
 FBC-ACCESSIBILITY SECTION 404.2.4 AND TABLE 404.2.4.1
 MANEUVERING CLEARANCES AT MANUAL SWINGING DOOR FOR AN
 FRONT APPROACH, REQUIRES 18 INCHES ON THE LATCH SIDE OF
 THE DOOR.
  
 THE ACCESSIBILITY CODE WOULD REQUIRED UP TO $13,000.00
 DOLLARS IN ACCESSIBLE UPGRADES TO COMPLY WITH SECTION
 202.4.1 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE
 TO PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED
 AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL
 ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE
 ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY
 BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS
 ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-09-29 Cont ID  
Sent By albarran Date 2016-09-29 Time 13:25 Rev Time 0.00
Received By albarran Date 2016-09-29 Time 09:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-08-30 Cont ID  
Sent By scaldero Date 2016-08-30 Time 12:29 Rev Time 0.00
Received By scaldero Date 2016-08-30 Time 12:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-17 Cont ID  
Sent By shill Date 2016-11-17 Time 15:35 Rev Time 0.00
Received By shill Date 2016-11-04 Time 08:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-29 Cont ID  
Sent By cpuell Date 2016-09-29 Time 13:35 Rev Time 0.00
Received By cpuell Date 2016-08-29 Time 17:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-11-15 Cont ID  
Sent By ccole Date 2016-11-15 Time 13:41 Rev Time 0.00
Received By ccole Date 2016-11-15 Time 12:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-09-12 Cont ID  
Sent By ccole Date 2016-09-12 Time 12:05 Rev Time 0.00
Received By ccole Date 2016-09-12 Time 12:05 Sent To  
Notes
2016-09-12 12:09:311ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16081146
 9/12/16
  
 1) SHEET M2.1: THE 6" ROUND DUCT SUPPLYING VAV-1-8
 APPEARS TO BE UNDERSIZED. WHAT IS THE PRESSURE RATING
 OF THE SYSTEM UPSTREAM OF THE BOX?
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-09-26 Cont ID  
Sent By gjohnson Date 2016-09-26 Time 15:05 Rev Time 0.00
Received By gjohnson Date 2016-09-26 Time 15:05 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2016-11-18 Cont ID  
Sent By shill Date 2016-11-18 Time 11:04 Rev Time 0.00
Received By shill Date 2016-11-18 Time 11:04 Sent To  
Notes
2016-11-18 11:05:49PROVISO - REFER TO THE EMAIL SENT TO
 [email protected] AND [email protected] ON
 11/18/2016.
  
 THE DIGITAL SIGNATURE FOR ARCHITECT INCLUDES INITIALS
 RATHER THAN THE FULL NAME. PLEASE HAVE THIS CORRECTED
 FOR FUTURE SUBMITTALS.
  
  