Plan Review Stops For Permit 16081096
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status N Date 2017-01-18 Cont ID  
Sent By shill Date 2017-01-18 Time 11:34 Rev Time 0.00
Received By shill Date 2017-01-18 Time 11:34 Sent To  
Notes
2017-01-18 11:34:59PER SW, AIPP NOT REQUIRED (INTERIOR RENOVATION)
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-11-21 Cont ID  
Sent By shill Date 2016-11-21 Time 15:52 Rev Time 0.00
Received By shill Date 2016-11-21 Time 15:52 Sent To  
Notes
2016-11-21 16:17:391. PROVISO, UNITY OF TITLE (SUBMITTED THROUGH THE CITY
 OF WEST PALM BEACH ENGINEERING DEPARTMENT) IS REQUIRED
 TO BE RECORDED PRIOR TO C.O. PROVIDE THE COUNTY CLERK
 BOOK AND PAGE NUMBER VIA EMAIL WITH A REQUEST THAT THE
 C.O. HOLD BE REMOVED FROM THIS PERMIT.
  
 2. PROVISO, COMPLIANCE WITH ART IN PUBLIC PLACES
 ORDINANCE IS REQUIRED PRIOR TO C.O.
  
 3. THIS PROJECT IS CONSIDERED A SUBSTANTIAL
 IMPROVEMENT, FBC 1612. PROVISO, A FORM BOARD SURVEY
 WITH ELEVATIONS OR ELEVATION CERTIFICATE (BUILDING
 UNDER CONSTRUCTION), IF APPLICABLE, IS REQUIRED PRIOR
 TO POURING OF ANY CONCRETE. A FINISHED CONSTRUCTION
 ELEVATION CERTIFICATE IS REQUIRED PRIOR TO C.O. THE
 ELEVATION OF ROOFTOP EQUIPMENT IS TO BE INCLUDED ON THE
 ELEVATION CERTIFICATE IF THAT IS THE LOWEST EQUIPMENT
 SERVICING THE BUILDING.
  
 4. PROVISO, SEPARATE PERMIT REQUIRED FOR PARKING LOT
 RESTRIPE.
  
 5. PROVISO, ANY REQUIRED PRODUCT APPROVALS NOT
 SUBMITTED PRIOR TO PERMIT ISSUANCE ARE TO BE SUBMITTED
 AND REVIEWED AS A REVISION PRIOR TO INSTALLATION.
 PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-11-05 Cont ID  
Sent By jwitmer Date 2016-11-05 Time 10:58 Rev Time 0.00
Received By jwitmer Date 2016-11-05 Time   Sent To  
Notes
2016-11-05 10:53:30BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16081096
 ADD: 1250 ELIZABETH AVENUE
 CONT: ANDERSON MOORE
 TEL: 561-662-1819
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: SAT. NOV. 05/2016
 ACTION: DENIED
  
 NOTICE!!!!! NO RESPONSE LETTER!!!!! WHEN RESUBMITTING
 PLANS PLEASE INDICATE THE REVISION & REMOVE ANY VOIDED
 SHEETS & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 1) WHEN VIEWING THE ADDRESS THROUGH THE P. B. COUNTY
 PROPERTY APPRAISERS WEBSITE THIS BUILDING SITS ON (2)
 LOTS OWNED BY THE SAME OWNER.
 UNITY OF TITLE.
 THE PROPOSED BUILDING STRUCTURE TRANSGRESSES LEGAL
 BOUNDARY LINES BETWEEN THE LOTS WHICH COMBINE TO FORM
 'THE SITE'. A 'UNITY OF TITLE' SHALL BE
 RECORDED AT THE COUNTY COURTHOUSE. SUBMIT A COPY OF THE
 RECORDED 'UNITY OF TITLE' DOCUMENT SO THAT FBC TABLE
 601 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED NOT
 APPLICABLE.
 SEE WEBSITE FOR APPLICATION:
 HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP
 "APPLICATION FOR UNITY OF TITLE"
 HTTP://WWW.WPB.ORG/ENGINEERING/UPLOADS/2010-10-12-14-45
 -38-UNITYOFTITLE3.PDF
 VINCENT J NOEL
 SURVEYOR/REAL ESTATE SUPERVISOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET
 WEST PALM BEACH, FL 33401
 PHONE: 494-1040 EXT: 1096
 FAX: 494-1116
 E-MAIL: [email protected]
 *********************************************
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 2) PLEASE REVIEW ART IN PUBLIC PLACES. THE CITY OF WEST
 PALM BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT
 THAT APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT
 FOR WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER
 6/29/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $750,000 WILL NEED TO COMPLY
 WITH THIS ORDINANCE.
 PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND
 CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V,
 ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST.
 PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE
 V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND
 NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO
 THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS.
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 3) 2ND REQUEST. FLOOD ELEVATION CERTIFICATE. LINE C1.
 THE PROVIDED ELEVATION CERTIFICATES ARE MARKED AS
 FINISHED CONSTRUCTION, NOT THE CONSTRUCTION DOCUMENTS,
 THE SURVEYOR HAS USED A STAMPED SIGNATURE NOT AN
 ORIGINAL. SURVEYORS: F. S. 472.025 SEALS. ALL FINAL
 DRAWINGS, PLANS, SPECIFICATIONS, PLATS, OR REPORTS
 PREPARED OR ISSUED BY THE REGISTRANT IN ACCORDANCE WITH
 THE STANDARDS OF PRACTICE ESTABLISHED BY THE BOARD
 SHALL BE SIGNED BY THE REGISTRANT, DATED, AND STAMPED
 WITH HIS OR HER SEAL.
  
 FBC BUILDING 1612 AND CITY OF WPB CODE OF ORDINANCES
 SECTION 94-546. STRUCTURE IS LOCATED IN AN
 "A 9" FLOOD ZONE THE BASE FLOOD ELEVATION IS 13.0 FT.
 NGVD. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED.
 PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS
 REQUIRE AN ADDITIONAL 6 INCHES OF ELEVATION OR A
 MINIMUM FINISH FLOOR OF 13.5 FT. NGVD OR ON COMMERCIAL
 PROPERTY FLOOD PROOF THE WALLS AND FLOOR IF BELOW THE
 BFE. PLEASE ALSO BE AWARE OF THE VALUE OF THE 2
 STRUCTURES ON THE 2 LOTS TOTALS $785,358.00 DOLLARS IN
 VALUE. IF THE SURVEYOR FINDS THE BUILDINGS BELOW THE
 REQUIRED ELEVATION THEN EITHER THE BUILDING WOULD
 REQUIRE BEING RAISED OR FLOOD PROOFING. SECTION
 94-581-94-610 ARTICLE XIX- DEFINITIONS. (3) SUBSTANTIAL
 IMPROVEMENT MEANS ANY COMBINATION OF REPAIRS,
 RECONSTRUCTION, ALTERATION, OR IMPROVEMENTS TO A
 STRUCTURE, TAKING PLACE DURING THE LIFE OF A STRUCTURE,
 IN WHICH THE CUMULATIVE COST EQUALS OR EXCEEDS 50
 PERCENT OF THE MARKET VALUE OF THE STRUCTURE.
  
 4) COMPLIED
  
 5) 2ND REQUEST. THE LIFE SAFETY SHEET ALS1.1 SHOWS THE
 USE OF A LULA LIFT AS PART OF AN ACCESSIBLE ROUTE. 2014
 FBC-ACCESSIBILITY CODE 207.1 ACCESSIBLE MEANS OF EGRESS
 SHALL COMPLY WITH THE 2003 IBC SECTION 1007. 2003 IBC-B
 1007.1. WHERE 2 OR MORE MEANS OF EGRESS IS REQUIRED BY
 SECTION 1014.1 OR 1018.1 FROM ANY ACCESSIBLE PORTION OF
 THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO
 ACCESSIBLE MEANS OF EGRESS.
 PLEASE PROVIDE COMPLIANCE WITH ACCESS. CODE SECTION
 408.1. LIMITED-USE/LIMITED-APPLICATION ELEVATORS SHALL
 COMPLY WITH 408 AND WITH ASME A17.1 (INCORPORATED BY
 REFERENCE, SEE REFERENCED STANDARDS IN CHAPTER 1). THEY
 SHALL BE PASSENGER ELEVATORS AS CLASSIFIED BY ASME
 A17.1. ELEVATOR OPERATION SHALL BE AUTOMATIC.
  
 6) 2ND REQUEST. THE LIFE SAFETY SHEET ALS1.1 SHOWS AN
 ACCESSIBLE PARKING SPACE AND ACCESS AISLE. PLEASE NOTE
 THE RESTRIPING OF THE PARKING LOT IS UNDER SEPARATE
 PERMIT, REVIEW AND ASSOCIATED FEES. THE MARKING OF THE
 ACCESSIBLE PARKING SPACE AN ACCESS AISLE SHALL BE TO
 THE ACCESS. CODE 502.3.3/ SEE ADVISORY ADDRESSED BY
 LOCAL LAWS, SEE THE WEST PALM BEACH MUNI CODE 94-485
 STALL PAINTING DETAIL.
  
 7) 2ND REQUEST. THE LIFE SAFETY SHEET ALS1.1 SHOWS AN
 ACCESSIBLE PARKING SPACE AND ACCESS AISLE. PLEASE
 PROVIDE THE FINISH ELEVATIONS OF THE ACCESSIBLE PARKING
 SPACE AND ACCESS AISLE AND COMPLIANCE WITH THE
 FBC-ACCESS. CODE 502.4 AND EXCEPTION: SLOPES NOT
 STEEPER THAN 1:48 SHALL BE PERMITTED.
  
 8) 2ND REQUEST. FBC 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 9) 2ND REQUEST. 2014 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA
 DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010
 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS
 THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS- FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE.
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (G) PRE-ENGINEERED A/C STANDS
  
 IF EITHER THE CONTRACTOR OR THE DESIGNER OF RECORD
 WISHES TO DEFER THE PRODUCT APPROVALS UNTIL AFTER
 PERMIT ISSUANCE PLEASE INDICATE AS SUCH IN THE
 NARRATIVE RESPONSE. THANK YOU.
  
 10) 2ND REQUEST. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY.
 THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-09-14 Cont ID  
Sent By jwitmer Date 2016-09-14 Time 16:31 Rev Time 0.00
Received By jwitmer Date 2016-09-14 Time 13:39 Sent To  
Notes
2016-09-14 16:31:44BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16081096
 ADD: 1250 ELIZABETH AVENUE
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-228-8838
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 14/2016
 ACTION: DENIED
  
 1) WHEN VIEWING THE ADDRESS THROUGH THE P. B. COUNTY
 PROPERTY APPRAISERS WEBSITE THIS BUILDING SITS ON 2
 LOTS OWNED BY TO DIFFERENT OWNERS.
 LOT #1 ADDRESS 1250 ELIZABETH AVENUE OWNER: JOHNSTONE
 DIXIE PARTNERS
 LOT # 2 ADDRESS 1301 CLARE AVENUE OWNER: 1401 CLARE
 AVE. LLC
  
 2) PLEASE REVIEW ART IN PUBLIC PLACES. THE CITY OF WEST
 PALM BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT
 THAT APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT
 FOR WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER
 6/29/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $750,000 WILL NEED TO COMPLY
 WITH THIS ORDINANCE.
 PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND
 CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V,
 ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST.
 PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE
 V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND
 NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO
 THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS.
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 3) FBC BUILDING 1612 AND CITY OF WPB CODE OF ORDINANCES
 SECTION 94-546. STRUCTURE IS LOCATED IN AN
 "A 9" FLOOD ZONE THE BASE FLOOD ELEVATION IS 13.0 FT.
 NGVD. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED.
 PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS
 REQUIRE AN ADDITIONAL 6 INCHES OF ELEVATION OR A
 MINIMUM FINISH FLOOR OF 13.5 FT. NGVD OR ON COMMERCIAL
 PROPERTY FLOOD PROOF THE WALLS AND FLOOR IF BELOW THE
 BFE. PLEASE ALSO BE AWARE OF THE VALUE OF THE 2
 STRUCTURES ON THE 2 LOTS TOTALS $785,358.00 DOLLARS IN
 VALUE. IF THE SURVEYOR FINDS THE BUILDINGS BELOW THE
 REQUIRED ELEVATION THEN EITHER THE BUILDING WOULD
 REQUIRE BEING RAISED OR FLOOD PROOFING. SECTION
 94-581-94-610 ARTICLE XIX- DEFINITIONS. (3) SUBSTANTIAL
 IMPROVEMENT MEANS ANY COMBINATION OF REPAIRS,
 RECONSTRUCTION, ALTERATION, OR IMPROVEMENTS TO A
 STRUCTURE, TAKING PLACE DURING THE LIFE OF A STRUCTURE,
 IN WHICH THE CUMULATIVE COST EQUALS OR EXCEEDS 50
 PERCENT OF THE MARKET VALUE OF THE STRUCTURE.
 4) LIFE SAFETY SHEET ALS1.1 SHOWS A LARGE ROOM
 IDENTIFIED AS 108 BUT THE END USAGE IS NOT SHOWN? THERE
 IS NO FLOOR PLAN SHOWING A FURNITURE LAYOUT AND THE
 EGRESS PATH THRU THIS ROOM. 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED TO DETERMINE CODE COMPLIANCE.
 5) THE LIFE SAFETY SHEET ALS1.1 SHOWS THE USE OF A LULA
 LIFT AS PART OF AN ACCESSIBLE ROUTE. 2014
 FBC-ACCESSIBILITY CODE 207.1 ACCESSIBLE MEANS OF EGRESS
 SHALL COMPLY WITH THE 2003 IBC SECTION 1007. 2003 IBC-B
 1007.1. WHERE 2 OR MORE MEANS OF EGRESS IS REQUIRED BY
 SECTION 1014.1 OR 1018.1 FROM ANY ACCESSIBLE PORTION OF
 THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO
 ACCESSIBLE MEANS OF EGRESS.
 PLEASE PROVIDE COMPLIANCE WITH ACCESS. CODE SECTION
 408.1. LIMITED-USE/LIMITED-APPLICATION ELEVATORS SHALL
 COMPLY WITH 408 AND WITH ASME A17.1 (INCORPORATED BY
 REFERENCE, SEE ?REFERENCED STANDARDS? IN CHAPTER 1).
 THEY SHALL BE PASSENGER ELEVATORS AS CLASSIFIED BY ASME
 A17.1. ELEVATOR OPERATION SHALL BE AUTOMATIC.
 6) THE LIFE SAFETY SHEET ALS1.1 SHOWS AN ACCESSIBLE
 PARKING SPACE AND ACCESS AISLE. PLEASE NOTE THE
 RESTRIPING OF THE PARKING LOT IS UNDER SEPARATE PERMIT,
 REVIEW AND ASSOCIATED FEES. THE MARKING OF THE
 ACCESSIBLE PARKING SPACE AN ACCESS AISLE SHALL BE TO
 THE ACCESS. CODE 502.3.3/ SEE ADVISORY ADDRESSED BY
 LOCAL LAWS, SEE THE WEST PALM BEACH MUNI CODE 94-485
 STALL PAINTING DETAIL.
 7) THE LIFE SAFETY SHEET ALS1.1 SHOWS AN ACCESSIBLE
 PARKING SPACE AND ACCESS AISLE. PLEASE PROVIDE THE
 FINISH ELEVATIONS OF THE ACCESSIBLE PARKING SPACE AND
 ACCESS AISLE AND COMPLIANCE WITH THE FBC-ACCESS. CODE
 502.4 AND EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL
 BE PERMITTED.
 8) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 9) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS- FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE.
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (G) PRE-ENGINEERED A/C STANDS
  
 IF EITHER THE CONTRACTOR OR THE DESIGNER OF RECORD
 WISHES TO DEFER THE PRODUCT APPROVALS UNTIL AFTER
 PERMIT ISSUANCE PLEASE INDICATE AS SUCH IN THE
 NARRATIVE RESPONSE. THANK YOU.
  
 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-10-31 Cont ID  
Sent By vperez Date 2016-10-31 Time 16:31 Rev Time 0.00
Received By vperez Date 2016-10-31 Time 16:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-08-29 Cont ID  
Sent By albarran Date 2016-08-29 Time 17:09 Rev Time 0.00
Received By albarran Date 2016-08-29 Time 14:53 Sent To  
Notes
2016-08-29 17:10:04ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC)
  
 PROJECT NAME: 1250 ELIZABETH AVENUE
 JOB ADDRESS: 1250 ELIZABETH AVENUE
 DESCRIPTION: SQUASH COURTS, WAREHOUSE,
 OFFICE-RENOVATING EXISTING SPACE
 MASTER PERMIT: 16081096
  
 BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS.
 ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF
 SUBMITTED CORRECTIONS.
  
 1. IN YOUR GENERAL ELECTRICAL NOTES ON SHEET E0.1, YOUR
 NOTE 2 SHALL QUOTE THE SPECIFIC APPLICABLE CODES AND
 NOT GENERALIZATION. NOTE 3 DICTATES CONDUCTOR
 INSULATION BASED ON SIZE. CONDUCTOR INSULATION IS
 DETERMINED BY THE APPLICATION AND NOT SIZE. A
 CONDUCTOR, NO MATTER WHAT SIZE IN A WET LOCATION SHALL
 BE INSULATED ACCORDINGLY.
 2. NEC 230.2(E) REQUIRES THAT EACH SERVICE BE PLACARDED
 TO INDICATE THE EXISTENCE AND LOCATION OF ANY OTHER
 SERVICE SUPPLYING THE BUILDING.
 3. NEC 600.5 STATES THAT EACH COMMERCIAL BUILDING AND
 EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO PEDESTRIANS
 SHALL BE PROVIDED WITH AT LEAST ONE 20 AMP DEDICATED
 OUTLET IN AN ACCESSIBLE LOCATION AT EACH ENTRANCE TO
 EACH TENANT SPACE FOR SIGN OR OUTLINE LIGHTING. SERVICE
 HALLWAYS OR CORRIDORS SHALL NOT BE CONSIDERED
 ACCESSIBLE TO PEDESTRIANS. I DO NOT SEE THIS ON ANY OF
 THE DOORS ON EITHER THE POWER OR LIGHTING PLAN.
 4. NEC 210.62 CALLS FOR AT LEAST ONE RECEPTACLE OUTLET
 TO BE INSTALLED WITHIN 18? OF THE TOP OF A SHOW WINDOW
 FOR EVERY 12 LINEAR FT. OR MAJOR PORTION THEREOF AREA
 MEASURED HORIZONTALLY. THIS APPLIES TO THE STORE FRONT
 AREAS OF THIS BLDG.
 5. NEC 406.9(B) RECEPTACLES IN WET LOCATIONS. 15 AND 20
 AMPERE, 125 AND 250 VOLT RECEPTACLES INSTALLED IN A WET
 LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF
 WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. ALL
 15 AND 20 AMPERE, 125 AND 250 VOLT NONLOCKING
 RECEPTACLES SHALL BE LISTED WEATHER-RESISTANT TYPE
 ?WR?. CORRECT DETAIL 3 ON SHEET E5.1 TO COMPLY. (
 REQUIRES AN IN-USE TYPE COVER).
 6. FBC-B 1006.3 REQUIRES THAT THE EXIT DISCHARGE BE
 ILLUMINATED UNDER EMERGENCY POWER. THE SUBMITTED
 DRAWINGS DO SHOW EXTERIOR LIGHTING BUT NOT ANY
 EMERGENCY LIGHTING.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-11-10 Cont ID  
Sent By wjolin Date 2016-11-10 Time 08:48 Rev Time 0.00
Received By wjolin Date 2016-11-08 Time 13:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-09-01 Cont ID  
Sent By wjolin Date 2016-09-01 Time 13:34 Rev Time 0.00
Received By wjolin Date 2016-09-01 Time 12:34 Sent To  
Notes
2016-09-01 13:34:561250 ELIZABETH AVENUE
 PERMIT #16081096
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE LARGE OPEN ROOM #108 DOES NOT APPEAR TO HAVE A
 SPECIFIC OCCUPANCY, USE, FURNITURE, ETC.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-11-21 Cont ID  
Sent By shill Date 2016-11-21 Time 15:52 Rev Time 0.00
Received By shill Date 2016-11-17 Time 11:33 Sent To  
Notes
2016-11-19 11:23:1911/19 TO SH DESK
  
  
2016-11-17 11:33:58TO CCOLE DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date 2016-11-10 Cont ID  
Sent By skennedy Date 2016-11-17 Time 09:24 Rev Time 0.00
Received By skennedy Date 2016-10-17 Time 11:34 Sent To  
Notes
2016-10-18 11:34:18C31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-26 Cont ID  
Sent By gjohnson Date 2016-09-26 Time 10:25 Rev Time 0.00
Received By gjohnson Date 2016-08-25 Time 10:24 Sent To  
Notes
2016-08-26 10:24:17C33

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2016-11-17 Cont ID  
Sent By skennedy Date 2016-11-17 Time 11:32 Rev Time 0.00
Received By skennedy Date 2016-11-17 Time 11:32 Sent To  
Notes
2016-11-21 13:38:33MU 2016-26853 (GEN INDUSTRIAL, $0)
  
 MU 2016-26855 (RACQUET CLUB)
 STAMPED PLAN AND RECEIPT
  
2016-11-07 13:46:44IMPACT FEES SUBMITTED 11/4/16

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2016-11-05 Cont ID  
Sent By   Date 2016-11-05 Time 10:58 Rev Time 0.00
Received By   Date 2016-11-05 Time   Sent To  
Notes
2016-11-05 10:54:03BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-09-14 Cont ID  
Sent By jwitmer Date 2016-09-14 Time 16:32 Rev Time 0.00
Received By jwitmer Date 2016-09-14 Time 14:01 Sent To  
Notes
2016-09-14 14:25:20IMPACT FEES
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-11-17 Cont ID  
Sent By ccole Date 2016-11-17 Time 17:52 Rev Time 0.00
Received By ccole Date 2016-11-17 Time 17:52 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-10-28 Cont ID  
Sent By ccole Date 2016-10-28 Time 12:00 Rev Time 0.00
Received By ccole Date 2016-10-28 Time 12:00 Sent To  
Notes
2016-10-28 12:12:412ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16081096
 10/28/16
  
 1) THE AC CALCULATIONS FOR RTU-3A INDICATE 8.6 KW HEAT
 REQUIRED, THE SCHEDULE INDICATES 4.0 KW PROVIDED. RTU-
 3B- 11.66 KW REQUIRED, 6.0 KW PROVIDED.
  
 2) SHEET M1.1: IT APPEARS THAT THERE IS NO WAY FOR THE
 AIR SUPPLIED TO ALL THE FLEX, OFFICE, SALES, MANGEMENT
 ROOMS ETC. TO RETURN TO RTU-1. THE ARCHITECTURAL
 DRAWINGS APPEAR TO INDICATE THE FRAMED AND GLASS WALLS
 ARE SPANNING FROM FLOOR TO UNDERSIDE OF DECK WHICH
 WOULD CLOSE OFF THE AIRWAYS- SEE SHEETS A1.1, A3.1.2, &
 A5.0.1.
  
 3) IN RESPONSE TO COMMENT #13 FROM THE 1ST REVIEW, THE
 ENGINEER IS REQUESTED THE WIND LOAD ENGINEERING FOR
 ANCHORING THE NEW RTU'S TO BE DEFERRED SUBMITTALS WHICH
 IS ACCEPTED. PLEASE REVIEW THE FOLLOWING REQUIREMENTS
 PER SECTION 107.3.4.2 WPB AMENDMENTS TO THE FBC:
  
 A) DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE
 APPLICATION AND THAT ARE TO BE SUBMITTED TO THE
 BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL
 OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF
 THE BUILDING OFFICIAL. THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE
 DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR
 REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 B)107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FROM THE 1ST REVIEW, THE ENGINEER IS REQUESTED THE WIND
 LOAD ENGINEERING FOR ANCHORING THE NEW RTU'S TO BE
 DEFERRED SUBMITTALS. PLEASE REVIEW THE FOLLOWING
 REQUIREMENTS PER SECTION
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-09-06 Cont ID  
Sent By ccole Date 2016-09-06 Time 14:10 Rev Time 0.00
Received By ccole Date 2016-09-06 Time 11:39 Sent To  
Notes
2016-09-06 15:17:291ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING,
 ENERGY CONSERVATION CODES
 PERMIT #16081096
 9/6/16
  
 1) THE PROJECT IS INCORRECTLY IDENTIFED AS A RENOVATION
 IN THE PROJECT SUMMARY OF THE ENERGYGAUGE COMPLIANCE
 SUBMITTAL. THE CORRECT IDENTIFICATION PER SECTION 202
 FBC-14 EXISTING BUILDING IS CHANGE OF OCCUPANCY- PLEASE
 CORRECT.
  
 2) THE SUMMARY AC CALCULATIONS MUST INCLUDE THE TOTAL
 LATENT GAINS FOR EACH SYSTEM- REFER TO SECTION C403.2.1
 FBC-14 ENERGY CONSERVATION EXCEPTION.
  
 3) SHEET M0.2: RTU-1 & RTU- 3A AT 12.5 AND 5TON PER THE
 SCHEDULE ARE EACH EXCEEDING THE COOLING LOADS
 CALCULATED- SEE SECTION C403.2.2.
  
 4) M0.2: THE ELECTRIC HEAT KW CAPACITIES SHOWN IN THE
 SCHEDULE FOR RTU-1 AND RTU-3B ARE UNDERSIZED PER THE
 CALCULATED HEATING LOADS- C403.2.2.
  
 5) M0.2: PLEASE PROVIDE THE COOLING CAPACITY AND
 EFFICIENCY RATING OF RTU-4 IN THE SCHEDULE- SEE PAGE 6
 OF ENERGY SUBMITTAL.
  
 6) M0.2: THE O/A CALCULATIONS FOR THE SQUASH COURTS AND
 SPECTATOR AREA ARE NOT IN COMPLIANCE WITH TABLE 403.3
 FBC-14 MECHANICAL- RATES AND OCCUPANT DENSITIES.
  
 7) REFER TO SECTION C403.2.4.4 AND SHOW COMPLIANCE FOR
 O/A SHUTOFF DAMPER CONTROLS.
  
 8) PROVIDE CONTROL DIAGRAMS FOR EXHAUST FANS F-1A &
 F-1B.
  
 9) DUCT SMOKE DETECTORS ARE REQUIRED IN THE RETURN AIR
 SYSTEMS OF RTU'S 3A & 3B PER SECTION 606.2.1. NOTE:
 THIS REQJUIREMENT WILL BE WAIVED PENDING SUBMITTAL OF
 MANUFACTURER'S DATA INDICATING THE SYSTEMS CANNOT
 EXCEED 2000 CFMS OF SUPPLY AIR.
  
 10) M1.1: THE RETURN AIR GRILLS FOR RTU'S 3A & 3B ARE
 UNDERSIZED FOR 1272 CMFS OF RETURN AIR.
  
 11) PLEASE CLARIFY THE USE OF THE OPEN AREA. THE TYPE
 OF ACTIVITIES THAT WILL TAKE PLACE THERE COULD IMPACT
 THE O/A RATES AND AC SYSTEMS.
  
 12) PROVIDE A MECHANICAL ROOF PLAN SHOWING RTU AND FAN
 LOCATIONS, AND ALL REQUIRED CLEARANCE DISTANCE
 MEASUREMENTS.
  
 13) PROVIDE THE WIND LOAD DESIGN CRITERIA FOR ALL
 ROOFTOP MECHANICAL INSTALLATIONS, AND DRAWINGS AND
 DETAILS FOR COMPLETE INSTALLATIONS OF THE RTU'S AND
 CURBS, FANS AND CURBS, AND ROOFTOP DUCTWORK.
  
 14) REFER TO SECTION 6.4.3 OF THE ASHRAE STANDARD 90.1
 AND PROVIDE HVAC CONTROL NOTES ON SHEET M6.1.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-10-29 Cont ID  
Sent By gjohnson Date 2016-10-29 Time 13:26 Rev Time 0.00
Received By gjohnson Date 2016-10-29 Time 13:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-09-26 Cont ID  
Sent By gjohnson Date 2016-09-26 Time 10:17 Rev Time 0.00
Received By gjohnson Date 2016-09-26 Time 09:21 Sent To  
Notes
2016-09-26 10:25:401ST REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS:
  
 1. THE PLUMBING CODE REQUIRES SEPARATE FACILITIES FOR
 MEN AND WOMEN , IT WILL BE NECESSARY TO INDICATE ON THE
 PLAN WHICH BATHROOMS WILL BE FOR MEN AND WHICH
 BATHROOMS WILL BE FOR WOMEN.
 PER. FBC PL 403.2 SEPARATE FACILITIES.
 WHERE PLUMBING FIXTURES ARE REQUIRED, SEPARATE
 FACILITIES SHALL BE PROVIDED FOR EACH SEX.
 403.4 SIGNAGE.
 REQUIRED PUBLIC FACILITIES SHALL BE DESIGNATED BY A
 LEGIBLE SIGN FOR EACH SEX. SIGNS SHALL BE READILY
 VISIBLE AND LOCATED NEAR THE ENTRANCE TO EACH TOILET
 FACILITY. SIGNS FOR ACCESSIBLE TOILET FACILITIES SHALL
 COMPLY WITH THE FLORIDA BUILDING CODE, ACCESSIBILITY
  
 2. PLEASE INDICATE ON THE PLAN WHAT THE OPEN ROOM #108
 WILL BE USED FOR ALSO GIVE OCCUPANT LOAD. PER WPB AMEND
 TO FBC 107.2.1
  
 3. IF THE OPEN ROOM #108 IS AN ASSEMBLY OCCUPANCY YOU
 WILL BE REQUIRED TO COMPLY WITH. FBC PL 403.1.3 POTTY
 PARITY.
 IN ASSEMBLY OCCUPANCIES, RESTROOMS WHICH ARE OPEN TO
 THE PUBLIC MUST HAVE A RATIO OF 3:2 WATER CLOSETS
 PROVIDED FOR WOMEN AS THE COMBINED TOTAL OF WATER
 CLOSETS AND URINALS PROVIDED FOR MEN, UNLESS THESE ARE
 TWO OR FEWER SUCH FIXTURES FOR MEN, IN ACCORDANCE WITH
 SECTION 553.86, FLORIDA STATUTES.

Review Stop Z ZONING
Rev No 2 Status P Date 2016-11-03 Cont ID  
Sent By ajones Date 2016-11-03 Time 16:16 Rev Time 0.00
Received By ajones Date 2016-11-03 Time 16:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-09-01 Cont ID  
Sent By ajones Date 2016-09-01 Time 15:26 Rev Time 0.00
Received By ajones Date 2016-09-01 Time 15:26 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved